| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE NEW DELHI Name of Work: PROVN OF WEATHER PROTECTION SHED ON TIGER GATE INCLUDING DEVELOPMENT OF GATE AND SURROUNDING AREA AT IHQ OF MOD (ARMY) TPT UNIT ASC UNDER GE NEW DELHI Contract No: GE/ND-108/2025-26 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | B&R PORTION:Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engr in charge. |
| 3 | M&L for brick work with sub class ‘B’ brick, straight or curved on plan exceeding 6m means radius in CM 1:6 with old size bricks complete all as specified and directed. |
| 4 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc and getting out in Soft/disintegrated rock complete all as specified and directed. |
| 5 | M&L for PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in copings,foundation, plinth course, damp proof course, bed blocks, benching, PCC cills and similar items complete all as specified and directed by Engr in charge. |
| 6 | Taking down cement or cement lime plaster any description incl racking out joints, hacking for key , scrubbing down with water etc including removal of debrish from the MOD land complete all as specified and directed by Engr in charge. |
| 7 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished using wpc @200 ml per bag of cement ( wpc to be paid measured and seperately) even and smooth without using extra ( Externally) complete all as specified and directed. |
| 8 | Supply only integral water proofing compound as per manufacturer instructions complete all as specified and directed. |
| 9 | M&L for Preparing newly plastered surfaces of walls and applying two coats of exterior emulsion paint (Apex) over a coat of primer and 2 to 3mm thich wall care putty complete all as specified and directed. |
| 10 | Dismantling structural steel work including doors, gates, framed trusses etc complete all as specified and directed. |
| 11 | M&L for Steel work in tubular trusses round or rectangular pipes including special shaped washer etc complete using ERW or induction butt welded tubes confrming IS complete all as specified and directed. |
| 12 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 13 | M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wind ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0 complete all as specified and directed. |
| 14 | S&F for 5mm thick polycoarbonate sheet of and colour having tensile as per manufacture instructions as in roof covering/cladding to wall fixed with self tapping screws as specified or as per manufacture instruction complete all as specified and directed. |
| 15 | Dismantling of semi corrugated or corrugated asbestos/fiber sheeting, any gauge and thickness including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 16 | S&F Pre- painted galvalume aluminum zinc coating GI based steel sheet with approved profile and 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge. Make:- TATA Bluescope, JINDAL, CRIL |
| 17 | M&L for Applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation on new steel surfaces any description, not otherwise described over 10 cm width or girth complete all as specified and directed. |
| 18 | Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for including cutting of reinforcement to facilitate demolition complete all as specified and directed. |
| 19 | M&L for Reinforced cement concrete 1:1.5:3 nominal mix, using 20mm crushed stone agg as in foundation, including rafts, footings,foundation beams, plinth beams, bases for columns etc complete all as specified and directed. |
| 20 | M&L for Reinforced cement concrete 1:1.5:3 nominal mix, using 20mm crushed stone agg as in columns etc complete all as specified and directed by Engr in charge. |
| 21 | M&L for Reinforced cement concrete 1:1.5:3 nominal mix, using 20mm crushed stone agg as in beams,roof beams, cantilevers,lintel over 1.5m span, bands, chajjas etc complete all as specified and directed. |
| 22 | Use and waste of form work to sides of concrete foundations footings base of columns, plinth beams ,raft and raft beams, sides ansd soffits of foundation complete all as specified and directed. |
| 23 | Use and waste of form work to sides of pillars, columns complete all as specified and directed. |
| 24 | Use and waste of form work to edges of concrete flats, treads breaks in floors, window cills,roof etc n exe 20 cm wide and sidesRCC/PCC bands in wall, horizental or slooping and similar work exe 5 cm but n exe 15 cm wide, fair finished surfaces of concrete complete all as specified and directed. |
| 25 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking bending spirally for hooping for coumns, hooking ends and binding with and includng mild steel wire (annealed) not les than 0.9 mm dia or secring with clips. (annealed) not less than 0.9mm dia, complete all as specified and directed. |
| 26 | S&F Mild steel TMT bars (conforming to Fe 500/Fe 550) 6 to 8mm dia in stirrups cut to lengths bent to shape required including cranking bending and spirally hooping for columns hooking ends and binding with MS wire annealed n.less then 0.90mm dia complete all as specified and directed. |
| 27 | S&F 10 mm thick pre coated Alluminium Composite Panel cladding sheet of approved colour and shape, joint filled with silicon sealant, fixed as per manufacturers instruction complete all as specified and directed. |
| 28 | Demolition of stone slab and tiles of any description or thickness on steps, jambs, pillars, walls, cooking platform, floors, aprons, skirting etc laid bedded and pointed in any mortar complete all as specified and directed |
| 29 | M&L for 20mm thick Granite (of any type and colour) work (table rubbed and polished) in jambs, pillars,and like in vertical surface in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 20mm thick screed in CM 1:4 complete all as spd and directed. |
| 30 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and directed. |
| 31 | M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 32 | M&L for vitrified ceramic coloured tiles 600mmx600mm 10mm thick as in floors, set and jointed with cement slurry and pointed with white or coloured cement to match with tiles over and including 15mm thick screed bed in cement mortar 1:6 including dismantling old unsv tiles and removal of rubbish outside MOD land complete all as specified and directed. |
| 33 | S&F stainless steel letters of font \\"Arial\\" or any other font as approved user in size 50cm x 30cm x 25mm thick made with 2mm thick stainless steel sheet matt finish with acrylic letter female part fitted into SS letters back incl backlit LED feature for illuminating letters fixed on composite panel faced wall with approved stainless steel screws and bolts for the letters in English/Hindi complete all as specified and directed. |
| 34 | M&L for outdoor tile parking tiles size 300 x 300 mm conforming to IS 15622:2017 including 20mm screed bed in CM 1:6 as in flooring over and including 75mm thick PCC 1:3:6 type C2 ( using 40mm graded aggregates) complete all as specified and directed. |
| 35 | E&M PORTION:S&F LED Flood light 80 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection ,system efficacy 110/120 lm/W, 4 kV in-built and 10 kV external surge protection incl connecting up with two core 1.5 sqmm coppper conductor complete all as specified and directed.Make: Bajaj GLEAM-XT F 96L WH NB-A3 PC SD ,Crompton Cat Part No- LFL-80-CDL/60-M, Orient Cat Part No-LFSMP-080-C-UHL. |
| 36 | S&F Gate lamp 45 Watt mounted on MS pipe and must be weather proof with IP 65 protection complete all as specified and directed.Make: Bajaj Cat Part No- BGCPNP 45W LED WW, Orient Cat Part No- LLPT-45-C, Havells Cat Part No- SIMBOLPT45WLED730SYMPCGRYCMP. |
| 37 | S&F factory made SPN DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way SPN 220 Volts, with suitable busbar, neutral link & earth link suitable for complete all as specified and directed.Make : Legrand, Schneider, L&T(LK), Indoasian. |
| 38 | S&F MCBs, SP 6 to 32 Amp, type B or C as per site requirement, 10 KA rupturing capacity, IS-8828 marked, and fixing in DBs (DBs Catered separately in this schedule) complete all as specified and directed.Note : Make of the MCB should be the same as that of DB |
| 39 | All as per item No 37.00 above but MCB DP 20 Amps Type B OR Type C as per site requirement complete all as specified and directed. |
| 40 | M&L for Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 specification at page 497 complete all as specified and directed by Engr in charge. |
| 41 | S&F and laying XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sqmm 3 core complete all as specified and directed by Engineer-in-Charge. Note:- Earth work incl excavation, returning filling, sand cushioning and removal if required or suggested by user and Engr-in-charge/fixing into wall or terrace or any type of surface by using suitable clamps shall be included in the quoted rate. Make: Gloster/Polycab/Havells. |
| 42 | M&L for Sub main wiring with two single core 1.5 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC conduit 25 mm dia including 1.5 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:-2(two) Runs of 1.50 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 1.50 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.Make of wire:- RR kabel ,Havells, KEI, Polycab, Finolex. |
| 43 | S&F LED flood fixture having Built-in Driver & constructions details as follows :: Housing: Die-cast aluminum & Optical Cover Tempered Glass. Product size not less than : D230 x H128mm. System lumen output ≥11000lm (Approx.) and a system wattage of ≤100W. The lifetime of ≥25,000 burning hours @ ta 35°C, Range of operating temperature should be from 0℃ to +35℃.Beam optics 90-110° The luminaire should have a color temperature of 3000K and CRI > 70. The luminaire shall meet Dust proof and water resistance IP66 & IK05 potection & voltage range protection from 140V-270V with 4kV internal (both CM/DM modes) with inbuilt 10KV SPD Surge protection. Power factor of ≥ 0.95. fixure must be in Compliance to IEC 60598-1, IS 10322 (Part5/Sec1) complete all as specified and directed by Engr in charge.Make: Philips Cat. no: BVP175 LED110 WW 100W FG GR PSU or equivalent in Jaquar,crompton. |
| 44 | S&F LED up & down Wall Mounted light fittings 8-10 watt with toughened clear/opal glass cover with two high efficiency LED modules (one upward & one downward light distribution), housing made of pressure die-cast aluminium body with powder coated finish, PF not less than 0.90, minimum IP 65 protection (dust & water proof), Luminous efficacy minimum 100 lumen per watt, CCT 3000K complete with mounting bracket, fixing screws, rawl plugs, internal wiring, connection to existing circuit including making good the disturbed surface complete all as specified and directed.Note:- Rate of 3 core 1.5 sqmm PVC insulated & sheathed copper cable with suitable size medium grade PVC conduit is included in unit rate quoted by contractor. Make: Philips Cat Part No 800042 Lucent Vertical 10 W or equivalent in Havells, CromptonNote: (a) Srl Item No 02.00, 06.00, 08.00, 10.00, 11.00, 13.00, 15.00, 24.00, 28.00, 32.00, 33.00, 34.00 & 43.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody.(b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |