| 1 | Total amount of the \\"Rate Schedule\\" sheet SCHEDULE OF QUANTITY AND RATE FOR REPLACEMENT OF 11 KV CONDUCTOR BY 11 KV AAAC AL-59, 99 SQMM. COVERED CONDUCTOR OF 11 KV STATION FEEDER UNDER 33/11 KV SUB-STATION, RAIWALA UNDER EDSD, RAIWALA UNDER EDD, RISHIKESH AGAINST E-TENDER SPECIFICATION NO.96/EDCRDDUN/2025-26 Name of The Bidder's Firm: 0.0 Sl. No. Description of Work Unit Qty Rate Amount Part [A] (Supply Portion) |
| 2 | X-Arm Clamp for ST Pole SP-55 with N&B |
| 3 | PP & Clamp with N&B ST Pole SP-55 |
| 4 | Stay Clamp for SP-55 With Nut & Bolt |
| 5 | Distribution Box with N&B AB Cable 3 Phase - 4 Wire |
| 6 | Number Plate with Clamp |
| 7 | Danger Board with Clamp N&B Insulated PRC (IPC 95 sqmm.-95 sqmm.) Nos 45.0 0.0 |
| 8 | Connecting AB Cable to Distribution Box 1x25 sqmm. |
| 9 | IPC with Aluminium Bail for Earthing |
| 10 | 11 KV Cable Ties for Pin Insulator |
| 11 | 11 KV IPC for Covered to Covered Conductor |
| 12 | 11 KV IPC for Covered to Bare Conductor |
| 13 | 11 KV Mid Span Jointing Kit |
| 14 | 11 KV Tension With Bail and IPC |
| 15 | Disc Fitting 70 KN-D |
| 16 | 11 KV AAAC AL-59,99 sqmm. Covered Conductor Total - Part [A] 0.0 Part [B] (Labour Portion) |
| 17 | Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. wire as per construction manual. |
| 18 | Fabrication of MS Channel angle iron etc in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO schedule and local approced drawing. |
| 19 | Excavation of earth for stay pit of size 0.6x0.6x1.2 mtr in all types of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 20 | Fixing, tightening and nozzling of stay with pole and stay rod on required tension as per drawing/RESPO Manual |
| 21 | Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement,sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESPO Manual. |
| 22 | Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work |
| 23 | Erection of SP-55 single support pole in proper level and alignment along with fixing of all accessories like top channel & clamps a s per RESPO manual |
| 24 | Grouting of pole in size 0.45x0.45x1/9 of the support in CC ration 1:4:8(1 cement:4 graded stone20 mm niminal size: 8 coarse sand) block including cost of cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, levelling as per RESPO construction manual |
| 25 | Muffing of poles size 0.45x0.60 cm radius with 1:3:6(1 cement:3 coarse sand: 6 graded stone 10 mm nominal size) block size 45 cm height from ground level including cost of cement, stone and sand etc. |
| 26 | Painting of SP-55 pole with angle and channel and all steel part by one coat of Red Oxide Primer and two coats of aluminium Paint an d two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. From ground level. |
| 27 | Fixing of triangular type bracket in 11 KV line |
| 28 | Guarding of 33 KV Line.(max. 70 meter) over (Telephone/Road/L.T. line crossing as per drawing with 6/8 SWG G.I. wire including fixing of guarding channel/angle as per RESPO manual. |
| 29 | Providing and fixing of Danger Board and number plate complete by providing clamps of M.S. Flat 50x6 mm and Nuts & Bolts, danger Boards of M.S. Sheet 2 mm Thick 11''x7'' size (Including cost of all material) |
| 30 | Making of section pole for existing LT/HT/33KV line complete in all respect. |
| 31 | Cartage of ST pole SP-55 from store centre to construction site with loading, unloading at both points and proper stacking. (Distance 21-50 Km) |
| 32 | Cartage of other material (other than poles) by vehicle from Store Center to nearest construction site Store including loading and unloading at both ends (distance 21-50 Km) |
| 33 | Head load cartage of ST Pole SP-55 from road to site (distance 0-1 Km) |
| 34 | Head load cartage of small material (distance 0-1 Km) |
| 35 | Disconnecton and Reconnection of Consumer Connection |
| 36 | Straightning of Tilted ST Poles |
| 37 | Tightening of Stay Set |
| 38 | Resagging of LT AB Cable |
| 39 | Sagging/Resagging of ACSR/AB Cable LT line |
| 40 | Back Cartage of Petty Material, 0-20 Km. |
| 41 | Painting of Double Pole Struture of ST Pole SP-55/72 |
| 42 | Installation of LT Distribution Box |
| 43 | Fixing of IPC with Aluminium Bail for Earthing |
| 44 | Dismantling and Restringing of LT AB Cable |
| 45 | Opening and Making of Jumper of Section Pole |
| 46 | Fixing of 11 KV 90 KN Tension Clamp with Bail and IPC |
| 47 | Fixing of 11 KV Mid Span Jointing Kit |
| 48 | Back Head Load Cartage of Petty Material, 0-1 Km. |
| 49 | Fixing of 11 KV IPC For Covered to Covered Conductor |
| 50 | Fixing of 11 KV IPC for Ccovered to Bare Conductor |
| 51 | Grouting and Muffing of Poles |
| 52 | Laying, Spreading, Stringing of AAAC Conductor |
| 53 | 11 KV Cable Ties for Pin Insulator |
| 54 | Removing old Conductor by Opening Jumper |
| 55 | Weldin Rusted Pole |
| 56 | Lopping and Chopping of Tree Branches near HT/LT line Total - Part [B] 0.0 TOTAL [Part-(A) + Part (B)] 0.0 Place Date Superintending Engineer Please Enable Macros to View BoQ information |