| Sl. No. | Item Description |
| 1 | Dismantling of brick tiles or terracing tiles single layer on roof , mumty and removal of debrish beyond MOD land complete all as specified and directed. |
| 2 | Demolition of mud phuska on roof slabs, any thickness including cleaning of roof surfaces and removing the debris upto the distance exc 1.00 Km but not n.exc 1. 5 Km complete all as specified and directed. |
| 3 | M&L for wire brushing and cleaning top surface of existing roof surface, and including taking down old APP membrane flashings and junction of parapets, etc. complete all as sepcified and directed. |
| 4 | M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof padding/kerb, mud slopes, rounded or chamfered edge complete all as specified and directed |
| 5 | M&L for 10mm thick screed bed in cement mortar 1:4 with water proofing liquid as per manufacturer instructions when concrete is a still green etc complete alll as specified and directed.(Note:- Water proofing liquid shall be measured and separately) |
| 6 | M&L for applying a coat of bitumen primer confirming @0.50 ltr/ Sqm on prepared surface of plaster and applying a coat of hot blown bitumen 85/25 gde @1.2 kg/sqm and applying APP based Polymeric membrane minimum weighting 3.0kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt.not less than 150 grm/ sqm) and sealing joints by torched application complete all as specified and as directed. (Note: Work be done through approved applicator only) |
| 7 | Supply and fixing Heat Resistant cement based Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. complete all as specified and as directed. |
| 8 | Supply only liquid water proofing compound of approved make complete all as specified and as directed. |
| 9 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:6 complete all as spd & directed by Engr-in-Charge. |
| 10 | M&L for rendering 15mm thick cement plaster in CM 1:4 on brick work or concrete surfaces finished even and fair complete all as spd & directed by Engr-in-Charge. |
| 11 | M&L preparation of newly plastered surfaces and applying two coats of cement base paint over and including a coat of alkali resistance primer on external surfaces of walls complete all as specified and directed. |
| 12 | Taking down door/window/ventilator frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Sqm each complete all as specified and as directed. |
| 13 | Taking down door/window/ventilator frames with shutters (without taking off shutters from the frames) of size exceeding 1.5 Sqm and not exceeding 4 Sqm each complete all as specified and as directed. |
| 14 | Demoltion of brick work built in cement mortar of any specification and in any position complete all as specified and as directed. |
| 15 | All as per Serl Item No 9 here in before but half brick thick wall built in cement mortar 1:4 complete all as specified and directed. |
| 16 | Dismantling of stone slabs and tiles of any description or thickness in floors aprons laid bedded and pointed in any mortar complete all as specified and as directed. |
| 17 | Demolition of unreinforced cement concrete in ground floor and pavings n.exc. 15 cm thick (below or above GL) complete all as specified and directed by Engineer in Charge |
| 18 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. |
| 19 | M&L for 75mm tk Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floors finishes complete all as specified and directed |
| 20 | M&L for Coloured Cement concrete Pre polished & reflective type chequered tiles 30cm X 30cm X 25mm thick machine pressed; set jointed and pointed in neat cement slurry in floors and cut and pointed with white cement and pigment including demolition of old tiles complete all as per per specified and directed. |
| 21 | M&L for cement screed bed or bedding layer on floor 20 mm thick in CM 1:6 complete all as specified and directed. |
| 22 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 23 | M&L for 60mm thick, M-35 Grade Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 with grey cement and pigment complete all as specified and directed. |
| 24 | M&L for 75mm thick PCC(1:3:6) type C2 (using 40mm stone aggregate) as in floors/paving/plinth protection etc, finished even and fair without using extra cement grooves filled with bitumen mastic filling of mix(1:2) (bitumen and sand) complete all as specified and as directed. |
| 25 | M&L for Plain cement concrete 1:2:4 type B -1(20mm graded aggregate) all around the interlocking tiles to fix in position as in kerbs Complete all as specified and directed by Engr-in-charge |
| 26 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as sspecified and as directed. |
| 27 | M&L for Glazed ceramic coloured joint free tiles of size 350x 250x 7 mm/ 450X 350X 7mm on vertical surfaces of walls such as skirting dado etc and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 28 | M & L for Vitrified ceramic tiles 10mm thick (Square/rectangular)polished area of each tiles not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured (Light Shade)cement to match over 20 mm thick screed bed or bedding layer of cement mortar(1:6) for laying floor finishes complete all as specified. |
| 29 | M&L for light shade Vitrified tile 10mm thick polished, area of each tile n exc.0.36 sqm as in Skirting set and jointed in cement slurry over and including 10mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed. |
| 30 | M&L for coloured joint free non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl screed bedding 15mm thick in cement mortar (1:6) all as specified and directed. |
| 31 | M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165complete all as specified and directed. |
| 32 | M& L for Pressed steel frames for doors with double rebates size- 125 x 60mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed |
| 33 | S &F 2nd class hardwood rail and style, factory made 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I). klin seasoned and chemically pressure treated complete all as specified and directed. |
| 34 | S&F glazed and skelton shutter IInd class hard wood 35 mm thick rebated and prepared to received glass, gauge etc with sash bars edges of forming plain,chamfered or rounded fitted with mitred beads for securing glass etc size of members of shutter as specified in SSR Part-I section 8,clause 8.24(a) etc.complete all as specified and directed. |
| 35 | S&F Powder coated (minimum thickness of powder coating 50 micron) aluminium three track window, shutter (Size 45X 15mm) i.e. two shutter with 4.8mm thick tinted glass and one with stainless steel wire cloth of 0.36mm dia and avg width of apperture 1.4mm and sliding section (confirming section Cat No 20814 from ' Jindal') complete window size (92X45.5mm) with frame (Chowkhat) size (101.6X44.45X1.9mm thick), including all necessary locking arrangements (touch lock of zinc alloyed powder coated as per sample) and fittings complete all as specified and as directed. |
| 36 | S&F anodised aluminium ventilator with aluminium anodised frame of aluminium section 62.5 mm x 37mmx1.5mm thick and with top hung shutters having shutter wire gauzed and glazed, glass pane without sash bars including necessary jointing cleats, glazing clips, rubber packing, anodized, aluminium snap beading, screws, anodised aluminium fitting such as peg stays 150mm long, handles and 100mm long SS hinges etc complete all as specified and directed. |
| 37 | S&F aluminium anodised barrel tower bolt, extruded section 200mm size complete all as specified and directed. |
| 38 | S&F aluminium anodised Handles cast type for 150mm size complete all as specified and directed. |
| 39 | S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut complete all as specified and directed. |
| 40 | S&F butt hinges 100mm size, medium weight cold rolled mild steel and fixed to angle iron /steel chowkhat complete all as specified and directed. |
| 41 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, AC sheet etc.) or insulation boards/ slabs/blankets, any thickness, including cover fillets any description fixed in any position complete all as specified and directed. |
| 42 | S&F for anodised aluminium snap grid frame work for false ceiling of size 605x605mm including hanger 6 mm dia G.I. (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed. |
| 43 | M&L for gypsum board 12 mm thick in ceiling fixed with screw as per maufacturer's instruction complete all as specified and directed . |
| 44 | M&L for Forming jambs etc built in cement mortar 1:6 to openings incl cutting toothing and properly bonding into old work also facing ,jointing and pointing to match to existing work complete all as specified. |
| 45 | M&L 15mm thick rendering with ready mix mortar of approved make on wall surface finished even and smooth without using extra cement complete all as specified and directed. |
| 46 | M&L for 10-12mm thick rendering with ready mix mortar of approved make on brick work or concrete surfaces on wall, finish the surface even and smooth without using extra cement as whole or in patch etc including taking down cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water and rubbish of the premises etc complete all as specified and directed. |
| 47 | M&L for Cutting holes in brick wall exc half bricks but not exc one brick in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified. |
| 48 | S&F Rolled Mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (beam, Tee, angle channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W (Gde E- 250 Quality 'B') complete all as specified and directed. |
| 49 | Dismantling of asbestos cement (corrugated semi corrugated sheet & ridge in roof covering complete all as specified and as directed. |
| 50 | S&F Pre painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 51 | M&L for pre painted galvalume aluminium Zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 52 | Dismantling timber scantlings 40 sq. cm and over in section for framed structure, in any position complete all as specified and as directed |
| 53 | M&L for PCC (1:3:6), type C-1 using 20mm graded stone aggregate as in filling of holdfasts complete all as specified and as directed. |
| 54 | M&L Preparing new surfaces of steel or iron of any description,not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 55 | M&L washing rubbing down and stopping of distempered and painted surfaces and applying two coat of Oil Bound Distemper on wall surfaces including proper curing all as specified and directed. |
| 56 | M&L washing rubbing down and stopping of Cement based painted surface and applying two coat of cement based paint on wall surfaces including proper curing all as specified and directed. |
| 57 | M&L for Preparation of new plastered surfaces wall and applying two coats of Oil bound distember over a coat of chalk whiting primer complete all as specified and directed. |
| 58 | Surface excavation in soft /loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed by Engr-in-Charge. |
| 59 | Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts wells cespits, manholes, pier holes etc n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 60 | Returning filling in layers including leveling watering and well ramming in layers n.exc 25 cm thick compelte all as specified and directed. |
| 61 | Removing surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 62 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in foundation filling, sub base for floors etc complete all as specified and directed by Engr-in-Charge. |
| 63 | Cutting hole in brick walls in cement mortar exc one brick but not exc two brick for fixing door frame and making good as required complete all as specified and directed. |
| 64 | Use & waste of formwork to sides of concrete foundations,footings,bases or column,raft and raft beams,sides and soffits if any of foundations and plinth beams and similar work,vertical or batter for flat rough finished surface of concrete complete all as specified and directed by Engr-in-Charge. |
| 65 | Use & waste of formwork to sides of pillars,posts,struts,piers,columns and stanchions etc rough finished for square/rectangular or polygonal surfaces of concrete complete all as specified and directed by Engr-in-Charge. |
| 66 | Use & waste of formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressummers, lintels, cantilever, shelves including supports, overhangs, etc also splays between floors and beams etc rough finished flat surfaces of concrete all as specified and directed |
| 67 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough flat finished surfaces of concrete complete all as specified and directed. |
| 68 | M&L for RCC (nominal mix) in (1:2:4) type B1 20mm graded stone aggregate as in foundations including rafts,footings,foundations beams ,bases of column etc complete all as specified and directed by Engr-in-Charge. |
| 69 | M&L for RCC (nominal mix) (1:2:4) type B1 20mm graded stone aggregate as in columns, pillars,piers,posts and struts etc complete all as specified and directed. |
| 70 | M&L for RCC(nominal mix) (1:2:4) type B1 20mm graded stone aggregate as in beams, cantilevers,bressummers,lintels over 1.5 m span complete all as specified and directed by Engr-in-Charge. |
| 71 | M&L for RCC(nominal mix) (1:2:4) type B1 20mm graded stone aggregate as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge. |
| 72 | M&L of TMT bars 10 mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 73 | Ditto all as per item No 72 above but 5 mm dia and over upto and including 10 mm dia in stirrups spaces and binders complete all as specified and directed. |
| 74 | M&L for 10mm thick cement plaster in cement mortar 1:6 on brickwork or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 75 | M&L 5 mm thick cement plaster in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement all as specified and directed by Engr-in-Charge. |
| 76 | M&L for hard core of broken stone or boulders gauge n.exc 63 mm deposited spread and leveled in layers n.exc 15 cm thick watered and ramed to a true surface complete all as specified and directed by Engr-in-Charge. |
| 77 | M&L for 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in sub base for floors etc complete all as specified and directed by Engr-in-Charge. |
| 78 | M&L for 50mm thick PCC(1:2:4) type B-1 (using 20mm graded stone aggregate) as in flooring complete all as specified and directed by Engr-in-Charge. |
| 79 | M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in sub base flooring complete all as specified and as directed. |
| 80 | M&L for Coloured Machine pressed cement concrete chequered tiles 30cm X 30cm X 20 mm thick machine pressed; set jointed and pointed in neat cement slurry in floors and cut and pointed with white cement and pigment over and including 15mm thick screed bedding layer in CM 1:6 including demolition of old chequered tiles all as specified and as directed. |
| 81 | M&L for cement concrete Type B-1, 1:2:4 (using 20mm graded crushed stone agg) in copings, kneelers, apex stones, bed plates, kerbs and the like incl weathering, slightly rounded or chamfered angles and throating, complete all as specified & directed . |
| 82 | S&F Solid PVC door frame of size 50x47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supplying and fixing as per specification complete all as specified and directed. |
| 83 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail either side & as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 84 | S&F 100mm butt hinges medium weight cold rolled fixed to doors with SS screws complete all as specified and directed. |
| 85 | S&F 150mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed. |
| 86 | S&F 125mm long aluminium handles cast type anodised ISI Marked complete all as specified and directed. |
| 87 | S&F anodised aluminium ventilator with aluminium anodised frame of aluminium section 62.50 mm x 37 mm x 1.5mm thick and with top hung shutter having style and rails of aluminium section 47.62 mm x 44.45 mm x 1.5 mm thick and shutter wire gauzed and bottom half portion of shutter fixed type and glazed glass pane without sash bars including necessary joining cleats,glazing clips,rubber packing, anodized, aluminium snap beading, screws, anodised aluminium fitting such as peg stays 150mm long, handles and 100mm long SS hinges etc complete all as specified and directed. |
| 88 | S&F Vitreous china white wash down water closet (pedestal pattern) including PVC seat cover and connection to drain or out going pipe and to flushing pipe anti-syphonage pipe etc, complete all as specified. |
| 89 | S&F 10 ltrs capacity PVC valveless syphonic action type low level flushing cistern complete with syphonic handle lever PVC bend including connecting to WC and fixing on walls with bracket all as specified. |
| 90 | S&F 15mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed by Engr-in-Charge. |
| 91 | S& F Bib tap of cast copper alloy brass but fancy type, Chromium plated 15mm bore, with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified. |
| 92 | S&F 500 litres capacity rotational moulded, triple layer polyethylene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roof including fittings complete all as specified and directed by Engineer in Charge. |
| 93 | S&F Gun-metal, globe or gate valves 20mm dia bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 94 | S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe (Minimum weight 210 gms) and fixed complete all as specified and directed by Engr-in-Charge. |
| 95 | S&F 600x450 mm beveled edge looking mirror of selected quality glass and backing with 6mm thick AC building board and fixed to wall with PVC rawl plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engr-in-Charge. |
| 96 | S&F 15mm bore stop/angle valve cast copper alloy with crutch or butterflty handle, screwed down screwed high pressure for iron pipe or for brass ferrule fancy type chromium plated with fancy shank and cup complete all as specified and directed by Engr-in-Charge. |
| 97 | S&F PVC Connection pipe, 450mm long, heavy duty with two sets of brass nuts & washers (one at each end) etc suitable for 15mm bore of pipe as in repair complete all as specified. |
| 98 | S&F 600 mm long towel rail of PTMT fixed to wall with steel screws and PVC rawl plug complete all as specified and directed. |
| 99 | S&F Health Faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed by Engr-in-Charge. |
| 100 | S&F Wash hand basin, flat back 550x400mm vitreous china (white) including PTMT waste fittings, 32mm bore size, waste pipe, PVC, 32mm bore, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing complete all as specified and directed by Engr-in-Charge. |
| 101 | S&F Vitreous China bowl urinal flat back, size of 465x355x265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, and flush pipe ) including waste pipe 32mm dia bore complete all as specified and directed by Engr-in-Charge. |
| 102 | S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engr-in-Charge. |
| 103 | S&F 110mm bore PVC (SWR) pipe of pressure not less than 4kg/sqcm in single socketed, in any length with rubber ring joints,fixed to wall including distance pieces and stack clamp with nuts and bolts complete all as specified and as directed. |
| 104 | S&F 110mm bore PVC (SWR) pipe of pressure not less than 4 Kg/Sqcm in single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed. |
| 105 | S&F 110mm bore, PVC (SWR) bends any radius complete all as specified. |
| 106 | S&F 110mm bore, PVC (SWR) branch piece, single (single T) equal or unequal with access door complete all as specified. |
| 107 | S&F 75mm bore PVC(SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed. |
| 108 | S&F 75mm bore PVC(SWR) bends any radius complete all as specified and directed. |
| 109 | S&F 110mm bore PVC (SWR) 'S' trap complete all as specified and as directed. |
| 110 | S&F galvanised steel water tubes 15 mm bore medium grade, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed by Engr-in-Charge. |
| 111 | S&F galvanised steel water tubes 20 mm bore medium grade, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed by Engr-in-Charge. |
| 112 | M&L for cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) in bed of drain pipe 200mm bore pipe including forming cradles at joints complete all as specified and as directed. Note : Thickness of bed below the barrel of pipes 100 mm for pipes 200mm dia and width D+300mm. |
| 113 | M&L for 200 mm nominal size Double wall corrugated HDPE pipes stiffness class SN 8 high density,polyethylene pipe resistent to chemicals,easy and light weighted,long living, low friction,flexible,sun resistant pipe and laid in trenches including taking down of any type of old pipe complete all as specified and as directed. |
| 114 | Cutting into existing manholes for connecting new drains 150mm dia,making good to pipe & rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished & reforming benching as required complete all as specified and directed by Engr-in-Charge. |
| 115 | M&L for Preparation of newly plastered surfaces of ceiling & applying three coats of white wash complete all as specified and directed. |
| 116 | M&L for applying two coat of Bitumen primer blown any grade, applied hot, to concrete surfaces at the rate of 1.5kg. per sq. m per coat APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. |
| 117 | M&L point wiring concealed in the wall with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing in & including rigid PVC conduit with replacement of sunken terminal MS boxes thickness and 3 mm thick hylam sheet cover for terminal boxes for including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following :- |
| 118 | (a) One light/fan point controlled by one by one way switch ( switch to be measured and paid separtely) |
| 119 | (b) One 3 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately. |
| 120 | (c) -ditto- as above item No 119 but Same board. |
| 121 | M&L point wiring with PVC unsheathed multi stranded copper conductor cable 4.00 sqmm FRLS 1100 Volts in New PVC concealed conduit medium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 4 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point omplete all as specified and directed. |
| 122 | M&L switch Modular type 6 Amp SP one way ISI marked complete all as specified and directed. |
| 123 | M&L switch Modular type type 16 Amp SP one way, ISI marked omplete all as specified and directed. |
| 124 | M&LModular type socket outlet 5 pin 6 Amp flush type, ISI marked omplete all as specified and directed. |
| 125 | M&L Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked omplete all as specified and directed. |
| 126 | M&L ceiling rose 3 terminals PVC polycorbonate,isolated body omplete all as specified and directed. |
| 127 | Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge. |
| 128 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 20000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level ≥ 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. |
| 129 | S & F pressure die cast aluminium housing LED street light luminaires with IP66 deg. of protection suitable for 35 watt LED fitting duly fixed on 40 mm dia GI mast including 50X 6 mm thick MS flat with suitable size of fastner including making connection flexible copper conductor cable from ceiling rose to fitting complete all as specified and directed..Note : The Contractor quoated the rates incl all accessories like suitable GI pipe mast, 50x6 mm thick MS flat, fashner, nut & bolts, suitable length of flexiable wire. |
| 130 | Provn of fresh air fan PVC body air delivery > 800 CMH , 5 number of blades, AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed by Engr-in-Charge. |
| 131 | Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets, regulators light fittings, conduits, sunken box, etc.) and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed. |
| 132 | M&L for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade conforming to IS:694 in new metal flush box of 1.6 mm thick including one coat of syenthetic enamelled black paint fixed with brass screws and cup washers including single core multi stranded FRLS copper conductor 2.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for one 3 Pin socket 15A Indepentent board |
| 133 | S&F of switch piano type 5 amps single pole one way complete all as specified and directed. |
| 134 | S&F of switch piano type 15 amps single pole one way complete all as specified and directed. |
| 135 | S&F of socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed. |
| 136 | S&F of socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed. |
| 137 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. all as specified and directed. |
| 138 | Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed. |
| 139 | Taking down of ceiling fan, dismantling of blades and depostit to MES store,Painting of ceiling fans complete, in-situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc., refixing of ceiling fan after completion of work complete all as specified and directed. |
| 140 | S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed.NOTE (a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 141 | S&F of factory made epoxy polyester powder coated VTPN MCCB distribution board 4 way with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates, 4 pole MCCB and ELM as incommer and SP MCBs as outgoings complete all as specified and conforming to IS: 8623 all as specified and directed.NOTE :-(a) MCBs/MCCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 142 | S&F in of MCCB 63 Amp 4 pole 16 KA at 415 V complete all as specified directed. |
| 143 | S&F of single pole MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed. |
| 144 | S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed. |
| 145 | S&F of SPN MCB 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed. |
| 146 | S&F in repair LED lights fitting 1x20Watt ,220V,AC decorative box type with driver,holder incl. LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 147 | S&F in repair LED lights fitting 1x9W/1x10W bulkhead luminaries incl. LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 148 | S&F surface mounting LED building security light fitting fitted in high pressure die cast aluminium housing not less than 35 W with IP 66 protection, including fabrication of GI bracket 25mm dia suitable for fixing of LED light fitting duly fixed with clamps, nut bolts & washer etc. . An operating voltage Range of 140-270V including all connection upto ceiling rose complete all as specified and directed. |
| 149 | S&F in repair sheet metal enclosure SP and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10 KA breaking capacity complete all as specified and directed. |
| 150 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail