| 1 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. complete all as specified and directed by Engr-in-charge. |
| 2 | S & F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified all as specified and directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof , ridge / valley gutter, fixed with self tapping screws as specified |
| 4 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets and as specified and directed. |
| 5 | S&F hangers 6mm dia G.I. (upto 1200mm length ) adjusting level, size of grid 605mm X605mm, fixed to roof slabs mean of ceilling cleats made out of GI flat 40X3mm size 60 mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 6 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and includingceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to ,size of grid 605mm X605mmcomplete all as specified. |
| 7 | S&F Non asbestos fiber cement designer building board 6mm thick ,fixed to aluminium or MS galvanised snap grid frame work with screw in ceiling complete all as specified and directed. |
| 8 | Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for. |
| 9 | M&L for 75 mm thick PCC 1:3:6 type C2 in plinth protection finishing even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 10 | M &L for 40 mm thick PCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) as in sub base in floors complete all as specified and directed by Engr-in-charge |
| 11 | S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match shade of the tiles complete all as specified & directed.Notes : Shade of the tile including colour, design and pattern shall be approved by AGE |
| 12 | S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match shade of the tiles and including 10mm thick rendering as in backing coat in CM 1:6,complete all as specified & directed.Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 13 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises |
| 14 | S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match shade of the tiles including 15mm thick screed bed in CM 1:6, complete all as specified and directed. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 15 | M&L coloured Glazed ceramic tiles in vertical surfaces 350 x 250 x7 mm/ 450 x 350 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles including 10mm thick rendering in CM 1:4 as in backing coat complete all as specified and directed.Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 16 | Taking down cement plaster any description from roof slab, stone wall, brick wall parapets including raking out joints hacking for key and scrubbing down with water etc(for roof treatment) complete all as specified. |
| 17 | M&L rendering 15mm thick on Brick masonary in internal surfaces in CM 1:4 finished even and smooth with sagol finish complete all as specified and directed. |
| 18 | Preparing new plastered surfaces and applying Two coats of cement base paint on surfaces of walls over a coat of alkali resistance primer complete all as specified and directed by engr in charge. |
| 19 | M&L complete removal of existing treatment applying two coat of cement base paint over a coat of primer on walls, etc all as specified and directed. |
| 20 | M&L complete removal of existing treatment applying two coat of Oil Bond distermper white or tinned over a coat of primer on walls, etc all as specified and directed. |
| 21 | Material & labour for two coats of synthetic enamelled paint on old steel surfaces exc 10cm width or girth including preparation of surfaces.complete all as specified and directed by Engr In Charge. |
| 22 | S & F in repair aluminium extruded section body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 23 | Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or removal to store all as specified and as directed. |
| 24 | Taking up or down 20m bore steel tubing and connections including cleaning for refixing or removal to store all as specified and as directed. |
| 25 | S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 15mm all as specified and as directed. |
| 26 | S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 20 mm all as specified and as directed. |
| 27 | S & F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device vitrious Chaina pedestal pattern WC incl PVC seat cover and flush pipe etc complete all as specified and directed. |
| 28 | S & F in repairs PVC valveless, syphonic action type, flushing cistern of 10 ltrs capacity, high or low level, white, with inlet, ball valve, float and handle including brackets, and connections to flush pipes of polyethylene of low or high density or PVC. 32 mm dia, for low levelcistern complete all as specified and directed. |
| 29 | S&F in repairs for Wash basins,pedestal pattern Vitreous China (flat back or angle back type) size 580X450mm, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe , complete all as specified and as directed. |
| 30 | S&F in repairs mirror glass of size 0.60X0.450m bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with cromium plated brass screw and cup washer etc complete all as specified and as directed. |
| 31 | S&F in repair brass CP Stop cock/ Angle cock 15mm fancy type choromium platedetc, complete all as specified and as directed. |
| 32 | S&Fin repairs pillar taps cast copper alloy capstan heads, chromium plated, screwed down high pressure with or without lettered HOT or COLD with long screwed shank and fly nuts screwed for iron pipe and fixed bore of pipe 15mm complete all as specified and direrected. |
| 33 | S&F in repairs bib taps cast copper alloy , choromium plated ,with crutch or butter fly handle screwed down screwed for iron pipe etc complete 15mm dia complete all as specified and as directed. |
| 34 | S&F in repairs PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 35 | S&F in repair towel rail 600 mm long of PTMT fixed with and including chromium plated brass screw and wooden/plastic cleats of weight minimum 190grm complete all as specified and as directed. |
| 36 | S & F in repairs Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long all as specified and directed. |
| 37 | S&F in repair 75mm bore PVC (SWR) pipe single socketed in any length with rubber ring joint fixed to wall complete all as specified and directed |
| 38 | S&F in repair 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laidin trenches or in floors complete all as specified and directed |
| 39 | S&F of PVC bends of any radius 110 mm dia bore complete all as specified and directed . |
| 40 | S&F of PVC bends of any radius 75 mm dia bore complete all as specified and directed . |
| 41 | M&L 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 42 | S & F in repairs for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 43 | S & F in repair chromium plated shower rose 125mm size with or without swivel joint any size incl fixing to steel pipe or union complete all as specified and directed. |
| 44 | S&F For 1000 ltr. Capacity rotational moulded polyethylene water storage tanks cylindrical vertical with closed top) hoisted and fixed in position including dismanteling old tanks and removing to store and including all fittings complete all as specified in SSR Part I complete all as specified and directed. |
| 45 | M&L 20 mm bore dia ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 46 | S&F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by engr in charge. |
| 47 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 48 | Supply and fix steel work in tubular trusses/rafetr/purlin including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 complete all as specified and as directed. |
| 49 | Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 50 | Demolition of RCC Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by Engineer-In-Charge. |
| 51 | M & L for Reinforced Cement Concrete Nominal Mix 1:2:4 Type A 1(using 20 mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and inshelves and the like complete all as specified and as directed by Engineer-In-Charge. |
| 52 | Use and waste for flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed by Engineer-In-Charge. |
| 53 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 54 | M&L for black granite 18 to 20 mm thick (of any type) work (table rubbed and polished) in steps, jombs, pillars, window-cill, cooking plateform and like in cement mortar (1:4) and with white cement (1:2) using pointing marble dust with admixture of pigment to match, including Circular cutting or notching and waste of any thickness and size of tiles moulding of granite including 20mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 55 | S&F plain sheet glass of 3 mm thick in Squares not exceeding 0.50 Sqm in each pane with oil putty and clips complete all as directed by Engineer-in-Charge. |
| 56 | Hacking out old broken glass (any thickness, size quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads complete all as specified & directed. |
| 57 | Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 sqm each but with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engr-in-charge. |
| 58 | S&F pressed steel frames 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,complete all as specified and directed by engr in charge. |
| 59 | M&L Plain Cement Concrete 1:3:6 type C1 filling of pressed steel frame and hold fast block etc. complete all as specified and directed by engr in charge. |
| 60 | Supply and fix 35 mm thick 2nd class hard wood factory made plain framed panelled door shutters, (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneered on both faces and rail and stiles as per IS 1003(Pt-I), kiln seasoned and chemically pressure treated etc. complete all as specified and as directed. |
| 61 | Supply and fixing(factory Made) 2nd class hard wood 35 mm thick glazed and skelton shutters open rebated and prepared to receive gauge. (Without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a) supplied and fitted to chowkats complete all as specified and directed . |
| 62 | M & L for Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed. |
| 63 | S&F in repair 20 mm dia curtain rods fancy type, mild steel chromium plated with fixing brackets, stops, rollers complete all as specified and as directed . |
| 64 | S & F Mild steel butt hinges medium weight , cold rolled, 100mm, ISI marked, complete all as specified and as directed . |
| 65 | M&L Aluminium anodised, barrel tower bolts of extruded section and fixed of size 200 mm complete all as specified and as directed . |
| 66 | S&F 150 mm long aluminium anodised handles or extruded section complete all as specified and directed. |
| 67 | S&F 300 mm long Aluninium alloy, anodised , sliding door bolt with hasp , staple,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 68 | S&F Mild steel 300 mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 69 | S&F floor door stopper 140 mm of aluminium alloy body and tongue anodised with hard drawn steel spring complete all as directed by Engineer-in-charge. |
| 70 | Supply & fixing for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm & fixed with tinned tacks, or galvanised wire staples. & directed . |
| 71 | Supply & fixing in repairs for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm & fixed with tinned tacks, or galvanised wire staples. & directed . |
| 72 | Taking down carefully copper/aluminium point wiring from existing points (light, fan, socket or power) alongwith compete fittings such as switches ,ceiling rose, pendent holder, sketch fitting & regulator etc. including making good to the disturbed surfaces of wall, roof and floor etc. to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge. |
| 73 | M&L for point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through and including non metallic rigid PVC casing capping medium grade ISI Marked and all casing capping accessories fixed on wall/fixed to roof/truss/colums etc and including provision of 1.5 sqmm PVC insulated copper acble FRLSH as earth continuty conductor, febricated branded modular metal flush box duly make embossed, conncealed in walls with suitable modular inner and outer plate for housing modular switches, socket outlet and fan regulator etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 74 | All as per Srl item No 73 here-in-before but controlled with one 5 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 75 | All as per Srl item No 73 here-in-before but controlled with one 5 pin socket outlet 5 Amp, independent board with cable 1.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 76 | All as per Srl item No 73 here-in-before but controlled with one 5 pin socket outlet 15 Amp, independent board with cable 2.5 sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 77 | Supply and fix in replacement of switch modular type 15 Amp, 230 Volt, single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 78 | Supply and fix in replacement of socket modular type outlet 5 pin 15 Amp 2-in-one 230 Volt complete all as specified and directed by Engineer -in-Charge. |
| 79 | Supply and fix in replacement of socket modular type outlet 5 pin 5 Amp 2-in-one 230 Volt complete all as specified and directed by Engineer -in-Charge. |
| 80 | Supply and fix in replacement of switch modular type type 5 Amp, 230 Volt, single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 81 | Supply and fix in replacement of Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge. |
| 82 | Supply and fix in replacement of surface & wall mounted LED 20W tube light fitting 4 feet with high quality material and design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over the life time slim integrated design, easy to install efficacy 125 limen/ watt all accessories as specified and directed by Engg-in-Charge. |
| 83 | Supply and fix in replacement of lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. |
| 84 | Supply and fix in replacement of LED lamp 12W energy saving upto 80%, BEE rated with all accessories all as specified and directed by Engg-in-Charge. |
| 85 | Supply and fix in replacement of stepped type electronic fan regulator modular type 120W 2module type on the existing phenolic laminated sheet etc.all as specified and directed by Engg-in-Charge. |
| 86 | Supply and fix in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 87 | Supply and fix in replacement of bulk head light with 10 W LED Lamp complete. |
| 88 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 AC decorativ type with driver jolder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 89 | Supply and fix in replacement of sheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge. |
| 90 | Supply and fix in replacement of MCB SPN 40 Amp,10 KA all as specified and directed by Engineer-in-Charge |
| 91 | Supply and fix in replacement of MCB SP 6 to 32 Amp, 10 KA. all as specified and directed by Engineer-in-Charge. |
| 92 | Supplying and fixing 1100 volts grade heavy duty, XLPE aluminium cable, in service connections,twin core 10 Sqmm Circural cabel, complete all as per specified and directed by Engineer-in-Charge. |
| 93 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/jointing kit/repair of cable and erection of poles complete all as specified and directed |
| 94 | Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed. Note- (i)Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS - 1255-1983 and refilling in trenches as in cable cushioning. (ii) Surplus soil if any shall not be removed but left proud over the trench |
| 95 | M & L for sand filling floors or in foundation incl watering and compansation |
| 96 | M & L for old size bricks common burnt clay building bricks sub class B designation 75 |
| 97 | M&L for taking out old unserviceable and supply, laying, fixing Double walled corrugated HDPE duct pipe of 25 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. |
| 98 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3 connected to earthing testing point all as specified or indicated including testing on completions. |
| 99 | Supply and fixing building LED street light fitting 35w 230 volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver lamp bracket with impact and corrosion resistant incl thermal management in multiple optics complete with IP 65/66 Protection complete, all as specified and directed |
| 100 | Supply & fix exhaust fan made of sturdy engineering plastic complete with louvers shuttter AC, Single Phase 230/240V 300mm sweep 1200 RPM, with louvre complete all as per specified and directed by Engineer-in-Charge Note: Fixing of Exhaust Fan on wall with suitable size anchor bolt , making hole in wall for groutng and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 101 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200 mm sweep, min delivery 210CFM with service value five stat rated with brushless direct current motor (BLDC) complete all as specified and directed |
| 102 | Supply and fix electric Water heater storage type tank and heating element upto 2 KW capacity 25 litres BEE 5 star rated complete with all accessories such as safety valve, thermosate NRV connection pieces etc. Note: Fixing of geyser on wall with suitable size anchor bolt with hammer drill and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 103 | S & F for fixing of GI Pipe bracket of 40mm dia size of 1.2 mtr long bent to shape for fixing of LED Street light fittings and fixing to pole, walls etc including fixing of clamp, nut bolt etc as specified and directed |
| 104 | Schedule of Credit Please Enable Macros to View BoQ information |