| 1 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 3 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 4 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 5 | Providing P.C.C. M-15 Nominal Mix (1:2:4) in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I, |
| 6 | Providing R.C.C. M-200 with nominal mix of [1:1.5:3] in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing [but excluding the cost of reinforcement] taxes and royalty all complete as per building specification and direction of E/I. |
| 7 | Providing R.C.C. M-200 with nominal mix of [1:1.5:3] in columns with approved quality of stone chips 20mm to 6mm size grade and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing [but excluding the cost of reinforcement] taxes and royalty all complete, as per building specification and direction of E/I. |
| 8 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 9 | Providing designation 75B brickwork in C.M.[1:6] in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 10 | Providing R.C.C. M-200with nominal mix of [1:1.5:3] in beam, Chajja, of all types with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing [but excluding the cost of reinforcement] taxes and royalty all complete, as per building specification and direction of E/I. |
| 11 | providing Tor steel reinforcement of 8mm,10mm,12mm,& 16mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)8mm |
| 12 | 12-20MM |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Providing 12mm cement plaster [1:6] with clean coarse sand of F.M. 1.5 including cost of screening curing with all leads & lifts of water scaffolding, taxes & royalty all complete as per building specification & direction of E/I. |
| 17 | Providing 6mm cement plaster [1:4] in ceiling with clean coarse sand of F.M. 1.5 including cost of screening curing with all leads & lifts of water scaffolding, taxes & royalty all complete as per building specification & direction of E/I. |
| 18 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 19 | Providing Wall Putty on inside wall surface |
| 20 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 21 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 22 | Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 23 | Providing, hoisting and fixing above plinth level up to floor five level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 24 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter |
| 25 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansionCoupler- 110mm |
| 26 | Bend 87.5-100mm |
| 27 | Shoe 110mm |
| 28 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete.-110mm |
| 29 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.) |
| 30 | S/ F/F of Truss Roof |
| 31 | P/L paver block 60mm |
| 32 | Add Carriage of Materials Local Sand 3 KM |
| 33 | Sand Lead 21 KM |
| 34 | Stone Chips Lead 25 KM |
| 35 | Brick Lead 8 KM |
| 36 | ELECTRICAL WORKS -Wiring for light point/ fan point/exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch ,modular plate, suitable GI box and earthing the point with 1.5sq mm FR PVC insulated copper conductor single core cable etc as required. |
| 37 | Wiring for light/power plug with 2x 4 sq.mm FR PVC insulated, copper conductor ,single core cable in and surface/recessed PVC conduitalong with 1 No. 4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as requried . |
| 38 | Wiring for circuit / sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor , single core cable in surface/ recessed PVC coduit as required.2X1.5 sq mm +1 x 1.5sq mm earth wire. |
| 39 | 2X2.5 sq mm +1 x 2.5sq mm earth wire . |
| 40 | Suppling and fixing following moduler type switch / socket on the existing switch box / cover including connection etc. as reqd.5/6 amps switch |
| 41 | 5/6 amps socket |
| 42 | 15/16 AMPS, 3 PIN SOCKET OUTLET |
| 43 | Supplying and fixing 2 pin, 5 amps celling rose on existing junction box/ wooden block including connection etc. |
| 44 | S/F following way three pole and neutral, sheet, MCB distribution board, 415 volts on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) 4 way (4 + 12) double door, horizontal type |
| 45 | RECESS MOUNTING LED ROUND DOWN LIGHT 18/20 W |
| 46 | S/F/F 90/100 W LED STREET LIGHT |
| 47 | Good & Service Tax (GST) |
| 48 | Labour Cess Please Enable Macros to View BoQ information |