| 1 | Wiring point for light point/ fan point /exhaust fan point/ call bell point with 1.5 sq. mm.FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit ,with modular type switch, phenolic laminated sheet , suitable size M. S. Box and earthing the point with 1.5 sqmm FRIS PVC insulated copper conductor single core cable etc. as required.( Group A) |
| 2 | Wiring for twin control light with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLSH PVC insulated copper conductor single core cable etc. as required. |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 4 | 2 X 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 5 | 2 X 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 6 | 2 X 4 sq. mm + 1 x 4 sq. mm earth wire |
| 7 | 2 X 6 sq. mm + 1 x 6 sq. mm earth wire |
| 8 | 2 X 16 sq. mm + 1 x 6 sq. mm earth wire |
| 9 | Supplying and fixing following sizes / modules ,GI box alongwith modular base & cover plate for modular switches in recess etc. as required |
| 10 | 200mm X 75 mm |
| 11 | 125mm X 125 mm |
| 12 | 200 mm X 150 mm |
| 13 | Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular type switch , connections painting etc. as required. |
| 14 | Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A &15 A modular socket outlet and 15/16 A modular type switch , connections painting etc. as required. |
| 15 | Supplying and fixing 3 pin, 5 A celling rose on the existing junction box/wooden block including connection etc. as required. |
| 16 | Supplying and fixing brass batten / angle holder including connection etc. as required. |
| 17 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 18 | Installation of exhaust fan/Fresh air fan in the existing opening, including making good the damage, connection, twsting, commissioning etc. as required. |
| 19 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 20 | 8 way, Double door |
| 21 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 22 | 12 way, Double door |
| 23 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Single Pole |
| 25 | Supply & fixing single pole blanking plate in the existing MCB DB comlete etc. as required. |
| 26 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 27 | Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 28 | for 10 way, Double door SPN MCB DB |
| 29 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 30 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 31 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required(For inverter wiring). |
| 32 | 1 X 1.5 sq. mm |
| 33 | Supply, installation, Testing and Commissioning of 1200mm sweep, BEE 5 star rated, ceilling fan with Brush Less direct current (BLDC) moter ,class of insulation ;B 3 no. blades ,30 cm long down rod, 2nos canopies , shackle rope, copper wiring , power facter not less than 0.9 , service value (CM/M/W) minimum 6.00 , AIR delivery miniimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374 -2019), THD less than 10% ,remte or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise =75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz , single phase AC Supply ,earthing etc.comple as required. |
| 34 | Supply of Heavy Duty Exhaust Fan 300 mm. sweep 900 RPM Single phase complete in all respect. Havells or Eq. |
| 35 | Supply of Metallic body fresh air fan 230 mm. sweep complete in all respect. Havells or Eq. |
| 36 | Supply and fixing of LED Bulb 7 W Havells or Eq. |
| 37 | LED Batten Light (System lumen efficacy > 120<135 lm/Watt ) Supplying, Installation, Testing and commissioning of LED Surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with driver efficiency >85%, Operating temp range -5 degree C to 40 degree , internal surge protection of 2.5 KV with Short and open circuit protection , THD <10% , PF > 0.95 ,IP20, CRI >80, Flicker free ( flicker should be below 5% ), life time (LED , Driver & electrical circuity ), of minimum 50000 Buring Hours with 70% of initial Lumen maintained till life ends, CCT 3000 K /4000 K /5700 K /6500 K ,SDCM <3 , Maxium power consunption should not more than the specified rating and fixture shall be relevant BIS standard . manufactures word Mark/ Name Engraved / Embossing / Screen printing on housing. complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR ,PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 year OEM warranty. System lumen efficacy >120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape,size and CCT shall be approved by ENC as per requirement. Powder coated die cast / Extruded aluminium Body (Thickness> 1.20mm) 18-22 Watt |
| 38 | Supply and fixing of water tight oblong 10 watt LED Bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection IK 08, High purity / transmisivity UV Stabilised non yellowish diffuser/ for uniform light distribution, detachble driver set open and short circuit protection suitable for 24 Hr Continuous operation , complete in all respect. CAT-AAA1200 system lumens, >120Im/W, PF>0.95, CRI>70, >300V over voltage protection 4KV internal surge protection metal housing with 5 year warrantee. |
| 39 | Supply and fixing of 32 Amp. DP MCB (10 KA) 240 V/415 V, 50 Hz, C-Series Havells or Eq. |
| 40 | Supply and fixing of 80 Amp. DP MCB (10 KA) 240 V/415 V, 50 Hz, C-Series Havells or Eq. |
| 41 | Supply and fixing of 100 Amp. DP MCB (10 KA) 240 V/415 V, 50 Hz, C-Series Havells or Eq. |
| 42 | Supply and fixing of DP metal encloser for MCCB, RCCB, RCBO Make:-Legrand, Havells or Eq. |
| 43 | Dismantalling of old wiring, Distribution & main switch etc. complete in all respect. |
| 44 | Cost of 01 No. Residence |
| 45 | Cost of 08 No. Residence Please Enable Macros to View BoQ information |