Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metre lead as per direction of Engineer - In - Charge. (DSR No. 15.26) |
| 3 | Demolishing mud phaska in terracing and disposal of material within 50 metres lead as per dirction of Engineer - In - Charge.(D.S.R No. 15.27) |
| 4 | Demolishing R.C.C.work manually by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - In - Charge.(D.S.R No.15.3) |
| 5 | Demolishing brick work manually by mechanical means including stacking of serviceable material and disposal of unserviceable material witihin 50 metres lead as per directon of Engineer - In - Charge.(DSR No. 15.7.4) |
| 6 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in charge. 1:3:6 or richer mix DSR 15.2.1 |
| 7 | Dismentaling doors, windows and clerestory window (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead as per direction of Engineer - In - Charge.(of Area 3 Sqmtr. And below (D.S.R No. 15.12.1) |
| 8 | Dismantling tile work in floors and roofs/wall laid or fix in cement mortar includingstacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm. (DSR 15.23.1) |
| 9 | Dismantling manually/by mechanical mean including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Enigneer - In - Charge. For Bituminous Road (DSR No.15.43.2) |
| 10 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 11 | Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 12 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in charge.1:4:8 or leaner mix |
| 13 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m. In All kind of Soil. (DSR 2.6.1-2.36) |
| 14 | Earth Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil (DSR 2.26.1) |
| 15 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. |
| 16 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, onsolidating each deposited layer by ramming and watering, lead up to 50 m and lift pto 1.5 m.(DSR 2.25) |
| 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) (DSR 4.1.10) |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) |
| 19 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). DSR 4.10 |
| 20 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.(DSR 4.13) |
| 21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.4.2 |
| 22 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level: Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2 ) |
| 23 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.(DSR 6.15) |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. (DSR 5.9.1 ) |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. (DSR 5.9.3 ) |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ) (DSR DSR 5.9.4) |
| 27 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers. (DSR 5.9.5 ) |
| 28 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and StrutsColumns DSR 5.9.6 |
| 29 | Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7). |
| 30 | Centering and shuttering including strutting, propping etc. and removal of form for : Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards. (DSR 5.9.13 ) |
| 31 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) (DSR 5.11.1) |
| 32 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of Concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 33 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of Concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level/cum Concrete of M25 grade with minimum cement content of 330 kg /cum (DSR 5.33.2.1) |
| 34 | Add for using extra cement in the items of design mix over and above the specified cement content therein. (DSR 5.35 ) |
| 35 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade fe500D or more (DSR 5.22.6) |
| 36 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position andbinding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22A.6) |
| 37 | Supplying and filling in plinth with choe sand under floors, including watering, ramming, consolidating and dressing complete.(DSR 2.27) |
| 38 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. (DSR 4.17) |
| 39 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). (DSR 22.3) |
| 40 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR 13.21 ) |
| 41 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR 8.5) |
| 42 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) Nondecorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.1) |
| 43 | 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws. (DSR 9.21.3) |
| 44 | Providing and fixing teak ply of approved shade on face of flush door shutters of green/kit/Duro make complete in all respect to the entire satisfaction of Engineer in charge. (N.S) |
| 45 | Providing and installation 6mm thick rubber floroing fixed with adhesive i/c welding of joints for sport use including skirting of approved make complete in all respect to the entire satisfaction of EIC.(N.S) |
| 46 | Providing and fixing 6mm th. Looking Mirror with Stainless steel studs complete in all respect to the entire satisfaction of engineer in charge.(N.S) |
| 47 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (DSR 10.25.2) |
| 48 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm (DSR 9.96.1 ) |
| 49 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm (DSR 9.96.2) |
| 50 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm (DSR 9.97.1 ) |
| 51 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm (DSR 9.97.3 ) |
| 52 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10mm (DSR 9.97.4 ) |
| 53 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm (DSR 9.100.1 ) |
| 54 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100mm (9.100.2) |
| 55 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper (DSR 9.101.1) |
| 56 | Providing and fixing aluminium casement stays ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. (DSR 9.102) |
| 57 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge. (DSR 9.119) |
| 58 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. DSR 9.120.1 |
| 59 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. DSR 10.28 |
| 60 | Providing & fixing glass panes toughened with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 6.0 mm thick glass panes |
| 61 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35mm thick shutters (DSR 9.27.1 ) |
| 62 | Providing and fixing glazed shutter for door and window using 4mm thick float glass paned including , for doors, windows and clerestory windows with hinges and necessary screws : 35mm thick (DSR 9.9.2.1 ) |
| 63 | Providing and fixing 2'-0\\" high Steel jaffery consisting of 16mm gauge M.S sheet strips welded with MS angle 40x40x6mm frame fixed in boundary wall with 9\\" long anchorage in cement concrete 1:2:4 block with sheet strip height 2'-0\\" and extra 3\\" gap shall be with top of wall after making dismantling of wall and repair after fixing of jafferycomplete in all respect as per drg & job to the entire satisfaction of the Engineer-in-Charge. (Only MS sheet strip area to be measured for payment) |
| 64 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) DSR 4.1.3 |
| 65 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm. (DSR 8.2.2.2) |
| 66 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.1 Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent (DSR 11.56.1) |
| 67 | Providing and fixing Ist quality ceramic glazed wall tiles of size 600mm x 300mm or more conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. DSR 11.36 |
| 68 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (DSR 11.41.2) |
| 69 | Providing and laying Vitrified Antiskid floor tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (Size 600 x 600mm) (N.S) |
| 70 | 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay: 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:With common burnt clay F.P.S.(non modular) brick tile of class designation 10 |
| 71 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (DSR 11.46.2) |
| 72 | Providing and fixing mirror polished Granite 15 - 17mm thick in 3\\" thick strips as per pattren on ramp or any where required laid over 20mm thick base cement mortar 1:4 with joints treated with white cement, mixed with matching pigments epoxy touch i/c rubbing, curing, moulding and polishing the edge to give high gloss finish etc. complete in all respects to the entire satisfaction of Engineer in Charge. NS |
| 73 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (DSR 11.48.2 ) |
| 74 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum ewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR 16.75 ) |
| 75 | Centering and shuttering including strutting, propping etc. and removal of form for ; Edges of slabs and breaks in floors and walls. (Under 20 cm wide) DSR 5.9.16.1 |
| 76 | Providing and fixing PCC kerbs of size 2’-0” x9” having 4” thickness at bottom and 3” thickness at top made of plain cement concrete 1:2:4 duly vibrated and compacted. The rate also includes the cost of filling and pointing of joints between kerbs with cement mortar 1:4 ( 1 cement : 4 coarse sand) complete in all respect to the entire satisfaction of the Engineer-In-Charge |
| 77 | Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand). Stone ware spout. (DSR 12.37.1 ) |
| 78 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (DSR 13.1.1). |
| 79 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) (DSR 13.2.1 ) |
| 80 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) DSR 13.16.1. |
| 81 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement: 3 fine sand) : Flush / Ruled/ Struck or weathered pointing. (DSR 13.31.1 ) |
| 82 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80 ) |
| 83 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm(DSR 13.45.1) |
| 84 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) ( DSR 13.46.1 ) |
| 85 | Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work/Pvc work (hard and soft wood) DSR 13.50.1 |
| 86 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work DSR 13.60.1 |
| 87 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work DSR 13.61.1 |
| 88 | Providing sprey P.U polish on wood work on ready mixed P.U sealer of Sirka/asian/Nerolec on new wood work complete in all respect to the entire satisfaction of engineer incharge (N.S) |
| 89 | Providing and fixing plain bend of required degree. 150 mm dia :Sand cast iron S&S as per IS - 1729 (DSR 17.39.1.1) |
| 90 | Providing and fixing 150mm dia PVC pipe of heavy duty including cost of sockets required length complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 91 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : (DSR 21.1.1.3) |
| 92 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3 ) |
| 93 | Providing and fixing clay brick tile cladding of approved shape and shade by the Engineer - in - Charge over 12mm thick cement mortar 1:3 complete in all respects including cost of centering and shuttering and to the entire satisfaction of Engineer - in - Charge. |
| 94 | Providing and fixing stainless steel gratting for 150mm dia rain water pipe complete in all respect to the entire satisfaction of engineer in charge |
| 95 | Supply and filling cinder in roof depressed area, including watering, ramming, consolidating and dressing complete in all respect to the entire satisfaction of Engineer in charge |
| 96 | Accoustic Doors:- Providing and fixing of accoustic double panneled doors with splayed/recessed joint in centre for entry by providing 12mm thick commercial ply on both side fixed on wooden frame of 2nd class hard wood bettens of size1½'' x 2'' having grid@ 2'-0'' C/C on both sides duly filled with providing and laying 50mm thick rock wool with 48kg density, packed with tissue paper to achieve NRC 0.7% (manufacturing test certificate is required at the time of billing ) and fixing of 4mm thick teak veneering with froove is to be fixed on both side of approved brand. The door shall have 2 Nos shutter on each side with folding arrangements and properly ecentrically tied with existing chowkhat during opening. The accoustical door shall be properly fixed with existing chowkhat with the help of 6 Nos SS hinges of size 5'' on both shutters and also hinges in center with sound sealing arrangements. The door shall have 2'-0'' size SS handles (4 nos each door) and 2'-0'' long SS tower bolts (2 nos each door) and (1 no sliding door bolt of size 300-450mm) complete fixed with help of nails. The door shall also includes the cost of PU polish including cost of filler and all hardware material of Stainless steel i.e locking arrangement, slidding bolts, towers bolts and handles complete in all respect to the entire satisfaction of Engineer-In-Charge. (N.S.) |
| 97 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4stone aggregate 10mm and down gauge) including finishing with cement mortar1:3 (1 cement: 3 fine sand) as per standard design :In 75x75mm deep chase (DSR 12.21.1) |
| 98 | Providing edge moulding to 18mm thick granite counters,vanities, steps etc i/c machine polsihing to edges to give high gloss finish etc complete as per design approved by EIC based on (DSR 8.3.2) |
| 99 | Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : 100x75x3.50mm |
| 100 | Credit of doors, windows, windows shutter complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 101 | Credit of bricks tiles complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 102 | Credit of Bricks tiles bats complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 103 | Credit of Earth (mud phaska in terracing) Complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 104 | Credit of steel complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 105 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side (DSR 21.2.1) |
| 106 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workabilitywithout impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M30 grade with minimum cement content of 350 kg /cum (DSR 5.33.1.2) |
| 107 | All works above plinth level upto floor V level: Concrete of M30 grade with minimum cement content of 350 kg /cum (DSR 5.33.2.1). |
| 108 | Electrical Work |
| 109 | Wiring for light point/ fan point/ exhaust fan point with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable in recessed heavy duty PVC conduit ISI marked with modular switch, modular plate, blanking plate if required, suitable size GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable. Iincluding GI Box, Concealed Light Box, Modular switch socket & 5/6A Switch single pole etc complete as required. Make of switch/plate: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). Make of Cable: Finolex/Polycab/Havells/KEI Group - C |
| 110 | Wiring for group controlled light point/ fan point/ exhaust fan point (without independent switch etc.) with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable in recessed heavy duty ISI marked PVC conduit with modular switch and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. complete as required. Make of switch/plate: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). Make of Cable: Finolex/Polycab/Havells/KEI Group - C |
| 111 | Wiring for twin light control point with 2x1.5 sq mm FRLS, PVC insulated copper conductor single core cable in recessed heavy duty pvc conduit,2 way modular switch,, modular plate, suitable size GI box and earthing the point with 1.5 sq mm FRLS, PVC insulated copper conductor cable etc as required.Make of switch/plate: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). Make of Cable: Finolex/Polycab/Havells/KEI |
| 112 | Wiring for circuit/ submain wiring along with earth wire with following sizes of FRLS, PVC insulated copper conductor, single core cable in surface/recessed heavy duty PVC conduit including cutting the wall and making good the same in case of recessed conduit as required. Make of cable: Finolex/Polycab/Havells/KEI Pipe Make of PVC pipe: Diplast, BEC,AKG. |
| 113 | 2 x 2.5 sq mm + 1 x 2.5 sq mm as earth wire |
| 114 | 2 x 4.0 sq mm + 1 x 4.0 sq mm as earth wire |
| 115 | Supplying and fixing of following size of heavy duty ISI marked PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Make of PVC pipe: Diplast, BEC,AKG. |
| 116 | Supplying and fixing suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16 A modular socket outlet and 6 pin 5/6A &15/16 A modular switch, connection etc. as required. Make: Hager,Legrand, Northwest Wipro, Norysis, Captree (Murano), Schneider. |
| 117 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ woodenblock including connection etc. as required. |
| 118 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 119 | MODULAR GI BOXESSupplying and fixing following sizes / modules, GI box along with Modular base & cover plate for modular switches in recess etc as required. Make: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). |
| 120 | 3 Module (100mm x75 mm) |
| 121 | 6 Module (200mm x 75mm) |
| 122 | 8 Module (125mm x125mm) |
| 123 | 12 Module ((200mmX150mm)) |
| 124 | Providing and fixing following rating MCCB 4 pole 415 Volt ( Thermal magnetic / microprocessor release without MS enclosure for Over load and short circuit protection, 35-55 KA Breaking capacity (Is=100% [Icu) with positive isolation. The overload & short circuit release shall be of Adjustable Type. The MCCB is to be installed in existing cubicle panel / angle iron board including drilling holes in cubicle panel / angle iron board, making connections with suitable rating of copper wire / copper strip etc. as required. The job includes the cost of spreaders terminal links etc. asrequired. 400 Amp 4 PoleMCCB(Microprocessor release). The MCCB should be of L&T/ Siemens/ Schneider/Legrand/ ABB/ Hager make only. |
| 125 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connectioN.S (M.R) but excluding modular plate etc. as required. Make: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). |
| 126 | 3 pin 5/6 amp switch outlet |
| 127 | 15/16 amps switch outlet |
| 128 | 3 pin 5/6 amp socket outlet |
| 129 | 15/16 amps socket outlet |
| 130 | Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc.as required.Make: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). |
| 131 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos 3 Pin 5/6Amp. Modular socket outlet and 2 Nos 5/6Amp modular switch, connections etc. as required. Make: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). |
| 132 | Supplying and fixing modular blanking plate on the exixting modular plate & switch box excluding modular plate as required .Make: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). |
| 133 | Supply & Laying of DWC pipe 50/63mm with hand bockey:-Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /Gemini.. The pipe should be laid below ground/road level by digging the ground upto75 cm less excavation or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work. |
| 134 | Supply & Laying of DWC pipe 90/76mm with hand bockey:-Supply and laying of 90/76 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /Gemini.. The pipe should be laid 3 feet below ground/road level by digging the ground upto 3 feet or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work. |
| 135 | Supply & Laying of DWC pipe 50/63mm with out hand bockey:-Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /Gemini. The pipe should be laid 75 cm below ground/road level by digging the ground or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work. |
| 136 | Supply & Laying of DWC pipe 90/76mm with out hand bockey:-Supply and laying of 90/76 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /Gemini.. The pipe should be laid 3 feet below ground/road level by digging the ground upto 3 feet or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work. |
| 137 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make: Finolex/Polycab/Havells/KEI |
| 138 | 2 x 1.5 sq.mm |
| 139 | 3x 1.5 sq. mm |
| 140 | 3x 2.5 sq. mm |
| 141 | 3x 4 sq. mm |
| 142 | 3x 6 sq. mm |
| 143 | Providing & fixing of 4C*2.5 Sqmm. Electrical Copper wire for B/w IDU & ODU Power supply with complete in all respect. Make: Havell, Finolex & Polycab. |
| 144 | Providing & fixing of 4C*4 Sqmm. Electrical Copper wire for B/w IDU & ODU Power supply with complete in all respect. Make: Havell, Finolex & Polycab. |
| 145 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole Make: Make: Seimens, Schneider, Legrand, L&T, Hager. |
| 146 | Supplying and fixing 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole Make: Seimens, Schneider, Legrand, L&T, Hager. |
| 147 | S/F TPN MCB Supply and Fixing following rating, four pole, 415 volts, MCB TPN with box complete with connections tensing and commissioning etc as required. Make: Seimens, Schneider, Legrand, L&T, Hager. The work shall be executed to the entire satisfaction of Engineer in charge. 63 Amps |
| 148 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door Make: Seimens, Schneider Acti 9., Legrand, L&T, Hager, |
| 149 | Providing and fixing 100 A 36 KA 4 POLE rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Make: ABB, Havells, Schneider, Legrand, L&T, Hager. |
| 150 | Providing and fixing 125 A 36 KA 4 POLE rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel, making connections, etc. as required. Make: ABB, Havells, Schneider, Legrand, L&T. |
| 151 | Providing and fixing circular/ hexagonal cast iron or MS sheet box for ceiling fan clamp of internal dia 140 mm, 73mm height top lid of 1.5 mm thick MS sheet with its top surface hacked for proper bonding, top lid shall be screwed in to the cast iron/ MS sheet box by mens of 3.3 mm dia round headed screws one lock at the corners. Clamp shall be made of 12 mm dia MS bar bent to shape as per standard drawing. |
| 152 | G.I. Earth pipe electrode with salt/ Charcoal: Supply and laying of earth electrode made out of ISI marked 'B' class G.I. pipe 4.5 Mtr. long 40 mm dia including accessories. GI pipe electrode shall be cut tapered at the bottom and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom. The earth electode shall be laid in ground after boring as per CPWD specificationscomplete in all respect and to the entire satification of the engineer-in-charge. |
| 153 | P/F 6 SWG GI earth wire: Providing & fixing earth connection from earth electrode with 6 SWG dia G.I. wire to pole, as required including nut, bolt washer and drillling hole etc to the entire satisfaction of Engineer-in-Charge. |
| 154 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 155 | Supplying and laying 25 mm X 5 mm G.l strip at 0.50 meter below ground as strip, earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm) |
| 156 | Supply and Erection of Three Phase ETP grade Copper Bus Bar |
| 157 | Supply and Erection of Three Phase ETP grade Copper Bus Bar with enclosure of rating 100 amp. to be fixed on wall/ in main incoming panel complete in all respects of make: Havells- IHBC020004 or equivalent in ABB/Schneider/Legrand.The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 158 | Supply and Erection of Three Phase ETP grade Copper Bus Bar with enclosure of rating 200 amp. to be fixed on wall/ in main incoming panel complete in all respects of make: Havells- IHBC020004 or equivalent in ABB/Schneider/Legrand.The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 159 | P/F of LED luminarie of size 2'x2' of 30-36 watt (595x595 mm) recess type including driver with minimum system efficacy of minimum 120 lm/W. THD <10%, PF > 0.95, Having coloured temperature 4000-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Havells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj alongwith connection, testing and commissioning erc. This job also includes all petty material required to be entire satisfaction of Engineer-in-charge. Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. |
| 160 | P/F of LED luminarie of size 2'x2' of 30-36 watt (595x595 mm) surface type including driver with minimum system efficacy of minimum 120 lm/W. THD <10%, PF > 0.95, Having coloured temperature 4000-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Havells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj alongwith connection, testing and commissioning erc. This job also includes all petty material required to be entire satisfaction of Engineer-in-charge. Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. |
| 161 | Supply & Erection of 1x18 watt retrofit LED tube rod with batten Supply & Erection of 1x18 watt retrofit LED tube rod with batten made of aluminium housing with PC diffuser Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should beHavells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj . The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 162 | Supply & Erection of 2x18 watt retrofit LED tube rod with batten Supply & Erection of 2x18 watt retrofit LED tube rod with batten made of aluminium housing with PC diffuser Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should be Havells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj . The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 163 | S/E of M.S. angle iron bracket of size40x40x6mm .The bracket should be painted with the coats of superior quality paint. The job includees all the material, labour including making holes in the bracket to fix the flood light fittings etc complete in all respect. The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 164 | Supply and erection of 14 GMS sheet frame of suitable size for erection of 12\\"/15\\"/18\\" sweep exhaust fan. The holder should be suitable for12\\"/15\\"/18\\" sweep exhaust fan shall be cut from the centre of the sheet and bedding 1/4\\"round collar with round cut and duly fixed with existing ventilator frame with suitable arrangement after removing the existing glass. The exhaust fan frame shall be painted on both side with superior quality paint after one coat of primer. The job includes the cost of M.S strips of 1\\"×1/4\\" and other petty material required to complete the job to the entire satisfaction of E.I.C |
| 165 | S/E of M.S. angle iron board covered with 14 GMS sheet fixed in to the nitch for mounting switchgear. The switches/ BDB's ELCB shall be provided with required no. of supporting member of M.S flat 25mm x 5mm to bring all the switchgear in one level including bonding the board switchgear etc. to the existing earth. The board shall be fabricated out of 40mm x 40mm x 5mm angle iron frame and shall be covered with a 14 GMS sheet duly welded for erection of switchgear items on it. The board shall be painted with two coat of approved shade of superior quality paint after one coat of primer. The rate includes carriage from factory to site, erection charges in the niche and other petty material required at site of work. |
| 166 | Making of haudi of 1.5'x1.5' size for drawing of underground cable etc constructed with bricks wall 4 ½\\" thick and plastered from the inner side with cement, sand, mixture 1:5. The RCC cover moulded in an angle frame of size 35mm x 35mm x 5mm should be provided above the Haudi which should rest on 40mm x 40mm x 5mm angle iron frame fixed on the upper portion of the Haudi. The cover should be provided with lifting arrangement. The rate includes all labour and material to complete the job with 1:4 CC mixture. |
| 167 | Supplying and fixing following sizes / modules, GI box along with Modular base & cover plate for modular switches in recess etc as required. Make: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). 16 MODULE |
| 168 | S / E of ceiling fans complete with aluminium blades, plastic canopies 2 Nos. double bal bearing, MS hanging rods, condenser, reels, clamps etc. The body of fan and blades should be white in colour. The job includes the cost of making necessary connections from the adjacent light point with 1.5sq.mm single core copper conductor cable. The sample of fans shall be got approved from the Engineer-in-charge of work before installation at site. The job also includes the cost of carriage, erection, testing, commissioning of fan, all labour and petty material required to complete the job to the entire satisfaction of the Engineer-in-Charge.[Size56\\" 1400mm sweep ceiling fan of Havells make Velocity White / Orient make Summer Breeze Crompton make Cool Breeze / Usha make Apollo Bajaj make Sabse. Tez only |
| 169 | Supply and Erection of Exhaust fan (heavy duty motor with copper wound metallic body) following size complete with motor, mettalic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation,epoxy powder coating along with mettalic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. Size 12\\" Sweep 900 RPM with louver of Havells make Turbo Force SP/ Orient make Industrial heavy duty / Crompton make HDEF EXHD 300- 6-1 / Bajaj make Supreme DLX only. |
| 170 | Supply,Installation, Testing and Commissionng of wall fan 400 mm (ISI mark) including cost of petty material required to complete the job in all respect. (Make Crompton/Havells / Armonard/ Bajaj) complete in all respect.There shall be free replacement at site for a period of five year from the date of delivery, Toll free number shall be provided by the supplier to the client Exhaust fan , wall fan etc. Complete in all respect, as required. |
| 171 | Providing & Fixing Cable Junction box of size 250x200x100mm complete in all respect. The job included fixing of Junction box on the wall with all petty material as required. The work shall be executed to the entire satisfaction of Engineer-in-Charge. Make: Sintex |
| 172 | Supply and laying of insulated 2 core x 10mm2 aluminium multi conductor twin core flat unarmoured cable to fixed on the suitable clamps and nuts /bolts etc make finolex/ lapp/ polycab/ havell's or its equivalent of ISI marked. The work shall be executed to the entire satisfaction of engineer-in-charge. |
| 173 | Supply & laying of ISI marked 3.5 core 120 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 3.5 core 120 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.3. The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 174 | Supply & laying of ISI marked 4 core 16 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 16 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.1 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 175 | Supply & laying of ISI marked 4 core 35 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 35 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.2 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 176 | Supply & laying of ISI marked 4 core 50mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 50 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.2 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 177 | Supply & laying of ISI marked 4 core 70mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 70 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.2 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 178 | Outdoor type M.S. Cubical Pedestal : S&E of Outdoor type BOTH SIDE OPEN ABLE M.S. Cubical Pedestal of size 1200mmx 900mm x350mm fabricated from 16 G.M.S. sheet welded on M.S. angle iron frame of size 50mmx 50mm x6mm with 4 Nos. legs of angle iron of same size each of length 600mm with M.S. sheet of size 100mmx100mmx6mm thick at the bottom of the legs. The front side of the pedestal should be openable with hiunged door provided with Godrej type locking arrangements. A 'U' type support made from M.S. sheet of 16 G having width 75mmx6mm be welded vertically in the inner side of the door to avoid entry of water. The door of the pedestal should be provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. M.S. sheet of 16 G thickness and 1200mm x 150mm size be fixed at the front to cover the entry of cables. Four No. supporting members each of size 50mmx6mm thick according to cubical size shall be welded for mounting switcher gear i.e. ICTPN,BBC, Timer and energy meter etc. The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. The legs of the pedestal shall be embedded in the 1:2:4 R C.C. mixture by digging 1½' deep as required. The letter 'M.C.C.' in 4\\" size shall be written on the front door of the Pedestal. The job also includes Supply & erection one No. wooden plank/ board of size 1'-6\\" x 1'-6\\" and 25mm thick suitable for fixing energy meter including cost of screws, nuts & bolts in cubical pedestal complete in all respects. The pedestal will be housed on RCC Foundation platform of size 900 mm deep (450 mm underground and 450 mm above ground x 910 mm long x 360 mm wide including sufficient number of entries for cable with DWC pipe The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 179 | Supply, Installation, Testing and Commissioning of double door type LT panel (loadbank 8way ) of suitable size, dust and vermin proof, fabricated out of 1.6mm thick CRCA sheet steel, power coated with 11 tank process, for better environment protect . MCCB panel board should be manufactured and supplied by ISO-9001 certified OEM of MCCB. The panel board should be suitable for floor or wall mounted and should be of robust constructions. Panel should have cable alleys on both sides for easy cable termination & digital metering module shall also be provided. Make of panel Havells CAT No: - IHLGF4000800 or its equivalent in ABB/Schneider/Legrand. The panel board should comprise of the followings.a) Copper Bus Bar of rating equal or higher than the incomer MCCB current rating.b) Incomer MCCB Rating 400A, 4Pole, 50kA, Ics= Icu= 100%(Makes: Havells, ABB/Schneider/Legrand/Hager)c) Outgoing MCCB, Rating 200A (2nos), 4Pole, 36kA,Ics= Icu= 100% (Makes: Havells, ABB/Schneider/Legrand/Hager) d) Outgoing MCCB, Rating 100A (6nos), 4Pole, 25kA,Ics= Icu= 50% (Makes: Havells, ABB/Schneider/Legrand/Hager) |
| 180 | Supply and erection of automatic street light panel of Havells/Legrand make or equivalent of ABB/ Siemens which should control automatic switching of light that can be repeated on daily basis, suitable to a load of 6KW of frame size with FRLS internal wiring and class H insulation. It should have following provisions: i) Incoming and outgoing terminal block with auto manual switch. ii) Incoming MCB TPN. iii) Contactor of suitable size with MCB SP. iv) Astronomaical Digital 24 hours timer. v) Outing MCB SP. vi) All the above equipment is housed in CRCA sheet enclosure with gasket for makng it water/ vermin proof, the detail product view showing internal arrangement of equipment is attached with estimate. The job includes cost of wo no. legs 3.5 feet long each made out of 50mm x 50mm x 5mm angle iron grouted in ground with cement concrete of ratio 1:2:4 and other petty required to complete the job to the entire satisfaction of EIC. |
| 181 | SITC of 01 No./13 Passenger lift 884Kgs/ 1mps speed / Travel 8Mtr. (approx)/G+1+2/3Stops/3Openings/Shaft Size required: 2500mmwxl900mmd/Car Size: AS PER IS STD/Clear Opening:900mmwx2000mmh/Pit-1700mm/Headroom4500mm/Center Openingdoors//V3F Microprocessor based Selective Collective Simplex control/ Car- SS Honeycomb Centre opening power operated car door in SS Honeycomb/ Centre opening power operated landing door in SS Honeycomb/ PVC flooring protection/ 1 hrs. Fire rates doors Automatic Rescue Device/ Infra- Red Screen Sensor/Auto Light and fan off / over load warning indicator with announcement/ SS handrail/ SS False ceiling in car/ Dot Matrix LED D & P Indicators in car and landings - Orange colour/ Push button- orange LED illumination/ 2 way intercom- press and speaker/ full car operating panel/ full loaded by pass/ floor Annunciator with music/ Sill Angle Sill Support/ Fireman's Switch/ battery operated alarm bell and emergency light/ minor builders work/ Scaffolding/ Pit leader/ Lift license/ Free Service for one year/ All std. Govt. features.The make of lift shall be Kone, Mitsubishi, Schindler or Johnson lifts only. |
| 182 | Supply and erection of 01 No./250 kgs dumb waiter lift/0.34 Mps speed/ travel 8 mtr. (aaprox)/ G+1/ 2 stop/2 opening/ shaft size required: 1500mmw x 1200mmd/ car size: 1000mW x 1000mm D x 1200mm H/ Clear opening: 100mm W x 1200mm H/ M S painted car body and doors/ collapsible landing door/PVC flooring/ control: External extended push buttons with/ without attet/\\" UP\\" & \\"Down\\" arrows in landings onlysteel cubicle for controller/ minor builders work/ scaffolding/ Free service. The make of lift shall be Kone, Mitsubishi, Schindler or Johnson lifts only. |
| 183 | Supply and erection of 8 way double door, IP-43 metal door, recess mounting, vertical type, 415 volt, VTPN MCB distribution board of sheet steel, dust protected, duly powder painted, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs ( but without MCBs and incomer) suitable for MCCB upto 160Amp. The job includes the cost of making connections, testing, commissioning, labour and other petty material etc. as required to complete the job to the entire satisfaction of EIC. Make: Schneider, Legrand, Acti9, Hager, Seimens. |
| 184 | S/I/T/C of Split Type AC- 2.0 -ton Cooling only with 24000 Btu/Hr cooling capacity. The AC Have 3.5 EER ratio (Inverter 3-star rating) with rotary sealed compressor operating on refringent R-410-A suitable for wall mounting remote control including piping / Electrical Wire between indoor & outdoor up to Three meter with sleeve in type insulation to the entire satisfaction of Engineer-in charge. Make: Daikin, Voltas, Carrier/ Hitachi. |
| 185 | Ductable Unit: S/I/T/C Duct able unit of Direct Expansion type AIR COOLED DUCTABLE UNITS of SCROLL semi hermetic single compressor suitable for R 410 A/R 407C refrigerant in each Unit. The Indoor Units shall be connected with Outdoor Units having suitable Coil surface area with Sub cooling circuit and Hydrophilic Blue Fins, Outdoor Fan motor. Indoor Unit shall have 3RD Coil, DIDW BLOWER with motor, Micro Processor based LCD Controller with Self Diagnosis function, Auto Start mode, Energy saving, Motor Protection device, Anti-recycle timer, Inbuilt temperature sensor and programmable controller. Micro processor control panel suitable for operation on 415 V, 3 phas , 50 Hz etc complete as required .The Refrigent Gas Should Be Factory Charged. Each unit shall comprise of separate Indoor and outdoor unit with standard packing of unit. Make: Daikin, Voltas, Carrier/ Hitachi.. 11 TR Capacity |
| 186 | Cassette Unit : S/I/T/C of Four–way Cassette Type AC with cooling, filtration, circulation and dehumidification. The unit shall have inbuilt drain pump for draining water. The AC Have 3.5 EER ratio (Inverter rating) with rotary sealed compressor operating on refrigerant R-410A/R32 suitable for wall mounting remote control. The entire satisfaction of Engineer-in-charge. Make: Daikin, Voltas, Carrier/ Hitachi. 2.5 TR Four-way Cassette Type. |
| 187 | 2.5 TR Four-way Cassette Type. |
| 188 | Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly insulated with 9/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. Make:Totaline,Maxflow,Rajco |
| 189 | 6.4 mm dia with 9mm thick nitrile rubberr insulation |
| 190 | 9.53 mm dia with 9mm thick nitrile rubber insulation |
| 191 | 12.07 mm dia with 9mm thick nitrile rubber insulation |
| 192 | 19.05 mm dia with 13mm thick nitrile rubber insulation |
| 193 | 22.2 mm dia with 13mm thick nitrile rubber insulation |
| 194 | DUCT INSULATION:Supply and fixing Thermal Insulation material shall be Nitrile Rubber Thermal conductivity of the insulation material shall not exceed 0.047 W/moK at an average temperature of 20°C. Density of the nitrile rubber shall be 140 – 180 Kg/m3. The material should withstand maximum surface temperature of +85°C and minimum surface temperature of -20°C. The material should confirm to Class A rating for surface spread of Flame in accordance to manufacturing standred.9mm |
| 195 | Ducting: Supply, installation, balancing and commissioning of Site fabricated GSS sheet metal rectangular ducting with supports as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following gauges (Galvanizing shall be with zinc nominal 120 gm/sqmtr):- |
| 196 | 24gThickness0.63mmsheet |
| 197 | 22gThickness0.80mmsheet |
| 198 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. |
| 199 | Supplying & fixing of powder coated extruded aluminium Supply/Return Air Grills with aluminium volume control dampers as per specifications. |
| 200 | Supplying & fixing of powder coated extruded aluminium Eye Boll Diffuser with volume control dampers complete as required. |
| 201 | SITC of cable tray (Punched Hole) of 300*50*1.2 mm size with hanger spot, Jointing etc. as per specification. |
| 202 | S/I/T/C of Voltage stabilizer 5 KVA for AC up to 2 Tr with MCB, TDR volt meter copper winding input range 180–250-volt single phase including cost of copper wire from stabilizer to A.C unit with M.S body of 22-gauge sheet powder coated). Make DEOL/Jewel/V-guard |
| 203 | Providing & Fixing PVC rigid drain pipe 25 mm (3/4\\") dia of Diplast/ finolex make of complete in all respects from indoor unit to disposal points as directed by EIC. |
| 204 | SITC of Electrical distribution Sub panel of size 1200*950*350 mm(H*W*D) for VRV ODU and AHUs etc. The Panel made from 2 mm thin CRCA sheet steel indoor type , fixed type, Floor/ Wall mounted, powder coated with siemen grey shed (RAL 7032) , Single front , Top/ Below cable entry, detechable gland plate having Aluminum busbar of 200 Amp. , Digital voltmeter and ammeter, current density 1 Amp/mm2 LED phase indicatior, base channels etc. • Incomer -1 nos. -\\"200 A 3 phase MCCB ,TMD Release , Standard extended rotary handle, Multifunction energy meter with POP , Next gen Pro LED indicator (Red, Yellow & Blue) etc.\\" • Outgoing-6 Nos -\\"Each have 100 Amp. MCCB, 3 phase preventer, 3 Contactor with NO/NC, with stdr. Colour wiring. ON/OFF indicator etc.\\" • Outgoing-16 Nos.-Each have 15 Amp. MCB DB, Single phase, etc. ( Make of panel: Tricolite,ECS, Ambit, International Switchgear, Amco, Kalyani Switchgear) having CPRI test certificate and follow ISO 9001-2008. Make of MCCBs,ACB, MCB, Contactors, Lamps, Capacitors: Schneider, ABB, Legrand, L&T, Siemens, Hager. |
| 205 | Supply & Erection of high power LED 180-200 Watt Flood Light luminaries:High-brightness White LEDs sources with high transmittance LENS on each LEDs with peanut lens with toughened glass, secondary lens optics, system lumen output of system luminous efficacy of ≥120 lm/W, 4000 K color temperature & CRI<70 value for ensuring good quality light output. Life of at least 50,000 hours & LED driver efficiency >95%, potted driver and driver should comply cispr-15 and EMI/EMC compliance, Power factor greater than 0.90, THD<15% & min 4KV internal surge protection and 10KV External surge protection with operating voltage range from 120-270 V for ensuring lifelong high performance of luminaire, having in built protection against short circuit, over voltage protection, the fixture is made of LM-6 Pressure die-cast aluminum with engraved company name & have IK05 & IP66 Class I protection with NABL Accredited LM-79 & LM-80 Report. The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. The luminary should not be over power derived. The fitting shall be mounted on the plate bracket on existing pole including making connection, testing & energizing complete in all respect to the entire satisfaction of Engineer-in-charge. The LED Street Light Fixture shall be installed on 7.5/9 mtr long pole. The luminary should be make Philips/ Crompton/ Havells/ Surya/ Wipro/ Bajaj.The detailed specification for supply of LED Street light luminaries is as under (with 02 years warranty). 1. Thermal Management system Good Thermal Management system Management of LED should be provided and LED must be Mounted on heat sink conductive Aluminum with suitable large area Surface by means of fins to disciple Heat to ambient air.2. Applicable standard The fixture should confirm to Application BIS/IES standard/ IESNA LM 20 |
| 206 | Supply of 10W Wall mounted LED bulk head ligh delivering minimum system lumen of 1000 lm and te luminaire shall be with system efficiency> 100lm/W Housing and Rim is pressure Die cast aluminium, IP65, IK 10 optics: Polycarbonate opal high transmissive Diffuser, Ambient temp 45degC. The Operating CCT shall be 4000/5700K with CRI of >80. The lumiaire shall be Bis registed with Electronic driver with input Voltage range of 140 to 265V, THD> 10% & PF>0.95, 50,000Hrs Luminaire Life with L70 Criteria. Shall have minimum surge protection of 2.5KV The LED Driver shall be easily availible in India for repair and service. The LED shall be SMD type. The luminaire shall be with following certification. LM79&LM80 issued by LED Manufacture along with Phote biological safety standard. It should have Electrical Class insulation Detailed specification, SLA and other information to be given in DNIT condition. preferred make list are attached as annexure. Rate includes the comprehensive warrantee of 2 years from the commissioning. The fitting should be make Philips/ Crompton/ Havells/ Surya/ Wipro/ Bajaj.Work must be complete to the entire satisfaction of engineer in charge |
| 207 | S/I/T/C18- 20W LED Downlighter, MINIMUM 100 Lumens/watt, THD <10%, Pf > 0.95, CCCV driver, protection IP 20, and CCT 4000-5700K, Surge protection 4kV, Operating Voltage Range - 150V – 270Volts.Wattage - 18-20 watt MAKE- philips ,Wipro,Trilux,Osram,Havells, Jaquar complete in all respect.Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. The work shall be executed to the entire satisfaction of Engineer-in-charge |
| 208 | S/I/T/C OF 8-12 Watt LED Downlighter, made of extruded aluminium housing and high power LED as alight source wih clear diffuser and seperate electronic driver with minimum 95 Lumens/watt, THD <10%, Pf > 0.95, protection IP 20, and CCT 4000-5700K, Surge protection 4kV, Operating Voltage Range - 150V – 270Volts.MAKE- philips ,Wipro,Trilux,Osram,Havells, JAGUAR complete in all respect.Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. The work shall be executed to the entire satisfaction of Engineer-in-charge |
| 209 | Supply,Installation, Testing and Commissionng LED cove Strip light 5mtr with 4.8W/mtr and 2 amps complete with LED driver of make PHILIPS/osram/havells/wipro trilux/opple, Jaguar ., (2 years Warranty). complete in all respect.The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 210 | SI/T/C of bi-directional CT meter alongwith 03 Nos. of CTs 200/5 Amp including meter box of required size for placement of meter and CTs of make- L&T, Secure or approved make by electricty department. The job includes testing of the meter from lab including paying the testing charges taken by electricity department. |
| 211 | Fabrication & erection of steel shutters for electrical niches as per following specifications FRAME: The shutter of suitable dimensions for electrical nitch shall be made out of 16 G.M.S.sheet. The shutter frame shall be 1-1/2”x1-1/2”x1-1/2” channel frame 4 Nos. ‘L’ type holdfasts for fixing the same on the wall. The size of the shutter frame should be suitable for 2Nos. door panels/single panel depending upon the size of nitchesDOOR PANEL: The door panel shall have support in U-Shape formation made from 16G.M.S. sheet with 4”x3/4”M.S. channel duly spot welded to give additional strength. The door panel shall be fixed with frame with the help of concealed M.S. hinges of suitable size having good strength. The door panel shall be provided with a bolting arrangement either of Godrej type or such type so as to interlock the door panel with frame. The handle shall be of superior quality and nickel plated to facilitate its opening. The door panel must have as arrangement to provide a pad lock. FINISHING: The frame & the door panel should be given anti-rust, anti-grease and phosphate treatment with 3 in 1 paste and then spray painted with two coats of paint of superior quality. The shutter should be earthed properly with the existing earth with No.8SWG wire after erasing the paint from the body of the Shutter. The rate includes cost of all labor and material reqd. to complete the job to the satisfaction of the Engineer-in-charge. |
| 212 | Fire Alarm Panel (Compact): Supplying, installation, testing and commissioning of UL 864 10th edition UL Listed and FM approved Analog addressable 4 Loop Fire Alarm Control Panel having the total panel capacity of 504 devices. The panel shall be able to give pin point location of all Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 10000 events. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 2”x4-3/4” Size VGA monochromoe LCD display and having maximum 320 (8 x 40) Characters in the display with optional 24 Zones LED indicators. The panel shall have a built in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries of up to 33AH capacity. The Panel shall have the capacity of connecting additional 31 panels or Network terminals using network card, with redundancy in the network. The panel shall have the capacity of connecting maximum 16 Remote terminals /16 remote displays or combined by using 2 X RS 485 Card. Approved Makes :Cerberus Pro by Siemens/ Ansul / Gamewell |
| 213 | Smoke Detectors: Supplying, installation, testing and commissioning of UL268 6th and 7th edition compliance and FM approved Intelligent Addressable Photoelectric Smoke detector with advanced technology and false alarm resistance complete with standard base, facility to mount in different comprehensive environment, Tri-color detector-status LED with 360 ° view, microprocessor circuitry with error check; detector self- diagnostics, and supervision programs, Sensitivity range of 1.08 - 2.72% / ft obs, Superior EMI and RFI immunity, RoHS compliant. Detector shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature in detector shall consider Isolator base in place of standard base OR separate Isolator before and after every detector to comply the same without any extra cost. Approved Makes :Cerberus Pro by Siemens/ Ansul / Gamewell/ Bosch. |
| 214 | Heat Detectors: Supplying, installation, testing and commissioning of UL268 6th and 7th edition compliance and FM approved Intelligent Addressable multi-criteria detector (optical and thermal sensors) complete with standard base, facility to mount in different comprehensive environment, Tri-color detector-status LED with 360 ° view, microprocessor circuitry with error check; detector self-diagnostics and supervision programs,Rate-of-Rise Detection: 15°F / min. (8.3°C / min.) - Fixed: 135°F (57°C) , Field programmable as rate-of-rise or fixed temperature, Polarity insensitive, Superior EMI and RFI immunity, RoHS compliant. Detector shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature in detector shall consider Isolator base in place of standard base OR separate Isolator before and after every detector to comply the same without any extra cost. Approved Makes :Cerberus Pro by Siemens/ Ansul / Gamewell/ Bosch. |
| 215 | Duct Detector: Supply, installations, testing and commissioning of UL268 6th and 7th edition compliance and FM approved Intelligent Addressable Duct detector with 10ft sampling pipe (optical and thermal sensors) complete with standard base, facility to mount in different comprehensive environment, Tri-color detector-status LED with 360 ° view, microprocessor circuitry with error check; detector self-diagnostics and supervision programs,Rate-of-Rise Detection: 15°F / min. (8.3°C / min.) - Fixed: 135°F (57°C) , Field programmable as rate-of-rise or fixed temperature, Polarity insensitive, Superior EMI and RFI immunity, RoHS compliant. Detector shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature in detector shall consider Isolator base in place of standard base OR separate Isolator before and after every detector to comply the same without any extra cost. Approved Makes :Cerberus Pro by Siemens/ Ansul / Gamewell/ Bosch. |
| 216 | Manual Call Point: Supply, installations, testing and commissioning of UL listed and FM approved Intelligent addressable Class X type (Style 7), Manual Pull Station Double Action, Shock and Vibration Resistant, with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal,Yellow for Faulty and RED for activation), T-45 Key Reset lockset for easy maintenance, Operating Temp and RH: 0-49degC and <=95%. MCP shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every MCP to comply the same without any extra cost. Approved Makes :Cerberus Pro by Siemens/ Ansul / Gamewell/ Bosch. |
| 217 | Hooter/ Strobe/ Jack: Supply, installations, testing and commissioning of UL Listed Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 75cd flashintg at 1 Hz for visual indication. Approved Makes :Cerberus Pro by Siemens/ Ansul / Gamewell/ Bosch. |
| 218 | Speaker: Supplying, installation, testing & commissioning of 1.5/3/6W metal boxceiling/wall speakers complete as required. Approved Makes :Bosch/Harman/Audac/Apart. |
| 219 | Exit Board: Supply, installations, testing and commissioning of fire exit sign board illuminated made from etched sheet with LED illumination and all electrical accessories included battery and battery charge etc. on ceiling/ wall mounted (with logo & exist arrow).Make:-Glowline/ HHE/ Ravel/ Honeywell. |
| 220 | Amplifier: Supplying, installation, testing and commissioning of a versatile mixer amplifier designed for various applications. It operates at 220-230V AC, with power options of 60W, 120W, or 240W. Featuring a wide frequency response of 80 Hz to 18 kHz, it ensures clear audio quality with minimal distortion (<1% @ 1 kHz). Bass and treble controls allow for up to ±8 dB adjustments. The amplifier includes AUX and insert inputs, with RCA and screw terminal connectors for flexibility. It delivers loudspeaker output at 100V or 4 ohms, with maximum power ratings of 360W at 100V and 31V at 4 ohms. Compact at 100mm x 430mm x 290mm (2U), it can be mounted standalone or in a 19\\" rack, suitable for temperatures ranging from -5 ºC to +45 ºC. Approved Makes :Bosch/Harman/Audac/Apart. |
| 221 | Speaker Cable: Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the exiting surface/recessed steel conduit of following pairs, cores and sizes including connections and interconnections etc. Speaker Cable Two Pair, 2 Core, 1,5 sq.mm |
| 222 | Armoured cable: Supplying & laying of 2x1.5 sq. mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 223 | Fire Exinguisher ABC Type : Supply and installation of ABC Type Stored Pressure Fire Exinguisher with capacity of 6 Kg with wall mount brocket Make: Safeex or Safepro. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 224 | Fire Exinguisher CO2 Type: Supply and installation of CO2 Type Fire Exinguisher with 1 meter hose and PVC Horn with capacity of4.5 Kg with wall mount bracket Make: Safeex or Safepro. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 225 | Supply/Erection of 6 KVA/4.8 KW online, pure sine wave UPS with enclosure suitable for 1 phase AC input and 1 phase AC output with battery backup half hour (30 Mins) with (min. VAH= 4992 VAH). The UPS should be of Microprocessor control double conversion, PWM/ IGBT based invertor with LCD display for monitoring of its status and provided with open battery Rack. The job includes the cost of carriage, erection, installation, commissioning and testing charges including rack, connecting and other petty material required to complete the job. The UPS should be of Emerson-Virtiv / APC / Fuji Electic-Consul Neowatt/Zebronics / Microtek make only. |
| 226 | The UPS should have following specification. |
| 227 | Manual by-pass facility. |
| 228 | Switching device shall be IGBT. |
| 229 | Input: 110-300V AC @ 50% Load, 176-300V AC @ 100% load |
| 230 | Output: 208/220/230/240 VAC (+ - 1%) |
| 231 | Operating Temp. -00C to 400 (Non - Condensing) |
| 232 | Operating humidity: 20-90% RH |
| 233 | Total harmonics distortion at output: ≦ 3 % THD (Linear Load) ; and ≦ 5 % THD (Non-linear Load). |
| 234 | Efficiency: AC Mode efficiency (minimum 92%) |
| 235 | Power Factor Handling Capacity 0.8 and above |
| 236 | Over load: AC Mode/Battery Mode: 105-110% for 10 min, 110-130% for 1 min, >130% 2 sec |
| 237 | Protections: following protection shall be provided in UPS. |
| 238 | Over voltage, short circuit and overload at UPS output terminal. |
| 239 | Under voltage at battery terminal |
| 240 | Audible Alarm operators on fault conditions |
| 241 | Indicators and meters |
| 242 | Mains presence. |
| 243 | Battery charging and discharging |
| 244 | Digital meter shall be provided for monitoring the following parameters in UPS (not applicable for rack mounting) |
| 245 | Output AC voltage, current and frequency. |
| 246 | Phone Jack: Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. |
| 247 | Telephone Handset: Supplying, installation, testing & commissioning of fire fighter telephone handsetcomplete as required. |
| 248 | Supply and erection of 400 Amp. 415Volt.4 pole ON Load Change over switch with MS enclosure of following ratings installed in existing switch board/ TL Panel with nuts & bolts of requisite size after making holes etc. The job includes cost of making inter connection with suitable rating copper wire / copper strip with dowels, lugs & thimbles duly crimped, bonding to existing earth and carriage, testing & commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. Make L&T/ Siemens/ Schneider/ Legrand/ ABB/ Hager/Havells/HPL make only. |
| 249 | Supply/Erection/Testing & Commissioning of 40 Watt LED Post Top Lantern of 4000-6000K made up of Die cast Aluminium base & spun Aluminium top fitted with LED PT Module. The power LED's are mounted directly on inbuilt extruded Aluminium Heat Sinks. It should have UV stabilized injection molded P.C. Opal/Frosted Diffuser which is provided for Glare free Lighting with high Visual comfort. The fitting should be suitable for mounting on pole having dia 60-75 mm, system efficacy more than 80 lumen/ watt, power factor ≥ 0.9, IP 65 protection and of make K-Lite / Twinkle (LUXMAX-PT-161A) / Bajaj only. The job should be carried out upto the entire satisfaction of Engineer-in-charge. Warranty: The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. |
| 250 | Supply and Erection of 4 Mtrs long Decorative Galvanised mild steel Pole Including Foundation.Design, Supply & Erection of decorative Galvanised mild steel Pole having total length of 4.0 mtr with MS base plate of size 250x250x12 mm with 114mm dia and 4mm thickness of the bottom portion and 75mm dia and 3mm thickness of top portion with Cast Aluminium embellishments at the middle of the pole. The pole should be provided with a cut out at the bottom for making necessary connection including a 25 Amp MCB of good quality. The pole should be painted with PU paint.025 color black as per Engineer direction. The cut out should have lockable flush door for orotection of connections. The make of the pole should be Bajaj, Schreder, Twinkle, K-Lite, Keslec or its equivalent. The work shall be executed to the entire satisfaction of Engineer-in-Charge. The rates are inclusive of costing of foundation for erection of pole. The dimensions are with Production tolerance ± 3%. |
| 251 | Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plantconforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, copper/G.I plate earthing(AC/DC side seperately), mounted on Aluminium/GI structure of suitable strength and all bolts, nuts, fasners shall be of stainless steel/hot dipped Galvanised with following components complete as required:-a) Solar Photovoltaic Module of capacity 545 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2, IS-16170/IEC 61853, IEC-61701. Solar Photovoltaic Module conversion efficiency shall not be less than 20.9%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.Rated power of solar PV module shall have maximum tolerance upto +/- 3% and minimum fill factor of 75% to be used. Performance ratio (PR) should be show on Minimum of 75% at the time of initial commissioning etc. PV panel must have RFID , shall able to withstand windspeed as per standard and all other specifications mentioned in conditions of DNIT.b) Power Conditioning Unit (PCU) of 150-450 V/200-1000V (as per requirement) DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, conferming to IEC-62109, IEC/IS 61683,IEC-62116/60068, IEC-60255-27,IEC61000-2,3,5. Output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. It should run on MPPT, PCU/Inverter shall have overload capacity of minimum 10%, micro processor/ DSP controller, idling current at no load must not exceed 2% of rated current.c) Mounting Structure: Mounting structure to be Hot dip Galvnised iron/M.S. structure of suitable strength and all bolts, nuts, fastners shall be of stainless steel/ hot dip galvnised and as per BIS standard. Rate includes the required work to be done at flat surface/ slant surface and height of mounting structure may increase as per site requirement. Also rate includes the stairs, pathways any other material required for smooth running of solar plant. |
| 252 | d) Data Monitoring System: There should be an provision of online monitoring in the system. The system should include all the provision for making the units IOT/COMPATIBLE for connection with the SCADA (should be GSM Sim base/wifi based) building Sector-17. e) Others: Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc.as required. Lightning and surge voltage protection (both ac and dc), Islanding protection.Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. f) Document Submission:Agency to submit the detailed survey report (Tilt angle, no of module, capacity, no of aray, positions etc) of optimised solar generation to engineer in charge for approval. Also, preparation and submission of drawings/documents/Data sheet/BOM (Civil/electrical/mechanical), shadow analysis reports and quality assurance plan cover in the scope of agency and all the product must be approved from Engineer in charge before despatch to site. g)Warrantee: There shall be warrantee of 25 years for solar panel and 10 years for all other material including PCU unit from date of commissioni h) Annual maintenance contract (AMC): Regular operation and maintenance of the SPV power plant for a period of ten years after commissioning along with replacement of any items as and whwn necessary as all the items are comprehensively warranted for 10 years under the operation and maintenance contract. Plant must be in running conditions all the time and penalty clause and detailed conditions are mentioned in DNIT conditions. Rate includes all the devices/ work required to make system operational till energy meter/ compact substation. Detail specifications of all items are given in DNIT conditions. Prefred makes are mentioned as annexure. |
| 253 | P/F of heavy duty Air Circulator Wall fans of size 450 mm, RPM 1400± 5%, power input 120-130 watt, 220-240 volt, 50Hz single phase, 3 speed of Make Crompton/ Havells/ Phillips/Bajaj/Khaitan. |
| 254 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making bearing good the damage, Carriage Charges connection testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. [Size 15inches (380mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver ofHavells (Turbo Force SP) / Crompton (EXHD380-6. (1) / Orient (Industrial Heavy duty)/ Usha (Turbo HDEF)/ Bajaj (Supreme Plus) make only. |
| 255 | S/E of 4 nos. Sand buckets of 10 Ltr. Capacity each made out of 24 Gauge G.I. Sheet. The buckets with sand shall be erected on suitable size of angle iron stand fabricated out of 1 1/4\\" x 1 1/4\\" x 1/8\\" angle iron having hooks for hanging the buckets in two rows. The job includes the cost of painting with two coats of red paint of superior quality after one coat of primer on buckets and stand to complete the job upto the entire satisfaction of the Engineer in charge. |
| 256 | S/E of medium size first aid box made of 16 gauge MS sheet of size 14\\"x7\\"x5\\" with 6 wound dressings, 3 burn dressing, 13 gms absorbent cotton wool, one dressing scissors, one bottle of spirit of sal volatile, 1 tube of burn ointment (Burnol) tablets of aspiring, 1 no. artificial respirator. |
| 257 | Supply and erection of shock treatment chart written in Hindi and English and local language duly framed in wood frame with glass complete as required as per Indian Electricity Act (Safety rules). |
| 258 | Supply and Erection of M.S. Sheet danger notice plate at least 2mm thick required to complete the job in all respect to the entire satisfaction of the Engineer in Charge. |
| 259 | SI/T/C of full crystal chandelier (round shape) with in-built LED lights, 1000mm in dia with three colour variant, with metal to ped golden PVD finished. |
| 260 | Supply and Installation of wall mounted bracket having provision of installing one no. of post top decorative fittings. The total length of the bracket should be minimum 750 mm and height of the bracket should be minimum 485 mm. Make of the bracket should be LuxMax-BKT211 or equivalent of Bajaj, Keslec, Surya, Havells. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 261 | 11kV Outdoor Package Sub-Station shall consist of following: |
| 262 | A. General 1 Type BIOSCO2 MV System Nominal Voltage 11 kV3 Transformer Power Rating 250 KVA4 LV System & Panel 433 V5 Reference Standard IEC 62271-2026 Degree of Protection MV & LV Compartment: IP 54 Transformer Compartment: IP 34B. Enclosure Construction 1 Enclosure Material & thickness 2mm thick painted GI2 Type of Ventilation Natural3 Temperature Class K-104 Base type 4mm thick Hot Dip Galvanized CRCA5 Door & Locking arrangement Access for MV & LV Compartments with Double door arrangement & Padlocking arrangement. Access to Transformer compartment side covers is through MV/LV Compartment or through doors6 Enclosure Paint shade RAL 1001- Cream7 Earth Bus-bar 50x6 sq.mm. (GI )C. Type Test as per IEC-62271-202 1 Test of Internal Arc 21ka/1sec2 Test of Ingress Protection of MV & LV Compartment IP-543 Test of Ingress protection of Transformer Compartment IP-344 Test of Temperature rise Oil Transformer-Oil/winding – 40/45 degree C5 Test of mechanical stress \\"After impact IK-10(Energy of 20 joules):IP-3X Left transformer, and IP4X for the parts LT & MT, The Doors remain functional after the impacts on the hinge plates on the handle and the\\"6 \\"Test of rated peak and the rated short time withstand current of the earthing conductor\\" 12.5kA for 1 sec - 31.5kA peak- single phase |
| 263 | A. HT Switchgear 11 kV, 630A, 21kA/3 sec, 1 Way, indoor, Non-Extensible SF-6 insulated RMU, comprising 1 No. fixed Manual Vacuum Circuit Breaker in stainless steel tank- with Operating handle, Voltage presence indicator (VPIS) & manometer integrated earthing switch. Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sq.mm Al. unarmoured XLPE Cable 1No• Protection CT– 15-30/1A, 2.5VA, 5P10. 3No.• Mechanical position indicator. Switch ON/OFF/EARTHED. 1Set• Voltage presence Indication 1Set• Manometer 1No.• Operating Handle 1No.• RMU shall be capable for cable termination of 1C x 300 sq.mm unarmoured Al XLPE Cable. |
| 264 | B. Transformer • 250 KVA, 11/0.433 kV, Dyn11, 3 Phase,50hz, Mineral oil filled hermetically sealed transformer with copper winding, +5% to -5%@2.5% with off Load tap changer having class-A insulation & temperature rise in oil/winding of 40/45 deg. C [Max.] along with standard fittings & accessories as per IS:1180 1No• Losses shall be as per 1180 Energy Efficiency Level-1(2021) Amendment no.-4 • Total losses at 50% Load : 980 Watts (max.) Total losses at 100% Load : 2930 Watts (max.) • Impedance: %Z – 4.5% (IS Tol.) • Oil/Winding temperature indicator with alarm & trip contacts 1No. |
| 265 | C. LT Panel • 433V LT Indoor panel with 500 Amps Aluminium Bus bars (100% for Phase and 50% for Neutral), Fabrication using 1.5/2mm CRCA sheet steel, Ingress protection IP2X/4X, complete with internal wiring consisting of following. Incomer • 400A,4P,433V,36 kA fixed Manual type Microprocessor based release MCCB with (O/L,S/C + E/F protection) 1No. • Resin Cast CT- 400/5A,10VA, Accuracy CL-1.0 3No. • RYB, ON-OFF-TRIP Indication 1No. • Digital Ammeter & Voltmeter built in selector switch CL-1 1No. • APFC Panel • 75 kVAr MPP Standard duty type @440 V 1No. |
| 266 | D. Outdoor Enclosure Outdoor type enclosure having construction of Galvanised Sheet Steel. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP34 degree of protection for Transformer compartment. The enclosure exterior shall be Powder coated (Color -RAL-1001-Cream). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. 1Set |
| 267 | E. Interconnection & Earthing Interconnection between HT switchgear & Transformer using 1Cx3Rx95Sq.mm XLPE Al Single core cable & Interconnection between Transformers to LT switchgear using Aluminium bus bars. Internal earthing connections including Transformer Neutral by using 50x6 mm GI Strips. 1Set |
| 268 | Supply and laying of XLPE HT power cable, working voltage 11 KV, 3 core x70sq.mm, loose in pipe or surface (Havells/ Finolex/Polycab Make). |
| 269 | Supplying and making indoor cable end termination with heat shrinkable joining kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.50/70mm2 |
| 270 | Supplying and making outdoor cable end termination with heat shrinkable jointingkit complete with all accessories including lugs suitable for following size of 3 core,XLPE aluminium conductor cable of 11 kV grade as required 50/70mm2 |
| 271 | S/E of 4 nos. Sand buckets of 10 Ltr. Capacity each made out of 24 Gauge G.I. Sheet. The buckets with sand shall be erected on suitable size of angle iron stand fabricated out of 1 1/4\\" x 1 1/4\\" x 1/8\\" angle iron having hooks for hanging the buckets in two rows. The job includes the cost of painting with two coats of red paint of superior quality after one coat of primer on buckets and stand to complete the job upto the entire satisfaction of the Engineer in charge. |
| 272 | S/E of medium size first aid box made of 16 gauge MS sheet of size 14\\"x7\\"x5\\" with 6 wound dressings, 3 burn dressing, 13 gms absorbent cotton wool, one dressing scissors, one bottle of spirit of sal volatile, 1 tube of burn ointment (Burnol) tablets of aspiring, 1 no. artificial respirator. |
| 273 | Supply and erection of shock treatment chart written in Hindi and English and local language duly framed in wood frame with glass complete as required as per Indian Electricity Act (Safety rules). |
| 274 | S/E of rubber mat of size 6'x3'x12xmm thick (ISI mark) wide of superior quality and of approved make as approved by the Engineer in charge to be laid on floor in HT room in front of panels and transformers. |
| 275 | Supply and Erection of M.S. Sheet danger notice plate at least 2mm thick required to complete the job in all respect to the entire satisfaction of the Engineer in Charge. |
| 276 | Supply and Installation of ABC Type Stored Pressure Fire Extinguisher With Capacity of 6 Kg with wall mount bracket Make Atasi or Safepro or Equivalent ISI Marked |
| 277 | Supply and Installation of CO2 Type Fire Extinguisher with 1 meter hose and PVC Horn With Capacity of 4.5 Kg with wall mount bracket Make Atasi or Safepro or Equivalent ISI Marked |
| 278 | Supply and erection of two coarse structure made on two no. of 10 mtr Long steel tubular pole with base plate (165mm ) including cost of G.O switch with pipe, bari and handle, D.O fuse. Lighting arrester. 11kv fues unit including all petty materials and all mettalic parts etc complete in all respect. |
| 279 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 280 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground asstrip earth electrode, including connection/ terminating with nut, bolt, spring, washeretc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nutbolt & spring washer spaced at 50mm) |
| 281 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 282 | Supply, Installation, Testing & Commissioning of cubical type dust and vermin proof metering panel, free standing floor mounting made of 14 Gauge M.S. Sheet with channel for base frame. The panel shall have space to accimodate required (as desired by EIC) ratio CT & PT dry type unit and bidirectional trivector meter. It should have MS angle/ flat where ever required.. The panel shall have the provision of the incoming and out going 11 KV cable and bonding to the existing earth with suitable size of copper flat. The panel shall be painted with 2 coats of approved shade of paint after one coat of primer. The job includes cost of supply and erection of 100/5A CTs, having burden 10VA accuracy class 0.5 & cast resin potential transformer ratio 11kV/110V, 100VA, accuracy class 0.5 & bidirectional Trivector 3phase meter suitable to monitor the parameters of electricity consumption as per the specifications of Chandigarh Electrcity Department(CED) of approved make i.e. L&T/ Secure/ Saraf/ Vishal/ Zenith only. The meter is to be got tested from the M&P sub division laboratory of the CED at the stake of contractor. The meter is to be installed in the compartment including supply & erection of 11 KV test terminal block for connecting secondary connection of terminal block for connecting secondary LED connection of 11 KV CT/PT unit & Trivector meter as per site requirement. Both CT & PT strictly confirming to relevant IS specifications for 3 phase 4 wiring system. The job includes labour, testing fee, taxes and duties etc. The job includes erection of three phase 11 KV electronic energy meter with suitable size copper wire in the CT/PT panel complete with suitable size of wooden plank etc. The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 283 | Total of Items procured through tender (A) |
| 284 | Recovery Items (B) |
| 285 | Less the cost of old ceiling fan |
| 286 | Less the cost of old exhaust fan |
| 287 | Less the cost of old fitting 2'x2' of 36 watt |
| 288 | Less the cost of Old MS Box |
| 289 | Less the cost of Old Copper wire |
| 290 | Less the cost of old DB including MCCBs |
| 291 | Less the cost of old pole |
| 292 | Less the cost of Old MS Shutter |
| 293 | Les the cost of old wall fan |
| 294 | Less Cost of Old AC |
| 295 | Total (B) |
| 296 | Gross Total of Items to be procured by through tender (A-B) |
| 297 | Electrical external Service Connection for security amount |
| 298 | Provision for Public health work |
| 299 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required |
| 300 | E.W.C. pan with ISI marked white solid plastic seat and lid |
| 301 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore. |
| 302 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. |
| 303 | Providing and fixing white virtrous china ware star white colour under counter wash hand basin of size 56X43 cm hind ware make model no 10049 or any equivalent make parry ware etc. as per instruction of EIC including the cost of wiking make cp 32 mm waste, chair typoe adjustable brackets, jaguar 167B/ nova make central hole mixer including the cost of cutting granite for WHB and making hole in granite for fixing mixer, plugs, screws, white cemnt complete in all respects. |
| 304 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore |
| 305 | Providing and fixing uplasticised PVC connection pipe with brass unions |
| 306 | 30 cm length |
| 307 | 15 mm nominal bore |
| 308 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms 15 mm nominal bore |
| 309 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 310 | Granite of any colour and shade |
| 311 | Area of slab over 0.50 sqm |
| 312 | Providing and fixing in position 32 mm i/d CP Bottle trap for wash basin complete in all respects. |
| 313 | Providing and fixing soil, waste and vent pipes |
| 314 | 100 mm dia. |
| 315 | Sand cast iron S&S pipe as per IS: 1729. |
| 316 | 75 mm diameter : |
| 317 | Sand cast iron S&S pipe as per IS: 1729. |
| 318 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 319 | 100 mm |
| 320 | Sand cast iron S&S as per IS - 1729 |
| 321 | 75 mm dia |
| 322 | Sand cast iron S&S as per IS - 1729 |
| 323 | Providing and fixing plain bend of required degree. |
| 324 | 100 mm |
| 325 | Sand cast iron S&S as per IS - 1729 |
| 326 | 75 mm |
| 327 | Sand cast iron S&S as per IS -1729 |
| 328 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 329 | 100x100x100 mm |
| 330 | Sand cast iron S&S as per IS - 1729 |
| 331 | 75x75x75 mm |
| 332 | Sand cast iron S&S as per IS - 1729 |
| 333 | Providing and fixing collar |
| 334 | 100 mm |
| 335 | Sand cast iron S&S as per IS - 1729 |
| 336 | 75 mm |
| 337 | Sand cast iron S&S as per IS - 1729 |
| 338 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors |
| 339 | 100 mm inlet and 75 mm outlet |
| 340 | Sand cast iron S&S as per IS - 3989 |
| 341 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. |
| 342 | 15 mm dia. nominal bore |
| 343 | 20 mm dia. nominal bore |
| 344 | 25 mm dia. nominal bore |
| 345 | Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately) |
| 346 | Providing & fixing Gun metal ferrule 25 mm including the cost of threding, taping excavation earth and refilling the same after connection complete in all respects |
| 347 | 25 mm |
| 348 | Cutting holes upto 30x30 cm in walls including making good the same With common burnt clay F.P.S. (non modular) bricks |
| 349 | Making chases upto 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc |
| 350 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) |
| 351 | 20mm nominal bore |
| 352 | Providing and fixing brass stop cock of approved quality 20 mm nominal bore. |
| 353 | Providing and fixing gun metal non- return valve of approved quality (screwed end) |
| 354 | 25 mm nominal bore |
| 355 | Horizontal |
| 356 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank2000Ltr (10000 Nos.)5000Ltr (10000 Nos) |
| 357 | Providing and fixing PVC waste pipe 32 mm make up to floor trap isi mareked complete in all respects. |
| 358 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:4 (1 cement : 4 coarse sand) (1.656+8.11) = 9.77 MH |
| 359 | 12 mm cement plaster finished with a floating coat of neat cement of mix |
| 360 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 361 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete |
| 362 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).MH Less |
| 363 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m . All kinds of soil |
| 364 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 365 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete |
| 366 | 200 mm diameter |
| 367 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design |
| 368 | 200 mm diameter S.W. pipe |
| 369 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:5:10 as per DSR 4.1.10 |
| 370 | Floor |
| 371 | (CC 1:2:4)(Floor) (Block)(Benching) |
| 372 | Providing and fixing square-mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design |
| 373 | 100x100 mm size P type |
| 374 | With Sewer bricks conforming to IS : 4885 |
| 375 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design |
| 376 | Inside dimensions 600x900 mm and 45 cm deep for pipe line with one or two inlets |
| 377 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 378 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete |
| 379 | Paiting GI pipes and fiting with synthetice enamel white point over a ready mixed priming coat, both of approved quality for new work. |
| 380 | Providing and fixing in position best indian make ISI marked ball cock 25 mm with brass road PVC ball complete in all respects. |
| 381 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) |
| 382 | 15 mm nominal bore |
| 383 | 20 mm nominal bore |
| 384 | 25 mm nominal bore |
| 385 | Providing and fixing GI tank nipple AVR/ SVM make complete in all respects |
| 386 | 20 mm nominal bore |
| 387 | 25 mm nominal bore |
| 388 | Providing and fixing water meter cover 1'-6\\"X1'-0\\" with frame made out of MS sheet 18 gauge, frame from angle 30 mmX30mmX5mm with locking arragement, painting complete in all respects. |
| 389 | Providing DRIP SEAL joints to sand cast iron/ centrifugally cast (spun) iron pipes and fitting of diameter |
| 390 | 100 mm |
| 391 | 75 mm |
| 392 | providing and fixing PTMT liquid soap container including liquid complete as per item no 17.71 |
| 393 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 394 | Providing and fixing 8mm dia C.P./S.S.jet with flexible tube up to 1 mtr long complete as per DSR |
| 395 | Providing and fixing PTMT towel ring traper olded shape 225 complete as per DSR |
| 396 | Providing and fixing laminated Sun board of different size indicating information complete as per DSR |
| 397 | 12\\"X8\\" |
| 398 | Providing and fixing Exhust fan of 12\\" make Bajaj,Hawell,crompton complete as per EIC. |
| 399 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2\\" BSP thread and shapes. Weighing not less than 60 gms |
| 400 | Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. |
| 401 | 15 mm nominal bore, 80mm long. 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms |
| 402 | Providing and fixing PTMT grating of approved quality and colour |
| 403 | Circular type. |
| 404 | 100 mm nominal dia |
| 405 | Providing & fixing of mono block pump set 2 HP Single Phase 220 Volt 1400 RPM Make Crompton/ Kirlosker.complete in all respect. |
| 406 | Providing & fixing extension nipple for tap and angle cock complete in all respects 15 mm dia. |
| 407 | Providing & fixing of Manholes cover with frame complete in all respects. |
| 408 | Providing and fixing kitchen sink s.s. isi marked complete as per eic. |
| 409 | Storm water drainage network |
| 410 | Extra cutting through metalled road and their foundation including sorting screening and stacking at the site. Complete in all respects |
| 411 | 450 mm dia RCC pipe |
| 412 | 2.81 Earth work in excavation by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.MANHOLES (1.52X0.91)RG300 mm dia R.C.C. pipe450 mm dia R.C.C. pipe |
| 413 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering – All work upto plinth level4.1.10 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) (C&D)MH (1.52X0.91)RGFloor |
| 414 | 19.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete |
| 415 | 300 mm dia R.C.C. pipe |
| 416 | 450 mm dia R.C.C. pipe |
| 417 | 6.1 Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand)MH (1.52X0.91)RGBACK WALLWING WALL |
| 418 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering – All work upto plinth level4.1.4 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) (C&D)Manholes (Internal Floor)Manholes (benching)Floor |
| 419 | 12 mm cement plaster finished with a floating coat of neat cement of mix1:4 (1 cement : 4 fine sand)MH 10X2 (1.52X0.91)RGBackwallWing wall (4x2)Benching plaster |
| 420 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platformMH (1.52X0.91)Side of ManholeOpening |
| 421 | Reinforcement for R.C.C work including straightening, cutting, bending, placing in position all complete |
| 422 | Thermo-Mechanically Treated bars |
| 423 | MANHOLE |
| 424 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)MANHOLE (1.52X0.91)Deduction of manhole cover (-) |
| 425 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm × 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30×20×15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design |
| 426 | Providing & fixing of Manholes cover with frame complete in all respects. |
| 427 | Providing & fixing of road gully cover with frame complete in all respects. |
| 428 | Supplying and filling in plinth with Jamuna/local fine sand under floors including watering, ramming consolidating and dressing complete (C&D) |
| 429 | 450 mm dia RCC pipe |
| 430 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete |
| 431 | 300mm to 450mm |
| 432 | 450mm to 600mm |
| 433 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 434 | Carriage of Materials by mech. Transport including loading unloading and stacking upto 5 km |
| 435 | Installing, and commisioning of fire fighting system |
| 436 | Supplying, Laying, testing and commissioning of Kirloskar or equivalent reputed make pump DB 40/16 in back pull out design having 65mm suction, 40mm delivery, CI casting, bronze impeller and C-40 shaft with gland packed arrangement coupled on common base plate to Kirlosker/ABB (at our option) Make 5.5 KW/7.5 HP ~ 2900 RPM TEFC Sq. cage induction motor suitable through suitable flexible coupling. The pump set suitable for following duty points. Total Head : 35 Mtr. Flow/Discharge : 27 Cum/Hrs (450 LPM). |
| 437 | Providing and fixing automatic control panel required to operate main fire pump, Jocky Pump & Terrace pump auto system complete in all respects as per satisfaction of EIC Make :- Power System / L & T |
| 438 | Supplying and Laying copper flexible cable of 1.1 KV grade of following size on from pannel to moto etc., as required make : Gloster/Havells/polycab. |
| 439 | 4 x 16 mm² (for terrace pump) |
| 440 | 1.5mm x 2 core (for terrace pump with pressure switch) |
| 441 | Providing and applying one coat of 4mm thick ‘PYPKOTE’ or ‘COATEK’ anti rust pipe protection including approved primer of 2 coats as per manufacturer specification and lap of 25 mm to make an impermeable layer on M.S.F. complete including surface preparation : 100 mm dia |
| 442 | Supplying, Laying, Testing and Commissioning of C class heavy duty MS pipe for Rising Mains conforming to IS 1239 / 3589 complete with all fittings and accessories like elbows, tees, flanges, tapers, reducers, nuts, bolts, gaskets and washers including cutting, welding etc., providing cement concrete blocks as supports, anti corrosive treatment with coal tar / asphalt tape 4 mm thick as per IS 10221 and laying the pipe so that the top of the pipe is at a depth of 1 Meter below ground level complete as required of following sizes (NB) but excluding excavation (External Work) make : Jindal/TATA |
| 443 | 80 mm dia |
| 444 | 100 mm dia |
| 445 | 150 mm dia |
| 446 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 447 | Supplying installation testing and commissioning of dual plate type Non return valve of following sizes complete with bolts, nuts, washer, rubber gasket etc. as required. Make : Zoloto/Kartar/L&T (NSI) |
| 448 | 80 mm dia |
| 449 | 100 mm dia |
| 450 | 150 mm dia |
| 451 | Supplying, fixing, testing and commissioning of Butterfly valves of PN 1.0 rating conforming to IS:13095 of following sizes with nitride seat and stainless steel stem with lever/gear operation and cast iron body in powder coated finish for firefighting application, complete as required. Make : Zoloto/Kartar/L&T (NSI) |
| 452 | 80 mm dia |
| 453 | 100 mm dia |
| 454 | 150 mm dia |
| 455 | Supplying, Installation, Testing and Commissioning of Air vessel 100mm external dia, 8mm thick and 1.5 mt. long with air release valve, drain valve as per IS:4738/1969, (for 2 No. wet risers). Complete in all respect as per satisfaction of EIC. |
| 456 | Supplying, Installation, Testing and Commissioning of Pressure switches suitable for operation of fire hydrant system for working pressure of 10.0 kg/cm² including electrical control wiring with suitable rating PVC insulated and sheathed armored copper conductor control cable upto control panel, connections etc. as required complete to the entire satisfaction of EIC. Make: HONEYWELL / DWYER / DANFOSS / POTTER / System Sensor |
| 457 | Supplying, Installation, Testing & Commissioning of pressure gauge suitable for operation with fire hydrant system for working pressure of 10.0Kg/cm² i/c connection etc. as required complete to the entire satisfaction of EIC. Make: H-GURU / EBIG / WAREE |
| 458 | Supplying and fixing 2 way Fire brigade connection (FBC) of CI body with 2 No. stainless steel inlet couplings complete with cap and chain as required. For 100mm dia M.S. Pipe connection conforming to IS:904 as required complete to the entire satisfaction of EIC. |
| 459 | Supplying and fixing of Hose cabinet of size 600mm × 300mm × 250mm made of 2mm thick MS sheet with 6mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 Nos. 15 mtr. Long Hose pipe, 1 No. branch pipe, mounted on wall OR raised platform & duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant, as required. |
| 460 | Supplying and fixing First-Aid Hose Reel spray painted in Post office Red, conforming to IS:884 with upto date amendments, complete with the following as required complete to the entire satisfaction of EIC consisting of following : 30 mtr. Long 20mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS:12585 ; 20 mm (nominal internal) dia gun metal globe valve & nozzle ; Drum and brackets for fixing the equipments on wall ; Connections from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe |
| 461 | Supplying and fixing 100mm dia Gun metal branch pipe with 20mm (nominal internal diameter) size Gun Metal nozzle conforming to IS:903, suitable for instantaneous connection to interconnect hose pipe coupling as required. |
| 462 | Supplying and fixing 100mm dia, 30 mtr. Long RRL hose pipe with 63mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS:636 (type-A) as required complete to the entire satisfaction of EIC. Make: CRC / NEWAGE / PADIANI / JYOTI / SAFEX |
| 463 | Supplying & fixing 4.5 kg Carbon Dioxide (CO₂) portable fire extinguisher ISI marked under IS:2878 fully charged having cylinder body ISI marked under IS:15683 safety valve ISI marked under IS:3224 with safety clip siphon tube, discharged bend & horn complete with MS brackets for wall mounting etc., as required complete to the entire satisfaction of EIC. Make: Safex / Agni / Atasi |
| 464 | Supplying & fixing of ABC type fire extinguisher 4 kg capacity ISI marked fitted with screw down type high pressure control valve conforming to IS:15683 under IS:2878 fully charged having cylinder body ISI marked under IS:15683 with 1 Mtr. long wire braided high pressure discharge hose & electricity non conducting horn manufactured conforming to IS:2878 complete with initial charge, wall mounted bracket/screws etc., as required Make: Safex. |
| 465 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI:12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 466 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 467 | Photo Illumincent glow sign boards of suitable size as required complete to the entire satisfaction of EIC. |
| 468 | Providing and fixing of Gun metal valve with C.I. Wheel of 100 mm dia of approved make complete in all respect with entire satisfaction of EIC |
| 469 | Providing and fixing of G.I. pipe Union of size 100 mm dia complete in all respect with entire satisfaction of EIC |
| 470 | Providing and fixing of Gun metal Gate valve with C.I. wheel of 50mm dia of approved make complete in all respect with entire satisfaction of EIC |
| 471 | Providing and fixing of Ball Cock 50mm dia complete in all respect with entire satisfaction of EIC |
| 472 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 473 | Brick work with common clay F.P.S (non modular) bricks of class designation 75 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand) |
| 474 | 12 mm cement plaster finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 coarse sand) complete in all respect |
| 475 | Supplying, Installation, Testing and Commissioning of Manual Call point (MCP), as required complete to the entire satisfaction of EIC. Make: AGNI STAR/ AGNI DEVICE (NSI) |
| 476 | Supplying, Installation, Testing and Commissioning of hooter/sounder for use with fire Alarm to alert security system as required complete to the entire satisfaction of EIC. Make: AGNI STAR/ AGNI DEVICE (NSI) |
| 477 | Providing and fixing, testing & commissioning of manually operated fire alarm panel having capacity 220 Volts ACI 30 Volts 8 zone made out of CRC sheet having 18 gauge and is properly pretreated before being powder coated dust proof complete in all respect as per specification attached Make Agni/Atasi. Make: AGNI STAR/ AGNI DEVICE (NSI) |
| 478 | Providing, fixing, testing commissioning of smoke detector having capacity, complete in all respect of make Agni/Atasi |
| 479 | 2 wire photoelectric smoke alarm |
| 480 | 2 wire photoelectric smoke alarm with remote LED output |
| 481 | 2 wire photoelectric smoke and heat alarm |
| 482 | 2 wire photoelectric smoke and heat alarm with remote LED output |
| 483 | 4 wire photoelectric smoke alarm (24 VDC) |
| 484 | Provision for enhancement of electricity connected load charges. Enhancement of Electricity load, complete in all respects. |
| 485 | Provision for Horticulture Work |
| 486 | Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly by breaking clods, rough dressing, flooding with water, uprooting fresh grass growths, after 10 to 15 days and then grassing for planting new grass (selection no. 1), including disposal of all rubbish with leads and lifts. (dsr. 23.12). |
| 487 | Providing and planting of different types of ornamental plants in cement pots (20”) well grown decorative plants i.e. Ficus black, Raphis palm etc (Ht. 3-4’) to the entire satisfaction of Engineer-in-Charge. |
| 488 | P & P of Golden Cypress (Well grown bushy plant with ht. 4’-5’). |
| 489 | P & P Juniperous Green (Well grown bushy plant with ht. 4’-5’). |
| 490 | P & P of Golden Bottle Brush Topiary (5-6 ft. with 8 to 10 well developed balls). |
| 491 | P & P of plumeria alba (ht. 7-8’ in gunny bags). |
| 492 | P & P of different types of ground covers like Hamelia dwarf, Orthophytum, Lantana, Ophiopogon grass, Tazy grass, Golden Duranta, Wudelia trilobata etc. All plants should be well developed. |
| 493 | P & P of different varieties of decorative flowering shrubs like: Chandni Variegated, Hibiscus variegated, Tecoma capensis, Tecoma goni choni, Chandni dwarf variegated, Hamelia Patens, Nium Indica, Thivetia peruviana, Bougainvillea (Different colors), Trulia compacta, Golden bottle brush, Eunymus etc. All plants should be well developed and bushy with ht. 3’-4’. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail