| 1 | Material and labour for providing anti-termite treatment (Post Construction) along the external wall below concrete apron/ plinth protection using chemical emulsion (for using Chloropyriohos emulsifiable concentrates conforming to IS-8944 - 2005) @ 2.25 Litre per linear metre, the hole 300mm apart including drilling and plugging 12mm dia holes with cement mortar (1:2) to match with the existing floors complete all as specified and directed. (Note : To dilute chemical of 20 percent concentration, 19 parts of water to one part of the chemical shall be added to achieve 1 (one) percent concentration.) |
| 2 | Material and labour for providing anti-termite treatment (Post Construction) under existing floors using chemical emulsion (for using Chloropyriohos emulsifiable concentrates conforming to IS-8944 - 2005) @1.00 Litre per hole. 300mm apart including drilling and plugging 12mm dia holes with CM (1:2) to match with the existing floors complete all as specified and directed. (Note : To dilute chemical of 20 percent concentration, 19 parts of water to one part of the chemical shall be added to achieve 1 (one) percent concentration.) |
| 3 | Material and labour for providing anti-termite treatment (Post Construction) at point of contact of wood work with floor or wall, using chemical emulsion (in oil or kerosene based solution of Chloropyriohos 1.0% by weight concentration shall be used for treatment of wood or wood based products) @ 0.50 Litre per hole by drilling 6mm dia holes at a downward angle angle of 45° at 150 centre to centre and sealing with CM (1:2) to match with the existing surface complete all as specified and directed. (Note : To dilute chemical of 20 percent concentration, 19 parts of oil or kerosene to one part of the chemical shall be added to achieve 1 (one) percent concentration.) |
| 4 | Taking down cement plaster of any description including racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 5 | M&L Rendering 10 mm thick internal using cement plaster in CM 1:6 on fair faces of brick/concrete work surfaces to be finished even and smooth (without using extra lime or cement complete all as specified and directed. |
| 6 | M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:4) finished fair and even all as specified and directed. |
| 7 | M & L for 5mm thick rendering on fair faces of brick work or concrete surfaces in CM ( 1:3 ) finished even and smooth (without using extra lime or cement) on Ceiling complete all as specified and as directed. |
| 8 | M&L for preparing newly plastered surfaces and applying two coats of oil bound distemper over a coat of chalk whiting, white primer complete on walls complete all as specified and directed. |
| 9 | M&L for two coats of cement base paint over a coat of white wash on new plastered surfaces including preparation of surfaces complete all as specified and directed. |
| 10 | Material and labour for applying two coats of oil bound distemper on ceiling over a coat priming paint including preparation of new surfaces complete all as specified. |
| 11 | Material and labour for grouting in roof through PVC nipples at a spacing of 45 to 60cm C/C including drilling injection points to a depth of 75-100mm, providing 10mm dia PVC nipples and pressure grouting using with and including cement mixed with plasticizing admixture @ 225gms/50kg of cement to fill up all capillaries/ voids/ honeycombing areas inside concrete with pressure of 2 to 4 Kg/Sqcm and continued till refusal. After grouting, nozzles to be sealed with the sealing compound/mortar etc, all as per manufacturers instructions and as directed.Note:- After ascertaining the location of leakage/ seepage/dampness under item No.2 here-in-before, this item shall be operated at the required location. |
| 12 | M&L for rendering over roof slab 10 mm thick in CM 1:3 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement and finished surfaces fair and even all as specified and directed. (WPC shall be measured and paid separately) complete all as specified and directed. |
| 13 | Supply only integral water proofing compound. complete all as specified and directed. |
| 14 | M&L for cement concrete type E - 2, 1:5:10 (using 40 mm graded stone aggregate) as in sunken flooring. complete all as specified and directed. |
| 15 | Taking down existing water proofing treatment and roughening surfaces of old concrete floor etc by picking, sweeping clean and washing down with water to remove dust, etc.the existing bituminous coating and disposing rubbish off the premises to a distance exeeding 150 mtr and n. exc 250 mtr complete all as specified. complete all as specified. |
| 16 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate on RCC roof slabs to fill undulations to achieve uniform slope complete all as specified and directed. |
| 17 | Material and labour for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm including cleaning of surfaces complete all as specified. |
| 18 | Material & labour for APP based polymeric membrane minimum weight 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (weight not less than 150gm/Sqm) laid on primed surfaces by forced application complete all as specified. |
| 19 | Disconnecting existing PVC water tanks of capacity exc 250 litres & n. exc 500 litres setting aside (or lowering) for repair work and hoisting , reconnecting, refixng in the same position complete all as specified and as directed. |
| 20 | Disconnecting existing PVC water tanks of capacity exc 500 litres & n. exc 1000 litres setting aside (or lowering) for repair work and hoisting , reconnecting, refining in the same position complete all as specified and as directed. |
| 21 | Taking up or down steel tubing and connections 15mm bore all as specified and as directed . |
| 22 | Taking up or down steel tubing and connections 20mm bore all as specified and as directed. |
| 23 | Taking up or down steel tubing and connections 25mm bore all as specified and as directed . |
| 24 | Refixing the steel tubing 15mm bore obtained from item No. 21 above after, cleaning in new or old position (wall, ceiling, floor etc.) complete all as specified and as directed . |
| 25 | Refixing the steel tubing 20mm bore obtained from item No 22 above after cleaning in new or old position (wall, ceiling, floor etc.) complete all as specified and as directed . |
| 26 | Refixing the steel tubing 25mm bore obtained from item No 23 above after cleaning in new or old position (wall, ceiling, floor etc.) complete all as specified and as directed. |
| 27 | S&F GI water tubes 15mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and as directed. |
| 28 | S&F GI water tubes of bore 20 mm dia tubes medium grade with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and directed. |
| 29 | S&F GI water tubes of bore 25 mm dia tubes medium grade with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and directed. |
| 30 | S&F in repairs 20mm bore ball brass valves. high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 31 | S&F in repairsPVC (SWR) 110 mm bore of pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 32 | S&F in repair PVC (SWR) 100 mm bore of bends any radius complete all as specified and directed. |
| 33 | S&F in repairsPVC (SWR) 75 mm bore of pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 34 | S&F in repair PVC (SWR) 75 mm bore of bends any radius complete all as specified and directed. |
| 35 | S&F in repairs PVC trap 110 mm dia with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and directed. |
| 36 | Dismantling floor, heart or wall tiling including cement mortar bedding (but not backing ), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 37 | Demolation of cement concrete of any description and in any position not otherwise specifically provided for as specified and directed. |
| 38 | M & L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate)complete all as specified and directed. |
| 39 | M&L joint free colored non skid ceramic tiles 6 to 7 mm thick (square or rectangular) area of each tile exceeding 0.18 sqm but not exc 0.38 Sqm in floors etc set and jointed in neat cement slurry and pointed in site or colored cement to match over 15mm cement screed bed in cement mortar 1:4 as specified and directed |
| 40 | M&L colored glazed ceramic tiles in vertical surface 300x 450x 6-7mm thick set and jointed in neat cement slurry and pointed in site or color cement to match including rendering 10mm thick in cement mortar 1:3 complete all as specified and directed. |
| 41 | S&F in repair vitreous China squatting pan, `Orissa' pattern, size 630 x450 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and directed. |
| 42 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (including 6 mm dia 50 mm long fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut) with Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device including PVC valveless, syphonic action type, flushing cistern 10 LTRS CAPACITY, low level, white, with inlet, ball valve, float and handle including brackets fixed in repairs with 32 mm PTMT Flush pipes to pedestal pan, including all joints complete all as specified and directed. |
| 43 | DismantilingAsbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 44 | M & L for PCC type C-1, 1:3:6 (20 mm graded aggregate) as in foundation, filling and mass-concrete and like filling in fencing post complete all as specified and directed. |
| 45 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 46 | S&F Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified . |
| 47 | Dismantling of wrought iron or MS work of any description complete all as specified and directed. |
| 48 | M&L for roof trusses framed trussed pulins crance rails and fastening and heavey brackets framing ( Beam tee, angle, chall or flat sections indl distance pieces, cleats etc Fe-410W (Gde E 250) complete all as specified and directed. |
| 49 | M&L for preparation of new untreated surfaces of steel of any description exc 10cm width or girth not other wise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |