| 1 | SCH 'A' PART-I: BUILDING/STRUCTURESNote: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 5 signifies this fact only |
| 2 | Construction of Pump House building complete all as shown on arch and structural drawings complete all as specified and directed. |
| 3 | Construction of Under Ground (UG) Sump of capacity 25000 Gallon complete all as shown on arch and structural drawings complete all as specified and directed. |
| 4 | NOTE: Schedule ‘A’ Part II to VIII items have been Prepriced by MES and the Bidders shall insert their lumpsum cost in green field under Column-6 only. |
| 5 | Total amount of Sch 'A' Part-II (EARTHWORK AND EXCAVATION, SITE CLEARANCE & DEVELOPMENT) |
| 6 | Total amount of Sch 'A' Part-III (B&R ITEMS) |
| 7 | Total amount of Sch 'A' Part-IV (INTERNAL ELECTRIFICATION) |
| 8 | Total amount of Sch 'A' Part-V (AIR CONDITIONING & REFRIGERATION) |
| 9 | Total amount of Sch 'A' Part-VI (FIRE FIGHTING SYSTEM) |
| 10 | Total amount of Sch 'A' Part-VII (EXTERNAL ELECTRIC SUPPLY) |
| 11 | Total amount of Sch 'A' Part-VIII (SEWAGE DISPOSAL) |
| 12 | NOTE: Items in Schedule ‘A’ Part II to X items which are not Prepriced by MES are given in Sch 'A' Part - IX & Sch 'A' Part -X, Bidders shall insert their rate in Column-6 only and the Estimated rate indicated as \\"0.0\\" are for that purpose. |
| 13 | SCHEDULE 'A' PART- IX (MEDICAL GAS PIPE LINE) |
| 14 | S&F DIN Type Oxygen Outlets with probe as Per standards DIN 13260 and EN 737-1 Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate etc complete all as specified and directed. Make : Altas Copco/Pneumatic Berlin/Tritech/REANIMED |
| 15 | S&F Main Oxygen Manifold of Size 2 x 4 for Indian type bulk cylinders, high pressure copper annealed flexible tail pipes complete with middle frame, chains for individual bulk oxygen cylinder, NRV's and 8 nos. pig tail pipes. It should be suitable to withstand a working pressure of 300 kg/cm2 and complete as specified and directed. It should confirm to HTM standard EN:13348:2016. Make - Aktiv /Tritech/Pneumatic Berlin |
| 16 | S&F Emergency Oxygen Manifold of Size 1 x 1 for Indian type bulk cylinders, high pressure copper annealed tail pipes complete with middle frame, chains for individual bulk oxygen cylinder, NRV's and 2 nos.pig tail pipes. It should be suitable to withstand a working pressure of 150 kg/cm2 and with MOX Regulator Single Stage Double Gauge 0-16 bar . It should confirm to HTM standard EN:13348:2016. Make - Aktiv/Tritech/Pneumatic Berlin |
| 17 | S&F Oxygen Fully Automatic Control 1350 LPM Panel, With Pneumatic Switch Over achieved Automatically, Automatic Reset for next cycle, Digital Pressure Indicator, Gas bank Status Indicator, Pressure Unit Options in bar, PSI and kg/cm2 as per HTM standard EN-13348:2016/Medical grade incl relief valve to bleed pressure built up excess of 5.2 bar (75 PSI) confirming to BSEN:ISO 7396-12016. Optimized Residual Gas. Make - Ohio/Aktiv /Atlas copco/Pneumatic Berlin |
| 18 | S&F Oxygen Flow Meter 0-15 LPM With Humdifier Bottle (autoclave) with all accessories matching probe/adaptor shall be provided at one end of oxygen gas outlets and other end for flow meter with standards of HTM 02-01 EN:13348 - Make - Atkiv/Gardner Denver/Atlas Copco |
| 19 | VACCUM SYSTEM |
| 20 | S&F DIN Type Vacuum Outlets with probe as Per standards DIN 13260 and ISO 7396-1 , Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate etc complete all as specified and directed. Make : Altas Copco/Pneumatic Berlin/Tritech/REANIMED |
| 21 | S & F ward vaccum regulator with an adjustable knob for precise vaccum control within a range of 0 to 760 mm hg with flow rate 25 LPM with collection jar 600ml made out of shatter proof, autoclavable polycarbonate with antibacterial filter as per ISO13485:2003 all as specified and directed. Make : Gardner Denver/Atlas Copco/Becker/Pneumatic Berlin |
| 22 | S & F ward vaccum regulator with an adjustable knob for precise vaccum control within a range of 0 to 760 mm hg with flow rate 25 LPM incl collection jar 1000 ml made out of shatter proof, autoclavable polycarbonate with antibacterial filter as per ISO13485:2003 all as specified and directed. Make : Gardner Denver/Atlas Copco/Becker/Pneumatic Berlin |
| 23 | S&F 3 HP Reciprocating, Tank Mount Vacuum Pump with Electricals and Anti-bacterial Filter. Tank Capacity 280 Ltrs. 1135 LPM, 40 cfm, Dimension (LxBxH in mm) - 1560 x 565 x 1115, Weight Approximate: 265 kg for comprising of following(a) No of cylinders=02(b) Vaccum=29.4 inch/745mmHg(c) Outlet size=25mm(d) Connection lead(e) Direct on line starter suitable for 3HP motor(f) Medical vaccum filter :Borosilicate filter element with 99.995% efficiency with extended aluminium alloy body with incl powder coating suitable for 25mm pipe connection. . Make Anest Iwata - Model - TVLS30D - 28E / Indo air/Frankair |
| 24 | COMPRESSED AIR SYSTEM |
| 25 | S&F DIN Type Air 4 bar Outlets with probe as Per standards DIN 13260 and ISO 7396-1, Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate etc. complete as required Make - Atkiv/Gardner Denver/Atlas Copco |
| 26 | S&F 3 HP Reciprocating Oil Free Air Cooled Tank Mount Air Compressor. Tank Capacity - 180 Ltrs. Single Stage, 14.6 cfm, Operating at 8.5 bar, Dimension (LxBxH in mm) - 1580 x 745 x 1000. Approximate Weight - 155 kg comprising of following(a) No of Stage=01(b) Outlet size=25mm(c) Direct on line starter suitable for 3HP motor . Make - Anest Iwata. Model TFS30C-9-18E/Indo Air/Frank Air |
| 27 | S&F breathing air system Air dryer of cap 10 CFM, with following operating condition. Make Trident/Draeger /OSHA |
| 28 | (i) Voltage : 100-240 V AC, 50/60 Hz 1 Ph(ii) Power consumption: 40 Watt(iii) Max working pressure :16 bar (g)(iv) Minimum working pressure: 4 bar (g)(v) Rated inlet Temperature: 38 degree centigrade(vi) Rated inlet pressure: 7 bar (g)(vii) CO level: 10 PPM (Alarm Set point) as per NFPA99(viii) Air quality : 2 degree Centigrade (POP) Pressure dew point. Alarm Set point as per NFPA 99 0.01 micron particle level.(ix) Cycle time: 4 min(x) The BAS should comprise of Prefilter of 5 micron, fine filter of 01 micron, Bacteria filter of 0.01 Micron.(xi) High quality carbon monoxide (CO) Monitor & Dew point monitor(xii) The Breathing dryer should meet breathing air standards as per NFPA 99, OSHA Grade D, European Pharmacopoeia & IS/ISO 7396The Dryer & filter should confirm ISO 87573 Class -2 (outlet air quality), 97/23/CE (pressure directive), 89/392/CEE (Machinery Directive), 72/23/CEE (Low voltage) & CRN (Clinical Research Nurse) |
| 29 | S&F Air Regulator (2 Nos) 0 - 10 kg/cm2 suitable for 1/4\\"-1/2 \\", 4\\" Analog Gauge 0-15 Kg cm2 with non return valves (NRV )=2 Nos) all as specified and directed Make ; Airmax Pneumatics /Kaymo/Atorse |
| 30 | S & F Three stage filtration system for medical compressed air system should be capable of arresting impurities at each stage with undermentioned phases.(a) PREFILTER made out of borosilicate element grade P)(Coalescing filter) to remove bulk liquid and large particles ,the filter should remove upto 5 Micron having green end cap(b)Stage-I: Vapour removal filter made out of borosilicate element grade X) separated filter for liquid droplets, particulate matter, upto 01 Micron . having end Red cap(c)Stage-2 made out of borosilicate element grade Y (Vapour element filter for remaining oil vapour &hydro carbon odours.particle remains upto 0.01 Micron . having end Cap-yellow.(d)Stage-3: borosilicate element grade A (high efficiency filter to remove bacteria,virus & other fine particulate matter ensuring the air is sterile,the particle remove less than 0.01Micron having Black End Cap - Make - Trident /OSHA/Draeger |
| 31 | Distribution Copper Pipe EN: 13348M & L Medical Grade copper pipe with required copper fittings, All pipes shall be drawn half hard temp., solid drawn, seamless, phosphorous deoxidised, non-arsenic and degreased copper pipe conforming to EN BS: 13348:2008. The supplies of copper pipe would be accompanied with manufacturers test certificate for the physical properties of copper pipes and their Chemical composition. The supply of pipes be further substantiated with inspection certificate from the third party like Lloyds Register. etc. complete as required. Note: (i) Painting of medical gas pipe line with approved colour as per medical gas code of practice is incl in unit rate. (ii) Oxygen & other gases reqd for welding / brazing is incl in unit rate (iii) Nylon saddles, coupler Tee, elbow & socket are incl in unit rate. (iv) Scaffolding & other support structure will be arranged by the contractor. |
| 32 | M & L Copper Pipe 12 mm X 0.7 mmThickness |
| 33 | M & L Copper Pipe 15 MM X 0.7 mm thickness |
| 34 | M & L Copper Pipe 22 MM X 0.9 mm thickness |
| 35 | M & L Copper Pipe 28 MM X 0.9 mm thickness Note for Item 15.00 to 18.00 : Make Mandev/Rajco/Maxflow |
| 36 | ISOLATION VALVES |
| 37 | S&F Isolation Ball Valve 12 MM With fittings confirming to HTM02-01 EN 13348 med grade with all accessories |
| 38 | S&F Isolation Ball Valve 15 MM With fittings confirming to HTM02-01 EN 13348 med grade with all accessories - |
| 39 | S&F Isolation Ball Valve 22 MM With fittings confirming to HTM02-01 EN 13348 med grade with all accessories - |
| 40 | S&F Isolation Ball Valve 28 MM With fittings confirming to HTM02-01 EN 13348 med grade with all accessories Note for Item 19.01 to 19.04 : Make-RB/CIM/Legris/Andco |
| 41 | DIGITAL ALARMSupply,installation,testing & commissioning 3 gas alarm panel for pressure/vaccum level of medical gases like oxygen,nitrogen oxide &medical air with both visual & andible alarm comprising of following.(i)colour coded LED’S (Green for normal,yellow for warning,red for alarm)(ii)Andible alarm with adjustable volume(minimum 85Db at 1mtr)with distinct tones (low pressure,high pressure,system fault)(iii)Wall mounting arrangements(iv)High impact flame retardant M S housing with smooth finish and anti bacterial coating(v)AC power with backup from UPS- Make - Ohio/Operista/Amico/Atlas Copco/Pneumatic Berlin |
| 42 | Horizontal Bed Head Panel *Supply, fix, test and commissioning of Bed Head Panel, 1800 MM long, Horizontal type. The Bed Head Panel after fabrication should be anodised and then powder coated as per the color recommended by the hospital. There will be airtight Bakelite partition to separate Gas outlet point and electrical switch socket. Each switch socket should be electrically connected and terminated into a terminal block. So that, only one connection of Phase, Neutral & earth will be required to energize the entire panel. Configuration• Oxygen Outlets = 1 No • MA-4 Outlets = 1 No. • Vacuum Outlets = 1 No • Electrical Switch & Sockets 5/15A= 8 No's.• RJ-45 = 1 No• Rj-11 = 1 No & PROVISION for Nurse Call.• Stainless steel Infusion pump mount with rail clamp = 1 No• Two ways extendable stainless steel IV hooks with rail clamp = 1 No• Stainless steel Basket with rail clamp = 1 No• Monitor tray with rail clamp = 1 No• Aluminium clamp for Ward Vacuum unit = 1 No S&F VDE 0834 certified /approved bed head connection module for Patient terminal for non voice connection module to connect patient hand set shall consist of 1xRJ45 socket marked in colour and with measures to ensure that the push button is properly connected incl the auto disconnected mechanism with antimicrobial coating .1x5 pole DIN socket for connecting a diagnostic device with disconnection call. Make : Atkiv/ModulSpace Technik /WIESPL /Tanvi Enterprises |
| 43 | M & L for metallic wall support for medical gas pipe lines of various sizes made out of 40mm X 40mm X 5MM angle iron fixed at equal interval of 1mtr on wall with double anchor fasteners of 10mm X 100mm.The copper tubes will be braced with flat iron clamps made out of 20mm flat iron bent to shape of respected dia of copper tubing with the help of nut bolts of suitable size. All metallic structure is to be printed with to coats of synthetic enamel paint over a coat of red oxide primer. all as specified directed (NOTE : The Wall supports for the gas pipe line are to be provided from Medical Gas Plant room to dead end of DMO Examination Room) |
| 44 | SCHEDULE 'A' PART- X (MISC B/R AND E/M WORKS) |
| 45 | B&R PORTIONS&F in repair shelves made of HDHMR (high density high moisture resistance) board manufactured with hard wood, prelaminated both sides white in colour 18mm thick water resistant, termite resistant, duly edge banded with PVC taping 0.8mm thick, cut to shape & size of shelves including taking down with existing one complete all as specified and as directed. |
| 46 | Supply and fixing in repair 18 mm thick UV board duly edge banded with 0.8 mm thick PVC taping for cup board shutters, shall be fixed with autoclosing hydraulic hinges and modular handles, design and colour as approved by GE, suitable for kitchen/ wash basin counter cabinet, etc including taking down old/ unservieable boards complete all as specified and as directed by Engr in charge (Make : Action tesa/ Kitply/ Archidlan) (Note: Auto close hydraulic Hinges shall be measured & Paid Separtely) |
| 47 | S&F stainless steel auto close/ hydraulic hinge suitable for shutter of not exc 0.50 sqm area complete all as specified and as directed. |
| 48 | S&F stainless steel hinge 50 mm long for cupboard shutter fixed with Self Tapping screws complete all as specified and as directed. |
| 49 | S&F 75 mm long stainless steel handles for cupboard shutter fixed with Self Tapping screws complete all as specified and as directed. |
| 50 | S&F Auto hinges, stainless steel, bright finish or electrogalvanised 30mm width of flaps complete all as specified and as directed. |
| 51 | S&F, Magnetic catches of brass body and striking plate in complete all as specified and as directed. |
| 52 | S & F in repair 5.50mm thick corner glass shelf with bracket etc complete all as specified and directed. |
| 53 | Supply & Fix 15 mm two in one angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make complete all as specified and directed |
| 54 | S&F in repair single lever basin mixer with popup waste system , Hot and Cold Facilites and 450 mm long braidaed hoses chromium plated complete all as specified and directed. |
| 55 | S&F in repairs single lever wall mixer with popup waste system, hot and cold facilites for 15 mm dia pipe and complete all specified and direcetd. |
| 56 | S&F in repair toilet paper holder with flap recessed type stainless steel Complete all as specified and directed complete all as specified and directed by Engr-in-Charge. |
| 57 | S&F in repairs elegent mirror PVC bathroom storeage cabinet of size 422x622mm, fixed with screws or PVC gutties, complete all as specified and directed. |
| 58 | M&L for Towel Ring of Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engr-in-Charge/GE |
| 59 | S & F in repair CP towel rail with lower hanger 630mm long ,ht-280mm and depth 140mm etc complete all as specified and directed. |
| 60 | S&F in repairs 15 mm angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make complete all as specified and directed. |
| 61 | S&F in repair MS powder coated 20 mm dia curtain rod including wooden polished brackets and wooden polished end knobs fixed with plugs & screws, complete all as specified and directed. |
| 62 | Taking down of existing tarfelt and cement plaster of any description and thickness on roof top including flashing and junction of parapet and cleaning existing roof top surface by brooming , wire brushing incl removing the debrish out complete all as specified and directed |
| 63 | Material and labour for complete removal of existing treatment from wall/ chajja/ roof projection surface by scrapping (nails, screws if any to be removed properly before scraping) to make the surface free from dust, loose paint and loose plaster to be completely removed by manually/mechnically means as directed by engr-in-charge and repair of external wall/Chajjas to be done with repair mortar to get even surface including preparation of old surface of wall/ceiling by filling cracks by crack fill paste good smoothen surface by sand paper and applying two coats of premium acrylic smooth exterior emulsion of approved colour with Excellent Dirt Pick up resistance with diluted with water as per manufacturer instructions applied over one coat of Smartcare Damp Prime Suprema Primer vertical walls with dilution of not more than 10% with forced coverage not more than 5 Sqm / Ltr as per manufacture's instruction and all coats incl primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI all as specified and directed. Allow 6-8 hrs to dry the surface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and directed |
| 64 | M&L for removing of existing plaster surface upto base level & cleaning the surface of roof/wall with wire brush with water throroughly to remove all dust/dirt and loose particles and applying 2 coats of damp proof 2K on an interval of 4 to 6 hrs (1st & 2nd coat should be perpendicular direction) as per manufacture instruction, after plaster the surface and apply painting to match the existing surface complete all as specified and approved by Accepting Officer |
| 65 | M&L for preparing old plastered/conrete surface of roof/wall with wire brush with water thoroughly to remove all dust/dirt and loose particles and applying 3 coats of Dr fixit New coat/Asian paint damp proof on roof/wall surfaces including crack seal sealent if required at crack portion of roof/wall allapplication as per manufacturer instruction and including warranty certificate provided by applicator/company. |
| 66 | M&L for Thorough cleaning work, removal of loose screed, repairing of the damaged portions. Making slope corrections and damaged portions near rain water outlet. Filling the annular space between concrete surface and rain water PVC pipe using non shrink grout after preparing the surface using sand paper and application of SBR Latex as a priming coat on the area. Mixing and pouring Conbextra GP2, high strength grout with clean and cool water at ratio of 0.16 on the prepared surface to make the bore packing water tight. The rate shall include necessay materials, tools and application procedure as per manufacturer's specification |
| 67 | M&L for preparing the surface, removal of loose particles, damaged portions and after jet wash the complete area. Opening the damaged joints, grinding those marked joints, applyhing bonding agent single component acrylic polymer emulsion designed as a curing membrane (VOC content of 13.5g / litre) further filling it with polymer repair dual shriknage repair mortar. Providing and laying shrinkage-controlled polymer modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar supplied in 25 kg moisture resistant bag when mixed with clean water at w:p ratio 0.18, achieves are as following: (a) Compressive strength shall have (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days,(b) Tensile Strength shall have (BS 6319 Pt.7) > 2.5 Mpa at 28 Days, (c) Flexural Strength shall have (BS 6319 Pt.3)>7 Mpa at 28 days, (d)Drying shrinkage to ASTM C 157-93, 28 days < 1000 microstrain capable of applying upto 50 mm thickness in single layer. (e) Shrinkage controlled, polymer modified, fibre reinforced cementitious repair morta shall have CE (CE29842) marking and compliance according to Construction Products Directive 89/106/EEC (CPD). |
| 68 | M&L for providing and application of protection system to external stone/concrete surface after proper surface preparation and cleaning to remove any laitance, algae, fungal, foreign materials using suitable repairing method followed by uniform application of colorless, ready-to-use, silicone water repellent silane-siloxane solution that penetrates porous substrates like brickwork, concrete, and stone, creating a water-repellent surface designed to reduce water and water-borne salt absorption, while still allowing water vapor to escape etc. complete including all tools and tackles as per manufacturers specification and as directed by EIC. (a) Product shall be complies with BS 6477-92 Class A and Class B as silicone-based water repellent |
| 69 | M&L for repair damaged chajja & honeycomb patches using ready to use repair mortar. Recommended Product: Polymer modified single component, alkaline resistant fibre reinforced, thixotropic, and cementitious patch repair mortar. Recommended product should achieve are as following: -(a) compressive strength shall have (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days,(b) Tensile Strength shall have (BS 6319 Pt.7) > 2.5 Mpa at 28 Days, (c) Flexural Strength shall have (BS 6319 Pt.3)>7 Mpa at 28 days, (d) Drying shrinkage to ASTM C 157-93, 28 days < 1000 microstrain. (e) Remove the loose particles, latiances and contamination if any. Mark the area to be patch repaired, Shrinkage controlled, polymer modified, fibre reinforced cementitious repair morta to be mixed with recommended quantity of water and apply to prepare surface and finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface etc., where the thickness of application is less than 50 mm in patches as per specification after applying bonding coat. (f) Shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar cement-based material should be cured immediately. Price considering thickness of repair 10mm. Curing to be executed by suitable curing compound. |
| 70 | S&F Aluminium Composit Panel (ACP) sheet with 1\\"x1.5\\" aluminium tube over the plain or semi circuler framed trusses / beam of gates including flat or sloped with circular or notching and waste on ACP cutting ,ACP shall meet undermentioned tech requirements. (i) Coating on front : high quality polymer resin.(ii) Core : FR Core (Fire retardant)(iii) Thickness : 4mm (iv) Weight : 7.50Kg/Sqm(v) Width: 1205mm(vi) Length: 2400 to 4880mm(vii) Structure: aluminium panel are protective film,clear coating PVDF,primer coating,antirust layer,aluminium skin and polyethylene.(v) Temp Resistance : Between -50C to +80CNote : Rate is deemded to be inclusive of scaffolding required and joint sealing |
| 71 | M&L for steel chromium plated letters or figures in Hindi& English (Indian) of appropriate shape & size as per site requirement and fix with appropriate material complete all as directed by Engineer-in-Charge |
| 72 | M&L for NDA logo of brass type/steel chromium plated approximate 2 feet height normally fix on wall/gate etc complete all as directed by Engineer-in-Charge. |
| 73 | M&L for 4 mm dia wire mesh 20 Gauge GI wire netting in 40X40X5mm MS angle frame fixeded to column etc complete all as specified and directed. |
| 74 | Supply & Installation of Sintex Prefabricated SMC Panel in the size of 2.00 mtr lengthX2.00 mtr width X 2.5 mtr height having 10KL Capacity (10000 Liter) broadly as per specification enclosed herewith Code No. GSPT-DP-10KL-2.0X2.0X2.5 MTRNote : Rate is deemded to be inclusive of Make arrangement of crane, lifter, safety precaution, scaffolding height upto 10.00 mtr etc. |
| 75 | INTERNAL ELECTRIFICATIONS & F RJ-11 telephone socket with transparent shutter 2 module alongwith flush metal box 2 module and front cover plate 2 module all as directed. |
| 76 | S &F for LAN RJ-45 Jack With Cat 6 socket UTP Cat with transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module all as directed. |
| 77 | S&F for TV socket with transparent shutter 1 module alongwith flush metal box 1 module and front cover plate 1 module all as directed. |
| 78 | S&F Modular USB Charger all as specified and directed by Engr-in-charge. Make: HavellsRoma/Vinay/Crabtree cat part no ACWKRXG002 |
| 79 | S&F LED ROJO 7 W B22 RED/GREEN LAMP all as specified and directed by Engr-in-Charge.Make- Havells-LHLDBWEB4P8R007 / Wipro/Luker. |
| 80 | S&F chandelier fitting Gold color brass materialb12 heads E14 cap type ø 610 x H920 with Chrome finish with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed by Engr-in-charge.Make- Jaguar - CHL-GLD-S1009A / Havells / Bajaj |
| 81 | S&F in replacement of honor board/Picture Light LED (warm white) fitting of 1x12 Watt individual LED lenses, chorme coloured complete all as specified and directed. |
| 82 | S&F in repairs surface /recess mounted with PC housing LED down lights 18 W LED 6500K, 240Volts and glare free symmetrical illumination suitable for POP ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. ceiling cutout ø 220mm,height ø 36mmNote: The quoted price shall include the cost of Light and its driver.Make: Havells -GLOWDLR18WLED830S/ Philps/Luker Please Enable Macros to View BoQ information |
| 83 | S&F in repairs surface /recess mounted with PC housing LED down lights 18 W LED 6500K, 240Volts and glare free symmetrical illumination suitable for POP ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. ceiling cutout ø 220mm,height ø 36mmNote: The quoted price shall include the cost of Light and its driver.Make: Havells -GLOWDLR18WLED830S/ Philps/Luker Please Enable Macros to View BoQ information |