| 1 | Excavation in trenches not exceeding 1.5 m in depth and 1.5 m in width and not exceeding 10 sqm on plan getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil complete all as specified and directed. |
| 3 | Removing excavated material (soil) not exceeding 50 m and deposited where directed at a level not exceeding 1.5 m above the strating point complete all as specified and as directed. |
| 4 | M&L for plain cement concrete 1:4:8 type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 5 | M&L for steel form work to side of column and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels,slab and simillar work complete all as specified and directed. |
| 6 | M&L for steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 7 | M&L for reinforced cement concrete 1:1.5:3 type B-1 (Nominal Mix) using 20 mm graded crushed aggregate as in foundations, including rafts,footings, foundation beams;plinth beams; bases forcolumns, etc.; basement slabs,under-reamed piles and massconcrete complete all as specified and as directed. |
| 8 | M&L for reinforced cement concrete 1:1.5:3 type B-1(Nominal Mix) using 20 mm graded aggregate as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 9 | M&L for reinforced cement concrete 1:1.5:3 type B-1 (Nominal Mix) using 20 mm graded crushed aggregate as in Beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified and as directed. |
| 10 | M&L for reinforced cement concrete 1:1.5:3 type B-1 (Nominal Mix)using 20 mm graded crushed aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 11 | S&F mild steel TMT bars 10 mm dia and over , cut to length, bent to shape requred, including crancing bending and binding with mild steel (anneal) wire not less than 0.90mm dia. Fe 550 D grade TMT bar complete all as specified and as directed. |
| 12 | M & L for mild steel bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 13 | Material & labour for brick work with sub class B old size burnt bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specifie and as directed. |
| 14 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth withot using extra cement complete all as specifie and as directed. |
| 15 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces with cement mortar 1:4 mixed with WPC finished even and smooth without using extra cement complete all as specifed and directed. Note : WPC will be measured & paid separately. |
| 16 | M&L rendeing 5 mm thick on ceiling surfaces in cement mortar 1:3 finished even and smooth without using extra cement including necessary scaffolding, formwork, safety precautions, complete all as specified & as directed. |
| 17 | Supply only Liquid water proofing compound of approved quality complete all as specified & as directed. |
| 18 | M&L for preparation of newly plastered surfaces and applying two coat of cement based paint over a coat of primer complete all as specified and as directed. |
| 19 | M&L for preparation of newly plastered surfaces and apply three coat of white wash on wall surface complete all as specified and as directed |
| 20 | M&L for preparation of newly plastered surfaces and apply three coat of white wash on ceiling surface complete all as specified and as directed |
| 21 | M&L for Non skid coloured ceramic tiles 7 to 8 mm thick( square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, as in floors laid on 15 mm thick cement screed bed in cement mortar (1:4), set and jointed in tile adhessive (type-II), (5-10mm thick) and pointed in white/coloured cement to match the shade of tiles complete all as specified and as directed. |
| 22 | M&L Non skid coloured ceramic tiles 7 to 8 mm thick( square/rectangular)area of each tile exceeding 0.18 sqm but n exc 0.36 sqm, as in skirting on 15 mm thick cement screed bed in cement mortar (1:4), set and jointed in tile adhessive (type-II), (5-10mm thick) and pointed in white/coloured cement to match the shade of tiles complete all as specified and as directed |
| 23 | M&L for Two coats of Single component non-UV resistant based polyurethane to be applied over the primed surface in an interval of 4-6 hrs. The topcoats should be applied with brush/ roller. No dilution is required for these two coats. A non-woven geotextile sheet of 150 GSM to be sandwiched between the layers. The deposition of PU should be 1.8 kg per Sq.mt providing avg thickness of 1.2 mm. The tensile strength of the product should be minimum 1.8 N/mm2. The elongation of the free film should be min 650% as per ASTM D412, Shore A Hardness should be min 45 as per ASTM D-2240, Crack Bridging @-9degree C min 1.5 as per ASTM C 836 & Solid Content should not be less than 90%. Moreover, the material should confirm to ASTM C-836, ASTM C-898 and over inculding SRI Coating, The topcoats should be applied with brush/roller/Spray. The deposition should be min 1.2 kg per Sq.mt. The Crack Bridging of the product should be minimum 1.5 mm & SRI value should be greater than 106. The priming coat should be self- priming with a dilution of 40% with potable water. This layer includes 1 priming coat+ 2 undiluted Topcoats complete all as specified and directed. |
| 24 | S&F fabricated aluminum window/ventilator with frames (Powder coated) including jointing cleats for fixing builder's hardware & provision for glasspanes/wire mesh including necessary fittings/fixture /aluminum snap beads etc,complete all as specified and as directed by Engr-in-Charge.Note:- (a) Glazing/Wire mesh shall be measured under respective item seperatly (b) Items shall be paid as per weight of aluminium sections (c) The rates quoted shall be inclusive of neoprene beading glazing clips, screws, etc as required whichshall not be measured for arriving the weight (d) The rate shall be inclusive of locking arrangement including fixing of aluminium hinges &Aluminium tower bolt in each shutter complete all as specified and as directed. |
| 25 | S&F in repair 4.0 mm thick plain/frosted sheet glass ordinary quality and glazing with Al glazing clips& EPDM beading in square/rectangular any size in each pane complete all as specified and as directed. |
| 26 | S & F Pressed steel frames of size 125 mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed. |
| 27 | S&F 35 mm thick Factory made 2nd class hardwood plain,framed paneled shutters(any numbe of panels) with lock rail and panel of 9mm BWP commercial ply with commercial veneering on both faces size of rail and stile as per IS-1003(part) Kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 28 | M & L for preparation of new wooden surfaces of any description not otherwise described over 10 cms width or girth and apply two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. |
| 29 | S&F stainless steel AISI 304 grade barrel tower bolt 200mm long, extruded section,etc. complete all as specified and as directed. |
| 30 | S&F stainless steel AISI 304 grade handle of size 200mm long,etc. complete all as specified and as directed. |
| 31 | S&F Stainless steel of AE SI 304 Grade, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 32 | S & F floor door stopper (double leg) of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor; overall length of cover plate 60mm complete all as specified and as directed. |
| 33 | M&L for 18 mm thick wood plastic composites (WPC) board, 100% solid with density not less than 650 Kg per cubic meter , one side wood grain finished laminated for exposed/external surface , fixed with screws fitted under or above the kitchen cooking platform and/or other platform including all necessary fittings and fixtures like nickle plated clip hinges, knobs, channels etc complete all as specified and directed.Note : (a) Pattern & design of WPC board to be decided by GE.(b) Items like cupboard knobs, stainless steel channel, CP plate clip hinges to be paid in extra. |
| 34 | S & F Continuous (piano) hinges width of flap 30 mm, mild steel, bright finish or electrogalvanised fixed to steel chowkhat with welding or with screws complete all as specified and as directed. |
| 35 | S&F 15mm mild steel, chromium plated rod with fixing brackets, fixed in cupboards for hanging cloth of adequate strength complete all as specified and as directed. |
| 36 | S&F stainless steel AISI 304 grade handle of size 75 mm long,etc. complete all as specified and as directed. |
| 37 | S&F Magnetic catch for wooden cupbord with complete closer macanigum claps and clips fix with stainless steel screw.complete all as specified and as directed. |
| 38 | Surface dressing not exceeding 15 cm deep in any type of soil complete all as specified and as directed. |
| 39 | M&L for 100 mm thick plain cement concrete (1:4:8) Type D-2, (using 40 mm graded crushed stone aggregate) , as in sub-base and similar works complete all as specified and as directed. |
| 40 | M&L for cement concrete type B-1, 1:2:4 using 20 mm graded crushed stone aggregate as in coping on edges etc including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified and directed. |
| 41 | M&L for machine pressed precast concrete interlocking paver block any colour , any shape and size confirming to IS 15658-2006 of 60 mm thick, M-35 grade, laid over and including 50 mm sand cushioning complete all as specified and as directed. |
| 42 | S&F Precast factory made M-30 concrete saucer drain of 600 mm long each piece, 300 mm wide and 100 mm thick set in cement mortar1:4 including necessary earthwork/demolition of existing PCC drain etc complete all as specified and as directed. |
| 43 | Excavating in post holes (or similar holes) each n.exc 0.50 cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil n.exc 50m and making good the surface in any type of soil complete all as specified and directed. |
| 44 | M & L for Cement concrete 1:3:6 type C2 (using 40mm graded aggregate) as in foundations, filling and mass concrete all as specified and directed. |
| 45 | M & L for Cutting holes in brick walls in built in cement mortar or cement lime mortar exc half brick but not exc one brick complete alll as specified and as directed. |
| 46 | Cutting chases, pinning in , making good to facings where required and pointing in cement mortar 1:3 to ends or edges or landings, steps, cills, sunshades, shelves, lintel,etc and cutting in chases for concealed conduit wiring, etc and making good, cutting not exceeding 10 cm girth complete alll as specified and as directed. |
| 47 | M&L for steel work in tubuler trusses including special shaped washer, cleats etc complete using ERW or induction butt welded tubes confirming to IS: 1161-1979 grade st - 240 complete all as specified and as directed. |
| 48 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide , zinc chrome primer including preparation of new steel surfaces of any description, not itherwise described, over 10 cm width or girth, complete all as specified and directed. |
| 49 | S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete alll as specified and as directed. |
| 50 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285,fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete alll as specified and as directed. |
| 51 | Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors,windows& ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws all complete alll as specified and as directed. |
| 52 | S & F ACP sheet 4 mm thick of any colour, fixed with aluminium beading in aluminium window/ventilation etc all as specified and directed. |
| 53 | S & F 5.5 mm thick selected quality plain/frosted glass, in square exceeding 0.5 Sqm in each pane, fixed with aluminium beading in aluminium window/ventilation etc all as specified. |
| 54 | S&F Powder coated anodised aluminium snap grid frame size 605 x 605 mm and 2-3 mm thick for false ceiling, hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm longand expansion hold fasteners 12.5mm dia. 40mm long and including acoustic gypsum perforated tiles 4 mm thick of size 600x600 mm fixed in ceiling or laid/ inserted to Aluminium snap grid complete all as specified and as directed. |
| 55 | S&F 4 mm thick Fibre glass reinforced translucent plain sheeting of any colour and pattern fixed with coach screw and washer in wall , complete as specifed and as directed. |
| 56 | M&L for framed work as in doors, gates of angle fencing post of fe -410 gde E 250 qureed section with gussed plates complete drilled or welded to be prepared for hanging or sliding with and including either hooks and hinges complete all as specified and directed. |
| 57 | Mild steel work as in angle iron posts or struts for fencing conforming to Fe-290 Gde E-165 as directed, including cutting top to ashape as directed, drilling holes, notching for wire etc including cutting and twisting necessary drilling, bolting and revieting or welding etc and similar works complete all as specified and directed. |
| 58 | M & L for MS nuts and bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be provided with one washer and nut complete all as specified and directed. |
| 59 | M&L for concealed point wiring complete with stranded copper conductor 1.5 Sqmm nominal area PVC insulated single core unsheathed FRLS 1100 volts grade electrical cable drawn existing concealed PVC conduit in wall and ceiling and including replacement of unserviceable pressed steel terminal boxes with Modular steel terminal boxes of min thickness 1.2 mm with 120 GSM Zinc coating including white cover modular plate with frame suitable for modular switches, modular sockets, modular fan regulators etc of required size complete including 1.5 sqmm copper cable Single core PVC insulated unsheathed earth continuity wire to common earth and connected to earth dolly complete all as specified and directed.Note (a): The rates are inclusive of providing point wiring on casing caping if there is blockage/damage in existing conduit on ceiling.(b) :The rates are inclusive of cutting / chasing and making good disturbed surface with CM 1:3. |
| 60 | All as per item No 59.00 here-in-before but One socket outlet 5 Amps on same board. |
| 61 | All as per item No 59.00 here-in-before but One socket outlet 5 Amps on independent board. |
| 62 | All as per item No 59.00 here-in-before but One socket outlet 15 Amps on independent board and through new concealed conduit complete with 2.5 sqmm size. |
| 63 | S & F Switch Modular type switch, 6 A 1- way 1 Module switch with finger proof terminal complete all as specified and directed. |
| 64 | S & F modular type 2/3 pin combined shuttered type 6A socket 2 Module complete all as specified and directed. |
| 65 | S & F Switch Modular type switch, 16 A 1- way 1 module switch with finger proof terminal complete all as specified and directed. |
| 66 | S & F modular type 2/3 pin combined shuttered type 16 A socket 2 Module,complete all as specified and directed. |
| 67 | S & F AC modular box with MCB 20 Amps complete all as specified and directed. |
| 68 | S & F ceiling rose 3 terminal complete all as specified and directed. |
| 69 | S&F surface mounting LED Integrated Aluminum Batten luminaries Polycarbonate co-extrusion tube for Not less than 20 Watt LED light housing. Fixture should have minimum system lumen of 2000lm & minimum efficiency at system level >=120 lumens/Watt, life of fixture 50K Hrs, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95 THD<10% @ 240V AC An operating voltage Range of 140-270V including all connection up to ceiling rose complete all as specified and directed. |
| 70 | S & F 60 Watt street light high efficiency long life LED module with LENS type LED package mounted on MCPCB, Fixture should have minimum efficiency at system level >=120 lumens/Watt, integral SMPS based constant current electronic LED driver with THD<10% surge voltage protection of > 5.0 KV, CRI>80, PF>0.95,CCT 4000-6500K and other safety tests as per IS:15885( part-2/sec-13),IP 66 protection high efficiency polycarbonate cover with integrated lens housed in pressure die cast aluminim alloy heat sink for effective thermal management strudiness excellent corrosion resistance separate optical and control gear compartment & Top opening for easy maintanance suitable for side entry wall mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible copper cunductor cable of appropriate size and 1.5m long bracket having 40mm diameter light grade GI pipe including GI clamp nuts bolts & washers with two coats of synthetic enemal paint over a coat of oxide primer complete all as specified and directed. |
| 71 | Supply, Installation, testing and commissioning of 1200mm sweep BEE 5 star rated, Ceiling fan with remote control, Brush Less Direct Current (BLDC) Motor, Class of insulation : B, 3 Nos Blade, 30 cm long down road, 2 Nos canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, Air delivery not less than 220 CMM, 350 RPM (tolerance as per IS:374-2019), THD less than 10%, and all remaining accessories including safety pin, nuts bolts, washers, temperature rise =75 degree C (maximum), insulation resistance more than 2 mega Ohm, suitable for 230V, 50 Hz, single phase AC supply complete including taking down and keeping in safe coustody and depositing it to MES store yard complete all as specified and directed. |
| 72 | Supply and fix in replacement of SPN 8 Way double door mettalic DB with rubber gasket conforming to IEC 61439-3 suitable for flush / surface mounting having 100 A copper busbar fully shrouded neutral bar earth bar wire set & cable ties for cable management pre fiited sheet etc. Having IK 09 & IP 43 protection complete including taking down of old DB all as specified in IS 732:2019 complete all as specified and directed. |
| 73 | M&L in replacement MCB SPN 'C' curve 40 Amps 240 Volts , 10 KA complete all as specified and directed. |
| 74 | M&L in replacement MCB SP 'C' curve 06 to 32 Amps 240 Volts 10 KA complete all as specified and directed. |
| 75 | S &F in replacement for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing complete all as specified and directed. |
| 76 | M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 4.0 Sqmm, 450/1100 Volts grade on & including PVC Conduit 25 mm medium grade complete with conduit accessories and copper cable 4.0 sqmm continuous earth wire complete all as specified and directed (Two runs of cable with 01 earth wire shall be measured as one length) |
| 77 | Supply and fix in repair of GI pipe's bracket suitable for fixing of bldg security LED light fitting of 45 Watts including grouting and fixing the same on wall for installation of light fitting with necessary clamps, nut, bolts & washer and painting by synthetic enameled good quality paint in white/grey colour over one coat of red oxide primer until unless smoothness of bracket complete all as specified and as directed.Note :- GI pipe should be 25 mm bore with medium grade and the same to be moulded in 45 degree angle at the 1m height to fix the building security light fitting. |
| 78 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 M in depth and getting out in hard /dense soil for taking up or laying of cable all as specified and directed. |
| 79 | Removal of surplus soil not exceed to a distance of 50 M where directed at a level not exc 1.5M above the starting point. |
| 80 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceding Cum 25cm complete al as specified and directed. |
| 81 | Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as secified and directed. Note : Punned thickness only measured and paid. |
| 82 | M & L for brick well brunt locally available sub class'B' laid over sand cushioning to cable in trenches keping width of brick parallel to the length of cable complete all as specified and directed. |
| 83 | Supply and laying in repair of XLPE insulated,sheathed,armoured,heavy duty LT 1100 volts grade cable 25 Sqmm 3.5 core with aluminium conductor laid in trenches/pipes, fixed to poles/walls with suitable saddle aluminium lugs, gland if required and jointed complete all as directed. |
| 84 | Supply and laying GI tube light grade size of 40 mm dia laid through trenches/under road floor for cable protection complete all as specified and directed. Please Enable Macros to View BoQ information |
| 85 | Supply and laying GI tube light grade size of 40 mm dia laid through trenches/under road floor for cable protection complete all as specified and directed. Please Enable Macros to View BoQ information |