| 1 | Labour for cleaning the work site before and after work etc. |
| 2 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance up to 50 M. including all lifts, levelling, ramming the foundation trenches removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. Extra for earthwork in hard soil as per specification & direction of E/I.(vide classification of soil item-B) |
| 3 | Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered ,rammed,fully compacted and fine dressed with earth obtained after cutting with lead a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I ( Mode of measurement compacted volume ) |
| 4 | Providing ,supplying & spreading of stone dust in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150 mm thick with all leads and lifts including cost of materials , labour, royality and taxes all complete as per specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150 mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification & direction of E/I. |
| 6 | Providing designation 75B one brick flat soling –do-- --do-- |
| 7 | Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:1.5:3 (1 Cement : 1.5 coarse sand zone(III): 3 graded stone aggregate 20mm nominal size) |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering shuttering, finishing and renforcement-all work up to plinth levelRCC 1:1.5:3 |
| 10 | Reinforced cement concrete work in wall , inluding attached pilaster, buttresses, plinth and string coarse, fillets,columns,pillars-----do-----do-------E/I RCC 1:1.5:3 |
| 11 | Providing Tor steel reinforcement of 8mm dia rods bars as per approved design and drawing –do-- --do—TMT Fe 500 (only valid for SAIL and TATA steel,JSPL,Electro steel Ltd and Vizal steel) +Providing Tor steel reinforcement of 10mm,12mm and 16mm dia bars as per approved design and drawing –do-- --do— |
| 12 | Providing Tor steel reinforcement of 8mm dia rods bars as per approved design and drawing –do-- --do—TMT Fe 500 (only valid for SAIL and TATA steel,JSPL,Electro steel Ltd and Vizal steel) +Providing Tor steel reinforcement of 10mm,12mm and 16mm dia bars as per approved design and drawing –do-- --do— |
| 13 | Providing Tor steel reinforcement of 8mm dia rods bars as per approved design and drawing –do-- --do—TMT Fe 500 (only valid for SAIL and TATA steel,JSPL,Electro steel Ltd and Vizal steel) +Providing Tor steel reinforcement of 10mm,12mm and 16mm dia bars as per approved design and drawing –do-- --do— |
| 14 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 15 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 16 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 17 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm)RIDGE PLAIN |
| 18 | Flashings/ Aprons.( Upto 600 mm) |
| 19 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 20 | Centering and shuttering including strutting,propping, etc and removal of form for foundation, footing, bases of column etc |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 22 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 23 | Supplying materials and labours for constructing inspection chamber of designation class 75B Bricks size750 mm deep,600 x450 internal dimension having 250 mm wall thickness in cement mortar (1:6) including 12 mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 X475 G.I cover with frame ( Weight not less than 36 kg) in foundation and refilling all complete as per specification and direction of E/I |
| 24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes |
| 25 | 20 mm nominal dia pipes |
| 26 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 27 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler 75 mm |
| 28 | Coupler 110 mm each |
| 29 | Single pushfit Coupler 75 mm |
| 30 | Single pushfit Coupler 110 mm |
| 31 | Single tee with door 75x75x75 mm |
| 32 | Single tee with door 110x110x110 mm |
| 33 | Single tee without door 75x75x75 mm |
| 34 | Single tee without doo 110x110x110 mm |
| 35 | Bend 87.5° 75 mm bend |
| 36 | Bend 87.5° 110 mm bend |
| 37 | Shoe (Plain) 75 mm Shoe each |
| 38 | Shoe (Plain) 110 mm Shoe |
| 39 | Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 40 | Providing, installing and fixing glow signboard of 20'x6'x6\\" size made with 4.0mm th HPL sheet and and framing of 35mmX35mm m.s. box section and 24\\" to 30\\" ht. aluminium channel box letter (all numbers and size, decided by engineer incharge/ Architect) with LED light including required electrical fittings and power supply system with all complete job and 5 years warranty.. |
| 41 | Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l. |
| 42 | Dismantling pcc work including …..E/I. |
| 43 | Sand (Lead Upto 49 km) |
| 44 | Stone dust (Lead 22KM) |
| 45 | Stone Chips (Lead 22KM) |
| 46 | Bricks 08 KM |
| 47 | Earth (Lead 01 KM) |
| 48 | Local Sand (Lead 18 KM) |
| 49 | Providing and laying 60mm thick factory made concrete interlocking pavour block of M-40 grade made by block making machine with strong vibratory compaction of approved size, design and shaped, laid in required colour and pattern over bed as per relevant IRC code filling the joints with fine sand etc all complete as per the direction of E/ |
| 50 | Granular Sub-Base with Coarse Graded Material (Table:-400-1) :-Construction of granular sub- base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. (For Grading-II Material) |
| 51 | Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\" x 4.5\\" x 3\\") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 52 | Filling in foundation trenches and plinth in layers not exceeding 150 mm thick well watered ,rammed,fully compacted and fine dressed with earth obtained after cutting with lead a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I ( Mode of measurement compacted volume ) |
| 53 | Providing and laying in position cement concrete of specified grade excluding the cost of Centering and shuttering-All work up to plinth level : 1:2:4 ( 1 cement:2 Coarse sand :4 graded stone aggregrate 20 mm nominal size ) |
| 54 | Providing designation 100 A Brick work wih fly ash lime brick (FLAG) confirming to IS 12894-1990 (12894-1990) (9\\" X 4.5\\"X3\\") in C:M (1:6) in foundation and plinth with aprroved quality of coarse clean sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints,cost of screening materials,rakingout joints of 15 mm depth ,curing taxes and royalty all complete as per building specification and direction of E/I |
| 55 | Providing tuck pointing (1:3) cement on brick work with clean coarse sand of F.M 1.5 including screeening,curing with all leads and lifts of water ,scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 56 | Providing 12 mm cement plaster (1:3) with clean coarse sand of F.M 1.5 including screeening,curing with all leads and lifts of water ,scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 57 | Providing 1.5 mm cement punning including curing ,carriage of water with all leads and lifts as per building specification and direction of E/I |
| 58 | Supplying,assembling ,lowering and fixing in vertical position in borewell unplasticized PVC Medium well screen (RMS) pipes with ribs, confirming to IS:12818,including hire and labour charges ,fitting and acessories etc all complete for all depth ,as per direction of Engineer in charge |
| 59 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge |
| 60 | Baic rate for 125/115 mm dia Drilled Tube well for drilling in all kinds of soil and rock for installation of hand pump with DTH ring Machine all complete including supplying all materials,labours,tools ,drilling,rigs ,air compressors and equipments as well as fuel lubricant,for making 125/1115 mm dia boring etc . and cost of transporting rig machine and other vehicle upto site of work as per specification and direction of E ngineer in charge |
| 61 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 62 | Reinforced cement concrete work in beams, suspended floors, foors having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staicases and spiral stair cases above plinth level up to floor five lvevel, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20mm nominal size). |
| 63 | Cemtering and shuttering including struting,propping etc and removal of form for slab |
| 64 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimension 455 X 610 mm and 45 cm deep for single pipe line with common burnt clay F.P.S (non Modular) and brick designiation 7.5 |
| 65 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :100 mm dia RCC Pipe |
| 66 | 150 mm dia Pipe |
| 67 | Supplying and fitting Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire mesh 0.63mm |
| 68 | Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M below G.L. |
| 69 | (b) From 51.0 M to 150.00 M |
| 70 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 71 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 72 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 73 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 74 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP |
| 75 | Supplying,fitting and fixing panel board with MCB Voltmeter main with starter having starting capacity and running capacity with indicator etc all complete as per specification RATE FROM ROTARY PARK |
| 76 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable |
| 77 | Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I. |
| 78 | Providing 12mm Thick cement plaster(1:4)-do- |
| 79 | Providing and laying damp proof course 50 mm thick with cement concrete 1:2:4 (1cement : 2 coarse sand (zone-lll) : 4 graded stone aggregate 20 mm nominal size). |
| 80 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I. |
| 81 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 82 | Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 83 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 84 | Supplying , fitting and fixing collapsible gate of apporoved size and make properly fabricated with vertical double channels 20x10x2 mm. at 100mm. Centres and braced with M.S flat diagonals 20 x 3 mm,with top and bottom rails of T. iron 40x40x6 mm with 38 mm dia steel pulleys complete with bolts nuts, locking arrangements stoppers, handles, including applying a primer coat of led paint carriage hosting and taxes all complete as per building specification and direction of E/I. |
| 85 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 86 | Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysuiphide Sealant (Porin.g Grade)as per drawings and technical specificationsi6nd direction of E in Charge. (with 18% GST) B rand Sika Polysulphide, Fosrpc-Thioflex 600 Dr. Fixit Pidiseal PS(42P. MY K Seal PS or Euivalent. |
| 87 | Finishing wall with Premium Acrylic smooth exterior paint with silicone additives of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 90 litre/10sqm) |
| 88 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 89 | Supplying and drawing 2X 1.5 sq.mm sizes FR PVC insulated,single core cable in the existing /recessed steel/PVC conduit as required JSR 1.15 |
| 90 | Supplying and fixing of following piano switch /socket on the existing switch box/cover including connection etc. as required JSR 1.235/6 amps , one way switch |
| 91 | Supplying and fixing of following piano switch /socket on the existing switch box/cover including connection etc. as required JSR 1.235/6 amps, 3 pin socket outlet |
| 92 | supplying and fixing of 2 pin 5 amp. Ceiling rose on the existing junction box/ wooen block including connection etc. as required |
| 93 | Supplying and fixing 12 Module size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required |
| 94 | Supplying and fixing of 20 mm sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required |
| 95 | Supplying and fixing of 170mm x 221mm x 48mm deep (8\\"x 10\\") sizes of PVC/G.I box on surface / recesswith suitable size of phenolic laminated sheet cover in front including painting etc. as required. JSR 1.22.8 |
| 96 | S.I.T.C of 20W LED Tubelightrating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. JSR 9.5 |
| 97 | PVC/XLPE insulated PVC sheathedheavy duty, armoured electrical cable with aluminium conductor for working voltage up to and including L100 volts. (Conforms to IS:1554,part-1)10 sq. mm,2 core(For Street Light & Shop Connection) |
| 98 | PVC/XLPE insulated PVC sheathedheavy duty, armoured electrical cable with aluminium conductor for working voltage up to and including L100 volts. (Conforms to IS:1554,part-1)16 sq. mm, 4 core(For Street Light & Shop Connection) |
| 99 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 100 | Supplying and fixing following way, single pole and neutral, sheet steel,MCB distribution board, 240 volts, on surface/ recess, compiete with tinnedcopper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)12way, Double door |
| 101 | S/F T.P. MCB DB :-Supplying and fixing following way, horizontal type three pole and neutral,lsheet steel, MCB distribution board, 415 volts, on surface/ recess, completewith tinned copper bus bar, neutral bus bat earth bar, din bar,interconnections, powder painted including earthing etc. as required. (Butwithout MCB/ RCCB/ Isolator)4 way (4 + 12), Dorrble door, Horizontal type |
| 102 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, \\"C\\" curve,miniature circuit breaker suitable for.inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required6/32 amps, Single Pole |
| 103 | S/F rewireable double pole/ TP&N switch disconnector :-Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board . making connections. etc. as required63 amps, TP&N |
| 104 | S/F rewireable double pole/ TP&N switch disconnector :-Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board . making connections. etc. as required32 amps, double Pole |
| 105 | 7 Mtr. height Octagonal Hot - Dip galvanized pole( BOP - 7030) with top dia 70 mm, bottom dia L30 mm & made of 3 mm thick sheet, base plate dimensions200X 200X12mm ( Lx B xT) including suitable sizes of foundation bolt all complete as reqd. (Without Arm) |
| 106 | lnstallation, Testing & Commissioning of the 7 Mtr. Octagonal Pole &light fitting with the help of suitable tools and plants, and constructionof shallow foundation with M25 grade concrete considering safe soilbearing capacity of 10T/mhs sq. but excluding wire and MCB |
| 107 | 1 m Double Arm suitbale for 70mm Top |
| 108 | 1 m Single Arm suitbale for 70mm Top |
| 109 | LED STREET Light (90W) |
| 110 | Earthing with G.l. earth pipe 4.5 mtr long. 40mm dia including, accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc, with charcoal and salt as required. |
| 111 | Outdoor stand mounted Feeder Panel with 32amp TP&N, MCB incomer, 45amp TP contactor automatic switching of luminaries, power tool control incommer outgoing terminal etc as reqd. |
| 112 | Good & Service Tax (GST) |
| 113 | Labour Cess Please Enable Macros to View BoQ information |