| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L Light shade Vitrified double charge Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over including 15 mm th screed bed CM (1:6) and poined in white or colour cement to match complete all as specified & directed by Engr-In-Charge. |
| 3 | S&F Premium quality glazed ceramic tile of size 450mm x 300mm thickness 7mm, water absorption between 10% to 20% pasted with spacer, tile adhesive and epoxy grouted with same make as of tile Make Glosstra series of Somany or equivalent in Johnson/Kajaria over including 15 mm thick rendereing CM (1:4) and poined in white or colour cement to match complete all as specified and directed by Engr-in-Charge. |
| 4 | S&F Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, (400 X400 mm) as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles15mm thick screed bed or bedding layer CM 1:4 for laying finishes,complete all as specified as directed by Engr-in- Charge. |
| 5 | Dismantling stone slabs of any description or thickness in floors, apron etc laid bedded and pointed in any mortar complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L Granite (of any type) work 15 to 17 mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-Charge. |
| 7 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L, Machine cut kota stone slab flooring, cills 20-25mm thick over cement screed base laid and jointed With grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.(single piece of Kota stone to be fixed in stair treads) complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L, Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick rendering 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (single piece of Kota stone to be fixed in stair risers) complete all as specified and directed by Engr-in-Charge. |
| 10 | Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed by Engr-in-Charge. |
| 11 | Water proofing treatment to sunken slab and adjjoining vertical surfaces as specified under :-(a) Cleaning of sunen portion and roughining to receive treatment.(b) M&L rendering 10 mm thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compound trowel even and smooth with steel trowel on sunken surfaces (Note : WPC shall be measured and paid separately)(c) Applying first coat of chemical pidifin 2K(Dr Fixit) on cleared RCC surfaces @ 0.86 Kg/Sqm (Minimum) as recommended by manufacturer.(d) Provide a layer glass fibre mesh of size 2.25mm x2.25mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturers recommendation.(e) Applying second coat of chemical Pidifin 2K (Dr Fixit) / eqivalent @ 0.86 Kg/Sqm (minimum) layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturers.Note: The plan area of floor shall be considered for payment. |
| 12 | M&L for PCC 1:5:10, type E-2 as in filling of sunken floors etc complete all as specified and directed by Engr-in-Charge. |
| 13 | M&L 25mm thick PCC 1:2:4 type B0 (12.5mm graded aggregate) with WPC under floor over sunken complete all as specified and directedNote : WPC will be measured and paid separately. (WPC will conforms to IS: 2645-2003) |
| 14 | M&L 40 mm GI pipe medium grade, made to shape as in spout pipe in sunken/ verandah/ Balcony complete all as specified and directed by Engr-in-Charge. |
| 15 | M & L for PCC (1:3:6) type C-2 (using 40mm graded agg) 75mm thick as in plinth protection including making grooves complete all as specified and directed by Engr-in-Charge. |
| 16 | Demolition of RCC of any descrition such chajja, shelves etc and in any position not other wise specially provided for complete all as specified and directed by Engineer in Charge (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for reinforced cement concrete type B1 1:2:4 (20 mm graged aggregate) as in Slab supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and etc. and setting in mortar complete with joints to match complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge. |
| 19 | Use and waste of form work torough finished surfaces of soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick complete all as specified and directed by Engr-in-Charge. |
| 20 | Taking up or down GI/CPVC tubing of inner dia 15mm & removal to store complete all as specified and directed by Engineer-in-charge. |
| 21 | Taking up or down GI/CPVC tubing of inner dia 20mm & removal to store complete all as specified and directed by Engineer-in-charge. |
| 22 | Supplying and laying of 20 mm (outer dia) (15mm inner dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 bend fittings on walls/ceiling or laying in floors & including CPVC coated brass elbow,T, Male/ Female Brass Threaded adaptor etc. complete all as specified and as directed by Engineer-in-Charge. |
| 23 | Supplying and laying of 25 mm (outer dia) (20mm inner dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 bend fittings on walls/ceiling or laying in floors & including CPVC coated brass elbow,T, Male/ Female Brass Threaded adaptor etc. complete all as specified and as directed by Engineer-in-Charge. |
| 24 | S&F in repair Rotational moulded polythylene 500 capacity water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position including 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. & dismantling of old water tank complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F in repairs 20mm gun metal globe or gate valve with iron wheet head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F in repair 15 mm dia bore fancy type chromium plated long body bib taps cast copper alloy with on/off handle, screwed down, screwed for iron pipe, or for brass ferrule complete all as specified and directed by Engr-in-Charge. |
| 27 | S &F in repairs Central hole single lever mixer with 450mm braided connection pipe cast copper alloy chromium plated fancy type 15 mm bore complete all as specified and directed by Engr-in-Charge. |
| 28 | S &F in repairs cromium plated wall mixer with long bend pipe for overhead shower fancy type 15 mm bore complete all as specified and directed by Engr-in-Charge. |
| 29 | S & F in repair 15 mm bore chromium plated Angular stop valve of cast copper alloy screwed down high pressure with on/off handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge. |
| 30 | S & F PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality complete all as specified and directed by Engr-in-Charge. |
| 31 | S&F in repair vitreous china wash basins, size 550x400mm white flat back with full pedestal including 32mm waste fittings, waste pipe, chromium plated with long screwed shanks & fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engr-in-Charge. |
| 32 | S & F in repairs vitreous China squatting pan of Orrissa pattern of approved make of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor complete all as specified and directed by Engr-in-Charge. |
| 33 | S & F in repairs vitreous China one piece wall hung EWC with soft close seat cover, hinges, accessories set size 640x360x765 mm white colour complete including flushing cistern with hanging arrangement complete all as specified and directed by Engr-in-charge. |
| 34 | S & F PVC low level cistern of 10 ltrs capacity with top push buttion inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle complete of approved make complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F in repair brass chromium plated shower rose 125 mm of size with arm and with or without swivel joints to steel pipe or union complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F in repair 600mm x 450mm bevelled edge mirror 6mm thick of selected quality glass mounted fixed to wall with SS spacer 25mm size complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F in repair brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed by Engr-in-Charge. |
| 38 | S & F Towel Ring of stainless steel fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engr-in-Charge. |
| 39 | S&F stainless steel soap tray any type and fixed to plugs on wall with chromium plated brass screws complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F Stainless steel fancy type peg set of six and fixed in position with steel screws complete all as specified and directed by Engr-in-Charge. |
| 41 | Dismantling and disconnecting existing CI / PVC soil waste/vent pipe 100/75 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and directed by Engr-in-Charge. |
| 42 | Supply & fixing 110mm bore uPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls/tranches with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant including bends, socket , Y junction, Tee , cowl etc complete all as specified and as directed by Engineer-in- charge complete including low carbon hot roll gauge corrected oil pickled & drawn pipe supporting clamping system 32x3mm with rib and notch are hot dip galvanised and Zn, Al flake coating with necessary clamps to fix and hold pipe complete all as specified and directed. Note: Detail of Pipe supporting system is all as per Drg NO -BTD-916). Note:-UPVC PIPE AND FITTING / FIXTURE- (i) The testing for leakage of pipe shall be done before connecting the pipes (ii) All pipes shall be minimum 4\\" away from walls fixed with GI bracket (iii) The gully trap shall be minim um 90 cm away from wall.(iv) Separate pipes for each floor should be provided (v) Sewage and drain system shall be separate. |
| 43 | Supply & fixing 75mm bore uPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls/tranches with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant complete including bends, socket , Y junction, Tee , cowl etc all as specified and as directed by Engineer-in- charge complete including low carbon hot roll gauge corrected oil pickled & drawn pipe supporting clamping system 32x3mm with rib and notch are hot dip galvanised and Zn, Al flake coating with necessary clamps to fix and hold pipe complete all as specified and directed. Note: Detail of Pipe supporting system is all as per Drg NO -BTD-916) Note:-UPVC PIPE AND FITTING/ FIXTURE- (i) The testing for leakage of pipe shall be done before connecting the pipes (ii) All pipes shall be minimum 4\\" away from walls fixed with GI bracket (iii) The gully trap shall be minim um 90 cm away from wall. (iv) Separate pipes for each floor should be provided (v) Sewage and drain system shall be separate |
| 44 | S & F 110 mm bore uPVC pipes grade 'B' bends / Elbow heavy grade of any radius / shoe with or without access door fixed to uPVC pipes complete all as specified and directed by Engr-in-Charge. |
| 45 | S & F 75 mm bore uPVC pipes grade 'B' bends / Elbow heavy grade of any radius / shoe with or without access door fixed to uPVC pipes complete all as specified and directed by Engr-in-Charge. |
| 46 | M&L for uPVC (SWR) 'P’ trap 110mm dia grade 'B' complete all as specified and directed by Engr-in-Charge. |
| 47 | S&F for 75mm dia of long body uPVC Floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1 in repair complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F uPVC pipes grade 'B' branch piece,single (single Y),75 mm bore, (equal or unqual), with or without access door complete all as specified and directed by Engineer-in-Charge. |
| 49 | S&F uPVC pipes grade 'B' branch piece,single (single Y),100 mm bore, (equal or unqual), with or without access door complete all as specified and directed by Engineer-in-Charge. |
| 50 | M&L uPVC pipes grade 'B' junction single,(Single T), 75 mm bore, (equal or unqual), ordinary or inverted (spigot or socket type) or with or without oval acess door as in repairs complete all as specified and directed by Engineer-in-Charge. |
| 51 | M&L uPVC pipes grade 'B' junction single,(Single T), 100 mm bore, (equal or unqual), ordinary or inverted (spigot or socket type) or with or without oval acess door as in repairs complete all as specified and directed by Engineer-in-Charge. |
| 52 | S&F in repairs uPVC pipes grade 'B' vent cowl 100 mm complete all as specified and directed by Engr-in-Charge. |
| 53 | S&F Salt-glazed stoneware gully traps 150x 150 mm , square or round mouthed, type 'P complete all as specified and directed by Engr-in-Charge. |
| 54 | Taking down cement plaster from ceilings & brick walls including any type of any description, racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed by Engr-In-Charge. |
| 55 | M&L for rendering 15mm thick in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smoothe without using extra cement & with using integral water proofing compound complete all as specified and directed by Engr-in-Charge.Note : WPC shall be measured and paid for separately. |
| 56 | M&L rendering 10 mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed by Engr-In-Charge. |
| 57 | M&L for rendering 5mm thick in cement mortar in 1:3 on ceiling complete all as specified and directed by Engr-in-Charge. |
| 58 | Supply only liquid water proofing compound complete all as specified and directed by Engr-in-Charge. |
| 59 | M&L preparation of newly plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion white/tinted over two coat of wall care putty (1.5mm thick each coat) finished even and smooth surface by hand roller complete all as specified and directed by Engr -in - charge. |
| 60 | M&L for complete removal of existing treatment of old decorated surfaces of wall by mechanical sander/ brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and filling in depressions to make smooth surface and applying two coat of distemper oil emulsion white/tinted using hand roller complete over two coat of wall care putty complete all as specified and directed by Engr-in-Charge. |
| 61 | M&L preparation of newly plastered or unplastered surfaces of ceiling and applying two coat of distemper oil emulsion white/tinted over coat of wall care putty finished even and smooth surface by hand roller complete all as specified and directed by Engr -in - charge. |
| 62 | M&L for complete removal of existing treatment of old decorated surfaces of ceiling by mechanical sander/ brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and filling in depressions to make smooth surface and applying two coat of distemper oil emulsion white/tinted over coat of wall care putty finished even and smooth surface by hand roller complete all as specified and directed by Engr -in - charge. |
| 63 | M&L preparation of newly plastered or unplastered surfaces of wall, soffits/ facia of chajja/ roof slab for applying Two coat of Acrylic Smooth exterior paint of required shade over and including one coat of of exterior primer and one coat of exterior wall care putty complete all as specified and directed by Engr-in-Charge. |
| 64 | M&L for complete removal of existing treatment of old decorated surfaces of wall by mechanical sander/ brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots including filling depression of scraped surface with wall putty two coats 1.5 mm thick each and Finishing walls with Two coat of Acrylic Smooth exterior paint of required shade over and including one coat of of exterior primer complete all as specified and directed by Engr-in-Charge. |
| 65 | M&L for Acrylic polymer base damp-proof coating system with two component ready to use acrilyic ploymer modified damp-proof coating :1. SURFACE PREPARATION: Remove the existing plastered surface with efflorescence/ seepage area. Non-moving cracks having width upto 5 mm must be filled with Polymer based crack filler.2 APPLICATION: Apply acrylic polymer base damp proof coating by brush roller over SSD surface. Apply the first coat of damp proof coating with a paintbrush directly on the surfaces. Allow to dry for a minimum 2-3 hrs. Apply subsequent second layer after drying. The first coat and second coat must be applied in perpedicular direction. The coverage must be atleast 1.2 sqm/kg/coat. The mixing for two component, if required, shall be done as per manufactures specifications. Rendering to be carried out after approval of Eng in charge and shall be paid seprately.Make : Asian Paints Damp proof Ultra 2K/Fosroc Damp Protect/Dr Fixit dampguardNote : Treatment shall be carried out through Authorized applicators only |
| 66 | Dismantling of brickwork built in cement mortar of any description complete all as specified and directed as per Engineer-In-Charge |
| 67 | M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc.complete all as specified and directed by Engineer - in - Charge. |
| 68 | Dismantling of stone slab and tiles in any description in aprons and floors and removal from the site to a distance n.exc 500 metres complete all as specified and directed by Engr-in-Charge. |
| 69 | M&L 100 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) in sub base, floors etc complete all as specified and directed by Engr-in-Charge. |
| 70 | M&L for Machine pressed Precast cement concrete interlocking coloured ( glossy finished / ruberised paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade with and including 40mm thick sand cushining complete all as specified and directed by Engr-in-charge. |
| 71 | Taking down chowkats or frames exc 1.5 sqm but not exc 4.00 Sqm each with shutters (without taking of shutters from the frames) incl making good disturbed surfaces of wall matching adjoining wall finish and removing taken down material from site complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 72 | Taking down chowkats or frames exc 1.5 sqm but not exc 4.00 Sqm each with shutters (without taking of shutters from the frames) incl making good disturbed surfaces of wall matching adjoining wall finish and removing taken down material from site complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |