| 1 | Earth work in excavation by mechanical means (Hydraulic excavation)/manual means in foundation frenches or drains not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed with a lead of 50 m All kind of soi |
| 2 | Supplying and filling in plinth under floor foundation etc with snd fine from local quarry with all lift includingspreading in horizontal layer watering gradng to required slop ramming consolidating and compacting each layer by usingplate compactor or by any suitable method complete. |
| 3 | Providing and laying dry flat brick flooring in required pattern completed. |
| 4 | Providing and laying in position cement concrete of specified grde excluding the cost of centering and shuttering All work upto plinth level 1:3:6( 1cement:3 fine sand:6 geded well burnt brick aggregate 20 mm niminal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering shuttering finishing and reinforcement All work upto plinth level 1:1.5:3(1cement:1.5 fine sand:3 grded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspendedfloors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto floor five levelexcluding the cost of centring, shuttering, finishing andreinforcement- |
| 7 | Reinforcement for RCC work including straightening cuting bending placing in position and binding complete upto plinth level thermo-Mechanically Treated bars grade Fe 500D or more |
| 8 | First class brick work foundation and pinth including cost of all materials as required complete In cement mortr 1:4(1cement:4 fine sand) |
| 9 | Centering shuttering including struttings, propping etc.and removal of form work for:Lintels, beams, plinth beams, girders, bressumers andcantilevers with wooden plank |
| 10 | Half brick first class brick work foundation and pinth including cost of all materials as required complete In cement mortr 1:4(1cement:4 fine sand) |
| 11 | 12 mm cement plaster of mix In cement mortar 1:4(1cement:4 fine sand) |
| 12 | 12 mm cement plaster of mix In cement mortar 1:4(1cement:4 fine sand) including Neat cement punning) |
| 13 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge.. |
| 14 | Steel work in built up tubular (round,square or rectangular hollow tubes etc.) trusses etc including cutting hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with specal washer etc complete |
| 15 | Providing and fixing 1mm thick M.S. sheet door withframe of 40x40x6mm angle iron and 3mm M.S. gussetplates at the junctions and corners, & with cleats withbolts & nuts, rivets, locking arrangement, handles, hooks& eyes, pinlets including embedding in cement concreteof required grade for fixing in position, all necessaryfittings, including applying a priming coat of approvedsteel primer etc. complete as required:-Using M.S. angels 40x40x6 mm for diagonal braces. |
| 16 | Steel work in built up tubular (round,square or rectangular hollow tubes etc.) trusses etc including cutting hoisting fixing in position and applying a priming coat of approved steel primer including welding and bolted with specal washer etc complete |
| 17 | Providing and fixing plain Multipurpose Cement board(High Pressure steam cured) as per IS : 14862 :2000 with suitable screws for fibre cement board inceiling etc. complete as per direction of Engineer-incharge. (frame work to be paid separately) :6 mm thick cement board |
| 18 | Supply & Installation of pre-painted Galvalume Sheets for roofing/cladding (size,Shape and pitch of corrugation as approved by Engineer-in charge) in 550 MPA steel grade made out of cold rolled steel coted with Zinc-Aluminium alloy coating of 43% Zn 55% Al and 1.5 % silicon confirming to ASTM A792/A79m and AS 1397 Alloy coating AZ150/AZ70 colour coated with high quality polyster coating top coated of modified polyeste of 20 micron back side coat of 5 micron having epoxy pamer coat of 5 micron on both side sheet should have protective guard film of 25 micron minimum to avoid scratches whiletransportion and should be supplied in single length upto 12 meter or as desired by Engineer-in-charge the sheet shall be fixed using self drilling /self tapping screws of size(5.5 x55 mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required 0.50 mm thickness. |
| 19 | 60 mm thick factory made c.c interlocking paver block of M -30GradeCement concrete 1:2:4 in pavements, laid to required slope andcamber in panelsProviding and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block makingmachine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over andincluding 50 mm thick compacted bed of sand, filling the joints with fine sand etc. all complete as per specification and approval/ direction of the Engineer-in-charge. |
| 20 | Finishing walls with acrylic smooth exterior paint ofrequired shade of approved brand and manufacture[Payment shall be made after submission of test certified issue by the manufacture] New work two or more coats applied @1.67 lier/10 sqm over and including priming coat of exterior paimer applied @2.20 kg/10 sqm) |
| 21 | Distempering with dry distemper of approved brand andmanufacture (two or more coats) of required shade onnew work, over and including water thinnable primingcoat to give an even shade. [Payment shall be made aftersubmission of Test Certificate issued by theManufacturer] |
| 22 | Painting with synthetic enamel paint of approved brandand manufacture to give an even shade [Payment shall bemade after submission of Test Certificate issued by theManufacturer]:12.59.1 Two or more coats on new work Please Enable Macros to View BoQ information |