| Sl. No. | Item Description |
| 1 | (B/R PORTION)Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil all as specified and directed by Engr in charge. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil all as specified and directed. |
| 3 | Removing excavated material exc 250m but n exc. 500m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil all as specified and directed. |
| 4 | M&L for hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 5 | M&L for PCC 1:3:6 type C2 using 40mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed |
| 6 | M&L for cement concrete 1:2:4 type B1 using 20mm graded aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and directed |
| 7 | M&L for RCC nominal mix 1:2:4 type B1 using 20mm grade aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 8 | M&L for RCC nominal mix 1:2:4 type B1 using 20mm grade aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed |
| 9 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and directed |
| 10 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces complete all as specified and directed |
| 11 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 12 | M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required as in reinforcement and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed |
| 13 | M&L for brickwork with fly-ash bricks (with old size bricks), straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed |
| 14 | M&L for rendering 15mm thick on fair faces of brick work or concrete wall surfaces in CM 1:4 finished rendering is to be finished even and smooth without using extra cement complete all as specified and directed |
| 15 | S&F for liquid water proofing compound complete all as specified and directed |
| 16 | M&L for rendering 10mm thick on fair faces of brick work or concrete wall surfaces in CM 1:6 finished rendering is to be finished even and smooth without using extra cement complete all as specified and directed |
| 17 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 18 | Material and labour for applying two coats of oil bound distemper over one coat of primer on plastered surfaces of wall including preparation of new or previously untreated surfaces all as specified and directed. |
| 19 | S&F powder coated anodised aluminium doors frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified. |
| 20 | S&F aluminium anodised powder coated for doors,windows,ventilators and partition with one or more rebate (Minimum thickness of powder coating 50 micron) and Three track with 1.80 mm thick channel section and shutter frame thickness 1.65 mm without sash bars,Aluminium section weighing 0.55 kg/mtr including necessary joining cleats,glazing clips,rubber packing,anodised aluminium snap beading,screws etc.Complete all as specified and directed. Note:- 1.Size of window shall be as per site requirement. 2. Glass & wire cloth shall be measured separately. |
| 21 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 22 | S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. |
| 23 | S&F 4mm thick ordinary quality sheet glass/frosted glass and glazing with oil putty in square n.exc. 0.5 Sqm in each pane complete all as directed. |
| 24 | S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 25 | M&L for 75mm thick cement concrete type B-1, 1:2:4 using 20mm graded aggregate in plinth protections complete all as specified and directed. |
| 26 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified and as directed. |
| 27 | S&F in False ceiling with 'E' board \\" Classic'' Re inforced, designer series, board with HPSC of size 600x600mmx4mm thick fixed on Powder coated aluminimum snap grid to support the boards/files with powder coated aluminimuum anodised ain 'T section 36mmx25mmx1.40mm ,cross tee 23.50mmx23.50mmx1.40mm thick and aluminium angle 25mm x 25mm x1.40mm as on edges/sides, fixed to ceiling with hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long compelete all as specified and directed |
| 28 | M&L for 100mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) in floors complete all as specified and directed. |
| 29 | M&L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick backing coat in CM 1:4 etc complete all as spd and as directed. |
| 30 | M&L for light shade virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over laid backing coat 10mm thick plaster CM 1:4 complete all as specified and directed. |
| 31 | S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410- W(Gde- E-250) quality- B complete all as specified and directed. |
| 32 | S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe-410- W(Gde- E-250) quality- B complete all as specified and directed. |
| 33 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long and diameter of neck in 16-20 mm complete all as specified and directed. |
| 34 | M&L for new steel and iron surfaces apply two coats of synthetic enamel paint over one coat of red oxide of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed. |
| 35 | Demolition of stone slabs of any description or thickness in floors/vertical surfaces, etc laid, bedded and pointed in any mortar, etc complete all as specifed and directed by Engineer-in-charge. |
| 36 | Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed. |
| 37 | Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and as directed. |
| 38 | M&L 15 mm thick cement plaster on brick or concrete walls finishing fair and even in CM 1:6 complete all as directed. |
| 39 | M&L 25mm thick PCC 1:2:4 Type B-1 ( using 20 mm graded crushed stone aggregate) as in sub base of floor complete all as specified and as directed by Engineer-in-charge. |
| 40 | M&L 20 mm thick ( Z-black colour ) granite slab,machine cut as in steps riser of stair case ,jambs, pillars, window cills, cooking platforms , railing cills and on floor over 15 mm thick backing layer in cement mortar (1:4) , set and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite tile including rubbing and polishing complete all as specified and as directed. |
| 41 | S&F for 12 mm thick clear toughned glass as in partitions, railing , automatic doors, sliding door or hinge door and similar work including cutting to shape, drilling holes required complete all as specified and directed. |
| 42 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing, Grauting with cement mortr(1:3), and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts (covered with stainless steel cap) complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 43 | M&L Preparation of new plastered surfaces of wall and applying two coat of oil bound distermper over a coat of primer and one coat putty (2 mm thick) all as specied and as directed by Engineer-in-Charge. |
| 44 | M&L for complete removal of existing treatment and applying two or more coats of oil emulsion distemper over one coat of primer and one coat putty (2mm thick) to old decorated surfaces of wall complete all as specified and as directed by Engineer-in-Charge. |
| 45 | S&F Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and ointed in white or coloured cement to matchin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade laid over screed bed 20mm thick CM 1:6 complete all as specified and as directed. |
| 46 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed. |
| 47 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each all as directed. |
| 48 | S&F powder coated anodised aluminium window / ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified |
| 49 | S&F Mortice latch lock with two levers (vertical type), mild steel body and fixed in aluminium door complete all as specified and as directed. |
| 50 | S&F 4.8 mm thick tinted selected quality glass and glazing with oil putty in square in each pane fixed in aluminium / Upvc beads (beading included with shutter ) in door , partition , windows , automatic doors and similar work including cutting to shape , drilling holes as required complete all as specified and as directed. |
| 51 | S&F Door closer hydrau- lically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg andfixed and fixed inclding taking down old one all as directed. |
| 52 | S&F floor door stopper of aluminium alloy body and tounge, anodised, with hard drawn steel spring, fixed in floor. 150mm overall length of cover plate complete all as specified and as directed. |
| 53 | S & F solar control film 25 micron reflective type (garware sun control or equivqlent ) complete all as specified and directed . |
| 54 | S&F stainless steel wire cloth, 0.65mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as directed. |
| 55 | M&L for 1st class soft wood ,Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints specified and directed. |
| 56 | M&L for 40 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and both face is covered with deco rative face veneer with lipping / frame to match complete |
| 57 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door Frames/ Chowkhat of size 45 x 85-90 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp- ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). → Note: For WPC solid door minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 58 | S&F Providing and fixingf actory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 59 | M&L for applying two or more coat of french polish including preparing, claening the new surface and applying wood filler on new wooden surfaces of any description over 10cm width or girth complete all as directed by Engineer-in-Charge. |
| 60 | S&F hold fast for window & doors, made to shape as required all as directed at site complete all as specified and as directed. |
| 61 | S & F 200 mm long Brass Finish anodised barrel tower bolt of extrued section complete all as specified and as directed. |
| 62 | S&F 300 mm long Brass Finish anodised sliding door bolt with hasp staple (bolt type) and fixing clip of shut cast or extruded section and fixing bolts and sliding bolts of extruded section as cast aluminium alloy complete all as specified and as directed. |
| 63 | S&F 100 mm long butt hinges MS medium weight cold rolled complete all as specified and as directed. |
| 64 | S&F in repair Block boards 18 to 19 mm thick, grade 2 quality, i n t e r i o r grade, commercial type, fixed with screws to timber frame-work( as in cup board) INCL taking down old one complete all as specified and as directed. |
| 65 | S&F Decorative laminate type ( 0.9 mm thick) of surface finish, colour and pattern as approved, fixed with approved adhesive as per anufacturer's instructions complete all as specified and as directed. |
| 66 | S & F Continuous (piano) brass hinges ,SS, bright finish or electrogalvanised, width of flap 40 mm complete all as specified and as directed. |
| 67 | S&F 150 mm Extruded brass handles, fabricated type polished decorative type complete all as specified and as directed. |
| 68 | S&F brass multi purpose cupboard lock , size 75 mm , 4 lever complete all as specified and as directed. |
| 69 | M&L Providing precast reinforced cement concrete RCPC drain cover 100 mm thick of size 900 x450 mm as in drain cover with capacity 5 MT of approved make placed in position complete all as specified and as directed. |
| 70 | Dismantling plain or corrugated steel sheeting any gauge thickness including nanital or similar pattern roof covering all as specified and directed.Note :-Any height of bldg |
| 71 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise all as specified and directed ; |
| 72 | M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7/ 300x600x7mm etc thick set and jointed in neat cement slurry and pointed in white or colour cement to match and over laid backing coat 10mm thick plaster CM 1:4 complete all as specified and directed. |
| 73 | M&L for Virified Dark shade/ Double charged/Ultra charged Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match and over laid screed bed 15mm thick cement mortar 1:4 all as specified and directed. |
| 74 | S&F for Steel work in tubular trusses in roof trusses (framed), trussed, posts, purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed |
| 75 | S&F Aluminium anodised Powder coated for doors, windows, ventilators and partition with one or more rebate (minimum thickness of powder coating 50 micron) without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed. |
| 76 | S&F for Anodised aluminium powder coating 50mm thick micron door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. |
| 77 | Material and labour for brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:6 all as specified and directed. |
| 78 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing downwith water, etc. all as specified and directed. |
| 79 | Dismantling framed timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq.cm in section and removing from site all as specified and directed. |
| 80 | (E/M PORTION)M&L for surface point wiring using approved colour coding as per IS (For phase and neural), with stranded copper conductor 1.5 Sqmm (nominal area), single core, multistranded, FRLSH , PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked drawn in and including heavy duty PVC concealed conduit with fittings ISI marked, terminated in junction box incl 1.5 Sqmm and connected to earth dolly including fixing of 1. 2 mm thick MS sunk terminal box 60 mm deep (minimum size 100 x 100 mm square) suitably flushed to wall with 3 mm thick plastic laminated/ebonite sheet cover fixed with brass screws and cup washers incding making good the disturbed surfaces complete all as specified and directed. |
| 81 | All as per item No 80,here-in-before but one light point controlled by one switch/one fan point/one bell or buzzer controlled by one switch & fan regulator. |
| 82 | All as per item No 80,here-in-before but one 3/5 pin socket outlet, 5 Amp on the same board with other switches |
| 83 | All as per item No 80 here-in-before but one socket outlet three pin, 5 Amps on the independent board. |
| 84 | S&F Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 85 | S&F Ceiling rose surface type 3 terminals 65x20mm complete all as specified and directed. |
| 86 | S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 87 | S&F White cover plate with frame, 2 module complete all as specified and directed. |
| 88 | S&F White cover plate with frame, 3 module complete all as specified and directed. |
| 89 | S&F White cover plate with frame, 4 module complete all as specified and directed. |
| 90 | S&F White cover plate with frame, 6 module complete all as specified and directed. |
| 91 | S&F White cover plate with frame, 8/12 module complete all as specified and directed. |
| 92 | S&F Metal flush box 1/2 module complete all as specified and directed. |
| 93 | S&F Metal flush box 3 module complete all as specified and directed. |
| 94 | S&F Metal flush box 4 module complete all as specified and directed. |
| 95 | S&F Metal flush box 6 module complete all as specified and directed. |
| 96 | S&F metal flush box, 8/12 module complete all as specified and directed. |
| 97 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity 6-32 Amps in the MCB DB complete with connection testing and commissioning. |
| 98 | Supply and fixing SPN 40 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.complete all as specified and directed. |
| 99 | S & Fix Energy efficient light fitting (LED ) Batten fitting 4FT (Cute linea,surface &wall mounting LED 4ft batten with extruded synthetic housing,3\\" X3\\" PVC block 2 Nos,Lamps,driver,connector etc incl hanging arrangement with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting through suitable size flexible PVC pipe making good to wall for old fitting including taking down old fitting of complete all as specified and directed. |
| 100 | S & F MCB DB, SPN 8 Ways Single Door IP-43 with rated bus bars earth bar, neutral links complete incl blanking plates as required & fixed flush to wall and making good the disturbed surfaces complete all as specified and as directed. |
| 101 | M & L for sub main wiring for single phase with single core PVC insulated unsheathed , 1100 Volts grade, (FRLS) copper cable 6 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring.Note :-(i) One run of PVC conduit, four runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. |
| 102 | Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and directed. |
| 103 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core |
| 104 | M & L for point wiring with 4.00 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade for 3 Pin socket outlet 15 Amps on independent board with PVC conduit (ISI Marked) medium duty not less than 20mm dia with accessories such as elbow, tees,internal & external bend etc. of suitable size including continuous earth wire FRLS PVC insulated 4.00 Sq mm copper multi stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified. Note : 1) Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. 2) Necessary chase cutting for conduits if requires, shall be measured & paid separately under respective items in this schedule. |
| 105 | S&F modular Switch Socket combination outlet 6 pin 16 Amps flush type complete all as specified and directed. |
| 106 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunsheds, shelves, lintel etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting n exc 10 cm girth on brick wall all as directed |
| 107 | S&F sheet metal enclousure double Door IP-43 with triple pole and neutral 415 V 8 way rated bus bars earth bar, neutral links complete incl blanking plates as required & fixed flush to wall and making good the disturbed surfaces complete all as specified and as directed. |
| 108 | Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications |
| 109 | M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180Cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured. |
| 110 | Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed. |
| 111 | Earthing for poles & other machinery/equipment using 4 m GI wire as earthing lead and MS galvanized plate of size 60 cm x 60 cm x 6 mm, as earth electrode complete all as specified and as directed. |
| 112 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core. |
| 113 | Supply and fixing ceiling fans complete with blades, down rods, Electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 114 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 115 | Supply , installation and commissioning of 3 phase 415 Volts ,Air Cooled Vertical type Air conditioner energy efficient with minimum 3 star rating indoor and Outdoor Complete with Cordless remote control unit , Scroll compressor of Capacity 3.0TR complete all as specified and directed. |
| 116 | Supply and draw submain wiring with four single core 10 sq mm FRLS PVC insulated copper cable 1100 volts grade multi stranded, un sheathed conductor in PVC Casing Capping and 10 sq mm multi-strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete all as specified and as directed. |
| 117 | Supply and laying refrigerant line copper tubing of size 5/8 \\" with clamping on wall surface or concealed with both the ends connection complete all as specified and as directed. |
| 118 | All as per item Ser No 117 here - in - before but of size 3/8 \\" |
| 119 | S&F Nitrile Rubber insulation for copper tubing of size 5/8'' dia duly wrapped complete all as specifed and directed. |
| 120 | S&F Nitrile Rubber insulation for copper tubing of size 3/8'' dia duly wrapped complete all as specifed and directed. |
| 121 | S & F drain pipe 5/8\\" dia PVC jacketed heavy duty with fixing of clamp complete all as specified and as directed. |
| 122 | Supply and fixing angle iron brackets bracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats of suitable size etc including nuts, ,bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 123 | M&L for sheet metal enclosure for DBs SPN 4 way 240 V, with 200 A rated bus bar double door, complete flush mounted all as specified and as directed |
| 124 | Supply and fixing copper cable 6.0 sqmm 4 core duly connected and properly clamped from indoorunit to Outdoor unit complete all as specified and directed |
| 125 | S & F TP&N Vertical Loadline Dbs are fitted with Bus Bars, Neutral Links, Blanking Plates 4 way double door DB LL 4W DD VERT W/O MCCB.complete all as specified and directed. |
| 126 | S & F MCCBs 415V, 16KA, 4 Pole 100Ampscomplete all as specified and directed. |
| 127 | S & F MCB 'C' curve single pole neutral , 32 Amps with breaking capacity 10kA complete all as specified and directed |
| 128 | Materials and Labour for surface type point wiring with 4.00 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.(a) One light point or one fan point or bell point controlled by one switch or bell push |
| 129 | Supply and fixing Water Heater Storage type BEE 5 Star rated of Capacity 25 Litre, Power Rating of 2000 Watt ,Maximum Water Temperature 75 degree, Rated Pressure 0.8 Mpa having titanium coating inside Tank (Minimum thickness 0.2mm) and mild steel tank of thickness minimum 1.8 mm after taking out old unsv geysers as directed by Engr-in-Charge. |
| 130 | S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush mounting enclosure with 2 pin earth plug socket complete all as specified and directed by engineer in charge. |
| 131 | Supply and fix GI tubing medium grade of size 15 mm dia with all fittings such as tees elbows nipples union socet complete laid in floors wall ceiling complete all as specified and directed. |
| 132 | Supply and fix bib taps, fancy type chromium plated cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified. |
| 133 | Supply and fix stop valves,fancy type chromium plated screwed pressure, with long shunk and cup crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified. |
| 134 | S & F Chromium plated brass connecting pipe of size 15 mm dia 600 mm long with brass coupling and union at both ends heavy duty suitable for fix on 15 mm dia GI pipe with washer complete all as specified and as directed. |
| 135 | M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through & including PVC conduit of suitable size in Surface/concealed all as directed. |
| 136 | Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail