| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ SSK/ Anchor/equivalent as directed by engineer incharge.) single core cable in surface / recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit/ duct( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.), with modular switch ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena / eq. make as directed by EIC.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ SSK/ Anchor/equivalent as directed by engineer incharge.) single core cable in surface/ recessed PVC conduit/ duct, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ SSK/Anchor make ) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit/ duct ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena / eq. make as directed by EIC.) |
| 5 | Wiring for 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ SSK/Anchor / eq. make as directed by EIC) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit/ duct( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena / eq. make as directed by EIC.) |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 8 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B, \\"C\\" curve including connections, painting etc. as required. |
| 9 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/ equivalent as directed by engineer incharge.), single core cable in surface/ recessed medium class PVC conduit as required. |
| 10 | (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 11 | ( c ) 2 X6 sq. mm + 1 X 6 sq. mm earth wire ( submain for emergency circuit) |
| 12 | ( d )2 X 10 sq. mm + 1 X 6 sq. mm earth wire ( Lighting submain/ three phase points) |
| 13 | (e) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire ( Heating Submain) |
| 14 | Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete |
| 15 | Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends. |
| 16 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 17 | Supply installation testing and commissioning of Indicator of Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena / eq. make as directed by EIC.) |
| 18 | Supply installation testing and commissioning of AC/DC Bell including Bell push and battries GM/ standard make |
| 19 | Sub Head-2 - Fixtures and Fittings |
| 20 | Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium body and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trulux /Wipro / eq. make as directed by EIC .sample to be approved before installation.. |
| 21 | S/F testing and comm. Of 20 Watt 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with THD<10%.( commercial series) Philips / Trulux/ wipro make/ eq. standard make as directed by engineer incharge. |
| 22 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan ( USHA/havell /Bajaj/Crompton/equivalent make as directed by engineer incharge,) with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 23 | Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Tivsha/schneider Livia /Havell Coral / eq. make as directed by EIC. |
| 24 | Supply installation testing and comm. Of 250mm -300mm sweep exhaust fan Shutter type of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections. |
| 25 | Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager / eq. make as directed by EIC) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 26 | 6 way (4 + 18), Double door |
| 27 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK / eq. make as directed by EIC) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 28 | 2 + 12 way, Double door |
| 29 | S/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ ABB ./equivalent make as directed by engineer incharge. |
| 30 | a) 6-32 Amp SP MCB |
| 31 | b) 40-63amp DP MCB |
| 32 | Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by8- 10 SWG G.I wire with 1/2\\" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound. |
| 33 | S/L , testing and commissioning of PVC XLPE insulated alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. |
| 34 | c)50 sq.mm 3.5 core |
| 35 | Earth work excavation for cable trench, 2 ft deep with an average breadth of 1.5ft and refilling of trench with excavated earth after laying of cable and ramming it properly excluding cost of cable.the job also includes laying of warning tape . |
| 36 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 37 | 160 mm dia (OD-160 mm & ID-135 mm nominal) |
| 38 | Supply installation testing and comm. of flood light 100 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell /Wipro/Crompton / eq. make as directed by EIC. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job. |
| 39 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) |
| 40 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 41 | Normal INCOMING: |
| 42 | a)160A 4P MCCB 25 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make. |
| 43 | b) 4 No. of Aluminium Bus Bar of 300 Amp. |
| 44 | c)Digital meters and phase indicators -1 set. |
| 45 | d) onload Change over switch 100 Amp for generator.Front operated. |
| 46 | e) 4 No. of Aluminium Bus Bar of 200 Amp. |
| 47 | c)Digital meters and phase indicators -1 set. |
| 48 | Inverter Incommer |
| 49 | (a) 100 amp DP MCCB 16 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB / eq. make as directed by EIC. |
| 50 | (b) 200 Amp 2 strip bus bar |
| 51 | c)Digital meters and phase indicators -1 set. |
| 52 | OUTGOING: |
| 53 | c) 40-63amp DP MCB |
| 54 | c) space for 24 way MCB's |
| 55 | Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical |
| 56 | S/I testing and comm. Of three phase 10 KVA 50HZ oil cooled(Transformer oil is to be provided with stabilizer conforming to IS 335,IEC296)) unbalanced type servo voltage stabilizer(A.E / Cosco/Chinar/ Electricfield / eq. make as directed by EIC) having an input voltage ranging from 156V to 415 V ( phase to phase) and balanced output voltage of 415V, +/- 1%. ( Test certificate to be provided by the manufacturer) The unit incorporate |
| 57 | a) 0-500V moving iron type voltmeter with selector switch. |
| 58 | b) A three phase change over switch to read voltage on incoming and output side |
| 59 | c) indicating lights 6 No two numbers for each of the motorised units, one for lower limit and other for higher limit. |
| 60 | d) six push button control for movement operation of three motorised dimmer units two for each unit i.e one for raise operation and one for lower operation under the conditions of adjustment of auto/mannual selector switch (DPDT) |
| 61 | e) Single phase Preventer ( contactor Switch of required rating) Legrand make. |
| 62 | f) six potential meter resistance with lock meter two for each phase control, one for sensitivity and other for level control. |
| 63 | g) two sets of indication lamps three numbers each to indicate output and input indication |
| 64 | h) 20 % over load bearing capacity for one hour. |
| 65 | Supply, installation, testing and commissioning of 75 inch 4K Ultra HD Interactive Flat panel Digital Board/ smart Board best for teaching screen, Display resolution Max. 3840x2160, anti glareglass, Multi touch screen, Stylus Dock, bluetooth, WIFI, USB, Ethernet, HDMI facility. samsung/Panasonic/LG make/ equivalent standard make ( sample to be approved before installation) ( 3 years onsite warranty) |
| 66 | Supplying, Laying and Drawing of UPT-4 pair CAT-6 LAN cable drawn partly in existing recessed/surface conduits, partly in xisting recessed/surface mounted raceways and partly in existing cable ducts in modular furniture complete as per specifications and as required. |
| 67 | Supply, Installation, Testing and Commissioning of 16 port Networking switck (Dlink/Eq make) |
| 68 | Supply, Installation, Testing and Commissioning of RJ 45 Data outlets with single back box of 27 Dlink/Legrend/siemens make with making of necessary connections through networing engineer and as required at site |
| 69 | Supply,Installation,Testing and Commissioning of CAT-6, 16 port jack panel for termination of CAT-6 cable, testing and certification of network with Omini penta scanner of each cable of reputed make as desired by EIC (HP/DIGISOL/D-LINK) |
| 70 | Supply,Installation,Testing & Commissionig of 9U Networking Racks(Fully Loaded)(HP/DIGISOL/D-LINK),Incl making of necessary connections |
| 71 | Supply, Installation, Testing & Commissioning of 5 KVA single-Phase IN single-Phase out ON Line UPS System to provide backup time of 30 minutes at full load, With In-Built Isolation Transformer of reputed make dully ISI Marked (APC Schineider/ETON/VERTIV/ equivalent standard make ) (Compitable to Genrator Supply having varing frequency) With on line double conversion topology, high frequency techonology, with front LCD,automatic bypass for fault tolerance & complete with required Number, 12 Volts 65 AH SMF VRLA Batteries( Exide/ Amaron/Quanta make) with connecting links with angle iron battery stand complete job, complete with battery rack with two year warranty against any manufacturing defect. The job further includes AMC for UPS and batteries for a period of three years with replacement warrenty reckoned from date of sucessfull commissioning. Please Enable Macros to View BoQ information |