| 1 | Civil Works |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated 2.8.1 All kinds of soil. |
| 3 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to 4.1.6:-1:3:6 (1 Cement 3 coarse sand (zone-III) derived from natural sources 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth 5.22.4:- Hot rolled deformed bars |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth 5.22.1:- Mild steel and Medium Tensile steel bars |
| 7 | Centering and shuttering including strutting. propping etc and removal of form for 5.9.1:- Foundations, footings, bases of columns. etc. for mass concrete |
| 8 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 9 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and 5.1.2-1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, 5.2.2-1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 |
| 12 | Brick work with common burnt clay FPS (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement 4 coarse sand |
| 13 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 14 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25%: 4 graded stone aggregate 12.5mm nominal size (Recycled Concrete |
| 15 | Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement: 3 coarse sand) in superstructure above plinth level and upto floor five level. |
| 16 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement 4 coarse sand) |
| 17 | Providing wood work in frames of doors. windows, clerestory windows and other frames. wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash9.1.3 Kiln seasoned and chemically treated hollock wood |
| 18 | Steel work in built up tubular (round, square or rectangular hollow tubes etc) trusses etc.. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes |
| 19 | Providing corrugated G.S sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 20 | Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 sq. decimeter 12.3.2 0.80 mm thick |
| 21 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with 9.20 1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 22 | Float glass panes 9.7.7.1 4 mm thick glass pane (weight not less than 10kg/sqm) |
| 23 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1.2.4 (1 cement: 2 coarse sand 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @2 litre per 50 kg of cement or as per manufacturer's |
| 24 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 25 | Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/som (both side inclusive) as per IS: 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm cic, one flange fixed to the 12.59.18 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process |
| 26 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cerment 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thick |
| 27 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:13.41.1:- New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 28 | Finishing walls with Acrylic Smooth exterior paint of required shade:13.46.1 New work (Two or more coat applied @ 1.67 Itr/10 sqm over and including priming coat of exterior primer applied @2 20 kg/10 sqm) |
| 29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 30 | Applying priming coat 13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 31 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications:13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 Itr/10 sqm over an under coat of primer applied 20.75 ltr/10 sqm of approved brand |
| 32 | 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 Itr/ 10 sqm over an under coat of primer applied @ 0.80 Itr/ 10 sqm of approved brand and manufacture |
| 33 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:13.43.1 Water thinnable cement primer |
| 34 | Finishing walls with water proofing cement paint of required shade:13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 35 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete9.48.1 Fixed to steel windows by welding |
| 36 | 96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete 9.96.1 300x16 mm |
| 37 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 9.97.3 200x10 mm |
| 38 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 9.100.1 125 mm |
| 39 | Electrical Works |
| 40 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 41 | Group CWiring for circult/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2x2.5 sq. mm+1X2.5 sq. mm earth wire |
| 42 | Wiring for circult/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2x4 sq. mm+1X 4 sq. mm earth wire |
| 43 | Wiring for circult/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2x6 sq. mm+1X 6 sq. mm earth wire |
| 44 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 45 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 46 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 47 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 48 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 49 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 50 | Earthing with G.l. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 51 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with Gi thimble etc. as required. |
| 52 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining |
| 53 | Supplying, fitting of 9 Watt LED Lamp in the existing batten holder/angle holder/bracket/pendent holder etc as directed by the department. |
| 54 | Supplying with fitting and fixing of LED tubelight complete with all accessories such as ballast, starter,etc. directly on wall/ceiling including connection cable as approved by the deptt with 1.5 sqmm PVC insulated SC Copper conductor as required and as directed by the department. |
| 55 | Supplying, installation, testing and commissioning of the following outdoor Streetlight LED luminaries complete with all accessories as required complete with 2.5sqmm PVC Insulated SC copper conductor as required and directed by the departement. 40Watt, make: Havells Including Single Arm Bracket Please Enable Macros to View BoQ information |