Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m. In All kind of Soil. |
| 2 | Earth Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, onsolidating each deposited layer by ramming and watering, lead up to 50 m and lift pto 1.5 m. (DSR 2.25) |
| 4 | CARRIAGE OFEarth By Mechanical Transport including loading,unloading and stacking for 5 Km Lead (DSR 1.1.2) |
| 5 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand)mixed with water proofing compound in recommended proportions.(iii) Finishing top with stone ggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone. (DSR 22.1.1) |
| 6 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :Using rough kota stone. (DSR 22.2.1) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) (DSR 4.1.10) |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) |
| 9 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). (DSR 4.10) |
| 10 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. (DSR 4.13) |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) |
| 12 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) |
| 13 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (DSR 6.15) |
| 14 | Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level.Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.8) |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. (DSR 5.9.1) |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2) |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ) (DSR 5.9.4) |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers. (DSR 5.9.5) |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts. (DSR 5.9.6) |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases. (DSR 5.9.7) |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for : Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards. (DSR 5.9.13) |
| 23 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) (DSR 5.11.1) |
| 24 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of Concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum. (DSR 5.33.1.1) |
| 25 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of Concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in designmix shall be payable separately.In case the cement content in design mix is more than 110% of the specifiedminimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level/cum Concrete of M25 grade with minimum cement content of 330 kg /cum (DSR 5.33.2.1) |
| 26 | Add for using extra cement in the items of design mix over and above the specified cement content therein. (DSR 5.35) |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars (DSR 5.22.6) |
| 28 | Supplying and filling in plinth with choe sand under floors, including watering, ramming, consolidating and dressing complete. (DSR 2.27) |
| 29 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. (DSR 4.17) |
| 30 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (DSR 22.5) |
| 31 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR 13.21) |
| 32 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR 8.5) |
| 33 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) Nondecorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.1) |
| 34 | 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws. (DSR 9.21.3) |
| 35 | Providing and fixing teak ply of approved shade on face of flush door shutters of green/kit/Duro make complete in all respect to the entire satisfaction of Engineer in charge. (N.S.) |
| 36 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR 10.1) |
| 37 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. (DSR 10.25.1) |
| 38 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (DSR 10.25.2) |
| 39 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm (DSR 9.96.1) |
| 40 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm (DSR 9.96.2) |
| 41 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm (DSR 9.97.1) |
| 42 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm (DSR 9.97.2) |
| 43 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm (DSR 9.97.3) |
| 44 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :150x10 mm (DSR 9.97.4) |
| 45 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125MM (DSR 9.100.1) |
| 46 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100MM (DSR 9.100.2) |
| 47 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. SINGLE RUBBER STOPPER (DSR 9.101.1) |
| 48 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge. (DSR 9.119) |
| 49 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing.30 mm thick plain PVC door shutters (DSR 9.120.1) |
| 50 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR 10.28) |
| 51 | Providing and fixing 2mm thick polycarbonate sheet fixing on the existing railing. The rate also includes to seal the joints with the help of aluminium profile rubber gasket. The sheet will be fixed with the help of aluminium flat and self drilling screws complete in all respects and to the entire satisfaction of Engieer-in-Charge. (N.S.) |
| 52 | Providing & fixing glass panes toughened with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 6.0MM THICK GLASS PANES. (N.S.) |
| 53 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) |
| 54 | Providing and fixing glazed shutter for door and window using 4mm thick float glass paned including , for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters (DSR 9.9.2.1) |
| 55 | Fixing M.S. Jaffery of 2'-3\\" height made of M.S. Sheet on existing boundary wall including cost of centering and shuttering by making holes in brick work and filling CC 1:2:4 block of size 0'9\\"x0'9\\"x0'9\\"complete in all respects and to the entire satisfaction of Engineer- in - Charge. (N.S.) |
| 56 | roviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) (DSR 4.1.3) |
| 57 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade.Area of slab over 0.50 sqm. (DSR 8.2.2.2) |
| 58 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25MM THICK (DSR 11.26.1) |
| 59 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR 11.27) |
| 60 | Providing and installation 6mm thick rubber floroing fixed with adhesive i/c welding of joints for sport use including skirting of approved make complete in all respect to the entire satisfaction of EIC. |
| 61 | Providing and fixing 6mm th. Looking Mirror with Stainless steel studs complete in all respect to the entire satisfaction of engineer in charge. (N.S.) |
| 62 | Providing and fixing Ist quality ceramic glazed wall tiles of size 600mm x 300mm or more conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR 11.36) |
| 63 | Providing and laying vitrified floor tiles of sizes 600 x 600mm or more (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41.2) |
| 64 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% andconforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size 600x 600 mm. (DSR 11.41A.3.1) |
| 65 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR 11.39) |
| 66 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chippingdiamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 600 x 1200 mm (DSR 11.41A.1.3) |
| 67 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement. (DSR 11.20.1) |
| 68 | Providing and fixing mirror polished Granite 15 - 17mm thick in 3\\" thick strips as per pattren on ramp or any where required laid over 20mm thick base cement mortar 1:4 with joints treated with white cement, mixed with matching pigments epoxy touch i/c rubbing, curing, moulding and polishing the edge to give high gloss finish etc. complete in all respects to the entire satisfaction of Engineer in Charge. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm. (DSR 11.41A.3.1) |
| 69 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (DSR 11.48.2) |
| 70 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum ewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/lesscement used as per design mix is payable/ recoverable separately). (DSR 16.75) |
| 71 | Centering and shuttering including strutting, propping etc. and removal of form for :Edges of slabs and breaks in floors and walls. Under 20 cm wide. (DSR 5.9.16.1) |
| 72 | Applying stamping finish to the top surface of freshly laid plain/reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the Engineer-in-Charge. The process shall include the following:-• The concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. The approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of thefresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. The approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the whole surface to be stamped is completed within the time while concrete is in plastic stage ofsetting.• After stamping, the curing shall be done as per manufactures specifications. After initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per the requirement. The surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface.• The construction joints shall be provided by groove cutting of size 4mm x 20mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (PU) Polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying Polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (Cost of concrete for flooring is not included in this item which shall be paid separately.) (DSR 26.83) |
| 73 | Providing and fixing PCC kerbs of size 2’-0” x9” having 4” thickness at bottom and 3” thickness at top made of plain cement concrete 1:2:4 duly vibrated and compacted. The rate also includes the cost of filling and pointing of joints between kerbs with cement mortar 1:4 ( 1 cement : 4 coarse sand) complete in all respect to the entire satisfaction of the Engineer-In-Charge. (N.S.) |
| 74 | Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand). Stone ware spout. (DSR 12.37.1) |
| 75 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (DSR 13.1.1) |
| 76 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand). (DSR 13.2.1) |
| 77 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) |
| 78 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement: 3 fine sand) :Flush / Ruled/ Struck or weathered pointing. (DSR 13.31.1) |
| 79 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80) |
| 80 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm. (N.S.) |
| 81 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). (DSR 13.46.1) |
| 82 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work. (DSR 13.61.1) |
| 83 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work. (DSR 13.60.1) |
| 84 | Providing and fixing plain bend of required degree. 150 mm dia :Sand cast iron S&S as per IS - 1729. (DSR 17.39.1.1) |
| 85 | Providing and fixing for 150mm dia rain water pipe complete in all respect to the entire satisfaction of engineer in charge. (N.S.) |
| 86 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) :For fixed portion and chaukhats. Polyester powder coated aluminium (minimum thickness ofpolyester powder coating 50 micron) (DSR 21.1.1.3) |
| 87 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3) |
| 88 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (DSR 22.7.1) |
| 89 | Extra for Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge and approved by Engineer-in-charge to required slope and treating as directed and specified by the Engineer-in-Charge. (N.S.) |
| 90 | Providing and fixing clay brick tile cladding of approved shape and shade by the Engineer - in - Charge over 12mm thick cement mortar 1:3 complete in all respects including cost of centering and shuttering and to the entire satisfaction of Engineer - in - Charge. (N.S.) |
| 91 | Providing and fixing of lay-grid false ceiling consisting of 15mm thick ceiling tiles Armstrong / Dexune or equivalent as per approved sample of size 2' x 2' lay-in-modular grid / suspension system (hot dipped galvanized steel) of standard T - Saction having its flanges face powder coated colour white suspended from ceiling and secured with clips and G.I. etc with following details.a) Main runner shall be T-Shaped section with single rotary stitching of size 24mm x 36mm and 3600mm long.b) Cross runners shall be T-Shaped double rotary stitching of size 24mm x 26mm and 1200mm long.Cross runner T-Section of 24mm x 26mm and 600mm long. The frame work comprises of main gunners spaced at 1200mm centre to centre shall be securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. The hangers (G.I. wire of 4mm dia) to be fixed by meas of roof plug, level adjuster and screws etc. Finish fittings 1200mm long cross tees (with double stitching) to be interlocked between main runners at 600mm centre to form 1200mm x 600mm modules. Cut cross tees longer that 600mm to be supported independently to form 1200 x 600mm modules. The complete work shall include the cost of all material and labour and lead and fit complete and to the entire satisfaction of Engineer - in - Charge. (N.S.) |
| 92 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board (DSR 12.45.3) |
| 93 | Providing & fixing glass of specified colour of make Saint Gobain/ ASAHI/TATA , fixed with Silicon sealent and with necessary hardware (like screws,studs etc.) if required over existing ply board base .The glass must be properly finished from edges , machine grinded & polished .The groove between glass to glass joint shall be finished with silicon sealant all complete as per direction of Engineer-in-Charge: 6 mm thick Lacquered glass. (N.S.) |
| 94 | WOODEN GROOVED ACOUSTICAL SLATS:- Providing and fixing wood Based HDF panels with lineal perforations of approved make as approved by Engineeer-in-Charge at all heights including scaffolding. The panels shall be Non FR grade with melamine laminate panels 2440mm x 128mm x18mm with 2mm slats at 15 mm pitch, Toungue and Groove edges for seamless mounting. The back of the panels fixed wtih acoustical fleece for Sound Absorption. Panel is to be fixed on Dexune framework with screw fixed horizontal or vertical to wall at every 600mm with centre & edge bracket in tongue & groove system on framework. The cavity of framework should be inserted with rock wool with 48 kg density and 25mm thickness and alongwith all accessories complete in all respect and to the entire satisfaction of Engineer in charge. |
| 95 | Providing and fixing 'Acoustical Wall Panels’ of make Armstrong( Optra), Anutone( Subtex NRC),Dexune (CERES ) with square edges made of fibre glass substrate 25mm thick and wrapped on front and all sides except rear face with an acoustically transparent and fire-resistant fabric in all colours and shades of sizes 600x600 mm to 600x1200mm or other required sizeproviding a minimum sound absorption level of 0.90 Noise reduction coefficient. Accoustical wall panels are fixed to existing ply, board or other base with approved adhesives (SR 998) all Complete as per direction of Engineer-in-charge. |
| 96 | ACCOUSTIC DOORS:- Providing and fixing of accoustic double panneled doors with splayed/recessed joint in center for entry by providing 12mm thick commercial ply on outer side and 9mm thick commercial ply on inner side fixed on wooden frame of 2nd class hard wood battens of size 1½”x2\\" having grid @ 2'-0\\"c/c on both sides duly filled with 50mm thick rock wool with 48 kg density completely packed and fixing of 3mm thick teak veneering with groove is to be fixed on inner side and 1mm thick laminated decorative sheet on exposed sides with approved adhesive. The door shall have 2no's shutter on each side with folding arrangements and properly eccentrically tied with existing chowkhat during opening. The accoustical door shall be properly fixed with existing chowkhat with the help of 4no's SS hinges of size 5\\" on both shutters and also hinges in center with sound sealing arrangements. The door shall have 2'-0\\" size SS round handles and 2'-0\\" long SS tower bolts complete fixed with help of nails, The door shall also includes the cost of PU polish including cost of filler and all hardware material of Stainless steel i.e. locking arrangemnt, sliding bolts, tower bolts and handles complete in all respect to the entire satsfaction of Engineer-in charge. |
| 97 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete (DSr : 21.10) |
| 98 | Providing and fixing wooden paneling with 9mm waterproof ply (Duro/ greenlam/century/merino) fixed to existing grid of metal frame or laying over wooden/ply battons complete in all respect to the entire satisfaction of Engineer-in-Charge. |
| 99 | Zebra Blinds:- Providing and fixing roller blinds of approved make (Win Tree, Vista), shade and colour as approved by Engineer in charge having. The blinds shall be alternate opaque and translucent mesh venetien blinds including fittings for exceptional light control operational by spring loaded resin. ?Mounted aluminum rail of detachble fascia. Both side beautiful covered by pvc or resin part fixed in aluminium rail. Cap should be used to cover screw used for fixing clutch. Mounting brackets must have cushioning to reduce noise during operation. Mounting brackets must have provision of wall as ceiling installation. This bidirectional blinds shall be operational by assistance of polyester cord. This polyester cord should be molded inside pvc beads of 4.5mm outer dia. Mounting part made up of MS zinc coated of minimum thickness of 2mm molded in pvc. idle pin made of zinc plated MS of 9mm outer dia surrounded by bearing balls to supports blinds at other end. This bidirectional blind shall operational by assisame structure and having PU handle arm. The desk let assembly shall be filp-up type and shall be made up of extension tube of 1.6+/-0.02cm dia x 0.02+/-0.016cm thick M.S.E.R.W. tube PLPB desk let top shall be fixed. The polyurethane foam shall be moulded with deinsity =45.0=/-8.0kg/m3 and hardness = 20=/-2 complete in all respect to entire satisfaction of Engineer-in-Charge. |
| 100 | PART B ELECTRICAL WORK |
| 101 | Wiring for light point/ fan point/ exhaust fan point with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable in recessed heavy duty PVC conduit ISI marked with modular switch, modular plate, blanking plate if required, suitable size GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable. Iincluding GI Box, Concealed Light Box, Modular switch socket & 5/6A Switch single pole etc complete as required. Make of switch/plate: Legrand , Hager, Norysis, Captree, Schneider. Make of Cable: Finolex/Polycab/Havells/KEI Group - C |
| 102 | Wiring for group controlled light point/ fan point/ exhaust fan point (without independent switch etc.) with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable in recessed heavy duty ISI marked PVC conduit with modular switch and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. complete as required. Make of switch/plate: Legrand , Hager, Norysis, Captree, Schneider. Make of Cable: Finolex/Polycab/Havells/KEI Group - C |
| 103 | Wiring for twin light control point with 2x1.5 sq mm FRLS, PVC insulated copper conductor single core cable in recessed heavy duty pvc conduit,2 way modular switch,, modular plate, suitable size GI box and earthing the point with 1.5 sq mm FRLS, PVC insulated copper conductor cable etc as required.Make of switch/plate: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). Make of Cable: Finolex/Polycab/Havells/KEI |
| 104 | Wiring for circuit/ submain wiring along with earth wire with following sizes of FRLS, PVC insulated copper conductor, single core cable in surface/recessed heavy duty PVC conduit including cutting the wall and making good the same in case of recessed conduit as required. Make of cable: Finolex/Polycab/Havells/KEI Pipe Make of PVC pipe: Diplast, BEC,AKG. 2 x 2.5 sq mm + 1 x 2.5 sq mm as earth wire |
| 105 | 2 x 4.0 sq mm + 1 x 4.0 sq mm as earth wire |
| 106 | Supplying and fixing of following size of heavy duty ISI marked PVC conduit alongwith accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Make of PVC pipe: Diplast, BEC,AKG.25mm |
| 107 | Supplying and fixing suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16 A modular socket outlet and 6 pin 5/6A &15/16 A modular switch, connection etc. as required. Make: Hager,Legrand, Northwest Wipro, Norysis, Captree, Schneider. |
| 108 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ woodenblock including connection etc. as required. |
| 109 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 110 | MODULAR GI BOXESSupplying and fixing following sizes / modules, GI box along with Modular base & cover plate for modular switches in recess etc as required. Make: Legrand, Hager, Norysis, Captree, Schneider.3 Module (100mm x75 mm) |
| 111 | 6 Module (200mm x 75mm) |
| 112 | 8 Module (125mm x125mm) |
| 113 | 12 Module ((200mmX150mm)) |
| 114 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connectioN.S (M.R) but excluding modular plate etc. as required. Make: Legrand, Hager, Norysis , Captree, Schneider3 pin 5/6 amp switch outlet |
| 115 | 15/16 amps switch outlet |
| 116 | 3 pin 5/6 amp socket outlet |
| 117 | 15/16 amps socket outlet |
| 118 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Make: Legrand, Hager, Norysis , Captree, Schneider. |
| 119 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos 3 Pin 5/6Amp. Modular socket outlet and 2 Nos 5/6Amp modular switch, connections etc. as required. Make: Legrand, Hager, Norysis , Captree, Schneider. |
| 120 | Supplying and fixing modular blanking plate on the exixting modular plate & switch box excluding modular plate as required .Make: Legrand, Hager, Norysis , Captree, Schneider. |
| 121 | Supply & Laying of DWC pipe 50/63mm with hand bockey:-Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /Gemini.. The pipe should be laid below ground/road level by digging the ground upto75 cm less excavation or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work. |
| 122 | Supply & Laying of DWC pipe103/120mm with hand bockey:-Supply and laying of103/120 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /Gemini.. The pipe should be laid 3 feet below ground/road level by digging the ground upto 3 feet or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work. |
| 123 | Supply & Laying of DWC pipe 50/63mm with out hand bockey:-Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /Gemini. The pipe should be laid 75 cm below ground/road level by digging the ground or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work. |
| 124 | Supply & Laying of DWC pipe 103/120mm with out hand bockey:-Supply and laying of 103/120 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /Gemini.. The pipe should be laid 3 feet below ground/road level by digging the ground upto 3 feet or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work. |
| 125 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make: Finolex/Polycab/Havells/KEI 3x 1.5 sq. mm |
| 126 | 3x 2.5 sq. mm |
| 127 | 3x 4 sq. mm |
| 128 | 3x 6 sq. mm |
| 129 | Providing & fixing of 4C*2.5 Sqmm. Electrical Copper wire for B/w IDU & ODU Power supply with complete in all respect. Make: Havell, Finolex & Polycab. |
| 130 | Providing & fixing of 4C*4 Sqmm. Electrical Copper wire for B/w IDU & ODU Power supply with complete in all respect. Make: Havell, Finolex & Polycab. |
| 131 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole Make: Make: Seimens, Schneider, Legrand, L&T, Hager. |
| 132 | Supplying and fixing 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole Make: Seimens, Schneider, Legrand, L&T, Hager. |
| 133 | S/F TPN MCB Supply and Fixing following rating, four pole, 415 volts, MCB TPN with box complete with connections tensing and commissioning etc as required. Make: Seimens, Schneider, Legrand, L&T, Hager. The work shall be executed to the entire satisfaction of Engineer in charge. 63 Amps |
| 134 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door Make: Seimens, Schneider Acti 9., Legrand, L&T, Hager, |
| 135 | Providing and fixing 100 A 36 KA 4 POLE rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Make: ABB, Havells, Schneider, Legrand, L&T, Hager. |
| 136 | Providing and fixing 125 A 36 KA 4 POLE rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel, making connections, etc. as required. Make: ABB, Havells, Schneider, Legrand, L&T. |
| 137 | Providing and fixing following rating MCCB 4 pole 415 Volt ( Thermal magnetic / microprocessor release without MS enclosure for Over load and short circuit protection, 35-55 KA Breaking capacity (Is=100% [Icu) with positive isolation. The overload & short circuit release shall be of Adjustable Type. The MCCB is to be installed in existing cubicle panel / angle iron board including drilling holes in cubicle panel / angle iron board, making connections with suitable rating of copper wire / copper strip etc. as required. The job includes the cost of spreaders terminal links etc. asrequired. 400 Amp 4 PoleMCCB(Microprocessor release). The MCCB should be of L&T/ Siemens/ Schneider/Legrand/ ABB/ Hager make only. |
| 138 | Supply and erection of 400 Amp. 415Volt.4 pole ON Load Change over switch with MS enclosure of following ratings installed in existing switch board/ TL Panel with nuts & bolts of requisite size after making holes etc. The job includes cost of making inter connection with suitable rating copper wire / copper strip with dowels, lugs & thimbles duly crimped, bonding to existing earth and carriage, testing & commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. Make L&T/ Siemens/ Schneider/ Legrand/ ABB/ Hager/Havells/HPL make only. |
| 139 | Providing and fixing circular/ hexagonal cast iron or MS sheet box for ceiling fan clamp of internal dia 140 mm, 73mm height top lid of 1.5 mm thick MS sheet with its top surface hacked for proper bonding, top lid shall be screwed in to the cast iron/ MS sheet box by mens of 3.3 mm dia round headed screws one lock at the corners. Clamp shall be made of 12 mm dia MS bar bent to shape as per standard drawing. |
| 140 | G.I. Earth pipe electrode with salt/ Charcoal: Supply and laying of earth electrode made out of ISI marked 'B' class G.I. pipe 4.5 Mtr. long 40 mm dia including accessories. GI pipe electrode shall be cut tapered at the bottom and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom. The earth electode shall be laid in ground after boring as per CPWD specificationscomplete in all respect and to the entire satification of the engineer-in-charge. |
| 141 | P/F 6 SWG GI earth wire: Providing & fixing earth connection from earth electrode with 6 SWG dia G.I. wire to pole, as required including nut, bolt washer and drillling hole etc to the entire satisfaction of Engineer-in-Charge. |
| 142 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 143 | Supplying and laying 25 mm X 5 mm G.l strip at 0.50 meter below ground as strip, earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm) |
| 144 | Supply and Erection of Three Phase ETP grade Copper Bus Bar with enclosure of rating 100 amp. to be fixed on wall/ in main incoming panel complete in all respects of make: Havells- IHBC020004 or equivalent in ABB/Schneider/Legrand.The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 145 | Supply and Erection of Three Phase ETP grade Copper Bus Bar with enclosure of rating 200 amp. to be fixed on wall/ in main incoming panel complete in all respects of make: Havells- IHBC020004 or equivalent in ABB/Schneider/Legrand.The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 146 | P/F of LED luminarie of size 2'x2' of 30-36 watt (595x595 mm) recess type including driver with minimum system efficacy of minimum 120 lm/W. THD <10%, PF > 0.95, Having coloured temperature 4000-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Havells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj alongwith connection, testing and commissioning erc. This job also includes all petty material required to be entire satisfaction of Engineer-in-charge. Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. |
| 147 | P/F of LED luminarie of size 2'x2' of 30-36 watt (595x595 mm) surface type including driver with minimum system efficacy of minimum 120 lm/W. THD <10%, PF > 0.95, Having coloured temperature 4000-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Havells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj alongwith connection, testing and commissioning erc. This job also includes all petty material required to be entire satisfaction of Engineer-in-charge. Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. |
| 148 | Supply & Erection of 1x18 watt retrofit LED tube rod with batten Supply & Erection of 1x18 watt retrofit LED tube rod with batten made of aluminium housing with PC diffuser Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should beHavells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj . The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 149 | Supply & Erection of 2x18 watt retrofit LED tube rod with batten Supply & Erection of 2x18 watt retrofit LED tube rod with batten made of aluminium housing with PC diffuser Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should be Havells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj . The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 150 | S/E of M.S. angle iron bracket of size40x40x6mm for installation of flood lights.The bracket should be painted with the coats of superior quality paint. The job includees all the material, labour including making holes in the bracket to fix the flood light fittings etc complete in all respect. The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 151 | Supply and erection of 14 GMS sheet frame of suitable size for erection of 12\\"/15\\"/18\\" sweep exhaust fan. The holder should be suitable for12\\"/15\\"/18\\" sweep exhaust fan shall be cut from the centre of the sheet and bedding 1/4\\"round collar with round cut and duly fixed with existing ventilator frame with suitable arrangement after removing the existing glass. The exhaust fan frame shall be painted on both side with superior quality paint after one coat of primer. The job includes the cost of M.S strips of 1\\"×1/4\\" and other petty material required to complete the job to the entire satisfaction of E.I.C |
| 152 | S/E of M.S. angle iron board covered with 14 GMS sheet fixed in to the nitch for mounting switchgear. The switches/ BDB's ELCB shall be provided with required no. of supporting member of M.S flat 25mm x 5mm to bring all the switchgear in one level including bonding the board switchgear etc. to the existing earth. The board shall be fabricated out of 40mm x 40mm x 5mm angle iron frame and shall be covered with a 14 GMS sheet duly welded for erection of switchgear items on it. The board shall be painted with two coat of approved shade of superior quality paint after one coat of primer. The rate includes carriage from factory to site, erection charges in the niche and other petty material required at site of work. |
| 153 | Making of haudi of 1.5'x1.5' size for drawing of underground cable etc constructed with bricks wall 4 ½\\" thick and plastered from the inner side with cement, sand, mixture 1:5. The RCC cover moulded in an angle frame of size 35mm x 35mm x 5mm should be provided above the Haudi which should rest on 40mm x 40mm x 5mm angle iron frame fixed on the upper portion of the Haudi. The cover should be provided with lifting arrangement. The rate includes all labour and material to complete the job with 1:4 CC mixture. |
| 154 | Supplying and fixing following sizes / modules, GI box along with Modular base & cover plate for modular switches in recess etc as required. Make: Legrand, Hager, Norysis, Captree, Schneider. 16 MODULE |
| 155 | S / E of ceiling fans complete with aluminium blades, plastic canopies 2 Nos. double bal bearing, MS hanging rods, condenser, reels, clamps etc. The body of fan and blades should be white in colour. The job includes the cost of making necessary connections from the adjacent light point with 1.5sq.mm single core copper conductor cable. The sample of fans shall be gotapproved from the Engineer-in-charge of work before installation at site. The job also includes the cost of carriage, erection, testing, commissioning of fan, all labour and petty material required to complete the job to the entire satisfaction of the Engineer-in-Charge.[Size56\\" 1400mm sweep ceiling fan of Havells make Velocity White / Orient make Summer Breeze Crompton make Cool Breeze / Usha make Apollo Bajaj make Sabse. Tez only |
| 156 | Supply and Erection of Exhaust fan (heavy duty motor with copper wound metallic body) following size complete with motor, mettalic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation,epoxy powder coating along with mettalic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. Size 12\\" Sweep 900 RPM with louver of Havells make Turbo Force SP/ Orient make Industrial heavy duty / Crompton make HDEF EXHD 300- 6-1 / Bajaj make Supreme DLX only. |
| 157 | Supply,Installation, Testing and Commissionng of wall fan 400 mm (ISI mark) including cost of petty material required to complete the job in all respect. (Make Crompton/Havells / Armonard/ Bajaj) complete in all respect.There shall be free replacement at site for a period of five year from the date of delivery, Toll free number shall be provided by the supplier to the client Exhaust fan , wall fan etc. Complete in all respect, as required. |
| 158 | P/F of heavy duty Air Circulator Wall fans of size 450 mm, RPM 1400± 5%, power input 120-130 watt, 220-240 volt, 50Hz single phase, 3 speed of Make Crompton/ Havells/ Phillips/Bajaj/Khaitan. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 159 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making bearing good the damage, Carriage Charges connection testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. [Size 15inches (380mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver ofHavells (Turbo Force SP) / Crompton (EXHD380-6. (1) / Orient (Industrial Heavy duty)/ Usha (Turbo HDEF)/ Bajaj (Supreme Plus) make only. |
| 160 | Providing & Fixing Cable Junction box of size 250x200x100mm complete in all respect. The job included fixing of Junction box on the wall with all petty material as required. The work shall be executed to the entire satisfaction of Engineer-in-Charge. Make: Sintex, Hensel, Rittal |
| 161 | Supply and laying of insulated 2 core x 10mm2 aluminium multi conductor twin core flat unarmoured cable to fixed on the suitable clamps and nuts /bolts etc make Cirtina/finolex/ lapp/ polycab/ havell's or its equivalent of ISI marked. The work shall be executed to the entire satisfaction of engineer-in-charge. |
| 162 | Supply & laying of ISI marked 3.5 core 150 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 3.5 core 150 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.3. The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 163 | Supply & laying of ISI marked 4 core 16 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 16 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.1 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 164 | Supply & laying of ISI marked 4 core 35 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 35 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.2 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 165 | Supply & laying of ISI marked 4 core 50mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 50 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.2 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 166 | Supply & laying of ISI marked 4 core 70mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 70 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.2 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 167 | Outdoor type M.S. Cubical Pedestal : S&E of Outdoor type BOTH SIDE OPEN ABLE M.S. Cubical Pedestal of size 1200mmx 900mm x350mm fabricated from 16 G.M.S. sheet welded on M.S. angle iron frame of size 50mmx 50mm x6mm with 4 Nos. legs of angle iron of same size each of length 600mm with M.S. sheet of size 100mmx100mmx6mm thick at the bottom of the legs. The front side of the pedestal should be openable with hiunged door provided with Godrej type locking arrangements. A 'U' type support made from M.S. sheet of 16 G having width 75mmx6mm be welded vertically in the inner side of the door to avoid entry of water. The door of the pedestal should be provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. M.S. sheet of 16 G thickness and 1200mm x 150mm size be fixed at the front to cover the entry of cables. Four No. supporting members each of size 50mmx6mm thick according to cubical size shall be welded for mounting switcher gear i.e. ICTPN,BBC, Timer and energy meter etc. The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. The legs of the pedestal shall be embedded in the 1:2:4 R C.C. mixture by digging 1½' deep as required. The letter 'M.C.C.' in 4\\" size shall be written on the front door of the Pedestal. The job also includes Supply & erection one No. wooden plank/ board of size 1'-6\\" x 1'-6\\" and 25mm thick suitable for fixing energy meter including cost of screws, nuts & bolts in cubical pedestal complete in all respects. The pedestal will be housed on RCC Foundation platform of size 900 mm deep (450 mm underground and 450 mm above ground x 910 mm long x 360 mm wide including sufficient number of entries for cable with DWC pipe The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 168 | Supply, Installation, Testing and Commissioning of double door type LT panel (loadbank 8way ) of suitable size, dust and vermin proof, fabricated out of 1.6mm thick CRCA sheet steel, power coated with 11 tank process, for better environment protect . MCCB panel board should be manufactured and supplied by ISO-9001 certified OEM of MCCB. The panel board should be suitable for floor or wall mounted and should be of robust constructions. Panel should have cable alleys on both sides for easy cable termination & digital metering module shall also be provided. Make of panel Havells CAT No: - IHLGF4000800 or its equivalent in ABB/Schneider/Legrand. The panel board should comprise of the followings.a) Copper Bus Bar of rating equal or higher than the incomer MCCB current rating.b) Incomer MCCB Rating 400A, 4Pole, 50kA, Ics= Icu= 100%(Makes: Havells, ABB/Schneider/Legrand/Hager)c) Outgoing MCCB, Rating 200A (2nos), 4Pole, 36kA,Ics= Icu= 100% (Makes: Havells, ABB/Schneider/Legrand/Hager) d) Outgoing MCCB, Rating 100A (6nos), 4Pole, 25kA,Ics= Icu= 50% (Makes: Havells, ABB/Schneider/Legrand/Hager) |
| 169 | Supply and erection of automatic street light panel of Havells/Legrand make or equivalent of ABB/ Siemens which should control automatic switching of light that can be repeated on daily basis, suitable to a load of 6KW of frame size with FRLS internal wiring and class H insulation. It should have following provisions: i) Incoming and outgoing terminal block with auto manual switch. ii) Incoming MCB TPN. iii) Contactor of suitable size with MCB SP. iv) Astronomaical Digital 24 hours timer. v) Outing MCB SP. vi) All the above equipment is housed in CRCA sheet enclosure with gasket for makng it water/ vermin proof, the detail product view showing internal arrangement of equipment is attached with estimate. The job includes cost of wo no. legs 3.5 feet long each made out of 50mm x 50mm x 5mm angle iron grouted in ground with cement concrete of ratio 1:2:4 and other petty required to complete the job to the entire satisfaction of EIC. |
| 170 | SITC of 01 No./13 Passenger lift 884Kgs/ 1mps speed / Travel 8Mtr. (approx)/B+G+1/3Stops/3Openings/Shaft Size required: 2500mmwxl900mmd/Car Size: AS PER IS STD/Clear Opening:900mmwx2000mmh/Pit-1700mm/Headroom4500mm/Center Openingdoors//V3F Microprocessor based Selective Collective Simplex control/ Car- SS Honeycomb Centre opening power operated car door in SS Honeycomb/ Centre opening power operated landing door in SS Honeycomb/ PVC flooring protection/ 1 hrs. Fire rates doors Automatic Rescue Device/ Infra- Red Screen Sensor/Auto Light and fan off / over load warning indicator with announcement/ SS handrail/ SS False ceiling in car/ Dot Matrix LED D & P Indicators in car and landings - Orange colour/ Push button- orange LED illumination/ 2 way intercom- press and speaker/ full car operating panel/ full loaded by pass/ floor Annunciator with music/ Sill Angle Sill Support/ Fireman's Switch/ battery operated alarm bell and emergency light/ minor builders work/ Scaffolding/ Pit leader/ Lift license/ Free Service for one year/ All std. Govt. features.The make of lift shall be Kone, Mitsubishi, Schindler or Johnson lifts only. |
| 171 | Supply and erection of 01 No./250 kgs dumb waiter lift/0.34 Mps speed/ travel 8 mtr. (aaprox)/ G+1/ 2 stop/2 opening/ shaft size required: 1500mmw x 1200mmd/ car size: 1000mW x 1000mm D x 1200mm H/ Clear opening: 100mm W x 1200mm H/ M S painted car body and doors/ collapsible landing door/PVC flooring/ control: External extended push buttons with/ without attet/\\" UP\\" & \\"Down\\" arrows in landings onlysteel cubicle for controller/ minor builders work/ scaffolding/ Free service. The make of lift shall be Kone, Mitsubishi, Schindler or Johnson lifts only. |
| 172 | Supply and erection of 8 way double door, IP-43 metal door, recess mounting, vertical type, 415 volt, VTPN MCB distribution board of sheet steel, dust protected, duly powder painted, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs ( but without MCBs and incomer) suitable for MCCB upto 160Amp. The job includes the cost of making connections, testing, commissioning, labour and other petty material etc. as required to complete the job to the entire satisfaction of EIC. Make: Schneider, Legrand, Acti9, Hager, Seimens. |
| 173 | S/I/T/C of Split Type AC- 2.0 -ton Cooling only with 24000 Btu/Hr cooling capacity. The AC Have 3.5 EER ratio (Inverter 3-star rating) with rotary sealed compressor operating on refringent R-410-A suitable for wall mounting remote control including piping / Electrical Wire between indoor & outdoor up to Three meter with sleeve in type insulation to the entire satisfaction of Engineer-in charge. Make: Daikin, Voltas, Carrier/ Hitachi. |
| 174 | Ductable Unit: S/I/T/C Duct able unit of Direct Expansion type AIR COOLED DUCTABLE UNITS of SCROLL semi hermetic single compressor suitable for R 410 A/R 407C refrigerant in each Unit. The Indoor Units shall be connected with Outdoor Units having suitable Coil surface area with Sub cooling circuit and Hydrophilic Blue Fins, Outdoor Fan motor. Indoor Unit shall have 3RD Coil, DIDW BLOWER with motor, Micro Processor based LCD Controller with Self Diagnosis function, Auto Start mode, Energy saving, Motor Protection device, Anti-recycle timer, Inbuilt temperature sensor and programmable controller. Micro processor control panel suitable for operation on 415 V, 3 phas , 50 Hz etc complete as required .The Refrigent Gas Should Be Factory Charged. Each unit shall comprise of separate Indoor and outdoor unit with standard packing of unit. Make: Daikin, Voltas, Carrier/ Hitachi.. 11 TR Capacity |
| 175 | Cassette Unit : S/I/T/C of Four–way Cassette Type AC with cooling, filtration, circulation and dehumidification. The unit shall have inbuilt drain pump for draining water. The AC Have 3.5 EER ratio (Inverter rating) with rotary sealed compressor operating on refrigerant R-410A/R32 suitable for wall mounting remote control. The entire satisfaction of Engineer-in-charge. Make: Daikin, Voltas, Carrier/ Hitachi. 2.5 TR Four-way Cassette Type. 2.5 TR Four-way Cassette Type. |
| 176 | Supplying & Installation of interconnecting following size of refrigerant copper pipe work with fitting duly insulated with 9/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M.S. hanger. Make:Totaline,Maxflow,Rajco6.4 mm dia with 9mm thick nitrile rubberr insulation |
| 177 | 9.53 mm dia with 9mm thick nitrile rubber insulation |
| 178 | 12.07 mm dia with 9mm thick nitrile rubber insulation |
| 179 | 19.05 mm dia with 13mm thick nitrile rubber insulation |
| 180 | 22.2 mm dia with 13mm thick nitrile rubber insulation |
| 181 | DUCT INSULATION:Supply and fixing Thermal Insulation material shall be Nitrile Rubber Thermal conductivity of the insulation material shall not exceed 0.047 W/moK at an average temperature of 20°C. Density of the nitrile rubber shall be 140 – 180 Kg/m3. The material should withstand maximum surface temperature of +85°C and minimum surface temperature of -20°C. The material should confirm to Class A rating for surface spread of Flame in accordance to manufacturing standred.9mm |
| 182 | Ducting: Supply, installation, balancing and commissioning of Site fabricated GSS sheet metal rectangular ducting with supports as per IS 655-2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following gauges (Galvanizing shall be with zinc nominal 120 gm/sqmtr):- 24gThickness0.63mmsheet |
| 183 | 22gThickness0.80mmsheet |
| 184 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. |
| 185 | Supplying & fixing of powder coated extruded aluminium Supply/Return Air Grills with aluminium volume control dampers as per specifications. |
| 186 | Supplying & fixing of powder coated extruded aluminium Eye Boll Diffuser with volume control dampers complete as required. |
| 187 | SITC of cable tray (Punched Hole) of 300*50*1.2 mm size with hanger spot, Jointing etc. as per specification. |
| 188 | S/I/T/C of Voltage stabilizer 5 KVA for AC up to 2 Tr with MCB, TDR volt meter copper winding input range 180–250-volt single phase including cost of copper wire from stabilizer to A.C unit with M.S body of 22-gauge sheet powder coated). Make DEOL/Jewel/V-guard |
| 189 | Providing & Fixing PVC rigid drain pipe 25 mm (3/4\\") dia of Diplast/ finolex make of complete in all respects from indoor unit to disposal points as directed by EIC. |
| 190 | SITC of Electrical distribution Sub panel of size 1200*950*350 mm(H*W*D) for VRV ODU and AHUs etc including MCCBs, Lamp, Capacitors and other switchgear. The Panel made from 2 mm thin CRCA sheet steel indoor type , fixed type, Floor/ Wall mounted, powder coated with siemen grey shed (RAL 7032) , Single front , Top/ Below cable entry, detechable gland plate having Aluminum busbar of 200 Amp. , Digital voltmeter and ammeter, current density 1 Amp/mm2 LED phase indicatior, base channels etc. • Incomer -1 nos. -\\"200 A 3 phase MCCB ,TMD Release , Standard extended rotary handle, Multifunction energy meter with POP , Next gen Pro LED indicator (Red, Yellow & Blue) etc.\\" • Outgoing-6Nos -\\"Each have 100 Amp. MCCB, 3 phase preventer, 3 Contactor with NO/NC, with stdr. Colour wiring. ON/OFF indicator etc.\\" • Outgoing-16 Nos.-Each have 15 Amp. MCB DB, Single phase, etc. ( Make of panel: Tricolite,ECS, Ambit, International Switchgear, Amco, Kalyani Switchgear) having CPRI test certificate and follow ISO 9001-2008. Make of MCCBs,ACB, MCB, Contactors, Lamps, Capacitors: Schneider, ABB, Legrand, L&T, Siemens, Hager. |
| 191 | Supplying, installation, Testing and Commissioning of Split Type AC 1.5 Ton, 3 Star Rating. The AC shall be Suitable for 230 +/- 10% volts, 50 Hz Ac supply. The AC EER not less than 3.55 supply with Copper condenser. 1.5 Ton Capacity of nominal cooling capacity 4500 kilo calories/Hr./18000 BTU/Hr. with permissible variation of +/- 10%. Room discharge air flow 650 cfm indoor Nosie level not exceed 50 db. Refrigent 410 A. and complete to the entire satisfaction of Engineer-in-charge. Make: Carrieer/Voltas/Hitachi/Daikin/Mitsubishi with warranty of 3 years |
| 192 | Supplying and Fixing Voltage stabilizer 4 KVA for AC upto 1.50 TR with MCB, TDR volt meter copper winding input range 180–250-volt single phase including cost of copper wire from stabilizer to A.C unit with M.S body of 22 gauge sheet powder coated). Make DEOL/Jewel/V-guard with warranty of 2years |
| 193 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Make: Surya, Wipro, Havells, Bajaj, Panasonic. |
| 194 | Supply of 10W Wall mounted LED bulk head ligh delivering minimum system lumen of 1000 lm and te luminaire shall be with system efficiency> 100lm/W Housing and Rim is pressure Die cast aluminium, IP65, IK 10 optics: Polycarbonate opal high transmissive Diffuser, Ambient temp 45degC. The Operating CCT shall be 4000/5700K with CRI of >80. The lumiaire shall be Bis registed with Electronic driver with input Voltage range of 140 to 265V, THD> 10% & PF>0.95, 50,000Hrs Luminaire Life with L70 Criteria. Shall have minimum surge protection of 2.5KV The LED Driver shall be easily availible in India for repair and service. The LED shall be SMD type. The luminaire shall be with following certification. LM79&LM80 issued by LED Manufacture along with Phote biological safety standard. It should have Electrical Class insulation Detailed specification, SLA and other information to be given in DNIT condition. preferred make list are attached as annexure. Rate includes the comprehensive warrantee of 2 years from the commissioning. The fitting should be make Philips/ Crompton/ Havells/ Surya/ Wipro/ Bajaj.Work must be complete to the entire satisfaction of engineer in charge |
| 195 | S/I/T/C18- 20W LED Downlighter, MINIMUM 100 Lumens/watt, THD <10%, Pf > 0.95, CCCV driver, protection IP 20, and CCT 4000-5700K, Surge protection 4kV, Operating Voltage Range - 150V – 270Volts.Wattage - 18-20 watt MAKE- philips ,Wipro,Trilux,Osram,Havells, Jaquar complete in all respect.Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. The work shall be executed to the entire satisfaction of Engineer-in-charge |
| 196 | S/I/T/C OF 8-12 Watt LED Downlighter, made of extruded aluminium housing and high power LED as alight source wih clear diffuser and seperate electronic driver with minimum 95 Lumens/watt, THD <10%, Pf > 0.95, protection IP 20, and CCT 4000-5700K, Surge protection 4kV, Operating Voltage Range - 150V – 270Volts.MAKE- philips ,Wipro,Trilux,Osram,Havells, JAGUAR complete in all respect.Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. The work shall be executed to the entire satisfaction of Engineer-in-charge |
| 197 | Supply,Installation, Testing and Commissionng LED cove Strip light 5mtr with 4.8W/mtr and 2 amps complete with LED driver of make PHILIPS/osram/havells/wipro trilux/opple, Jaguar ., (2 years Warranty). complete in all respect.The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 198 | SI/T/C of bi-directional CT meter alongwith 03 Nos. of CTs 200/5 Amp including meter box of required size for placement of meter and CTs of make- L&T, Secure or approved make by electricty department. The job includes testing of the meter from lab including paying the testing charges taken by electricity department. |
| 199 | Fabrication & erection of steel shutters for electrical niches as per following specifications FRAME: The shutter of suitable dimensions for electrical nitch shall be made out of 16 G.M.S.sheet. The shutter frame shall be 1-1/2”x1-1/2”x1-1/2” channel frame 4 Nos. ‘L’ type holdfasts for fixing the same on the wall. The size of the shutter frame should be suitable for 2Nos. door panels/single panel depending upon the size of nitchesDOOR PANEL: The door panel shall have support in U-Shape formation made from 16G.M.S. sheet with 4”x3/4”M.S. channel duly spot welded to give additional strength. The door panel shall be fixed with frame with the help of concealed M.S. hinges of suitable size having good strength. The door panel shall be provided with a bolting arrangement either of Godrej type or such type so as to interlock the door panel with frame. The handle shall be of superior quality and nickel plated to facilitate its opening. The door panel must have as arrangement to provide a pad lock. FINISHING: The frame & the door panel should be given anti-rust, anti-grease and phosphate treatment with 3 in 1 paste and then spray painted with two coats of paint of superior quality. The shutter should be earthed properly with the existing earth with No.8SWG wire after erasing the paint from the body of the Shutter. The rate includes cost of all labor and material reqd. to complete the job to the satisfaction of the Engineer-in-charge. |
| 200 | Fire Exinguisher ABC Type : Supply and installation of ABC Type Stored Pressure Fire Exinguisher with capacity of 6 Kg with wall mount brocket Make: Safeex or Safepro. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 201 | Fire Exinguisher CO2 Type: Supply and installation of CO2 Type Fire Exinguisher with 1 meter hose and PVC Horn with capacity of4.5 Kg with wall mount bracket Make: Safeex or Safepro. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 202 | Supply/Erection/Testing & Commissioning of 40 Watt LED Post Top Lantern of 4000-6000K made up of Die cast Aluminium base & spun Aluminium top fitted with LED PT Module. The power LED's are mounted directly on inbuilt extruded Aluminium Heat Sinks. It should have UV stabilized injection molded P.C. Opal/Frosted Diffuser which is provided for Glare free Lighting with high Visual comfort. The fitting should be suitable for mounting on pole having dia 60-75 mm, system efficacy more than 80 lumen/ watt, power factor ≥ 0.9, IP 65 protection and of make K-Lite / Twinkle (LUXMAX-PT-161A) / Bajaj only. The job should be carried out upto the entire satisfaction of Engineer-in-charge. Warranty: The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. |
| 203 | Supply and Erection of 4 Mtrs long Decorative Galvanised mild steel Pole Including Foundation.Design, Supply & Erection of decorative Galvanised mild steel Pole having total length of 4.0 mtr with MS base plate of size 250x250x12 mm with 114mm dia and 4mm thickness of the bottom portion and 75mm dia and 3mm thickness of top portion with Cast Aluminium embellishments at the middle of the pole. The pole should be provided with a cut out at the bottom for making necessary connection including a 25 Amp MCB of good quality. The pole should be painted with PU paint.025 color black as per Engineer direction. The cut out should have lockable flush door for orotection of connections. The make of the pole should be Bajaj, Schreder, Twinkle, K-Lite, Keslec or its equivalent. The work shall be executed to the entire satisfaction of Engineer-in-Charge. The rates are inclusive of costing of foundation for erection of pole. The dimensions are with Production tolerance ± 3%. |
| 204 | Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plantconforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, copper/G.I plate earthing(AC/DC side seperately), mounted on Aluminium/GI structure of suitable strength and all bolts, nuts, fasners shall be of stainless steel/hot dipped Galvanised with following components complete as required:-a) Solar Photovoltaic Module of capacity 545 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2, IS-16170/IEC 61853, IEC-61701. Solar Photovoltaic Module conversion efficiency shall not be less than 20.9%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.Rated power of solar PV module shall have maximum tolerance upto +/- 3% and minimum fill factor of 75% to be used. Performance ratio (PR) should be show on Minimum of 75% at the time of initial commissioning etc. PV panel must have RFID , shall able to withstand windspeed as per standard and all other specifications mentioned in conditions of DNIT.b) Power Conditioning Unit (PCU) of 150-450 V/200-1000V (as per requirement) DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, conferming to IEC-62109, IEC/IS 61683,IEC-62116/60068, IEC-60255-27,IEC61000-2,3,5. Output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. It should run on MPPT, PCU/Inverter shall have overload capacity of minimum 10%, micro processor/ DSP controller, idling current at no load must not exceed 2% of rated current.c) Mounting Structure: Mounting structure to be Hot dip Galvnised iron/M.S. structure of suitable strength and all bolts, nuts, fastners shall be of stainless steel/ hot dip galvnised and as per BIS standard. Rate includes the required work to be done at flat surface/ slant surface and height of mounting structure may increase as per site requirement. Also rate includes the stairs, pathways any other material required for smooth running of solar plant. |
| 205 | d) Data Monitoring System: There should be an provision of online monitoring in the system. The system should include all the provision for making the units IOT/COMPATIBLE for connection with the SCADA (should be GSM Sim base/wifi based) building Sector-17. e) Others: Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc.as required. Lightning and surge voltage protection (both ac and dc), Islanding protection.Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. f) Document Submission:Agency to submit the detailed survey report (Tilt angle, no of module, capacity, no of aray, positions etc) of optimised solar generation to engineer in charge for approval. Also, preparation and submission of drawings/documents/Data sheet/BOM (Civil/electrical/mechanical), shadow analysis reports and quality assurance plan cover in the scope of agency and all the product must be approved from Engineer in charge before despatch to site. g)Warrantee: There shall be warrantee of 25 years for solar panel and 10 years for all other material including PCU unit from date of commissioni h) Annual maintenance contract (AMC): Regular operation and maintenance of the SPV power plant for a period of ten years after commissioning along with replacement of any items as and whwn necessary as all the items are comprehensively warranted for 10 years under the operation and maintenance contract. Plant must be in running conditions all the time and penalty clause and detailed conditions are mentioned in DNIT conditions. Rate includes all the devices/ work required to make system operational till energy meter/ compact substation. Detail specifications of all items are given in DNIT conditions. Prefred makes are mentioned as annexure. |
| 206 | SI/T/C of full crystal chandelier (round shape) with in-built lights, 1000mm in dia with three colour variant, with metal to ped golden PVD finished. |
| 207 | Supply and Installation of wall mounted bracket having provision of installing one no. of post top decorative fittings. The total length of the bracket should be minimum 750 mm and height of the bracket should be minimum 485 mm. Make of the bracket should be LuxMax-BKT211 or equivalent of Bajaj, Keslec, Surya, Havells. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 208 | PART C PUBLIC HEALTH WORK AND RAIN HARVESING WORKSUB HEAD 1 PUBLIC HEALTH WORK |
| 209 | Providing and fixing soil, waste and vent pipes Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989100 mm dia |
| 210 | 75 mm dia |
| 211 | Providing and fixing plain bend of required degree Sand cast iron S&S as per IS : 3989100 mm dia |
| 212 | Providing /fixing single equal plain junction of required degree 100x100x100 mm Sand cast iron S&S as per IS - 3989 |
| 213 | 75x75x75 mm Sand cast iron S&S as per IS - 3989 |
| 214 | Providing and fixing Collar Sand cast iron S&S Pipe as per 100 mm dia Sand cast iron S&S as per IS - 3989 |
| 215 | Providing and fixing Collar Sand cast iron S&S Pipe as per 75 mm dia Sand cast iron S&S as per IS - 3989 |
| 216 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 75 mm outlet Sand cast iron S & S as per IS – 3989 |
| 217 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.20 mm dia nominal bore |
| 218 | 25 mm dia nominal bore |
| 219 | Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the walls complete in all respect15 mm dia nominal bore |
| 220 | 20 mm dia nominal bore |
| 221 | Providing and fixing G.I. pipes complete with G.I. fitting including trenching and refilling etc. complete in all respect. 20 mm dia |
| 222 | 25 mm dia |
| 223 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete in all respect |
| 224 | Providing and fixing 1 HP monoblock pump-set of single phase 240 volt including the cost of foundation, nuts, and bolts Complete in all respect |
| 225 | Brick work with F.P.S. bricks class designation 75 in foundation and plinth in Cement mortar 1:4 (1Cement: 4coarse sand). |
| 226 | Excavating trenches of required width for pipes, cables, etc. including excavation for sockets and dressing of sides, ramming of bottoms depth upto 1.5 including getting out the excavated soil, and then returning as required. In layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming watering, etc. and disposing of surplus excavated soil as directed with a lead of 50 m All kinds of soil etc.Pipes cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 227 | Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm |
| 228 | Providing laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 Cement : 1 fine sand) including testing of joints etc.150 mm diameter |
| 229 | Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design 150 mm diameter S.W. pipe |
| 230 | Providing and fixing square-mouth S.W. gully trap grade A complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame 300x300 mm size (inside)the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 kg 100x100 mm size P type With Sewer Bricks conferming to IS: 4885 |
| 231 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimension 500x700 mm and 45 cm deep for single pipe line With F.P.S. Bricks |
| 232 | Providing and fixing in position best Indian make ISI Marked Ball cock 20mm with brass rod, PVC ball complete in all respects. |
| 233 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws complete in all respect as per DNIT15 mm dia nominal bore |
| 234 | 20 mm dia nominal bore |
| 235 | 25 mm dia nominal bore |
| 236 | Providing and fixing G.I. tank nipple AVR make complete in all respect 20 mm dia nominal bore |
| 237 | 25 mm dia nominal bore |
| 238 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 239 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite stone slab colour black, Cherry/Ruby red Area of slab upto 0.50 sqm |
| 240 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low levels white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS 7231 with all fitting and fixtures complete including cutting and marking good the wall and floors wherever required etc. complete in all respect. W.C. pan with ISI marked white solid plastic seat and lid. |
| 241 | Providing and fixing in best Indian make C.P. jet complete in all respects. |
| 242 | Providing and fixing C.P. bib cock of approved quality (make jaquar) conforming to IS : 8931 15mm nominal bore. |
| 243 | Providing and fixing white vitreous China flat back half stall urinal of size 580x380x350mm without white PVC automatic flushing cistern but with fitting, standard size C.P. brass flush pipe, speaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556 C.I. trap with outlet grating and other coupling in C.P brass including painting of fitting complete in all respect. Single half stall urinal with 5 litrer PVC automatic flushing cistern |
| 244 | Providing and fixing white china ware star colour under counter wash hand basin size 56 cm x 43 cm Hind ware (model 10049) or any equivalent make parry ware etc as per instruction of EIC including the cost of wiking make C.P. 32 mm waste, chain type adjustable brackets, jaguar 167B/Nova make central hole mixer, including the cost of cutting granite for WHB and making hole in granite for fixing mixer plugs, screws, white cement, complete in all respct. |
| 245 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality (make Jaquar) conforming to IS: 8931 a) 15 mm nominal bore. |
| 246 | Providing and fixing uplasticised PVC connection pipe with brass unions. 30 cm length 15 mm nominal bore complete in all respect. |
| 247 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 248 | Providing and fixing in position best Indian make 5mm thick mirror mounted on water proof ply/PVC sheet ground fixed in position by means of 4 nos. chromium plated brass screw and washers, including the cost of wooden/fiber beeding alaround complete in all respect as per satisfaction of EIC. 600mm x 450mm |
| 249 | Providing and fixing MS holder-bat clamps od approved design to sand cast iron/ cast iron (spurn) pipe embedded in alnd including cement concrete blockds 10x10x10 cm of 1:2:4 mix in including cost of cutting holes and making good the walls etc.,100 mm dia |
| 250 | 75 mm dia |
| 251 | Providing and fixing Gun metal ferrule 25 mm including the cost of threading, taping, execution earth and refilling the same after connection complete in all respect |
| 252 | Cutting holes up to 30x30 cm in walls including making good the same with F.P.S. bricks complete in all respect. |
| 253 | Providing and fixing Gun Metal non return valve of approved quality (screwed end) ISI peat valve, complete in all respect25 mm dia nominal bore Horizontal |
| 254 | 25 mm dia nominal bore vertical |
| 255 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level 1:2:4 (Cement: 2 coarse sand: 4 graded stone aggregate 40 mm nominal size). |
| 256 | Providing and fixing chinaware urinal patition of standerd height and average width of 1 feet complete in all respect |
| 257 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete32 mm dia |
| 258 | 40 mm dia |
| 259 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. DSR Item no. 17.38100 mm Sand cast iron Sand cast iron S&S as per IS - 3989 |
| 260 | 75 mm Sand cast iron Sand cast iron S&S as per IS – 3989 |
| 261 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete100x100x100 mm Sand cast iron Sand cast iron S&S as per IS - 3989 |
| 262 | 75x75x75 mm Sand cast iron Sand cast iron S&S as per IS – 3989 |
| 263 | Providing and Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete in all respect. |
| 264 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. |
| 265 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore |
| 266 | 25 mm nominal bore |
| 267 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 268 | Provision for Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. |
| 269 | Providing G.I. pipes and fitting with synthetic enamel while point over a ready mixed prelming coat, bolts of approved quality for new work |
| 270 | Providing and fixing water meter cover 1’-6” x 1’-0” with frame made out of M.S sheet 18 gauge frame form angle 360mmx30mmx5mm with locking arrangement, painting complete in all respects. |
| 271 | Providing and fixing in position best quality Stainless steel sink (Jyna make) including brackets and 40 mm CP brass waste with CP brass chain, rubber plug, PVC waste pipe, including painting of fitting and brackets, cutting and making good in walls wherever required.1200 mm x 450 mm x 200 mm (net size excluding flat edge). |
| 272 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 273 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 274 | Centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform. |
| 275 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 Cement : 4 fine sand) |
| 276 | Providing Laying In Position Cement Concrete Of specified Grade Excluding Cast Of Centering And Shuttering – All work up to plinth level 1:5:10 ( 1 Cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size). |
| 277 | Earth work in excavation by mechanical means (Hydraulic exceeding) manual means in foundation or drain (not exceeding 1.5 m in width or 10 sqm on plan) in clouding dressing of sides and ramming of bottom, lift upto 1.5 m, including getting out the excavated soil as directed, within a lead of 50 mm. |
| 278 | Providing and laying non-pressure NP-2 class (light-Duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand)including testing of joints etc. complete. RCC Pipe NP- 2 18” i/d (450 mm) |
| 279 | RCC Pipe NP- 2 18” i/d (450 mm) |
| 280 | Providing and Fixing of horizontal RCC M-20 HD Road Gully cover and frames in 1:2 cement sent mortar on the top of brick masonry chamber complete in all respect as per entire satisfaction of E.I.Ci) Size of cover 690x537x80mm ii) Size frame 810x657x130mm |
| 281 | Providing and Fixing in position of pre-cast RCC Manhole cover and frame of required shape and approved quality HD- 20 circular 560mm i/d including the cost of carrige from store to site complete in all respect. |
| 282 | Providing orange colour safety foot rest of minimum 6mm brick plastic encapsulated as per IS : 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23mmx25mm and over all minimum length 263mm and width as 165 with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projection on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacture’s permanent identification mark to be visible even after fixing including fixing manholes with 30x20x15 cm cement concrete back 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) complete in all respect as per DSR. |
| 283 | Extra for cutting through mettaled roads and their foundations including sorting and screening and stacking the stone metal at site of work to the entire satisfaction of EIC. |
| 284 | Supplying and filling sand (recycled sand) under road crossing including carriage etc. complete in all respects to the entire satisfaction of the EIC. |
| 285 | Cutting holes up to 15x15 cm in RCC Floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe with cement concrete 1:2:4 (Cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including finishing complete in all respect. |
| 286 | Providing and fixing of IRC Jali 1”x1” angle 25x5 mm with locking arrangement and primer coat complete as per satisfaction of EIC. |
| 287 | Construction of Oil & Grease Trap for the Open kitchen/Litchen Complete in all respect as per satisfaction of EIC |
| 288 | Providing and fixing sensor type pressmatic angle valve Make jaquar complet in all respect as per statisfaction of EIC |
| 289 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the samematerials with snap fittings of approved quality and colour, weighing not lessthan 105 gms |
| 290 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 291 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 15 mm nominal bore |
| 292 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge |
| 293 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter |
| 294 | Providing and fixing C.P. brass shower Arm with 15 or 20 mm inlet : 150 mm diameter |
| 295 | Providing and fixing support (CP Graib rail of size 50mm dia and of 1.60 mm wall thickness) for disabled of person of suitable length as per site requirements complete to the entire satisfaction of EIC |
| 296 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 297 | Providing and fixing toilet paper holder : C.P. brass |
| 298 | Providing and fixing heel rest sanitary bend100 mm dia Sand cast iron S&S as per IS – 3989 |
| 299 | 75 mm dia Sand cast iron S&S as per IS – 3989 |
| 300 | Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 100 mm Sand cast iron S&S as per IS – 3989 |
| 301 | 75 mm Sand cast iron S&S as per IS – 3989 |
| 302 | Providing and fixing terminal guard : 100 mm, Sand cast iron S&S as per IS – 3989 |
| 303 | 75 mm, Sand cast iron S&S as per IS – 3989 |
| 304 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100mm |
| 305 | 75 mm |
| 306 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :100 mm diameter pipe |
| 307 | 75 mm diameter pipe |
| 308 | Providing and fixing sanitary napkin vending machine at ladies side with 50 refills far as per norms of MOUD for best toilets. Complete in all respect including the cost of equipments, Incinerator, battery for sanitary napkin machine AVM, taxes, Delivery charges ,installation charges, Training charges and warranty. |
| 309 | SUB HEAD 2 = RAIN HARVESTING WORK |
| 310 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m |
| 311 | Extra for every additional lift of 1.5 m or part thereof in. Depth exceeding 1.50 M but not exceeding 3.00 M All kinds of soil |
| 312 | Depth exceeding 3.00M but not exceeding 4.50 M |
| 313 | CONCRETE WORK |
| 314 | Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 315 | REINFORCED CEMENT CONCRETE |
| 316 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor level excluding cost of centering, shuttering, finishing and reinforcement. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 317 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 318 | Centering and shuttering including shuttering, propping etc. and removal of form to:- Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 319 | Suspended floors, roofs, landings, balconies and access platform |
| 320 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all completeThermo-Mechanically Treated bars |
| 321 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 560 mm internal diameter HD-20 |
| 322 | Steel work welded in buit up seciton / framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 in grating, frames, guard bar , ladder, railings, brackets, gates and similar wroks. |
| 323 | Boring / Drilling bore well of required dia for casing / strainer pipe by suitable method prescribed in IS :2800 (part), including collecting sample from different strata, preparing and submitting strata chart / bore log, including hire & running charges for all equipment, tools plant and machineries required for the Job, all complete as per direction of engineer – in charge, upto 90 meter depth below ground level. All types of soil.1 No. x 90mtr |
| 324 | Boring / Drilling bore well of required dia for casing / strainer pipe by suitable method prescribed in IS :2800 (part), including collecting sample from different strata, preparing and submitting strata chart / bore log, including hire & running charges for all equipment, tools plant and machineries required for the Job, all complete as per direction of engineer – in charge, beyond 90 meter & up to 150 meter depth below ground level.( for two nos. T/well 100 meter each)All types of soil.400 mm dia. ( 1 No. X 10 mtr) |
| 325 | Supplying, assembling, lowering and fixing in vertical position in bore well, unpalsticized PVC medium well screen (RMS) pipe with ribs, conforming to IS: 12818, including hire and labour charges, fitting and accessories etc. all complete, for all depths, as per direction of Engineer – in charge. 200 mm nominal size dia. (10 No. x 100 mtr) = 100-918 = 82 Mtr |
| 326 | Supplying, assembling, lowering and fixing in vertical position in bore well, unpalsticized PVC medium well screen (RMS) pipe with ribs, conforming to IS: 12818, including hire and labour charges, fitting and accessories etc. all complete, for all depths, as per direction of Engineer – in charge. 200 mm nominal size dia. (1 No. X 18 mtr = 18 mtr) |
| 327 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for leads & lifts, all complete as per direction of Engineer - in - charge. (1 No. X 4.95 cum = 4.95 cum) |
| 328 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in recharge pit, over the existing layer of boulders, in required thickness, for leads & lifts, all complete as per direction of Engineer - in - charge. |
| 329 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm, in recharge pit, in required thickness, over gravels layer, for all leads & lifts, all complete as per direction of Engineer - in - charge. |
| 330 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine / medium / coarse, in required grading and size as per actual requirement, all complete as per direction of Engineer – in charge. (1 No. X 16.49 cum = 16.49 cum) |
| 331 | Development of tube well in accordance with IS: 2800 (part I) and Is: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved, method, measuring static level and draw down etc. by step down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer – in – charge. (1 No. x 20 hrs= 20 hrs) |
| 332 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing / casing pipe, removable as per requirement, all complete for bore well of: 200MM Dia. |
| 333 | Providing and fixing M.S. clamp for required dia to the top of casing / house pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm dia. |
| 334 | Providing and fixing Bail plug / Buttom plug of required dia to the bottom of pipe assembly of tube well as per IS; 2800 (part I).200 mm dia. |
| 335 | Supplying and fixing of MS centering 8\\" Guides complete in all respects as per IS: 2800 (Part-I-1991 with uptodate amendments) complete in all respect. (1No. X 3 No. = 3 Nos.) |
| 336 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil |
| 337 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete:300 mm dia. R.C.C. pipe 150 ft x 1 No. = 150 ft or 45.73 mtr |
| 338 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) |
| 339 | 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 340 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 341 | Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access plateform. |
| 342 | Reinforcement for R. C. C. work including straighthening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars. |
| 343 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 344 | 12mm cement plaster finished with a floating coat of neat cement of mix: 1:4 (1 cement : 4 fine sand) |
| 345 | Dismanting manually / by mechanical means including stacking of serviceable material and disposal of userviceable material within 50 metres lead as per direction of Engineer-in-charge:water bound macadam road |
| 346 | Bituminous road |
| 347 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23mm x 25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent indentification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 348 | Providing and fixing in position pre-cast R. C.C. manhole cover and frame of required shape and approved quality. MD-10 Square shape 450mm internal dimension |
| 349 | HD-20 Circular shape 560 mm internal diameter |
| 350 | Providing and fixing per-cast SFRC horizontal raod gully cover and fram (Size 550mm x 450mm Complete at site. |
| 351 | Provision for cutting of cement concrete road for laying the RCC Pipe NP2 and reconstruction the same in original condition complete.(B&R Rates) |
| 352 | Providing & Fixing PVC pipe conforming to IS:4985 with upto date amendments having 6 kg pressure of 100mm for rain water pipe complete in all respects. |
| 353 | PART D FIRE FIGHTING WORK |
| 354 | Supplying, Laying, testing and commissioning of Kirloskar or equivalent reputed make pump DB 40/16 in back pull out design having 65mm suction, 40mm delivery, CI casting, bronze impeller and C-40 shaft with gland packed arrangement coupled on common base plate to Kirlosker/ABB (at our option) Make 5.5 KW/7.5 HP -uu2900 RPM TEFC Sq. cage induction motor suitable through suitable flexible coupliung. The pump set suitable for following duly points. Total Head : 35 Mtr. Flow/Discharge : 27 Cum/Hrs (450 LPM).(one no. functional and one no. for standby.) |
| 355 | Providing and fixing automatic control panel for required to operate of Terrace pump auto system complete in all respect as per satisfaction of EIC Make:- Power System/L & T. |
| 356 | Supplying and Laying copper flexible cable of i.1 KV grade of following size on from pamnel to motoe etc., as required make : Gloster/Havells/polycab. 4 x 16 mm2 (for terrace pump) |
| 357 | 1.5mm x 2 core (for terrace pump with pressure switch) |
| 358 | Providing and applying one coat of 4mm thick 'PYPKOTE' or COATEK anti rust pipe protection including approved primer of 2 coats as per manufacturers specifications and lap of 25 mm to make an impermeable layer on M.S.F. complete including surface preparation.100 mm dia : (NSI) |
| 359 | Supplying, Laying, Testing and Commissioning of C class heavy duty MS pipe for Rising Mains conforming to IS 1239 / 3589 complete with all fittings and accessories like elbows, tees, flanges, tapers, reducers, nuts, bolts, gaskets and washers including cutting, welding etc., providing cement concrete blocks as supports, anti corrosive treatment with coal tar / asphalt tape 4 mm thick as per IS 10221 and laying the pipe so that the top of the pipe is at a depth of 1 Meter below ground level complete as required of following sizes(NB) but excluding excavation (External Work);make : Jindal/TATA 25 mm dia : (NSI) |
| 360 | 40 mm dia : (NSI) |
| 361 | 50 mm dia : (NSI) |
| 362 | 80 mm dia : (NSI) |
| 363 | 100 mm dia : (NSI) |
| 364 | 150 mm dia : (NSI) |
| 365 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil :Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 366 | Supplying installation testing and commissioning of dual plate type Non return valve of following sizes complete with bolts, nuts, washer, rubber gasket etc. as required. Make : Zoloto/Kartar/L&T (NSI)80 mm dia |
| 367 | 100 mm dia |
| 368 | 150 mm dia |
| 369 | Supplying, fixing, testing and commissioning of Butterfly valves of PN 1.0 rating conforming to IS:13095 of following sizes with nitride seat and stainless steel stem with lever/gear operation and cast iron body in powder coated finish for firefighting application, complete as required. Make : Zoloto/Kartar/L&T (NSI)80 mm dia |
| 370 | 100 mm dia |
| 371 | 150 mm dia |
| 372 | Supplying, Installation, Testing and Commissioning of Air vessel 100mm external dish dia, 8mm thick and 1.5 mt. long with air release valve, drain valve as per IS:4738/1969. (for 2 No. wet risers). Complete in all respect as per satisfaction of EIC. |
| 373 | Supplying, Installation, Testing and Commissioning of Pressure switches suitable for operation of fire hydrant system for working pressure of 10.0 kg/cm2 including electrical control wiring with suitable rating PVC insulated and sheathed armored copper conductor control cable upto control panel, connections etc. as required complete to the entire satisfaction of EIC. Make: HONEYWELL/ DWYER/ DANFOSS/POTTER/System Sensor (NSI) |
| 374 | Supplying, Installation, Testing & Commissioning of pressure gauge suitable for operation with fire hydrant system for working pressure of 10.0Kg/cm2 i/c connection etc. as required complete to the entire satisfaction of EIC. Make: H-GURU/FEIBIG/WAREE (NSI) |
| 375 | Supplying and fixing 2 way Fire brigade connection (FBC) of CI body with 2 No. stainless steel inlet couplings complete with cap and chain as required. For 100mm dia M.S. Pipe connection conforming to IS : 904 as requirement complete to the entire satisfaction of EIC. (NSI) |
| 376 | Supplying and fixing of Hose cabinet of size 600mm x 300mm x 250mm made of 2mm thick MS sheet with 6mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 Nos. 15 mtr. Long Hose pipe, 1 No. branch pipe, mounted on wall OR raised bric platform & duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant, as required. (NSI) |
| 377 | Supplying and fixing First-Aid Hose Reel spray painted in Post office Red, conforming to IS 884 with upto date amendments, complete with the following as required complete to the entire satisfaction of EIC consisting of following : 30 mtr. Long 20mm (nominal internal) dia water hose Thermoplatic (Textile reinforced) Type-2 as per IS:12585 : 20 mm (nominal internal) dia gun metal globe valve & nozzle : Drum and brackets for fixing the equipments on wall : Connecions from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe |
| 378 | Supplying and fixing 100mm dia Gun metal branch pipe with 20mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required. |
| 379 | Supplying and fixing 100mm dia, 30 mtr. Long RRL hose pipe with 63mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required complete to the entire satisfaction of EIC. Make: CRC/ NEWAGE/PADIANI/JYOTI/SAFEX (NSI) |
| 380 | Supplying, & fixing 4.5 kg carbon Dioxide (CO2) portable fire extinguisher ISI marked under IS:2878 fully changed having cylinder body ISI marked under IS:15683 safety valve ISI marked under IS: 3224 with safety clip siphon tube, discharged bend & horn Complete with MS brackets for wall mounding etc., as required complete to the entire satisfaction of EIC. Make: Safex/Agni/Attasi |
| 381 | Supplying, & fixing of ABC type fire extinguisher 4 kg capacity ISI marked fitted with screw down type high pressure control valve conforming to IS: 15683 under IS:2878 fully changed having cylinder body ISI marked under IS:15683 with 1 Mtr. long wire braided high pressure discharge hose & electricity non conducting horn manufactured confirming to IS 2878 complete with initial charge, wall mounted bracket/screws etc., as required Make : Safex. |
| 382 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 383 | Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering – All Work Up to Plinth Level 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 40 Mm Nominal Size). |
| 384 | Photo lllumincent glow sign boards of suitable size as required complete to the entire satisfaction of EIC. |
| 385 | Providing and fixing of Gun metal valve with C.I. Wheel of 100 mm dia of approved make complete in all respect with entire satisfaction of EIC |
| 386 | Providing and fixing of G.I. pipe Union of size 32 mm dia complete in all respect with entire satisfaction of EIC |
| 387 | 50 mm dia |
| 388 | Providing and fixing of Gun metal Gate valve with C.I. wheel of 50mm dia of approved make complete in all respect with entire satisfaction of EIC |
| 389 | Providing and fixing of Ball Cock 50mm dia complete in all respect with entire satisfaction of EIC |
| 390 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level 1:5:10 with graded stone aggregate 40 mm nominal size). |
| 391 | Brick work with common clay F.P.S (non modular) bricks of class designation 75 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand). |
| 392 | 12 mm cement plaster finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 coarse sand) complete in all respect |
| 393 | Supplying, Installation, Testing and Commissioning of Manual Call point (MCP). as required complete to the entire satisfaction of EIC. Make: AGNI STAR/ AGNI DEVICE (NSI) |
| 394 | Supplying, Installation, Testing and Commissioning of hooter/sounder for use with fire Alarm to alret security system as required complete to the entire satisfaction of EIC. Make: AGNI STAR/ AGNI DEVICE (NSI) |
| 395 | Providing and fixing, testing & commissioning of manually operated fire alarm panel having capacity 220 Volts ACI 30 Volts 8 zone made out of CRC sheet having 18 gauge and is properly pretreated before being powder coated dvst proof complete in all respect as per specification attached Make Agni/Atasi. Make: AGNI STAR/ AGNI DEVICE (NSI) |
| 396 | Providing, fixing, testing commissioning of smoke detector having capacity, complete in all respect of make Agni/Atasi 2 wire photoelectric smoke alarm2 wire photoelectric smoke alarm with remote LED output2 wire photoelectric smoke and heat alarm2 wire photoelectric smoke and heat alarm with remote LED output4 wire photoelectric smoke alarm (24 VDC) |
| 397 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.25 mm dia nominal bore |
| 398 | 32 mm dia nominal bore |
| 399 | Providing and fixing G.I. tank nipple AVR/SVW Make complete in all respects. A) 32 mm nominal bore (NSI) |
| 400 | B) 50 mm nominal bore (NSI) |
| 401 | Providing and fixing emergency safety signage for (for Do’s & Don’ts) printed on reflective sun board laminated 3mm thickness complete in all respects to the entire satisfaction of EIC |
| 402 | Providing and fixing of angle sprinkler complete in all respect Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy