| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVCinsulated copper conductor single core cable and 1.5sq.mm FRLS/HFFR PVC insulated copper conductorsingle core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling asrequired. |
| 3 | Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories insurface/recess including cutting the wall and making good the same in case of recessed conduit asrequired. (a) 20 mm |
| 4 | (b) 25 mm |
| 5 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover includingconnections etc. as required. (a) 5/6 amps switch |
| 6 | (b) 15/16 A switch |
| 7 | (c) 3 pin 5/6 A socket outlet |
| 8 | (d)6 pin 15/16 A socket outlet |
| 9 | Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit asrequired. (a) 3 x1.5 sq mm |
| 10 | (b) 3x2.5 sq.mm |
| 11 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitablesize of phenolic laminated sheet cover in frontincluding painting etc. as required. 180 mm X 100 mm X 60 mm deep |
| 12 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. asrequired. Upto 450 mm sweep |
| 13 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 12 way , Double door |
| 14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing andcommissioning etc. as required. Single pole |
| 15 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required. (a) 40 A |
| 16 | (b) 63 A |
| 17 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonryenclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. |
| 18 | Providing and laying earth connection from earthelectrode with 6 SWG dia G.I. Wire in 15 mm dia G.I.pipe from earth electrode including connection withG.I. thimble excavation and re-filling as required. |
| 19 | Providing and fixing 6 SWG dia G.I. wire on surfaceor in recess for loop earthing along with existingsurface/ recessed conduit/ submain wiring/ cable asrequired. |
| 20 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum) |
| 21 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 18- 22 Watt |
| 22 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and 85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)a. 50 watt. |
| 23 | Supply and fixing of brass batten/ angle holder including connection etc requried |
| 24 | Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required. |
| 25 | Rewinding of AC ceiling fan of all sizes and make including oiling, greasing as required New Model (Light Weight) |
| 26 | Replacement of ball bearing of size 117/120 NBC equivalent SKF make as required. |
| 27 | Replacement of fan condenser 2.5 mfd as required. |
| 28 | supply of 3mm thick phenolic laminated sheet as required |
| 29 | Supply of 9 Watt LED retrofit lamp suitable for B22 holder |
| 30 | Supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. a Single Phase 1.5 HP having discharge of 72 LPM Approx. at 49 M Head. |
| 31 | Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd. |
| 32 | Repair/Rewinding of existing 1HP mono block pump set including replacement of parts like gun metal bush/ bearing condenser, impeller etc to make the pump functional as required. |
| 33 | Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd. Please Enable Macros to View BoQ information |