| Sl. No. | Item Description |
| 1 | Sch 'A' Part-I B/R Portion:-Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc including demolition of precast rcc articles and disposal of debris out of MoD land complete all as specified and directed. |
| 2 | M&L for Brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 3 | All as per item No 02 here-in before but except bricks.NOTE: Old burnt clay bricks retrieved from demolition shall be used. |
| 4 | M&L for Brickwork with fly ash old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 5 | Demolition of cement concrete or lime concrete (unreinforced) in ground floors and Pavings not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed . |
| 6 | M&L for hard core of broken stones or boulders of gauge not exc 63mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed |
| 7 | M&L for PCC in foundations, filling and mass-concrete type D-2 (1:4:8) using 40 mm graded crushed stone aggregate complete all as specified and directed. |
| 8 | M&L for cement concrete type C-1 1:3:6 (using 20mm graded crushed stone agg) as in plinth protection and paving 75mm thick laid in slope finished even and fair without using extra cement incl making joints every 2.5m and corner filled with bitumen 85/25 complete all as specified. |
| 9 | M&L for 25mm thick Cement concrete in sub base for receiving floor tiles and mass concrete using Type B-1,1:2:4 (using 20 mm graded crushed stone aggregate) complete all as specified and directed.Note:- Finishing surfaces of concrete to be even and rough to receive the topping layer or floor tiles etc |
| 10 | M&L for PCC 1:2:4, type B-0, (using 12.5 mm graded crushed stone aggregate) mixed with water proofing compound as per manufacturer’s instructions as in padding on roof, surface finished even and smooth without using extra cement all as specified and as directed.(Note:- WPC shall be measured and paid separately) |
| 11 | M&L for Plain Cement concrete 1:5:10 Type E2 using 40mm graded crushed stone aggregate as in filling of sunken floor to receive floor top finished complete all as specified and directed. |
| 12 | M&L for liquid water proofing treatment to RCC roof slab including dismantling of existing roof treatment of any derscription such as worn-out tar felt, debris, mortar of any description & any thickness, surface cleaning of all foreign material such as shrubs / roots, fungus, moss, dust including plaster, APP membrane etc. including disposal of debris out of MoD land, in following procedure :(a) Prepare the surface by cleaning with concrete surface grinder / wire brushand a high pressure water jet and ensure that it is free of dust, oil and loose particles. Damaged portions, hollow area must be repaired with epoxy mortar and repair crack old concrete by cutting 'V' groove, corners and joints of drain pipes, channels etc. treated with epoxy mortar prepared with epoxy primer (as per manufacturer's instructions).(b) Laying 10mm thick rendering in CM 1:3 mixed with WPC 3% by weight of cement on fair faces of concrete roof surfaces, finished even and fair to receive treatment on roof complete.(c) Applying 03 coats of PU Hybrid waterproof coating including priming agent in first coat as per manufacturer's instructions having elongation (strech ability) at break of free film of approx 350% - 400% tensile strength at 14 days of 2.90 MPa and surface reflectance index of 100-110.(d) The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-Charge / Consultant. (Note:- minimum 6 hrs interval between two coat shall be maintained)(e) All auxiliary and accessories involved during application should be supplied by single manufacturer as a part of system.Notes:- (i) Work to be carried out by authorized applicator and as per manufactuer's instructions.(ii) Ponding test will be carrried out with filling of water for continous 48 hours and if there is any leakage than entire treatment will be done again by contractor without any additional cost.(iii) The rate includes for filling cracks in existing roof with epoxy cement mortar using suitable bonding agent before laying cement plaster. |
| 13 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises and removing the debris outside from defence land complete all as specified and directed . |
| 14 | M&L for 20mm thick granite (pure black) work (table rubbed and polished) in steps, jambs pillars, window cills ,cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade or granite over including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc complete all as specified and directed.Note:- The stone slab shall be in one piece over kitchen plateform,window cill and making gas pipe holes 25mm dia with rounded holes and all open edges to be half rounded. |
| 15 | M&L for coloured Glazed ceramic tiles in vertical surface such as dado etc 450mmX 350mmX 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete all as specified and as directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE |
| 16 | S&F joint free non skid coloured Ceramic tiles 07mm to 08mm thick (square/ rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. |
| 17 | S&F joint free non skid coloured Ceramic tiles 07-08 mm thick (square/ rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. |
| 18 | S&F joint free non skid Ceramic tiles, coloured 7mm to 8mm thick (square/ rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm in vertical/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat/redering in cement mortar 1:4 for fixing of tiles complete all as specified and as directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE |
| 19 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.& Brushing neat cement slurry with 3.0kg of cement per sqmetre complete all as specified and directed. |
| 20 | M&L for non abrasive paving (endura) tiles 300mm x 300mm x10mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15mm screed bed CM 1:4 to match complete al as specified and directed. Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE |
| 21 | Demolition of Roofs, floors (other than ground floors), beams staircases, landing, cooking platform ,chajjas, & similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition) and disposal of debris out of MoD land complete all as specified and directed.Note:- Demolition will be done only by mechanical cutter only . |
| 22 | M&L for RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves complete all as specified and as directed. Note:- Reinforcement shall be measured and paid separately). |
| 23 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat complete all as specified and as directed |
| 24 | M&L for Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and as directed. |
| 25 | Taking down cement plaster of any description and thickness on walls/ceilings etc including racking out joints, hacking for key, scrubbing down with water etc including necessary scaffolding up to four storeys height of bldgs if required and removing of debris out of MoD land complete all as specified and as directed. |
| 26 | M&L for rendering 15mm thick in CM 1:4 mixed with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of brick work ,concrete surface of wall, fin, facia, chajjas, parapet and similar article finished surface even and smooth without using extra cement including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed.(Note:- WPC shall be measured and paid separately) |
| 27 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work ,concrete surface of wall, finished surface even and smooth without using extra cement complete all as specified and as directed. |
| 28 | M&L for preparation of newly plastered external surfaces of wall and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade @ 1.43 litre/ 10 sqm area over and including priming coat of exterior primer applied @ 2.20 litre/ 10 sqm (weather proof/weather coat) including 1.5mm thick wall care putty without any brush marks on the surface, Shade/colour shall be approved by GE, all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed. |
| 29 | M&L for complete removal of existing treatment surface externally of wall and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade @ 1.43 litre/ 10 sqm area over and including priming coat of exterior primer applied @ 2.20 litre/ 10 sqm (weather proof/weather coat) including 1.5mm thick wall care putty without any brush marks on the surface, Shade/colour shall be approved by GE, all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed. |
| 30 | M&L for rendering 15 mm thick in cm 1:6 on other than fair faces of brick work , concrete surfaces of wall,finishing surfaces even and smooth without using extra cement including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed. |
| 31 | M&L for preparation of newly plastered internally surfaces of wall and applying min 1.5 mm thick wall care putty on the surfaces & making the surface absolutely smooth surface and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion finished without any brush marks on the surface in any colour including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed. |
| 32 | M&L for complete removal of existing treatment internally surface of wall and applying min 1.5 mm thick wall care putty on the surfaces and making surface absolutely smooth and applying one coat of primer (as per manufacturer’s recommendations) on the surfaces and applying two coats of distemper oil emulsion without any brush marks on the surface in any tint including necessary scaffolding up to four storeys height of bldgs if required ,Shade/colour shall be approved by GE,complete all as specified and as directed. |
| 33 | M&L for Rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and as directed. |
| 34 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash without any brush marks on the surface including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed. |
| 35 | M&L for complete removal of existing treatment from ceiling surface and applying three coat of white wash on undecorated surfaces without any brush marks on the surface including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed. |
| 36 | M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified & directed. |
| 37 | M&L for Washing, rubbing down and stopping of distempered and painted surfaces of wall and applying three coat white wash evenly complete all as specified. |
| 38 | M&L for preparation of old painted steel and iron surfaces of any description over 10 centimeter width or girth and applying one coat of synthetic enamel paint in any colour finished without brush mark on surface including necessary scaffolding complete all as specified and as directed. |
| 39 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer all as specified and directed. |
| 40 | M&L for writing letters or figures (block, Roman, Italic or Indian) exceeding 15 centimeter high but not exceeding 30 centimeter high etc with synthetic enamel paint including necessary scaffolding up to four storeys height of bldgs if requiredcomplete all as specified and as directed. |
| 41 | M&L for cutting down plants / trees of girth not exc 15 cm & surface are not exc 0.36 Sqm each from roof tops /sides of external walls of buildings, chajja, wall junctions, junctions of of rain water / soil /waste vent pipes including taking out roots entered in wall/slab surfaces and making good the surfaces including repairing the CI/GI/PVC joints of affected locations by applying TUFALO (herbal medicine )and making good to suit the adjoining surfaces using PCC type 1:2:4, type B-O or cement mortar 1:2 complete all as per manufacturer instructions and as specified. NOTE: Any CI/GI/PVC pipes and fittings damaged during work shall be replaced by new one to insure leakage / seepage free joint without any extra cost to the department and Unit rate quoted by tenderer shall included for use of all scaffolding, trestles, ladders, cradles etc ,hoisting, lowering and protective measures etc up to four storeys height of bldgs and removing of debris out of MoD land complete all as specified and as directed. |
| 42 | Supply only `Liquid Water Proofing Compound. complete all as specified and as directed . |
| 43 | Taking down chowkhats or frames exc 1.50 and n.exc 4 Sqm each (without talking off shutters from the freme) complete all as specified and directed. |
| 44 | Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site. |
| 45 | Taking down shutters of any description exc 1 sqm but not exc 2 sqm each and removing from site complete all as specified and directed. |
| 46 | Taking down shutters of any description exc 1 sqm and n exc 2 sqm and refixing in same opening after easing, adjusting and replacement of minor nails etc, complete all as specified and directed. |
| 47 | S&F pressed steel frames door 105 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed |
| 48 | S&F pressed steel frames door 165 x 60 x1.25 mm with one or more rebates including necessary fixing lugs/hold fast duly tarred with bitumen and sanding with sharp clean sand, hinges, lock strike plate including one shop coat of primer complete all as spd and directed |
| 49 | M&L for cement concrete type C-0, 1:3:6 using 12.5 mm graded crushed stone aggregate as in back filling of hollow portion of frame with plain cement concrete and for fixing of hold fast complete all as specified and directed. |
| 50 | S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, confirming to IS- 2202(Part-I-1999) , ISI Marked complete all as specified and directed |
| 51 | S&F 35mm thick factory made 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats Note: wire cloth shall be measured separately |
| 52 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified and directed. |
| 53 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified. |
| 54 | M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified. |
| 55 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet & edges will be painted to match with printed sheet ,reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 56 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC sheet PVC ‘C’ channel having a plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 57 | S&F Steel window/ventilator factory made, made out of mild steel box type and shutter suitable for double shutter i.e. Glazed and gauged shutter. Glazed shutter made out of hollow' section with sash bar and gauged shutter made out of hollow section without sash bar including hinges, tower bolt, handle, grill 10 mm sq bar including two coat of synthetic enamel paint over one coat of red oxide primer, tarred hold fasts, PCC bed blocks for fixing hold fast , including plain/figured glass and wire mesh complete all as per details shown in drawing No CEPZ/TD-245/01 sheet No 1/1 and CEPZ/TD-246/01 sheet No 1/2 & 2/2 including taking down existing window/ventilator any type complete all as specified and directed |
| 58 | S&F 2nd class Hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, S&F complete all as specified and directed. |
| 59 | M&L for 18 to 20 mm thick PVC prelaminated solid board with one side decorative choice laminate and other side balancing white including 3mm thick lipping and equal to thickness of board as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work etc complete all as specified and directed. |
| 60 | S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed. |
| 61 | S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass, polished complete all as specified and directed |
| 62 | S&F hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws, Size of hasp and staple in mm 100 complete all as specified and directed. |
| 63 | S&F Continuous (piano) hinges 30mm Width of flaps (when open) ,mild steel, bright finish or electrogalvanised complete all as specified and directed |
| 64 | S&F stainless steel butt hinges of size 100mm long for fixing of pvc door shutter etc complete all as specified and directed. |
| 65 | S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 150mm complete all as specified and directed |
| 66 | S&F Aluminium handles, cast type, anodised Size of handle in 150mm complete all as specified and directed. |
| 67 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed Length of bolt in 250 mm complete all as specified. |
| 68 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor Overall length of cover plate 140mm complete all as specified and directed. |
| 69 | S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate including welding to steel frames.complete. |
| 70 | S&F in repair 25mm outer dia stainless steel decorative drapery rod ( Model No- SS-25FL of Vista) of thickness 20 gauge and for every 01 RM length, provide 10 numbers stainless steel wings (Model No:- SS CRNG of Vista) with 50 mm dia and proportionate for part there off, with stainless steel brackets ( Model:- SS 25 BR, Vista) near to ends with stainless steel finials ( Model:- SS-1 of Vista with adapter) for 25mm dia drapery rod at both ends. The drapery rod shall be projecting 150 mm outer side from the clesr opening of doors/windows. ( Including necessary fittings) |
| 71 | S&F peg set of 4, brass chromium plated, fancy type, superior quality and fixed with screws complete all as specified and directed. |
| 72 | S&F brass door magic eye: as given specification material resin lens +zinc alloy,top diameter: 31.2mm, botom diameter approx 24mm, pipe diameter approx 16mm total length approx 50mm, inner height approx 36mm application 35 to 60mm thick viewing angle 200 degree of surrounding without opening the door unique design ultra clear view and superior finish, wide angle best in class lens for all round visibility the outsider cannot hide any ware, the back cover protects you from the outsider observing any movements inside easy to instal with inbuilt screw over a wide range of door thickness from 35 mm to 60mm etc required at site complete as directed by Engr-in-charge |
| 73 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads and fixed complete all as specified and directed. |
| 74 | S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square of any size pane and fixed complete all as specified and directed. |
| 75 | All as per serial item No 74 here-in-before but frosted glass complete all as specified and directed. |
| 76 | Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 77 | S&F 15mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 78 | Fixing only 15mm bore old Steel water tubing including all new galvanized fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings) |
| 79 | Taking up or down 20mm bore, steel tubing and connection including cleaning for refixing or removal from site complete all as specified and directed. |
| 80 | S&F 20mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 81 | Fixing only 20mm bore old Steel water tubing including all new galvanized fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. Note: - Old Steel water tube/pipe any type retrieved from taking down shall be used along with all new GI fittings) |
| 82 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed. |
| 83 | S&F in repair Gun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe |
| 84 | S&F in repair Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe |
| 85 | S&F Rotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old brocken water tanks, outlet & over flow pipe etc complete all as specified and as directed. |
| 86 | S&F in repair Ball valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (min. weight 20mm-210 gms) |
| 87 | S&F in repair 15 mm bore long body CP Bib taps cast copper alloy fancy type with capstan heads (chromium plated),and cup screwed down , high pressure for iron pipe mpete all as spd & directed. |
| 88 | S&F in repair 15 mm bore Stop valves, fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 89 | S&F in repair stop valves (ISI marked), 15mm dia, cast copper alloy,chromium plated fancy type with long shank and cup (concealed type) screwd down,high pressure with crutch or butter fly handle,screwed both ends for iron pipes or for unions and fixed in pipe all as specified and directed. |
| 90 | S&F for in repairs CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shankS&Fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 91 | S&F in repairs Brass CP shower rose 125mm size including fixing to steel pipe or union complete all as specified and directed. |
| 92 | S&F in repair CP brass towel ring 20mm dia, fancy type, superior quality, fixed with and including chromium plated screws and wooden/plastic cleats complete all as specified and directed. Make : ACN-CHR-1121BN of JAQUAR or equivalent in any of the make mentioned in list of products. |
| 93 | S&F in repair Tubular towel rail, ISI marked 60cm long between flanges , 20mm dia 'D' type Brass Chromium plated incl brackets, fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 94 | S&F in repair PVC Coloured bathroom cabinet looking mirror divided into shelf overall size 622mm x 432mm complete all as specified and as directed by Engr-in-Charge. Make: Nilkamal/ Prayag/ Polytuf |
| 95 | S&F in repair 5mm thick looking mirror of size 600x450mm of selected quality glass mounted on 6mm thick AC building board or commercial plywood and aluminium angle beading around mirrior fixed on wall PVC plug and screws etc complete all as specified and directed |
| 96 | S&F in repair soap dish of stainless steel fixed to wall with aluminium screw, complete all as specified and directed. Make Jaquar CAT No. ACN-CHR-1131N or equivalent in any of the make metnioned in list of product. |
| 97 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 98 | S&F in repair corner glass shelf with bracket fixed with chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed by Engineer-in-charge Make : ACN-CHR-1173 of JAQUAR or equivalent in any of the make mentioned in list of products. |
| 99 | S&F in repair viterous China squatting pan, `Orrisa' pattern, size 580 x440 mm white, witht integral foot rests (excluding flushing cistern and flush pipe) including connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor complete all as specified and as directed. |
| 100 | S&F in repairs 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets ,fush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specfied and as directed. |
| 101 | S&F in repairs Viterous China wash basin, white, flat back, size 550x400mm excluding taps etc but including brackets,including cutting for and pinning in ends of brackets or erecting stand but including waste coupling of fixing of supply and waste pipe complete all as specfied and as directed. |
| 102 | S&F in repair sink made of stainless steel 1 mm thickkitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 495 mm x420 mm and bowl size 410mmx330mmx 160mm including 40mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm 45gms/40mm-60 gms) complete all as specified and directed. |
| 103 | S&F in repair 32/40 mm bore PVC waste pipe flexible with minimum length 800mm complete all as specified and directed. |
| 104 | S&F in repair Stainless steel plate rack(Utensil Rack) of size (900mm x 750mmx250mm ) made out of AISl 304 stainless steel 0.63 mm thick sheet fixed with brass screw of required size including necessary fittings/nuts,bolts & washers complete all as specified and as directed. |
| 105 | S&F 15mm dia 600 mm long PVC connection including brass check nut at both ends screwed both end for iron pipes. |
| 106 | Demolition and breaking up drain pipes (Salt glazed ware, PVC/AC or Reinforced concrete) set in cement mortar,and taking out of trenches, if required, Internal dia of pipe in 75MM/100mm |
| 107 | S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 108 | S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 109 | Taking down eaves gutter and rain water pipe any size any pattern , PVC/ AC pipe including all fittings ,heads shoes, bends etc including removal to store ,Internal dia of pipe in 75MM/110mm complete all as specified and directed.all as specified and directed. |
| 110 | S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed. |
| 111 | S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed.(ISI MARKED) |
| 112 | S&F PVC (SWR) bends any radius 75mm dia all as specified and directed.(ISI MARKED) |
| 113 | S&F PVC (SWR) bends with access door any radius 75mm dia all as specified and directed.(ISI MARKED) |
| 114 | S&F PVC (SWR) bends any radius 110mm dia all as specified and directed.(ISI MARKED) |
| 115 | S&F PVC (SWR) bends with access door any radius 110mm dia all as specified and directed.(ISI MARKED) |
| 116 | S&F PVC (SWR) Single 'T ' any radius 110mm dia all as specified and directed.(ISI MARKED) |
| 117 | S&F PVC (SWR) Single 'T' radius 75mm dia all as specified and directed.(ISI MARKED) |
| 118 | S&F in repairs 75mm PVC floor trap, ISI marked with cp grating with/without waste pipe hole incl jointing to waste pipe fixed with solvent cement complete all as specified and as directed. |
| 119 | S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete & screwing etc. wind ties for roof including securing bolts; posts & struts in fencing/cooler stand including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed. |
| 120 | Removing of iron gate and re fixing of gate and including increase height of gate with hold fast as directed by Engr-in-charge. |
| 121 | Cutting channels, grooves or rebates in brick/concrete wall n. exc 15 cm girth, and trimming surface complete all as specified and directed |
| 122 | Cutting holes into or through brick walls/stone walls built in cement mortar; superficial area exc 150 Sqcm but n. exc 400 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required brick/concrete wall n. exc 15 cm girth, and trimming surface complete all as specified and directed |
| 123 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in copings, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed. |
| 124 | M&L for post construction ATT treatment to points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same all as specified and directed |
| 125 | M&L for providing and injecting chemical emulsion for post constructional anti-termite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling 12mm dia upto 300mm deep and 300mm centre to centre and plugging holes etc in apron /plinth protection all as specified in IS Code 6313 Part-3:2001 and as directed. |
| 126 | M&L for post construction ATT treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors all as specified and directed |
| 127 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, etting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, soft/loose soil. |
| 128 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 129 | S&F mild roof structural steel angles/rectangular hollow section/steel tubular roof trusses (framed), purlines and fastening including distance pieces etc. complete all as specified and directed. |
| 130 | M&L for PCC in foundations, filling and mass-concrete type C-2 (1:3:6) using 40 mm graded crushed stone aggregate for post complete all as specified and directed. |
| 131 | M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base complete all as specified and as directed. Note:- Finishing surfaces of concrete to be even and rough to receive the topping layer. |
| 132 | M&L for coloured machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60 mm thickness, M-40 grade rubber moulded glossy finish (50% red & 50% yellow) with grey cement and pigment complete all as secified and as directed.Note-Shapes of interlocking paver block shall be triangular/Zigzag/Haxagon/or other ,Colour of paver blocks & laying pattern approved by GE. |
| 133 | M&L for coloured machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 80 mm thickness, M-40 grade rubber moulded glossy finish (50% red & 50% yellow) with grey cement and pigment complete all as secified and as directed.Note-Shapes of interlocking paver block shall be triangular/Zigzag/Haxagon/or other ,Colour of paver blocks & laying pattern approved by GE. |
| 134 | M&L for sand filling under floors or in foundations including watering and consolidation or layer of sand cushioning below interlocking paver block complete all as specified and as directed. |
| 135 | S&F PCC 1:2:4 Type B-1 (using 20mm graded crushed stone aggregates) in plinth coarses, string coarses, copings, kneelerss, kerbs and the like, complete all as specified and directed. |
| 136 | S&F Pre-cast cement concrete block masonry (Kerb stone) 1:2:4 Type B-1 (using 20mm graded stone aggregates) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete |
| 137 | Surface dressing n exc 15 cm deep in soft/loose of soil complete all as specified and directed . |
| 138 | PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in surface channels and drains complete all as specified and as directed. |
| 139 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed. |
| 140 | Sch 'A' Part-I E/M Portion:-Taking down old unserviceable copper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators and sockets by unscrewing carefully from boards etc and making good disturbed surfaces of walls, as per existing finishes complete all as spd and directed. |
| 141 | M&L for point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H 1100 volte grade cable, with and including PVC rigid concealed conduit (ISI marked) with all fittings including sheet steel/CI terminal box of adequate size including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly, complete all as specified and directed.Note:- 1. connection of cable with MCBs/switch sockets shall be done through proper size copper /brass thimbles.2. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible. 3. Proper colour coud will be used for wiring as per the electrical rule and as directed. |
| 142 | All as per Srl item No 141 here-in-before but for 5 pin 5 amps socket outlet on the independent board controlled by one switch SP, one way 5 Amp, 240 Volts. complete all as specified and directed. |
| 143 | All as per Srl item No 141 here-in-before but for 5 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed. |
| 144 | All as per Srl item No 141 here-in-before but for CALL BELL point complete all as specified and directed. |
| 145 | M&L for point wiring with 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with in and including PVC concealed conduit heavy duty with all fittings including anodise pressed steel sunken box with bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed. |
| 146 | M&L for point wiring with 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with in and including PVC concealed conduit heavy duty with all fittings including anodise pressed steel sunken box with bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed. |
| 147 | S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. |
| 148 | S&F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed. |
| 149 | S&F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed. |
| 150 | S&F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. |
| 151 | S&F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed. |
| 152 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 153 | S&F ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed. |
| 154 | S&F bell push flush type 5 Amp 240 volts complete all as specified and directed. |
| 155 | S&F bell AC, 230 Volts, single pole complete all as specified and directed. |
| 156 | S&F in replacement sleek LED mirror light fitting 2 feet long 1x10 W including inbuilt ind driver complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of suitable size complete all as required at site or directed. |
| 157 | S&F CFLs with LED Lamp, B22 type ,14 watt,complete all as specified and directed. |
| 158 | S&F sleek LED Batten light fitting, 1x20 W including LED tube 4 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of suitable size complete all as required at site or directed. |
| 159 | S&F energy saving surface mounted LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 160 | Taking down carefully ceiling fan from the hook including dismantling the blades and minor repair such as replacement of locking pin, reel insulators, bolts, nuts etc and painting one coat of synthetic enamel paint of existing colour including rehanging the same at existing position after cleaning, greasing and connecting up with PVC insulated copper flexible wire of suitable size from ceiling rose to connector of fan complete all as specified and directed by Engr-in-Charge . |
| 161 | M&L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and S&F propeller PVC type AC ventilating fans, Single phase, 230 volts 225 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 162 | M&L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and S&F MS ventilating fans Single phase, 230 volts 300 mm or 12” H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. |
| 163 | S&F & testing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connecting with flexible copper conductor of suitable size, 3 core and including writing of MES No with black paint complete all as specified and as directed. |
| 164 | S&F in repair sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 165 | S&F in repair MCB SP 240 volts any rating from 6 to 40 amps, 'B' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 166 | S&F in repair MCB SPN 240 volts any rating from 6 to 40 amps, 'B' cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 167 | S&F in replacement of existing unsv sheet metal enclosure with sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps 'C' curve complete all as specified and directed . |
| 168 | S&F in replacement sub Main Wiring with two PVC insulated unsheathed multistrand FRLS-H flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 6 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed. |
| 169 | S&F in replacement of old unsv sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB FOUR POLE 63 AMPS AC 415 VOLTS 16 KA=01 NO as incoming and 12 Nos MCB SP 40Amps, C series as outgoing . ( (i) MCCB, MCB and DB should be of same make. (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly. |
| 170 | S&F in repair bldg secuirty light fitting energy saving high efficiency LED street light fitting 35 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length not less than 0.9 mtr fixing with clamp etc and making connections using suitable size copper cable from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage. |
| 171 | M&L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion complete all as shown on electric plate No 03 of SSR -2009 Part I and connecting to existing earth test point complete all as specified and directed or including testing on completion.(Note: Excavation and earth work is deemed to be included in the rates quoted). |
| 172 | Fixing of single phase/three phase electric energy meter and connecting up ncluding provision of PVC insulated and overall sheathed flexible copper conductor cable 3 core, 4Sqmm from main connection to DB complete all as specified and directed by Engineer-in-charge |
| 173 | Supply, laying and testing in replacement LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 2 core complete all as specified |
| 174 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed. |
| 175 | Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified. |
| 176 | Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 177 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified (Note:-Punned thickness shall be measured and paid) |
| 178 | M&L for brick covering equal to length of bricks as mechanical protection to cable with well burnet sub class ‘B’ bricks laid as directed by the Engr-in-Charge. |
| 179 | S&F GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole including fittings /clamp complete all as specified and directed. |
| 180 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 89,859.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail