| 1 | Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within50 meters lead as per direction of Engineer-in-charge. |
| 2 | Demolishing brick work manually/by mechanical means includingstacking of serviceable material and disposal of unserviceablematerial within 50 meters lead as per direction of Engineer-I In cement mortar |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead For thickness of tiles upto 25 mm |
| 4 | Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) includingramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earthto be levelled and neatly dressed.All kinds of soil |
| 5 | Extra for every additional lift of 1.5 m or part thereof in.All kinds of soil. |
| 6 | Supplying and filling in plinth under floors including,watering, ramming consolidating and dressing completeCrusher Stone Dust |
| 7 | Cement concrete grade M-10 (Nominal Mix) with 40 mm maximumsize of stone aggregate |
| 8 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 9 | Centering and shuttering including strutting, propping stretching etc.complete for and removal of form work by sheet plate or ply woodshuttering for : 19.1.1 Foundations, footings, bases of columns, etc. For mass concrete |
| 10 | Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level :5.1.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate |
| 11 | Centering and shuttering including strutting, propping stretching etc.complete for and removal of form work by sheet plate or ply woodshuttering fo |
| 12 | Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level :5.1.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate |
| 13 | Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers notexceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and liftupto 1.5 m |
| 14 | Cement concrete grade M-10 (Nominal Mix) with 40 mm maximumsize of stone aggregate |
| 15 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 16 | Centering and shuttering including strutting, propping stretching etc.complete for and removal of form work by sheet plate or ply woodshuttering for : 19.1.1 Foundations, footings, bases of columns, etc. For mass concrete |
| 17 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level : Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate |
| 18 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, class designation 75 Kg/CM2(average compressive strength) insuperstructure above plinth level up to floor 2 level including the cost ofscaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 19 | Supplying and filling in plinth under floors including,watering, ramming consolidating and dressing complete. 2.18.1 Moorum/Hard copra |
| 20 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 21 | Centering and shuttering including strutting, propping stretching etc.complete for and removal of form work by sheet plate or ply woodshuttering for : 19.1.1 Foundations, footings, bases of columns, etc. For mass concrete |
| 22 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level : Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate |
| 23 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 24 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 25 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers, abutments, posts and struts etc.aboveplinth level and up to floor two level excluding cost of centering,shuttering and reinforcement etc.5.2.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate. |
| 26 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, class designation 75 Kg/CM2(average compressive strength) insuperstructure above plinth level up to floor 2 level including the cost ofscaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 27 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 28 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 29 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers, abutments, posts and struts etc.aboveplinth level and up to floor two level excluding cost of centering,shuttering and reinforcement etc.5.2.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate. |
| 30 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, class designation 75 Kg/CM2(average compressive strength) insuperstructure above plinth level up to floor 2 level including the cost ofscaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 31 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 32 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 33 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases up to floortwo level excluding the cost of centering, shuttering and reinforcementwith Cement concrete grade M-20 (Nominal Mix) with 20 mm maximumsize of stone aggregate. |
| 34 | Suspended floors, roofs, landings, balconies and access platform |
| 35 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 36 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases up to floortwo level excluding the cost of centering, shuttering and reinforcementwith Cement concrete grade M-20 (Nominal Mix) with 20 mm maximumsize of stone aggregate. |
| 37 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 sand) |
| 38 | 12 mm cement plaster of mix 1:4 (1 cement: 4 sand) |
| 39 | 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) |
| 40 | Providing and laying vitrified floor tiles (without Soluble salt) or printed(with soluble salt) Nano polished (Glossy finish) in different sizes withwater absorption less than 0.05% and conforming to IS : 15622 ofapproved make in all colours & shades, Ist quality/ premium quality inflooring laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand)including grouting the joints with white cement and matching pigmentsetc. complete. Size 600x600mm as per manufacturer specification |
| 41 | Applying one coat of cement primer of approved brand andmanufacture on wall surface : Cement primer. |
| 42 | Providing and applying 1.0 mm thick white cement based wall putty ofbest quality, over plastered surface to prepare the surface even andsmooth complete |
| 43 | Wall painting with plastic emulsion paint of approved brand andmanufacture to give an even shade: Two or more coats on new work |
| 44 | In gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works. |
| 45 | Painting Steel work with Deluxe Multi Surface Paint to give an evenshade. Two or more coat applied @0.90 ltr/10 sqm over an under coatof primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 46 | Granite of any colour and shade8.2.6.1 Area of slab upto 0.50 sqm |
| 47 | Cement concrete grade M-20 (Nominal Mix) with 20 mm maximumsize of stone aggregate |
| 48 | Point wiring including metallic switch box, sheet, switches, sockets, lampholders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR withcopper multi strand conductor ISI marked in Surface rigid P.V.C. conduit(MMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copperearth continuity conductor of green colour inside conduit includingpainting etc. as required as per specification for :-a) Short point |
| 49 | Point wiring including metallic switch box, sheet, switches, sockets, lampholders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR withcopper multi strand conductor ISI marked in Surface rigid P.V.C. conduit(MMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copperearth continuity conductor of green colour inside conduit includingpainting etc. as required as per specification for :-b) Medium point |
| 50 | Point wiring including metallic switch box, sheet, switches, sockets, lampholders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR withcopper multi strand conductor ISI marked in Surface rigid P.V.C. conduit(MMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copperearth continuity conductor of green colour inside conduit includingpainting etc. as required as per specification for :-Long point |
| 51 | 3 Pin 6 Amp socket outlet on Separate Boarda) Short point |
| 52 | 3 Pin 6 Amp socket outlet on Separate Boardb) Medium point |
| 53 | 3 Pin 6 Amp socket outlet on Separate BoardLong point |
| 54 | Point wiring including metallic switch box, sheet, switches, sockets for 3pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FRwith copper multi strand conductor ISI marked in Surface rigid P.V.C.conduit (MMS) ISI marked of suitable size and 1.5 Sq. mm. PVCinsulated copper earth continuity conductor of green colour inside conduitwith required materials as per specification on same board. |
| 55 | Circuit Wiringa) 2x2.5 Sq.mm. |
| 56 | Circuit Wiringb) 4x2.5 Sq.mm |
| 57 | Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. SocketOutlet Point With 4 Sq. mm. PVC insulated cable FR with copper multistrand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISIMarked of suitable size including painting etc. with 16 Amp. F.T. Switch &Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVCinsulated copper earth co On Separate BoardA. Short Point |
| 58 | Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. SocketOutlet Point With 4 Sq. mm. PVC insulated cable FR with copper multistrand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISIMarked of suitable size including painting etc. with 16 Amp. F.T. Switch &Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVCinsulated copper earth co On Separate BoardB. Medium Point |
| 59 | Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. SocketOutlet Point With 4 Sq. mm. PVC insulated cable FR with copper multistrand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISIMarked of suitable size including painting etc. with 16 Amp. F.T. Switch &Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVCinsulated copper earth co On Separate Board C. Long Point |
| 60 | Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. SocketOutlet Point With 4 Sq. mm. PVC insulated cable FR with copper multistrand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISIMarked of suitable size including painting etc. with 16 Amp. F.T. Switch &Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVCinsulated copper earth co On Separate BoardD. Extra Long -I |
| 61 | Supplying,Fixing and Testing of Compact Flourescent Lamp (CFL) withinbuilt electronic ballast ISI marked of approved make as required as perspecification20 Watt |
| 62 | Supplying,Fixing and Testing of Compact Flourescent Lamp (CFL) withinbuilt electronic ballast ISI marked of approved make as required as perspecification25 Watt |
| 63 | Suppling and fixing of approved make step type electronic Fan regulatorincluding connection etc. as required on existing board |
| 64 | Supplying, erection and testing of approved make electric Ceiling fan ofdouble ball bearing complete with standard down rod, canopy, hangingshackle, Aluminium blades, without regulator, A.C. 230-250 volts includingconnections with all necessary material complete as required confirming toIS :374/1979 with upto date ammendments. Ceiling Fan (Energy Saver 60 W)-1400 mm Sweep |
| 65 | Supplying, erection and testing of approved make Wall Mounting fan complete with Wall Bracket ,canopy, blades, speed Regulator etc .A.C 230- 250 volts with connections and including raw bolt/Anchor hole fastener etc. complete finished and as required.400 sweep |
| 66 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3ply veneering with vertical grains or cross bands and face veneers on both faces of shutters using following hinges.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 67 | Extra for Providing and fixing flush doors with decorative veneeringinstead of non decorative ISI marked flush door shutters to IS : 2202Part-1 on one side only. |
| 68 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area ofdoor shutter to be measured). |
| 69 | Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holesfor rawl plug etc. including priming coat complete with Hard wood. |
| 70 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class teak wood |
| 71 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 72 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 73 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers, abutments, posts and struts etc.aboveplinth level and up to floor two level excluding cost of centering,shuttering and reinforcement etc.5.2.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate. |
| 74 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, class designation 75 Kg/CM2(average compressive strength) insuperstructure above plinth level up to floor 2 level including the cost ofscaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 75 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 76 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 77 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers, abutments, posts and struts etc.aboveplinth level and up to floor two level excluding cost of centering,shuttering and reinforcement etc.5.2.1 Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum sizeof stone aggregate. |
| 78 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, class designation 75 Kg/CM2(average compressive strength) insuperstructure above plinth level up to floor 2 level including the cost ofscaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 79 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 80 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 81 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases up to floortwo level excluding the cost of centering, shuttering and reinforcementwith Cement concrete grade M-20 (Nominal Mix) with 20 mm maximumsize of stone aggregate. |
| 82 | Suspended floors, roofs, landings, balconies and access platform |
| 83 | Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding upto floor level including costof binding wire, wastage and over laps upto 12mm horizontal/ inclinedposition of reinforcement bars in slab and beams, plinth, chajjas,lintels, upto 4.5m vertical length of reinforcement in wall columns (overlaps shall be provided as per requirement of IS : 13920; IS 456 & SP :34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more) |
| 84 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases up to floortwo level excluding the cost of centering, shuttering and reinforcementwith Cement concrete grade M-20 (Nominal Mix) with 20 mm maximumsize of stone aggregate. |
| 85 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 sand) |
| 86 | 12 mm cement plaster of mix 1:4 (1 cement: 4 sand) |
| 87 | 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) |
| 88 | Providing and laying vitrified floor tiles (without Soluble salt) or printed(with soluble salt) Nano polished (Glossy finish) in different sizes withwater absorption less than 0.05% and conforming to IS : 15622 ofapproved make in all colours & shades, Ist quality/ premium quality inflooring laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand)including grouting the joints with white cement and matching pigmentsetc. complete. Size 600x600mm as per manufacturer specification |
| 89 | Applying one coat of cement primer of approved brand andmanufacture on wall surface : Cement primer. |
| 90 | Providing and applying 1.0 mm thick white cement based wall putty ofbest quality, over plastered surface to prepare the surface even andsmooth complete |
| 91 | Wall painting with plastic emulsion paint of approved brand andmanufacture to give an even shade: Two or more coats on new work |
| 92 | In gratings, frames, guard bar, ladder, railings, brackets, gatesand similar works. |
| 93 | Painting Steel work with Deluxe Multi Surface Paint to give an evenshade. Two or more coat applied @0.90 ltr/10 sqm over an under coatof primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 94 | Granite of any colour and shade8.2.6.1 Area of slab upto 0.50 sqm |
| 95 | Cement concrete grade M-20 (Nominal Mix) with 20 mm maximumsize of stone aggregate |
| 96 | Point Wiring in surface rigid P.V.C. conduit system with Flush type AccessoriesLight Point/Fan Points. a) Short point |
| 97 | Point Wiring in surface rigid P.V.C. conduit system with Flush type AccessoriesLight Point/Fan Points. b) Medium point |
| 98 | Point Wiring in surface rigid P.V.C. conduit system with Flush type AccessoriesLight Point/Fan Points. Long point |
| 99 | 3 Pin 6 Amp socket outlet on Separate Boarda) Short point |
| 100 | 3 Pin 6 Amp socket outlet on Separate Boardb) Medium point |
| 101 | 3 Pin 6 Amp socket outlet on Separate BoardLong point |
| 102 | Point wiring including metallic switch box, sheet, switches, sockets for 3pin 6 Amp. Socket outlet point with 1.5 Sq. mm. PVC insulated cable FRwith copper multi strand conductor ISI marked in Surface rigid P.V.C.conduit (MMS) ISI marked of suitable size and 1.5 Sq. mm. PVCinsulated copper earth continuity conductor of green colour inside conduitwith required materials as per specification on same board. |
| 103 | Circuit Wiring a) 2x2.5 Sq.mm. |
| 104 | Circuit Wiring b) 4x2.5 Sq.mm |
| 105 | POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY)SYSTEM WITH MODULAR ACCESSORIESOn Separate Board A. Short Point |
| 106 | POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY)SYSTEM WITH MODULAR ACCESSORIESOn Separate BoardB. Medium Point |
| 107 | POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY)SYSTEM WITH MODULAR ACCESSORIESOn Separate BoardC. Long Point |
| 108 | POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY)SYSTEM WITH MODULAR ACCESSORIESOn Separate BoardD. Extra Long -I |
| 109 | Supplying,Fixing and Testing of Compact Flourescent Lamp (CFL) withinbuilt electronic ballast ISI marked of approved make as required as perspecification20 Watt |
| 110 | Supplying,Fixing and Testing of Compact Flourescent Lamp (CFL) withinbuilt electronic ballast ISI marked of approved make as required as perspecification25 Watt |
| 111 | Suppling and fixing of approved make step type electronic Fan regulatorincluding connection etc. as required on existing board |
| 112 | Supplying, erection and testing of approved make electric Ceiling fan ofdouble ball bearing complete with standard down rod, canopy, hangingshackle, Aluminium blades, without regulator, A.C. 230-250 volts includingconnections with all necessary material complete as required confirming toIS :374/1979 with upto date ammendments.Ceiling Fan (Energy Saver 60 W)-1400 mm Sweep |
| 113 | Supplying, erection and testing of approved make Wall Mounting fan complete with Wall Bracket ,canopy, blades, speed Regulator etc .A.C 230- 250 volts with connections and including raw bolt/Anchor hole fastener etc. complete finished and as required. 400 sweep |
| 114 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3ply veneering with vertical grains or cross bands and face veneers on both faces of shutters using following hinges. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 115 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters to IS : 2202 Part-1 on one side only. |
| 116 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area ofdoor shutter to be measured). |
| 117 | Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holesfor rawl plug etc. including priming coat complete with Hard wood. |
| 118 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class teak wood |
| 119 | Chequered terrazo tiles 18-20mm thick with graded marble chips of sizeup to 6 mm in floors jointed with neat cement slurry mixed with pigment tomatch the shade of the tiles including rubbing and polishing complete on20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade using white cement. Please Enable Macros to View BoQ information |