| 1 | Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by EngineerRubble stone masonry in cement mortar. |
| 2 | Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with alllifts and lead of 50 metres as directed by Engineer . Lime Concrete, cement concrete grade M-10 (1:5:10) and below |
| 3 | Cement Concrete Grade M-15 and above and PCC blocks |
| 4 | Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitablesite as per direction of Engineer for following depths, below naturalground / Road top level.In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc.Depth upto 1.5 m.In ordinary rock.Depth upto 1.5 m |
| 5 | Carriage of Materials by mechanical transportincluding loading, unloading and stacking ::Earth5 Km |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 7 | Random rubble masonry with hard stone in foundation and plinth :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 8 | Extra for random rubble masonry with hard stone in superstructure above plinth level and upto two stories. |
| 9 | Centring and shuttering with plywood or steel sheet upto two stories ( each story of height upto 3.5 metre from floor level) including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete. : |
| 10 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 11 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 12 | Suspended floors, roofs, landings, balconies and access platform. |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar M-20 Grade Concrete (1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) -As per design mix) |
| 14 | Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Cold twisted bars |
| 15 | Plastering with cement mortar (1:3) on Brick/stone work in substructure/ super structure at any height complete as per clause 1312 of MoRT&H specification including all material, labour, scaffolding etc. 20 mm plaster on stone work |
| 16 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over andincluding base coat of water proofing cement paint applied @ 2.20kg/ 10 sqm). |
| 17 | Providing and fixing fine dressed sand stone/approved stone Traditional work as per existing matching geometrical design including moulding work with fine finishing, fixing with thambli by proper adhesive and white cement with pigment including making groove etc. complete in all respect. |
| 18 | Providing and fixing stone jali 40mm thick throughout in cementmortar 1:3 (1 cement : 3 coarse sand) including pointing in whitecement mortar 1:2 (1 white cement : 2 stone dust) with an admixtureof pigment, matching the stone shade, jali slab without any chamfersetc.Red sand stone |
| 19 | Stone work, plain in copings, cornices, string courses and plinthcourses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6coarse sand) including pointing with white cement mortar 1:2 (1white cement : 2 stone dust) with an admixture of pigment matchingthe stone shade.Red sand stone |
| 20 | Making Kangura on top of the wall as per Jaipur traditional practicewith tile brick bats/stones in grinded Lime Surkhi mortar 1:2thickness of kangoora 15cm & height 45cm, finishing with limeSurkhi mortar 1:2 complete in all respect up to 10.00 meter fromground level including all scaffolding, lead & lift. |
| 21 | Providing and fixing fine dressed sand stone \\" Gardana of sandStone \\" on top of the wall at varandha as per existing matching ,fixing in grinded lime surkhi mortar 1:2 including pointing in creamand stone powder 1:1 with an admixture of pigment to match theshade of stone complete in all respect. above 100 mm to 150 mmthick plain with fine dressing. |
| 22 | Providing and fixing red sand stone brackets 55x22.5x45cm sunkand moulded including providing and fixing with 4 Nos. gun metalcramp 25x6mm 30 cm long and dowel bars 7.5 cm long 6 mm diaas per design. |
| 23 | 30mm red sand stone sun-shade (chisel-dressed) supported on redsand stone brackets, fixed in walls with cement mortar 1:4 (1 cement: 4 coarse sand) including finishing complete |
| 24 | Providing and fixing horizontal chajja of stone 40 mm thick and upto80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand)including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade:Red sand stone |
| 25 | Supplying and fixing machine cut fine dressed Red/Pink sand stonedasa or coping, with full moulding if required laid on cement mortar1:4 including pointing with admixture of pigment matching with thestone shade. 50 mm thick |
| 26 | Providing and fixing sloping chajja of stone 40 mm thick and upto 80 cm wide beyond the wall as measured along the slope in cementmortar 1:4 (1 cement : 4 coarse sand) with 12mm diameteranchoring steel bar 45 cm long fixed in each stone and supported onand including with bricks cove of class designation 75 in cementmortar 1:4 (1 cement : 4 coarse sand) including pointing in cementmortar 1:2 (1 white cement : 2 stone dust) with an admixture ofpigment matching the stone shade:Red sand stone:With bricks |
| 27 | Filling with locally available river sand at all levels including wateringramming consolidating and dressing complete including cost ofsand. |
| 28 | Random rubble dry stone Kharanja (soling) under floor |
| 29 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded 20mm nominal size stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06 mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e. 125 gms per 50 kg Cement up to 900 gms per cum of Concrete/ mortar 75mm thick |
| 30 | Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) or slab in wall, steps, pillars, counters, jambs, shelves, sills etc laid over 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand), jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Rajnagar 1st quality/Ageria with light spots. Above 3601 Cm2 Slabs |
| 31 | Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. |
| 32 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereverrequired including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately) :For fixed portion.Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) |
| 33 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sideswith required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing /panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron)Powder coated aluminium (minimum thickness of powder coating 50micron) |
| 34 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basic item)With float glass panes of 4.0 mm thickness |
| 35 | Wrought iron and mild steel welded work) (using angles, square bars, tees and channel grills, grating frames, gates and tree guards of any size and design etc. including cost of screens and welding rods or bolts and nuts complete fixed in position but without the cost of excavation and concrete for fixing which will be paid separately. |
| 36 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 37 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work Please Enable Macros to View BoQ information |