Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil Work WORKS (PART-I)Earthwork in excavation of foundation in all kind of soil (Hard Soil & Ordinary Soil) within 50m initial lead and 1.5m, initial lift including shoring,shuttering, propping bullahs, piling,dewatering from foundation, with & working pumps & staking the excaveted materials away from the working area including rough dressing the bed and foundation tranches to required size including cost, conveyance, taxes, cess, royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 2 | Supplying and filling in foundation and plinths with sand well watered and compacted including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, watering, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge. |
| 3 | Filling foundation and plinth with excavated earth ramming etc complete as per approved drawing and technical specifications complete in all respect & as per direction of the Engineer-in-Charge. |
| 4 | Providing and laying plain cement concrete (1:3:6)(using branded cement) in foundation using 40 mm size hard crusher broken granite metal of approved quality from approved quarry including mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period including cost of all material, labour, conveyance, loading and unloading, taxes,cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc. ,complete as per the direction of the Engineer-in-charge. |
| 5 | Providing lifting , hoisting and laying Reinforced Cement Concrete of M 25 grade(using branded cement) to the following structural member or in places as shown in the drawing for all floors with 20 mm and down graded size hard crusher broken granite chips of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumb and finishing the exposed surfaces smooth (if required by grouting / providing plaster with cement mortar 1:4 wherever necesary without any extra cost) scaffolding, including watering and curing for the required period including providing strong, rigid, levelled and plumbed centring and shuttering to required shape and size, for floors with wood/Steel centring materials, with all necessary bracing and ties and supports pockets for electrical conduits, pipes, PH pipes, for hooks or boxes, switchboards and insert plates, clamps and extension bars, etc, including dismantling the same after the required interval from the date of casting, including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering,curing, sundries. tools and plants etc. complete as per direction of the engineer-in-charge, but excluding cost of steel reinforcement.a) Column Base Footing |
| 6 | ii) R.C.C Plinth Beam |
| 7 | iii) R.C.C Column & Beam in Superstructurea) Ground Floor |
| 8 | b) 1st Floor |
| 9 | c) 2nd Floor |
| 10 | d) 3rd Floor |
| 11 | e) 4th Floor (Head Room) |
| 12 | iv) R.C.C Lintela) Ground Floor |
| 13 | b) 1st Floor |
| 14 | c) 2nd Floor |
| 15 | d) 3rd Floor |
| 16 | e) 4th Floor (Head Room) |
| 17 | v) R.C.C Chajja (6.5 cm average thick)a) Ground Floor |
| 18 | b) 1st Floor |
| 19 | c) 2nd Floor |
| 20 | d) 3rd Floor |
| 21 | e) 4th Floor (Head Room) |
| 22 | vi) R.C.C Staircasea) Ground Floor |
| 23 | b) 1st Floor |
| 24 | c) 2nd Floor |
| 25 | d) 3rd Floor |
| 26 | v) R.C.C Shelvesa) 1st Floor |
| 27 | b) 2nd Floor |
| 28 | c) 3rd Floor |
| 29 | vii) R.C.C Roof Slaba) Ground Floor |
| 30 | b) 1st Floor |
| 31 | c) 2nd Floor |
| 32 | d) 3rd Floor |
| 33 | e) 4th Floor (Head Room) |
| 34 | vi) R.C.C Fina) 1st Floor |
| 35 | b) 2nd Floor |
| 36 | c) 3rd Floor |
| 37 | Fly Ash brick masonry in cement mortar (1:6) (Using Branded Cement) in foundation & plinth using Fly Ash bricks of 23x11x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per specification & direction of Engineer-in-charge. |
| 38 | Providing Fly Ash brick masonry work in super structure using 23 X 11 X 8 cm (with dimensional tolerance of ± 2% ) Fly Ash bricks having crushing strength not less than 75 kg. / sq cm, mortar of mix 1:6 (1 cement : 6 sand),(using branded cement) immersing the bricks for minimum 6 hrs in water before use, with all necessary projections, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc., complete as per the direction of the Engineer-in-charge.a) Ground Floor |
| 39 | b) 1st Floor |
| 40 | c) 2nd Floor |
| 41 | d) 3rd Floor |
| 42 | e) 4th Floor (Head Room) |
| 43 | Providing Fly Ash brick masonry work in super structure using 23 X 11 X 8 cm (with dimensional tolerance of ± 2% ) Fly Ash bricks having crushing strength not less than 75 kg. / sq cm, mortar of mix 1:4 (1 cement : 4 sand),(using branded cement) immersing the bricks for minimum 6 hrs in water before use, with all necessary projections, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc., complete as per the direction of the Engineer-in-charge.a) 1st Floor |
| 44 | b) 2nd Floor |
| 45 | c) 3rd Floor |
| 46 | Supplying steel i.e. Tor Steel / HYSD Bars conforming IS-1786 including straightening, cutting, bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (Linear measurement will be taken and quantity will be calculated on standard weight of tor steel / HYSD bars for all heights) complete as per specification & direction of Engineer-in-charge.a) Ground Floor |
| 47 | b) 1st Floor |
| 48 | c) 2nd Floor |
| 49 | d) 3rd Floor |
| 50 | e) 4th Floor (Head Room) |
| 51 | Providing 12 mm thick cement mortar 1:6 (1 cement : 6 sand )(using branded cement) to outside surface / plumbed surface of masonry, raking out joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing grooves or beads where ever necessary, including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering. curing, sundries, tools and plants etc. complete as per the direction of the Engineer-in-charge.a) Ground Floor |
| 52 | b) 1st Floor |
| 53 | c) 2nd Floor |
| 54 | d) 3rd Floor |
| 55 | e) 4th Floor (Head Room) |
| 56 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) (Using Branded Cement) with screened and washed sharp sand for mortar and finished smooth to the inside rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves or beads where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as per specification & direction of Engineer-in-charge.a) Ground Floor |
| 57 | b) 1st Floor |
| 58 | c) 2nd Floor |
| 59 | d) 3rd Floor |
| 60 | e) 4th Floor (Head Room) |
| 61 | Providing 6 mm thick cement plaster (1:4)(1 cement : 4 sand ) (using branded cement)to RCC surfaces finished smooth including closed deep chiping and slury treatment., raking out joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing grooves or beads where ever necessary, including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering. curing, sundries, tools and plants etc. complete as per the direction of the Engineer-in-charge.a) Ground Floor |
| 62 | b) 1st Floor |
| 63 | c) 2nd Floor |
| 64 | d) 3rd Floor |
| 65 | e) 4th Floor (Head Room) |
| 66 | Providing 20 mm thick cement plaster (1:4)(1 cement : 4 sand ) (using branded cement)to RCC surfaces finished smooth including closed deep chiping and slury treatment., raking out joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing grooves or beads where ever necessary, including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering. curing, sundries, tools and plants etc. complete as per the direction of the Engineer-in-charge.a) 4th Floor (Head Room) |
| 67 | Supplying, fitting and fixing Industrial vitrified tiles in floor treads or steps and landing of premium grade having thickness 8mm to 10mm of size 300mm x 300mm confirming to IS 4457 of approved make on 20mm thick bed of C.M. (1:4) (Using Branded Cement) including cost of all materials, taxes, cess, labour, T&P etc. required for the work in all respect as per specification & direction of Engineer-in-charge.a) Ground Floor |
| 68 | Supplying, fitting and fixing vitrified tiles of premium grade having thickness 10mm confirming to IS 13755 of size 600mm x 600mm Coloured / Printed series (homogenious) of approved make a shade (Orient Bell, Somany, Kajaria, Johnson) in floors on 20mm thick bed of C.M. (1:4) (Using Branded Cement) and filling the joint with white cement mixed with pigment to match the shades of the tile including washing and cleaning with oxalic acid complete including cost of all materials, taxes, labour, labour cess, T&P etc. required for the work complete in all respect as per specification & direction of Engineer-in-charge.a) 1st Floor |
| 69 | b) 2nd Floor |
| 70 | c) 3rd Floor |
| 71 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 10mm confirming to IS 13756 of size 600mm x 600mm Coloured / Printed series (homogenious) of approved make (Orient Bell, Somany, Kajaria, Johnson) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) (Using Branded Cement) jointed with neat cement mixed with pigment to match the shades of the tiles including washing and cleaning with oxalic acid and polishing etc. complete with cost, conveyance, royalties and taxes of all materials all labour,labour cess complete in all respects as per specification & direction of Engineer-in-charge.a) Ground Floor |
| 72 | b) 2nd Floor |
| 73 | c) 3rd Floor |
| 74 | Providing Granite Tiles of sizes Above 0.40 Sqm. (20mm thick) of approved make and shade, dressed, rubbed and polished, bottom coated with neat cement slurry in Stair case, Tread, Riser, Landing, Kitchen Slab Floors fixed with neat cement slurry, over 25 mm thick cement mortar (1:1)(1 cement : 1 sand) (Using Branded Cement) to masonry or concrete surfaces to proper level / slope and joints filled with cement mixed with matching colour in required proportion, polishing, washing and acid cleaning, including cost of all materials, conveyance, royalties, taxes, cess, labour, scaffolding, watering, curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge.a) Ground Floor |
| 75 | b) 1st Floor |
| 76 | c) 2nd Floor |
| 77 | d) 3rd Floor |
| 78 | e) 4th Floor (Head Room) |
| 79 | Providing Granite Tiles of sizes Above 0.40 Sqm. (20mm thick) of approved make and shade, dressed, rubbed and polished, bottom coated with neat cement slurry in dado skirting & risers of steps fixed with neat cement slurry, on 12 mm thick cement mortar (1:3)(1 cement : 3 sand) (Using Branded Cement) to masonry or concrete surfaces to proper level / slope and jointed with cement slurry mixed with matching colour in required proportion, polishing, washing and acid cleaning, including cost of all materials, conveyance, royalties, taxes, cess, labour, scaffolding, watering, curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge.a) Ground Floor |
| 80 | b) 1st Floor |
| 81 | c) 2nd Floor |
| 82 | d) 3rd Floor |
| 83 | Providing (20cm x 30cm / 20cm x 20cm)size special plain/printed series Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of approved make and shade in dado/skirting and rises of steps to any height in all floors, fixed with neat cement slurry, after soaking the tiles in water, over 12 mm thick cement mortar (1:3)(1 cement : 3 sand) (Using Branded Cement) mix, joint pointed with white cement mixed with matching pigment to match the shade of the tiles , including washing and cleaning with oxalic acid, including cost of all materials, conveyance, royalties, taxes, cess, labour, scaffolding, watering, curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge.a) Ground Floor |
| 84 | b) 1st Floor |
| 85 | c) 2nd Floor |
| 86 | d) 3rd Floor |
| 87 | Providing and fixing 65mm X 125mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.(Make: WPC Door Frame: Century/Black Cobra/Rajshri Plastiwood,Colour:Coffee Brown)Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.a) 1st Floor |
| 88 | b) 2nd Floor |
| 89 | c) 3rd Floor |
| 90 | d) 4th Floor (Head Room) |
| 91 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fitting and fixture complete etc including cost of all materials, hardware fittings, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, sundries, tools and plants etc. complete as per the direction of the Engineer-in-charge.a) 1st Floor |
| 92 | b) 2nd Floor |
| 93 | c) 3rd Floor |
| 94 | Supplying & fitting, fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VEKA LTD) Three track three panel sliding window-60-series duly Manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and window sash of 39mm x 58mm x 2.5mm capable of mounting single glazing system structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window frame shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using Reinforced large coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost & conveyance of all materials acessories labour charges, Cess, taxes of all materials & product conforming to ASTM D 638-14 EN-477-95 and other applicable codes and standards.A) First Floor |
| 95 | b) 2nd Floor |
| 96 | c) 3rd Floor |
| 97 | Supplying & fitting, fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VEKA LTD) Ventilator / Top Hung-60-series duly Manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames, 75mm x 60mm x 2.25mm for casement Windows Sash Profile capable of mounting single glazing system structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window sash shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost & conveyance of all materials acessories labour charges, Cess, taxes of all materials & product conforming to ASTM D 638-14 EN-477-95 and other applicable codes and standards.a) 1st Floor |
| 98 | b) 2nd Floor |
| 99 | c) 3rd Floor |
| 100 | d) 4th Floor (Head Room) |
| 101 | Supplying, Fitting & Fixing M.S. Grill, Grills gates, MS gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of MS Square bar / flat including stair case hand railing with 40mm dia GI pipe etc. including drilling holes in walls priming the grill with red oxide primer including cost ,conveyance, taxes of all material, labour ,cess required for the work complete as per the direction of the Engineer-in-charge.a) Ground Floor |
| 102 | b) 1st Floor |
| 103 | c) 2nd Floor |
| 104 | d) 3rd Floor |
| 105 | e) 4th Floor (Head Room) |
| 106 | Providing and applying Distempering with approved quality Distemper mix with adhesive of required amount to the interior plastered surfaces at all levels and heights by applying 2 coats using the required quantity of Distemper as specified by the manufacturer to give an even shade over a coat of water bound cement primer, watering the surface before applying and curing for the required period, including cleaning and smoothening the surface thoroughly including cost of all materials, labour, conveyance, taxes, cess, royalties, scaffolding, watering, curing, tools and plants, etc., complete as per the direction of the Engineer-in-charge.a) Ground Floor |
| 107 | b) 1st Floor |
| 108 | c) 2nd Floor |
| 109 | d) 3rd Floor |
| 110 | e) 4th Floor (Head Room) |
| 111 | Finishing wall surface with painting two coats with Weather coat paint (1st quality) exterior grade over a coat of Cement Primer (Water based) of approved make & approved shade to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cess, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.a) Ground Floor |
| 112 | b) 1st Floor |
| 113 | c) 2nd Floor |
| 114 | d) 3rd Floor |
| 115 | e) 4th Floor (Head Room) |
| 116 | Painting two coats with Synthetic enamel paint of approved quality and shade over a coat of primer (Red Oxide Primer) on surfaces as specified below Steel Surface) to give an even shade with 2 coats of approved quality paint, including cost of all materials, labour, conveyance, taxes, cess, royalties, scaffolding. watering, curing, sundries. tools and plants, etc., complete as per the direction of the Engineer-in-charge.a) Ground Floor |
| 117 | b) 1st Floor |
| 118 | c) 2nd Floor |
| 119 | d) 3rd Floor |
| 120 | e) 4th Floor (Head Room) |
| 121 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per specification & direction of the Engineer-in-charge.a) Ground Floor |
| 122 | b) 1st Floor |
| 123 | c) 2nd Floor |
| 124 | d) 3rd Floor |
| 125 | e) 4th Floor (Head Room) |
| 126 | Providing, Fitting & Fixing of 100 mm dia PVC Rain water pipe including drilling holes in Bricks / Concrete wall with cost, conveyance, royalties of all materials with cost of all labour,labour cess, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.a) Ground Floor |
| 127 | b) 1st Floor |
| 128 | c) 2nd Floor |
| 129 | d) 3rd Floor |
| 130 | e) 4th Floor (Head Room) |
| 131 | P.H WORKS (PART-II)Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.25mm dia PVC ASTM pipe (sch-80) Ground floor |
| 132 | 32mm dia PVC ASTM pipe (sch-80) roof top |
| 133 | 40mm dia PVC ASTM pipe (sch-80) roof top |
| 134 | 50mm dia PVC ASTM pipe (sch-80) roof top |
| 135 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge20mm dia C-PVC PipesFirst Floor |
| 136 | Second Floor |
| 137 | Third Floor |
| 138 | 25mm dia C-PVC PipesFirst Floor |
| 139 | Second Floor |
| 140 | Third Floor |
| 141 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) |
| 142 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
| 143 | 15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make) |
| 144 | 25mm dia brass full way valve (Shakti make) |
| 145 | 32mm dia brass full way valve (Shakti make) |
| 146 | 40mm dia brass full way valve (Shakti make) |
| 147 | 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) |
| 148 | 15mm CP Extension piece |
| 149 | 125mm CP grating |
| 150 | 15mm size C.P. flange |
| 151 | WALL MIXER WITH PROVISION FOR OVERHEAD Shower (FLR-ABR-5273UPR) |
| 152 | 20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) |
| 153 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge2000 liters capacity PVC water storage tank top of 3rd floor |
| 154 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.First Floor |
| 155 | Second Floor |
| 156 | Third Floor |
| 157 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-chargeFirst Floor |
| 158 | Second Floor |
| 159 | Third Floor |
| 160 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.First Floor |
| 161 | Second Floor |
| 162 | Third Floor |
| 163 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.110mm U-PVC SWR Pipe (Ashirvad/Supreme Make) |
| 164 | 110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make) |
| 165 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 166 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 167 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 168 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 169 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 170 | 110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
| 171 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 172 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.580mm size Orissa pan (Hindware/Parryware/Neycer make) |
| 173 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 174 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-chargeEuropean water closet with 'S' trap plain(Hindware/Parryware/Neycer make) |
| 175 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) |
| 176 | 550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) with 22” x 16” pedestal |
| 177 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink |
| 178 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail |
| 179 | Towel ring |
| 180 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600 x 125mm plate glass shelf with CP guard rails(Jaquar)AKP-CHR-35771P |
| 181 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.Design Large Mirror |
| 182 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeCP soap holder |
| 183 | Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge.15mm CP revolving shower (Jaquar)CON-CHR-209KN |
| 184 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 185 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 186 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\\"-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.Floor TilesFirst Floor |
| 187 | Second Floor |
| 188 | third Floor |
| 189 | Wall TilesFirst Floor |
| 190 | Second Floor |
| 191 | Third Floor |
| 192 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-chargeFirst Floor |
| 193 | Second Floor |
| 194 | Third Floor |
| 195 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge )Kajaria/Somany/Johnson tile30cmx30cmFirst Floor |
| 196 | Second Floor |
| 197 | Third Floor |
| 198 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.First Floor |
| 199 | Second Floor |
| 200 | Third Floor |
| 201 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge )Kajaria/Somany/Johnson tile 60cmx30cmFirst Floor |
| 202 | Second Floor |
| 203 | Third Floor |
| 204 | Granite Tiles First Floor |
| 205 | Second Floor |
| 206 | Third Floor |
| 207 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 208 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 209 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge100mm dia P.V.C. pipe |
| 210 | 150mm dia P.V.C. pipe |
| 211 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-chargeInside size 76cmx76cmx46cm with 18” dia RCC MH cover |
| 212 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification.MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover ) |
| 213 | Supplying all materials, labour, T&P and constructing soakway pit of the size1.07m dia x 2.10m deep soakway pit with precast RCC rings joined loose, gravel backing in the rear of well steining, precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 214 | 4 nos 20 Users Septic tankEarth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 215 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 216 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge |
| 217 | Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 40mm size crusher broken hard black granite metal including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 218 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 219 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 220 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 221 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-chargeRCC floor, roof slab chhaja up to 4.430 m height |
| 222 | Supplying all materials.labour.T&P and providing brick work in foundation and plinth with KB bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar ( 1:3 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. |
| 223 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 224 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 225 | Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. |
| 226 | Supplying all materials, labour T&P for providing fitting & fixing 150mm x 150mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. |
| 227 | 2 nos 14,000 ltr capacity R.C.C. Under ground sump of in side size (2.80m x 2.80m x 2.0m)Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 228 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 229 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 230 | Supplying all materials labour T&P filling sand in foundation and plinth with well watered and rammed etc. all complate. As per direction of ELC. |
| 231 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 232 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 233 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 234 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-chargeRCC floor, roof slab chhaja up to 4.430 m height |
| 235 | Supplying all materials,labour,T&P and providing 6mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 236 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 237 | Construction of 2 no production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessoriesLabour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore00 mtr to 30mtr |
| 238 | 30 mtr to 45mtr |
| 239 | Drilling of 150mm dia bore46 mtr to above |
| 240 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.Lowering of 200mm dia P.V.C casing pipes00 mtr to 30 mtrs |
| 241 | 30 mtr to 45mtr |
| 242 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.200mm dia PVC (sch-80) pipe |
| 243 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 244 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in chargeBy DTH Rig |
| 245 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:Rocky terrain with boulder formation for 300m depth |
| 246 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)2 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm |
| 247 | DOL Control panel |
| 248 | 40mm dia steel short piece |
| 249 | Well cap |
| 250 | 50mm size CI bracket |
| 251 | 2.50sqmm flat cable |
| 252 | 20mm dia rigid UPVC pipes |
| 253 | Steel rope with cover |
| 254 | Labour charges for lowering including transportation |
| 255 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge32mm HDPE pipes (Finolex/Supreme make) |
| 256 | E.I. WORKS (PART-III)Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZH PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI or equievalant reputed make A catagory ISI marked as approved with 20 mm dia PVC flexible non metallic conduit FRLS type ISI marked Make-AKG/Anchor/Havells or equievalant reputed make A catagory ISI marked as approved 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, and ceiling rose ISI marked Make- Anchor/Havells/Eq of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)or equievalant reputed make & model A catagory ISI marked as approved of suitable size, modular box with 1.5 sq. Mm FRLSH PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete suitable for office standard. All the switches & sockets should be warrantied for a replacement period of 10 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group A |
| 257 | Group B |
| 258 | Group C |
| 259 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, complete suitable for office standard.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 10 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 260 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)or equievalant reputed make A catagory ISI marked as approved, (For equipement power)All the switches & sockets should be warrantied for a replacement period of 10 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.( 12 no. for Kitchen and 12 for washing machine and 12 for geyser) |
| 261 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire -Finolex/L&T/Anchor/Havells/V-Guard/Great White/Mescab/HPL2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty flexible conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 262 | 1 nos single core 1.5 sq. mm copper wire for iNVERTER WIRING IN EXISTING CONDUIT (1 X 1.5) |
| 263 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
| 264 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit .(PDB to PSB/ GAYSER POINT/AC POINT/ROOM LIGHT CONTROL TO CORRIDOOR POINT/DG PANEL ESSENTIAL LOAD) (2X4+1X1.5) |
| 265 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty flexible conduit .(LFDB TO LBDB) (2X6+1X2.5) |
| 266 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /ABB(Equivalant model)/L&T(Equivalent model) or equievalant reputed make & model A catagory ISI marked as approved. as per direction of Engg.-in-Charge.Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (OUTDOOR LIGHT-1, UPS -4 ) |
| 267 | Supply and fixing of 4 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (OUTDOOR LIGHT-1, UPS -4 ) |
| 268 | Supplying and fixing 6-32 amps rating, 240 volts, C series, Single Pole MCB of Make-L&T/Legrand/Schneider/Siemens/ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 5 years Warranty on MCB is 5 years. |
| 269 | Supplying and fixing 6-32 amps rating, 240 volts, C series, Double poles MCB of Make-L&T/Legrand/Schneider/Siemens/ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 5 years Warranty on MCB is 5 years. |
| 270 | Supplying and fixing 40-63 amps rating, 240 volts, C series, Double poles MCB of Make-L&T/Legrand/Schneider/Siemens/ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 5 years Warranty on MCB is 5 years. |
| 271 | SITC of energy efficient LED tube light fittings having power rating not more than 20 watt having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Havells/Crompton/Jaquar/Panasonic/Bajaj/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved) |
| 272 | Supplying, installation, testing and commssioning of 1400 mm sweep white/milky colour ceiling fan Make- Havells/almonard/Crompton/Usha or equievalant reputed make & model A catagory as approved ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.(With fan Regulator) as required as per direction of Engg.-in-Charge.Replacement Warranty will be 2 years. |
| 273 | Supply and fixing modular type regulator on the existing switch box/cover . Equievalant higher model of Schneider/Hager/Siemens/Anchor/Panasonic make or equievalant reputed make & model A catagory ISI marked as approved as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 5 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 274 | Supplying, installation, of exhaust fan of 150 mm plastic exhaust fan (Make- Havells/almonard/Crompton/Usha or equievalant reputed make & model A catagory ISI marked as approved ) in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 275 | Supplying,fixing of 2x6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)or equievalant reputed make & model A catagory ISI marked as approved, (For equipement power)complete suitable for office standard.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 10 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 276 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells/Panasonic or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 5 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 277 | S/F of 12W LED Bulb |
| 278 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. Equievalant higher model of Schneider/Hager/Siemens/Anchor/Panasonic make or equievalant reputed make & model A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 5 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 279 | S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 280 | Supply & fixing of AC starter with 15 A modular socket |
| 281 | Supply and errection of 9 mtr PSC Pole |
| 282 | PANELS/F of DP Main Switch (Make - Cona/ Anchor)63A 240V DP M/S |
| 283 | Supply and fixing of following Almunium Service wire including G.I. Stay wire ISI marked.(Make- Polycab/ v-Guard/ Mahavir/ Or equivalent)10 Sq.mm Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy