| Sl. No. | Item Description |
| 1 | Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. |
| 2 | Earthwork in excavation in foundation trenches or drains, in all sorts of soil ( including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils within a lead of 75 m as directed including trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. a) Depth of excavation not exceeding 1500mm |
| 3 | b) beyond 1500mm to 3000 mm depth |
| 4 | Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete.( Payment to be made on the basis of measurement of finished quantity of work ). a) With earth obtained from excavation of foundation. |
| 5 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 6 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 7 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches |
| 8 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes |
| 9 | 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per man surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C). |
| 10 | Brick work with 1st class bricks in cement mortar (4:1) a) In foundation and plinth. |
| 11 | Brick work with 1st class bricks in cement mortar (6:1) b) In super structure In Ground Floor |
| 12 | Brick work with 1st class bricks in cement mortar (6:1) b) In super structure In 1st Floor |
| 13 | Brick work with 1st class bricks in cement mortar (6:1) b) In super structure In 2nd Floor |
| 14 | 125 mm thick brick work in cement mortar in (4:1) in ground floor |
| 15 | 125 mm thick brick work in cement mortar in (4:1) in 1st floor |
| 16 | 125 mm thick brick work in cement mortar in (4:1) in 2 nd floor |
| 17 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety In Ground Floor |
| 18 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety In 1st Floor |
| 19 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety In 2 nd Floor |
| 20 | Reinforcements for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16G black annealed wire at every inter-section, complete as per drawing and direction.a) In foundation & Ground Floor a) For works in foundation, basement and upto roof of ground floor / upto 4m. II)JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL (Tor Steel/ HYSD) In Ground Floor |
| 21 | Reinforcements for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16G black annealed wire at every inter-section, complete as per drawing and direction.a) In foundation & Ground Floor a) For works in foundation, basement and upto roof of ground floor / upto 4m. II)JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL (Tor Steel/ HYSD) In 1st Floor |
| 22 | Reinforcements for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16G black annealed wire at every inter-section, complete as per drawing and direction.a) In foundation & Ground Floor a) For works in foundation, basement and upto roof of ground floor / upto 4m. II)JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL (Tor Steel/ HYSD) In 2nd Floor |
| 23 | 75 mm thick Brick Work in cement morter in (4:1) in ground Floor |
| 24 | 75 mm thick Brick Work in cement morter in (4:1) In 1st Floor |
| 25 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintelscurved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor).(When the height of a particular floor is more than 4 m. the equivalent floor ht. shall be taken as 4 m. and extra for works beyond the initial 4 m. ht. shall be allowed under 12(e) for every 4 m. or part thereof.) f) 25 mm to 30 mm shuttering without staging in foundation |
| 26 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintelscurved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor).(When the height of a particular floor is more than 4 m. the equivalent floor ht. shall be taken as 4 m. and extra for works beyond the initial 4 m. ht. shall be allowed under 12(e) for every 4 m. or part thereof.) a) 9 mm to 12mm thick ply board or Steel shuttering AT GROUND FLOOR |
| 27 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintelscurved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor).(When the height of a particular floor is more than 4 m. the equivalent floor ht. shall be taken as 4 m. and extra for works beyond the initial 4 m. ht. shall be allowed under 12(e) for every 4 m. or part thereof.) a) 9 mm to 12mm thick ply board or Steel shuttering AT 1 st FLOOR |
| 28 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintelscurved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor).(When the height of a particular floor is more than 4 m. the equivalent floor ht. shall be taken as 4 m. and extra for works beyond the initial 4 m. ht. shall be allowed under 12(e) for every 4 m. or part thereof.) a) 9 mm to 12mm thick ply board or Steel shuttering AT 2 ND FLOOR |
| 29 | Labour for chipping concrete surface before plaster at Ground Floor |
| 30 | Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary. A) With 6:1 cement mortar. a) Inside wall 20 mm thick plaster In Ground Floor |
| 31 | A) With 6:1 cement mortar. a) Inside wall 20 mm thick plaster In 1ST Floor |
| 32 | A) With 6:1 cement mortar. a) Inside wall 20 mm thick plaster In 2nd Floor |
| 33 | A) With 6:1 cement mortar. a) Ceiling Plaster 10 mm thick plaster In Ground Floor |
| 34 | A) With 6:1 cement mortar. a) Ceiling Plaster 10 mm thick plaster In 1st FLOOR |
| 35 | A) With 6:1 cement mortar. a) Ceiling Plaster 10 mm thick plaster In 2nd FLOOR |
| 36 | A) With 6:1 cement mortar. b) Out side Wall, 15mm th. Ground Floor |
| 37 | A) With 6:1 cement mortar. b) Out side Wall, 15mm th. 1ST Floor |
| 38 | A) With 6:1 cement mortar. b) Out side Wall, 15mm th. 2ND Floor |
| 39 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick). In Ground Floor |
| 40 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick). In 1ST Floor |
| 41 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick). In 2nd Floor |
| 42 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.Two CoatsIn Ground Floor |
| 43 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.Two Coats in 1ST Floor |
| 44 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.Two Coats in 2nd Floor |
| 45 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e)(I) With lication slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colour In Ground Floor |
| 46 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e)(I) With lication slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colour In 1ST Floor |
| 47 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a)(b) Area of each tile above 0.09 Sq.m (i) Coloured decorative In Ground Floor |
| 48 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a)(b) Area of each tile above 0.09 Sq.m (i) Coloured decorative In FirstFloor |
| 49 | (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) (b) Area of each tile above 0.09 Sq.m (ii) Other than Coloured decorative including whiteIn Ground Floor |
| 50 | (B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry Sq.m. (a) (b) Area of each tile above 0.09 Sq.m (ii) Other than Coloured decorative including whiteIn 1st Floor |
| 51 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(i) In Ground Floor |
| 52 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(i) In First Floor |
| 53 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and od veneers using phenol formaldehyde as in position but excluding the cost of hinges and other fittings in ground floor.(b) 32 mm thick shutters (single leaf). (i) Ground Floor |
| 54 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and od veneers using phenol formaldehyde as in position but excluding the cost of hinges and other fittings in ground floor.(b) 32 mm thick shutters (single leaf). (i) 1st loor |
| 55 | Supplying, Fitting & Fixing Factory made P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out .V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per anufacturer‟s specification and direction of Engineer-in-Charge ( In Ground Floor) |
| 56 | Supplying, Fitting & Fixing Factory made P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out .V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per anufacturer‟s specification and direction of Engineer-in-Charge ( In 1st Floor) |
| 57 | Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made ck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as perdirection of Engineer-in-ChargeIn ground floor. |
| 58 | Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made ck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as perdirection of Engineer-in-Charge.In 1st floor |
| 59 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.In ground floor. |
| 60 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both+B151 faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. ( In Ground Floor) |
| 61 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both+B151 faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. ( In 2nd Floor) |
| 62 | Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural whiteunit wt of to Top & side frame @1.366 kg/m ; top rail @ 1.296 kg/m; bottom rail @ 1.974 kg/m; lock rail @ 1.590 kg/m; door vertical @ 1.412 kg/m; glazing clip @ 0.167 kg/m. )[Note : for estimate purpose construction wing may consider weight of Aluminium door @ 9.0 Kg per Sq.M |
| 63 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film door, sliding & casement windows, partitions, d length of the work).(A) In 10-12 Micron thickness Annodizing film I) Natural white g) Fixed glazing i) Top, bottom and side member IN GROUND FLOOR |
| 64 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film door, sliding & casement windows, partitions, d length of the work).(A) In 10-12 Micron thickness Annodizing film I) Natural white g) Fixed glazing i) Top, bottom and side member IN 1st FLOOR |
| 65 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film door, sliding & casement windows, partitions, d length of the work).(A) In 10-12 Micron thickness Annodizing film I) Natural white g) Fixed glazing i) Top, bottom and side member IN 2nd FLOOR |
| 66 | Supplying, fitting & fixing MS clamp for fixing door and window frame made of flat bent bar, end bifurcated, fixed in cement concrete with stone chips (4:2:1)a fitted and fixed omplete as per direction.40mm x 6mm x 125 mm length.(Cost of cement concrete will be paid separately) ( In GROUND FLOOR+1st FLOOR) |
| 67 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 6 mm thick coloured / tinted / smoke glas (In Ground Floor) |
| 68 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 6 mm thick coloured / tinted / smoke glas (In 1st Floor) |
| 69 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 6 mm thick coloured / tinted / smoke glas (In 2nd Floor) |
| 70 | (A) Supplying Aluminium casted body hydraulic door closer as per I.S.I. ( In Ground floor) |
| 71 | (C) Supplying Heavy Duty Aluminium Handle (EBCO Type) (Natural White) (In Ground Floor) |
| 72 | (a) Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete. ( In Ground Floor) |
| 73 | (ii) Door stopper (Anodised aluminium) ( In Ground Floor+1st Floor) |
| 74 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with od damages to match with existing surface complete in all respect excluding glazing. In Ground Floor.(viii) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. In Ground Floor |
| 75 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with od damages to match with existing surface complete in all respect excluding glazing. In Ground Floor.(viii) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. In 1st Floor |
| 76 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with od damages to match with existing surface complete in all respect excluding glazing.(viii) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. In 2nd Floor |
| 77 | (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]. In Ground Floor (W1) |
| 78 | (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]. In 1st Floor (W1) |
| 79 | Supplying, fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top, bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloyextrusionsconformingtoIS733-1983&IS1285-1975,annodised conforming toIS1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, Maruti lock, screws etc. including labour charges for fitting &fixing of aluminium2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing filmFor 2-Trackwindow: Members for Bottom frame @0.875KgperMtr. and for Top and Side frame @0.778Kg per Mtr. And for shutter Bottom and Top member @0.472Kgper Mtr., Style side member @0.493Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window: Members for Bottom frame @1.233Kg per Mtr. And for Top and Side frame @1.067Kg per Mtr. And for shutter Bottom and Top member @0.472Kg per Mtr., Style side member @0.493Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. Natural white ( In Ground Floor) |
| 80 | Supplying, fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top, bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloyextrusionsconformingtoIS733-1983&IS1285-1975,annodised conforming toIS1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, Maruti lock, screws etc. including labour charges for fitting &fixing of aluminium2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing filmFor 2-Trackwindow: Members for Bottom frame @0.875KgperMtr. and for Top and Side frame @0.778Kg per Mtr. And for shutter Bottom and Top member @0.472Kgper Mtr., Style side member @0.493Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window: Members for Bottom frame @1.233Kg per Mtr. And for Top and Side frame @1.067Kg per Mtr. And for shutter Bottom and Top member @0.472Kg per Mtr., Style side member @0.493Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. Natural white ( In 1st Floor) |
| 81 | Supplying, fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top, bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloyextrusionsconformingtoIS733-1983&IS1285-1975,annodised conforming toIS1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, Maruti lock, screws etc. including labour charges for fitting &fixing of aluminium2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing filmFor 2-Trackwindow: Members for Bottom frame @0.875KgperMtr. and for Top and Side frame @0.778Kg per Mtr. And for shutter Bottom and Top member @0.472Kgper Mtr., Style side member @0.493Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window: Members for Bottom frame @1.233Kg per Mtr. And for Top and Side frame @1.067Kg per Mtr. And for shutter Bottom and Top member @0.472Kg per Mtr., Style side member @0.493Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. Natural white ( In 2nd Floor) |
| 82 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. a)75mm x 47mm x 1.70mm (In Ground floor+1st Floor) |
| 83 | Iron Socket Bolt of approved quality fitted and fixed complete. i) 150 mm long x 10 mm dia ( In Ground Floor+1st Floor) |
| 84 | i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. c) 300mm long. ( In Ground Floor+ 1st Floor) |
| 85 | Anodised aliminium D-type handle of approved quality manufactured fromextruded section conforming to I.S. specification (I.S. 230/72) fitted and fixedcomplete: (b) With round base: (iv) 150 mm grip x 10 mm dia rod (In Ground Floor+ 1st Floor) |
| 86 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing 10 kg/sq m to16 kg/m2. In Ground Floor |
| 87 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing 10 kg/sq m to16 kg/m2. In 1st Floor |
| 88 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing 10 kg/sq m to16 kg/m2. In 2nd Floor |
| 89 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. In Ground Floor |
| 90 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. In 1st Floor |
| 91 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :With super gloss (hi-gloss)-With any shade except white. b) On Steel surface Two Coats ( Ground Floor) |
| 92 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :With super gloss (hi-gloss)-With any shade except white. b) On Steel surface Two Coats ( 1 st Floor) |
| 93 | b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. ( In Ground Floor) |
| 94 | b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. ( In 1st Floor) |
| 95 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by if necessary :With super gloss (hi-gloss)-With any shade except white. a) On timber or plastered surface Two Coats ( In Ground floor) |
| 96 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by if necessary :With super gloss (hi-gloss)-With any shade except white. a) On timber or plastered surface Two Coats ( In 1st floor) |
| 97 | Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement including cost of materials, labour, scaffolding, staging curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] (In Ground Floor) |
| 98 | Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement including cost of materials, labour, scaffolding, staging curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] (In 1st Floor) |
| 99 | Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone. |
| 100 | Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps. |
| 101 | Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, . [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety (i) 25 mm. thick ( In Ground Floor) |
| 102 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4)withstonechips, laid inpanelsasdirectedwith topping made with ordinary or white cement (asnecessary) andmarble dust in proportion (1:2) includingsmooth finishingand roundingoff corners including raking out jointsorrougheningofconcretesurfaceand application of cement slurrybefore [email protected] ground floor. 3mm. thick topping(Highpolishinggrindingonthis itemis not permitted with ordina( Water Reservoir+ Roof)Using grey cement (ii) 25 mm. thick |
| 103 | Supplying and Laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks (with Concrete grade as specified as per Table 1 of IS 15658: 2006) manufactured from BIS licensee manufacturer, with spacer nib (Small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per Cl. No 3.26 of IS: 15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per Cl. No. 3.3 of IS: 15658) as per Table 2 of IS: 15658 with flexural strength/breaking load as per Annexure G of IS: 15658, on the prepared base course of specified CBR as per Table 1 of IRC SP 63 (2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35 mm thick (grading of the bedding sand as per clause 6.5.1 of IRC SP-63) and filling up the gaps in between paver blocks with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per Cl. No. 8.7 of IRC SP – 63 (2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edge gap.50 mm thick. Coloured Decorative |
| 104 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. |
| 105 | (ii) UPVC Bend 87.5 degree 110 mm dia |
| 106 | (iii) UPVC Shoe 110 mm |
| 107 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor(b) Two Coats |
| 108 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In 1st Floor(b) Two Coats |
| 109 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In 2nd Floor(b) Two Coats |
| 110 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Normal Acrylic Emulsion Grund Floor |
| 111 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Normal Acrylic Emulsion 1st Floor |
| 112 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Normal Acrylic Emulsion 2nd Floor |
| 113 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (i) CPVC Pipes Class-1, SDR-11 a) For Exposed Work 20 MM DIA |
| 114 | 25 MM DIA |
| 115 | 40 MM DIA |
| 116 | (b) For Concealed Work 20 mm Dia (class II) |
| 117 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. markng with fittings(tested to 21 kg/sq.cm.).20 MM DIA |
| 118 | 32 MM DIA |
| 119 | 40 MM DIA |
| 120 | Supplying, fitting and fixing bib cock or stop cock.a(i) Chromium plated Bib Cock short with wall flange with aerator (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand |
| 121 | B(i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 122 | Suppling,fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc. a)with 'P' trap |
| 123 | Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws supplied, fitted and fixed complete.(a) E.W.C. (ii) Plastic (hallow type) white |
| 124 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pip |
| 125 | Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(iv) 600 mm long |
| 126 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats ofapproved paint.(ii) 550 mm X 400 mm size |
| 127 | Supplying, fitting and fixing pedestal of approved make for wash basin (white) |
| 128 | Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.(a) Sink only (i) 530 mm X 430 mm x 180 mm |
| 129 | Supplying, fitting and fixing pillar cock of approved make.a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 130 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I, specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 131 | Supplying fitting and fixing towel rail with two brackets a)C.P. over brass (iii) 25mm dia and 600mm long |
| 132 | Supplying, fitting and fixing soap holder. (b) Fibre glass |
| 133 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) – Multilayer (g) 4000 litre capacity |
| 134 | Labour for hoisting plastic water storage tank.(ii) Above 1500 litre upto 5000 litre capacity |
| 135 | b) Extra for each additional story |
| 136 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 137 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make supplied, fitted and fixed in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.(ii) 470 mm X 280 mm X 340 mm |
| 138 | Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (a) C.P. urinal flush pipe fittings range of one. |
| 139 | Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).(i) 450 mm X 350 mm |
| 140 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit,providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved makesupplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL) |
| 141 | Construction of septic tank of different capacities as per approved drawing with 1stclass brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manholecover(heavy type)of approved make supplied, fitted and fixed in the 100mm thickR.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1)with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc....(ii) For 20 usersA) With Pakur variety.(JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL) |
| 142 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having ISO mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement concrete.(JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL) |
| 143 | Cutting hole through wall,roof or cornice and mending good all damages. |
| 144 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Length a) 75 mm |
| 145 | (b) 110 mm |
| 146 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. (B) Fittings (i) Coupler (a) 75 mm |
| 147 | (b) 110 mm |
| 148 | (ii) Plain Tee (a) 75 mm |
| 149 | (b) 110 mm |
| 150 | (iii) Door Tee (b) 110 mm |
| 151 | vi) Door Y (LH) & (RH) (b) 110 mm |
| 152 | x) Bend 87.5º (a) 75 mm |
| 153 | (b) 110 mm |
| 154 | xi) Door Bend (T.S.) |
| 155 | xiv) Cross Tee with Door (a) 75 mm |
| 156 | (b) 110 mm |
| 157 | xv) Vent Cowl |
| 158 | xvi) Pipe Clip (a) 75 mm |
| 159 | (b) 110 mm |
| 160 | xviii) W.C. Connector (450 mm long) W / lipring(a) 75 mm |
| 161 | xxiii) 110/110 S Trap |
| 162 | xxvi) Reducer 110 X 75 mm |
| 163 | xxvii) Reducing Tee (110 X 75 mm) |
| 164 | xIix) Door Gasket |
| 165 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor)...(A) Above ground (a) 75 mm |
| 166 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor)...(A) Above ground (b)110 mm |
| 167 | Supplying, fitting and fixing C.I. round grating.150 mm dia |
| 168 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 169 | (d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). |
| 170 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewel(a) For depth upto 150 metre (i) (ii) 50 mm dia. boring etc. |
| 171 | Supplying, fitting and fixing heavy type bell mouth reducing socket. 50mm X 100 mm |
| 172 | Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required. |
| 173 | Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete. |
| 174 | Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. |
| 175 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-in-charge including cost of all materials labour and equipment complete. |
| 176 | Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete. |
| 177 | Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. |
| 178 | Providing 200 mm centre guide.i) With Clamp |
| 179 | Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report. |
| 180 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239(Part - I).I) 50 MM DIA |
| 181 | II) 100 MM DIA |
| 182 | (iii) End Plug --100 mm (Dia) |
| 183 | (iv) Threaded End Cap --100 mm (Dia) |
| 184 | (v) Solvent cement |
| 185 | Supplying M.S. male/ female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per direction of the Engineer - in - Charge.(i) 100 mm dia |
| 186 | Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge(a) 100 mm nominal dia(i) 6.00 mm wall thickness |
| 187 | Supply, delivery at site, installation, testing and commissioning of Floor mounting, cubicle pattern, dust & vermin proof generally conforming to IP-54 Degree of Protection, indoor duty, industrial type LT PDB cum Panel made of 2 mm thick CRCA sheet steel, painted with powder coating finish paint.The Panel shall be completely wired up with following components: i) 1 No. 50 A FP MCB (10kA-C Curve) ii) 4 Nos 32 A DP MCB (10kA-C Curve) iii) 1 No.63 A On-load front operated change over switch iv) 240 V, 63A, 2-bar Al bar sheet metal iron clad busbar chambers v) 1 no. 0-100A Ammeter with selector switch vi) 1 no. 0-500V Voltmeter with Selector switch vii) 1 Set R-Y-B LED Type Phase Indicating Lamp etc. as required as per direction of EIC. |
| 188 | S & F 230V.6-10A per way, 2+8 way SPN MCB DB with SS enclosure double door (make- Legrand, cat. no. 607711) with IP-42/43 protection with 63A DP Isolator as incomer and 8 nos. SP MCB 6-32 A (‘C’ curve 10KA) as outgoing, concealed in wall after cutting the wal & mending good the damages to original finish including interconnection with suitable size of copper wire and neutral link provision for earthing attachment. |
| 189 | Supplying and fixing 19 mm dia 3 mm thick polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) |
| 190 | Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe 19 mm dia 3 mm thick with 1x14 SWG GI earth continuity wire, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl mending good damages to building works. |
| 191 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. a) 2 x 2.5 mm² + 1 x 1.5 mm² as ECC |
| 192 | b) 2 x 4 mm² + 1 x 2.5 mm² as ECC |
| 193 | c) 2 x 6 mm² + 1 x 4 mm² as ECC |
| 194 | Distribution wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCa) Average run 6 M |
| 195 | b) Average run 9 M |
| 196 | Distribution wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCa) On Board |
| 197 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall with putty or wooden polish finished must be completed with colour finished as per existing incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.and mending good the damages to original finish. |
| 198 | Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall must be finished with putty or wooden polish finished must be completed with colour finished as per existing incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 199 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 200 | Supplying & Fixing sheet metal inspection box of size 150 mm x 100 mm x 65 mm (16 SWG) s flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building work |
| 201 | Supply & fixing philips Smartbrite Xtra 4 ft LED batten tube light icluding fixing only fluorescent light fitting suspended 25 cm below the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length.Make: Havells, 20 W LED |
| 202 | Supply & fixing philips Smartbrite Xtra 2 ft LED batten tube light, 12 Watt icluding fixing only fluorescent light fitting suspended 25 cm below the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. |
| 203 | Supply , Delivery at site 1200mm sweep ,230 V, 1 Ph., 50 Hz Ceiling fan complete as per specification & Direction of the EIC. |
| 204 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 205 | Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) |
| 206 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 207 | Supply and delivery of 230V,50Hz Heavy duty Metal 23 cm (9\\") exhuast fan as per direction of EIC. |
| 208 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of 23 cm (9\\")diameter. |
| 209 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below by ISI Medium GI Pipe. |
| 210 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode & r providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe. |
| 211 | Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on complete painted colour finished wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 212 | Supply & delivery of 50 Watt LED Street Light fitting complete with all accessories as per direction of the EIC. |
| 213 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint |
| 214 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 215 | Supply, installation, testing & commissioning of 6 kVA/ 4.8 kW, 3 Phase INPUT and 1 Phase OUTPUT Offline UPS System with SMF Battery bank for 60 Mins. backup, having following Specification : Offline UPS with built-in Isolation Transformer to run Fan & Light load catered to 3 different phases Voltage Range Input -- 300V-480V AC, Frequency-46 to 54Hz, Output--230V AC Phase to Neutral (+/- 1%) on 100% load, Frequency-50 Hz +/- 0.5%, Output Power Factor: 0.8 or better, Efficiency >=92% on rated full load, DC Voltage- 120V DC. Minimum VAH for 60Mins. back up 7800 VAH; Battery make -Exide/Quanta,Including Battery Rack, Inter Connection of above Batteries with Suitable copper interlinks, Lugs etc. as required Quality Certification: ISO 9001:2015; ISO 14001:2015; ISO 50001:2018: & ISO 45001: 2018 as per direction of the EIC. |
| 216 | Supply, Installation of 3 Star, 180 Litres, Single Door Refrigerator as per direction of the EIC. |
| 217 | Supply and Fixing of 2 mm Polyvinyl glow sign board made of 22 SWG GI sheet box with 1”X1” aluminum channel for fixing the vinyl board after necessary cutting the letter as required & s\f LED tube light fittings along with all accessories. |
| 218 | Supply and delivery of clear water vertical wet type submersible pump suitable for minimum bore well dia of 100 mm conforming to IS : 8034 ( and as amended there after ) with standard MOC for potable clear cold water and BEE 3 Star Rated.capable of discharging 5 M³/hr against 43 M Head of water column. The pump shall be directly coupled with a continuous rated 2- pole suitable wet type vertical squinel cage induction motor conforming to IS : 9283 (and as amended thereafter ), suitable for operation in AC Single phases 220V,50Hz (category B motor) |
| 219 | Supply and delivery of direct on line ( DOL) strater panel board conforming to ISl3947 and IEC 947 of suitable HP rating for operation in 230V (±10%) AC, single phase, 50HZ (±5%) comprising of ammeter, voltmeter, thermal overload relay,2 pole magnetic contactor, under voltage protection, indicating lamp, capacitors, on/off push buttons including 5 way connector, wiring with l/1.5 sq. mm PVC insulated copper wire, powder coated vermin proof box of following capacities:-i. 1.5 H.P. (Relay Range 9-14 Amp.) |
| 220 | S & F Protective device comprising of wire rope, clamps etc. |
| 221 | Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo,nipple, longscrew, reducing socket, reducing tee,short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground.a) 50 mm dia medium |
| 222 | Installation, testing and commissioning of submersible pump-motor set incl. all accessories after lowering down the set along with coloumn pipes in a new well.This item is incl. by S & F MS ( 4.85 mm thick) cover for tube well and one no. bend and two nos. holding clamp ( 75mm × 12mm) for column pipe and also included arrangement for chain pulley blocks, tools, tackles and their all type of transportation. |
| 223 | Supplying, fitting and fixing check valve (horizontal) G.M. tested to 21 kg./cm2 |
| 224 | Supplying, fitting and fixing of 40 mm dia Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings(tested to 21 kg./cm2) |
| 225 | Supply, delivery & laying of 1.1 kV grade 3 Core 2.5 mm2 copper submersible flat cable. |
| 226 | Add @ 1 % L.W.C on Sl. No. 1 to 167 |
| 227 | Add @ 18 % G.S.T on Sl. No. 1 to 168 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail