| 1 | Cleaning of grass, vegetation growth/saplings growth after uprooting from roof top completely incl making good disturbed sutrcafe in CM 1:4 complete to match the existing all as specified and directed. |
| 2 | Taking down existing roof treatment of any description incl mud phuksha or PCC pedding if any (any no of layers) incl brick tiles , terracing tiles if any including removal to dabries in low laying area exc 1.00 KM but n exc 2.00 KM complete all as directed. |
| 3 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mub stop/ leveling course on existing roof or sunken floor of toilet portion, rounded and chamfered on edges, complete all as spd and directed |
| 4 | M&L for 20mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth with WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in per bag of cement. |
| 5 | Liquid water proofing compound |
| 6 | M&L for APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :-(a) Cleaning the top surface of RCC roofing properly with water complete.(b) Applying Oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface.(c) Laying of membrane not less than 3.0 mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 150 Gms/Sqm using butane torch by torch application with 10 Cm side laps and 15 Cm end lap complete. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.(e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg /Sqm as prescribed by manufacture of membrane.(f) APP Membrane shall be stick inside parapet where available by chase cutting and sealed with PCC (1:2:4) type B-0 complete. |
| 7 | M&L for cleaning and preparation of existing Non acceessible/accessible roof surface of any description upto ht of double storey bldg properly by washing and drying, removing all loose material, dirt and foreign particles incl fungus /algae/overgrowth of plants if any completely.identify the cracks over terrace and around the rain water spouts and the same should be grouted with 1:3 CM and make the terrace completly smooth as per slop.The application shall include base preparation with application of primer coat and then apply first coat of cold liquid Membrane STP Tarfelt LM or equivalent make having elongation not less then 200% conforming to ASTM-C-412 & having crack bridging ability of 3.00 to 4.00 mm confirming to ASTM-C-836 with tensile strength ranges to 8 -12 N/sqmm and confirming to ASTM-C-412 with no diluation of water.. Apply 2nd coat similar to first coat after 12 Hrs in opposite direction of first coat by Brush or Roller.. Applying two coats of U V Resistant Elastomeric Exterior Axcrylic Weather resistant water proof coating of Shalicryl-215 or equivalent approved make. Note:- Application of water proofing treatment will be done by Authorised Applicator only. |
| 8 | M&L for 10 mm thick cement plaster in cement mortar 1:3 on brick or concrete surface of sunken floor finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified & directed. |
| 9 | M&L for bitumen blown any grade, applied hot, two coats, to concrete/plastered surfaces at the rate of 1.5 Kg per sq m per coat and applying polythene film black, 50 micron complete for sunken floor slab and embedded in side wall / covered fillet complete all as specified and directed. |
| 10 | M&L for 25 mm thick P. C.C type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in sub floors for laying floor finish complete all as specified and directed. |
| 11 | M&L for Plain cement concrete 1:5:10 type E2 using 40mm graded crushed stone aggregate as in sunken floors and all as specified and directed. |
| 12 | S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laidin trenches or in floors |
| 13 | S&F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laidin trenches or in floors |
| 14 | S&F in repair 75mm bore PVC (SWR) floor trap, plain with grating including including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating complete all as specified & directed. |
| 15 | S&F in repair 110mm dia PVC (SWR) bends any radius |
| 16 | S&F in repair 75mm dia PVC (SWR) bends any radius |
| 17 | Dismantling of plain or corrugated AC sheeting, any gauge, thickness, including ridge etc as in roof covering. |
| 18 | Dismantling timber scantlings 40 sq. cm and over in section, in framed work and in any position |
| 19 | S&F rolled mild steel roof truss (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290 Gde E-165 .and applying two coat of synthetic enamel paint over a coat of red oxide primer on exposed surfaces complete all as specified and directed. |
| 20 | S&F tubular framed steel trusses made out of MS medium grade tube (ERW or induction butt welded) conforming to I. S.1161-1979 grade St.-240 quality 'A', including welding of distance pieces, cleats, special shaped washer etc. and applying two coat of synthetic enamel paint over a coat of red oxide primer on exposed surfaces complete all as specified and directed. |
| 21 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified. |
| 22 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in Ridge/roof covering , fixed with self tapping screws as specified. |
| 23 | M&L for False ceiling of 9.5mm thick gypsum tiles (600x600mm) laminated with PVC film on the face side & metalised polyester film on the back side with all four edges sealed with PVC film (shade either plain white or crack) fixed using T grid/Cross-T/Wall angle/level clip & suspenders of standard galvanised sections in a grid size of 600x600mm, including taking down existing ceiling board & grid work etc of any type/pattern complete all as specified and directed. |
| 24 | Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed. |
| 25 | Demolition of cement concrete (unreinforced) etc in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 26 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc including brushing with neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified & directed. |
| 27 | Dismantling floor, hearth or wall tilling and terrazo topping incl cement mortar bedding ( but not backing) removing serviceable tiles to stores and rubish off the premises |
| 28 | Taking down cement plaster/ including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed |
| 29 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified & directed. |
| 30 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified & directed. |
| 31 | Taking down shutters of any description exc. 1 sqm and not exc. 2 Sqm each, complete all as specified & directed. |
| 32 | Taking down shutters of any description n exc. 1 sqm each, complete all as specified & directed. |
| 33 | Taking down, easing and adjusting shutters of any description, exceeding. 1.00 Sqm and not exceeding 2.00 Sqm each and re-fixing in the same or other opening completa all as specified and directed. |
| 34 | M&L for Brickwork with burnt clay Bricks (old size), straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified. |
| 35 | M&L for except brick of any description in CM 1:6. complete all as specified. |
| 36 | S&F Pressed steel frames of size 125mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate.incl tarring/black bituminous paint to unexposed surface, complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately. |
| 37 | S&F Pressed steel frames of size 105mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate incl tarring/black bituminous paint to unexposed surface, complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately. |
| 38 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 39 | M&L for PCC 1:3:6 nominal mix, type C-1 using 20 mm graded crushed stone aggregate as in filling of pressed steel door frames/chowkats, complete all as specified & directed. |
| 40 | M&L for 35mm thick 2nd class hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified & directed. |
| 41 | M&L for 35mm thick factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified & directed. |
| 42 | S&F 35mm thick H.D.F prelaminated (Wenga/Teak colour) moulded shutter 35 mm thick puf (poly urathane foam) insulation with minium density 40kg/cum filled in between two HDF sheets of thickness 3.2 mm both & border covered with 10 mm thick PVC sheet.complete all as specified and directed. |
| 43 | M&L for 35 mm thick single piece factory made wire gauge door shutter and incl of wire cloth ( steel & aluminium XPM) manufacturing by PVC sheets printed 5 mm thick on both side on frame made out of M.S. tube 19 SWG, size 19x19 mm complete in all respect with lock rail & beautified by PVC beading all around fixed with PVC solvent cement.complete all as specified and directed. |
| 44 | S&F Steel window/ventilator factory made, made out of mild steel box type and shutter suitable for double shutter i.e. Glazed and gauged shutter. Glazed shutter made out of hollow' section with sash bar and gauged shutter made out of hollow section without sash bar including hinges, tower bolt, handle, grill 10 mm sq bar including two coat of synthetic enamel paint over one coat of red oxide primer, tarred hold fasts, PCC bed blocks for fixing hold fast, including plain/figured glass 3mm thick and stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.18mm & fixed with stainless steel wire staples`etc complete all as specified and directed. |
| 45 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site complete all as specified and directed by Engr-in-Charge. |
| 46 | M&L for Repair to Old steel window not exc 2.00 Sqm each incl replacement of hinges, Handle, and necessary oiling ,welding to shutter and chowkhat for making window in cerviceable condition, Complete all as specified |
| 47 | M&L for Hasp and staple 100 mm in size, aluminium anodised, including bolt to hinge plate and fixed with screws. |
| 48 | S&F factory made 18mm(+ 0.7mm) thick PVC sheet one side prelam sheet for cupboard shutter of density 600 kg /Cbm bent 90° and finish at all edges at level for making edges at level for making edge lipping/bending or 0.5mm thick PVC sheet lipping at 4 edges using bonding tape etc. Complete as per direction of Engr-in-charge, Manufacture specification.. |
| 49 | S&F in repair Prelaminated particle board, interior grade, 18/19 mm thick prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with screws to timber frame work |
| 50 | S&F continuous (piano) hinges, mild steel, bright finish width of flaps (when open ) 30 mm all as specified and directed. |
| 51 | S&F Aluminium alloy, anodised, sliding door bolt 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed . complete all as specified and directed. |
| 52 | S&F Aluminium, anodised, barrel tower bolts 150 mm of extruded section and fixed. complete all as specified and directed. |
| 53 | S&F Aluminium, anodised, handles 125 mm of extruded section and fixed.complete all as specified and directed. |
| 54 | S&F Mild steel, 300mm, ordinary rat tail rod patttern springs includding roller and roller plate complete fixed with screw or necessary welding to pressed steel door frame. |
| 55 | S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with statinless steel wire staples. |
| 56 | S&F in repair Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm with statinless steel wire staples. |
| 57 | Hacking out old broken glass (any thickness, size, quality or description) from matel frame including punching or drilling out old glazing pins/spring clips and providing and fixing new onces exc 1.5 Sqm |
| 58 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc. 0.5 sqm in each pane , complete all as specified and directed. |
| 59 | S&F 3mm thick figured glass, pin head type and glazing with oil putty or wooden beads in square n.exc 0.5 sqm each complete all as specified & directed. |
| 60 | S&F in repair 25mm outer dia stainless steel decorative drapery rod of thickness 20 guage with stainless steel brackets near to ends with stainless steel funnels with adopter for 25 mm dia drapery rod at both ends complete all as specified and directed. |
| 61 | Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 62 | S&F steel water tubing 15 mm bore medium grade galvanised with all fittings (ISI marked) fixed complete to walls, ceiling and floor. complete all as specified. |
| 63 | Disconnecting existing water tanks of capacity 1000 litres, any description, setting aside for repair, cleaning etc and hoisting reconnecting and refixing in same or other position incl cleaning with bleaching powder removing scaling etc ,provn of new GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer etc complete all as specified & directed. |
| 64 | Disconnecting existing water tanks of capacity 500 litres, any description, setting aside for repair, cleaning etc and hoisting reconnecting and refixing in same or other position incl cleaning with bleaching powder removing scaling etc ,provn of new GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer etc complete all as specified & directed. |
| 65 | S&F Rotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 66 | S&F Rotational moulded polyethlene water storage tanks three layers of 1000 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 25mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including Dismantling of old brocken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 67 | S&F in repair Concealed Stop valve (ISI Marked), cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore and fixed. |
| 68 | S&F in repair Bib tap 15 mm bore long body, Brass CP, fancy type (long shank )., with crutch or butterfly handle screwed down screwed for iron/PVC pipe or for brass ferrule and fixed, complete all as specified. |
| 69 | S&F in reapir Bib tap 15 mm bore short body, Brass CP, fancy type (long shank )., with crutch or butterfly handle screwed down screwed for iron/PVC pipe or for brass ferrule and fixed, complete all as specified. |
| 70 | S&F in reapir Stop valve /Angle valve (ISI Marked), fancy type, chromium plated with long shank and cup screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron /PVC pipe or for unions of 15 mm bore andcomplete all as specified. |
| 71 | S&F in repair Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. |
| 72 | S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete. |
| 73 | S&F in repair, Vitreous china squatting pan of pattern, long pan, 'Orissa pattern', size 580 x 440 mm white with integral foot rests (excl flushing cistern and flush pipe) but including provision concrete bedding CI floor trap etc complee |
| 74 | S&F in reapir , Vitreous china wash down water closet pan (Pedestal pattern) white (excl fixing bolts, flushing cistern and flush pipe) but including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel CP or aluminised hinging device. |
| 75 | S&F in repair floor mounting single piece Vitreous china wash down water closet pan , light colour complete including fixing to trap , alongwith PP soft close seat cover, hinges and accessories complete all as specified and directed. |
| 76 | S&F in repair CP Brass Hand Shower (Health Faucet) with 8 mm dia,1.2 m long Long Flexible Tube Chrome Finish & Wall Hook for Water closet complete all as specified and directed. |
| 77 | S&F in repair CP brass towel ring 20mm dia, fancy type, superior quality, fixed with and including chromium plated screws and wooden/plastic cleats complete all as specified and directed. |
| 78 | S&F in repair chromium plated brass central hole single lever WHB Mixture 15 mm bore for mixing hot and cold water with 450 long braided house 20 cartriage size screwed down, high pressure screwed for iron pipe complete all as specified and directed. |
| 79 | S&F in repair CP wall mixer without popup waste system with 450mm long braided hoses cast copper alloy for iron pipes 15 mm bore, screwed for iron pipe and fixed and all as specified and directed. |
| 80 | S&F in repair PVC flushing cistern 10 ltr capacity incl PVC connection inlet and and outlet connections,brackets, PVC flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC all as specified and directed. |
| 81 | S&F in repair sink with drainage board made of stainless steel 1 mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 915 mm x460 mm and bowl size 410mmx330mmx 160mm complete all as specified and directed. |
| 82 | S&F in repairs Vitreous china wash basin, flate back white of,size 550 x 400 mm, including cutting for and pinning in ends of brackets or erecting stand including 32 mm bore CP waste pipe long screw thread and 32 mm dia flexible waste pipe incl fixing of taps all as spd and directed. |
| 83 | S&F in repair Vitreous China Urinal, Half stall type, white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, , flush pipe, grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) fixed incl S&F of CP coupling, waste pipe and cp brass spreder all necessary fittings, complete all as specified and directed. |
| 84 | S&F PVC connection 15 mm bore with PTMT nuts of length 450 mm long. |
| 85 | M&L for Non skid ceramic jointfree coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.18 sqm but nexc 0.38 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed . |
| 86 | M&L for Non skid ceramic jointfree coloured tiles, 7 to 8 mm thick (square/ rectangular) as in skirting etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 10mm thick screed layer in cement mortar 1:4, complete all as specified and directed . |
| 87 | M&L for Non skid ceramic jointless coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed . |
| 88 | M&L for Glazed ceramic coloured tiles of size 450mmx350mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed. |
| 89 | M&L for Vitrified light shade ceremic tiles 600mmx600mmx 10 mm thick (Square/rectangular) polished in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar 1:6, complete all as specified & directed. |
| 90 | M&L for Vitrified light shade ceremic tiles 600mmx 600mmx 10 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36Sqm in skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm thick rendering in cement mortar 1:4, complete all as specified & directed. |
| 91 | M&L for 18-20mm thick granite (pure black) work (table rubbed and polished) in steps, jambs pillars, window cills ,cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigments to match with shade or granite over including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc complete all as specified and directed. |
| 92 | M&L for Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over 20 mm thick screed bed in cement and sand mortar 1:6 complete all as specified. |
| 93 | M&L for Machine cut Kota stone slab not less than 16mm thick as in riser of steps, skirting, dado and pillar laid over & including 10 mm thick screed base in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine, complete all as specified. |
| 94 | M&L for coloured machine pressed precast rubber moulded concrete interlocking red/yellow) paver block of any shape and size with 6-8mm white cement layer mixed with pigment and coated with epoxy coating having high glossy finish confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid dry over and including 50mm thick sand filling under paver, properly levelled etc, complete all as specified and directed. |
| 95 | M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping, bed plates benching,floor by maintaing required gradient/undulation etc slightly rounded or chamferred angles and throating, complte all as specified and directed. |
| 96 | M&L for 75 mm thick cement concrete type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) as in Sub-base to floor finishes. |
| 97 | M&L for Rendering 10 mm thick plaster in cement mortar 1: 3 on concrete surfaces as in ceilings finished even and smooth without using extra cement, complete all as specified. |
| 98 | M&L for Rendering 10 mm thick on fair face of brick work or concrete surface in CM 1:6, finished even and smooth without using extra cement. |
| 99 | M&L for 15mm thick rendering in two layers (5mm thick in CM 1:4 over 10mm thick in CM 1:6) on brick work and concrete surfaces of wall, finished the surface even and smooth without using extra cement, mixing and including WPC @ 200ml/bag of cement, complete all as specified and directed. |
| 100 | M&L for 75 mm thick cement concrete 1:3:6, type C1 (using 20mm graded crushed stone aggregate) as in plinth protection finished even and smooth using extra cement.(incl necessary joint filling with mixture of paving bitumen & sand in 1:3) |
| 101 | M&L for Preparation of newly plastered surface of wall and applying two coat of oil bound distemper, white or tinted shade with and including priming surface with chalk whitening , complete all as specified. |
| 102 | M&L for Complete removal of existing treatment of wall surfaces and applying two coat of oil bound distemper, white or tinted shade with and including priming surface with chalk whitening , complete all as specified. |
| 103 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 104 | M&L for Complete removal of existing treatment of wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces. |
| 105 | M&L for preparation of old decorated plastered or unplastered surfaces of Walls by brooming down or steel wire brushing ,scrapping down smoke soots, moulds and efforescent salts and trading oil and greasy spots incl cornices washing down with water etc and applying one coat of Cement Base Paint , white or tinted complete incl removing grass, vegetations or small trees etc and making the good disturbed surface in CM 1:3 all as specified & directed. |
| 106 | M&L for preparing newly plastered surfaces and applying three coats of white wash as in ceiling etc. |
| 107 | M&L for preparing of plastered surfaces of ceiling, old decorated surfaces and applying one coats of white wash. |
| 108 | M&L for two coat of white wash on old plaster surface of wall including preparation of surface complete all as specified & directed |
| 109 | M&L for preparing of Old painted surfaces of steel or iron surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint. |
| 110 | M&L for preparing of new or previously untreated surfaces of wood of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. |
| 111 | M&L for preparing of Old painted surfaces of wood of any description not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint. |
| 112 | M&L for taking down existing Aluminium door/window and refixing to the same opening after repairing, easing and adjusting incl replacement of damaged hinges, brass mortice lock, Elco Panel , rubber neoprene packing, complete all as specified and directed. |
| 113 | S&F in repair Aluminium( extruded section body) Door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed all as specified and directed. |
| 114 | S&F in repair Sheet glass 4.8mm thick ,ordinary quality fixed with aluminium beading and rubber gaskeet exc 0.50 sqm each. all as specified and directed. |
| 115 | S&F in repair 8 mm thick transparent toughened sheet glass with rubber packing fixed to metal frame including hacking out old glass complete in all respect as specified and directed. |
| 116 | S&F in repair for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty. all as specified and directed. |
| 117 | M&L for 5mm thick Coloured/ printed PVC Wall Lining (panel type) consisting of 5mm thick Plain colour PVC sheet panels of size 3000mm in length and 250 mm in width having wt 360 gms fixed to wall using screw in method as per specifications and drawing at site incl fixing of 3mm thick PVC sheet fillet/mouldings of width upto 25mm above PVC wall lining work, complete all as specified and directed incl taking down existing lining of any description complete all as specified and directed. |
| 118 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 42,578.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |