Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exceeding 1.50 Sqm each including taking out hold fast embedded in PCC, complete all as specified and directed. |
| 2 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 Sqm and n.exc 4 Sqm each, including taking out hold fast embedded in PCC, complete all as specified and directed. |
| 3 | Taking down shutters of any description exc 1 Sqm but n exc 2 Sqm each, complete all as specified and directed. |
| 4 | S&F pressed steel frame for doors made out of MS sheet 1.25mm thick of size 125mmx60mm for with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. including filling of concrete 1:3:6 type C-1 back of chowkhats complete all as specified and directed. |
| 5 | S&F pressed steel frame for door made out of MS sheet 1.25mm thick of size 105mmx60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. including filling of concrete 1:3:6 type C-1 back of chowkats complete all as specified and directed. |
| 6 | S&F 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 7 | S&F 35mm thick 2nd class hard wood in glazed and Skelton factory made shutters open rebated and prepared to receive glass/wire gauge etc. with sash bars edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass/wire mesh etc. sizes of members as per clause 8.20(a) of SSR Part-I complete all as specified and directed. |
| 8 | S&F floor door stopper of overall length of cover plate 140mm aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed. |
| 9 | S&F factory made uPVC white colour casement (Openable) window double shutter , one glazed and other fly proof shutter side hung area and n exc 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 109 mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of' zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass and SS wire mesh complete all as specified and as directed. Grill:- Window should be provided with grill made of 10 mm Sq MS bars welded to at 150 mm centre to centre, 6mm x 12mm MS flat and fixed to window frame with screws. including dismantling of old steel window all as specified and directed |
| 10 | S&F ventillators/ louvers with partially guaged shutter using 5 mm thick x 10 cm wide frosted glass strips and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading and all necessary fittings as required etc all as directed including dismantling of old seel ventilator.(a) SP 20048(b) Glazing clips 19352 |
| 11 | S & F Anodised designer grill of 7mm dia fixed with and including flat section of size 50x1.5mm fixed to aluminium window complete all as specified and directed. |
| 12 | S&F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repairs complete all as specified and directed |
| 13 | S&F Factory made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles) with 2 mm thick moulded prelam PVC sheet on the front face and 2 mm prelam PVC sheet on back face, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 14 | S&F 100mm long butt hinges medium weight cold rolled ISI marked stainless steel complete all as specified and directed including necessary welding if required . |
| 15 | S&F 125mm extruded aluminium alloy handle fabricated anodized ISI marked, complete all as specified and directed. |
| 16 | S&F 150mm extruded aluminium alloy handle fabricated anodized ISI marked, complete all as specified and directed. |
| 17 | S&F 200mm long aluminium, anodized barrel tower bolts of extruded section ISI marked, complete all as specified and directed. |
| 18 | S&F 150mm long aluminium, anodized barrel tower bolts of extruded section ISI marked, complete all as specified and directed. |
| 19 | S&F in repair, 300mm, Mild steel spring for door, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified. |
| 20 | S&F for 300 mm long mild steel sliding door bolts, plate type, with stainless steel bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and directed. |
| 21 | M&L in 100mm cast iron sanitary connection socket ‘P’ branch, with branch 375 to 450 mm long complete all as specified and directed. |
| 22 | S&F galvanized mild steel wire cloths 0.46mm nominal dia and average width of aperture 1.18mm & fixed with tint tacks or galvanized wire staples complete all as specified and directed. |
| 23 | M&L for two coats of synthetic enamel paint on new wooden surfaces including preparation of surface and one coat of pink primer all as specified. |
| 24 | M&L for preparation of old painted steel surface of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 25 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, complete all as specified and directed. |
| 26 | M&L for brick work in cement mortar 1:6 of old size sub class ‘B' bricks straight or curved on plan exceeding 6mtr mean radius, complete all as specified and directed. |
| 27 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, complete all as specified and directed. |
| 28 | S&F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted fixed in position all as specified in SSR part-I, capacity of tank 1000 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively 20mm GI pipe medium grade over flow pipe 15cm long and PTMT valve 20mm high pressure with polyethylene float and fly nuts including dismantling water tanks (capacity of tank exc. 500 ltr but n. exc. 1000 ltr) and removing from site complete all as specified and directed. |
| 29 | M&L 20mm dia Gun metal globe or gate walve with iron wheeled head, screwed both ends for iron and fixed in repairs complete all as specified and directed. |
| 30 | S&F PVC (SWR) pipes single sockets in any length with rubber ring joints as in repair fixed to walls with clamps as a rain water pipes, 110mm bore with cement joints complete all as specified and directed. |
| 31 | S&F PVC (SWR) bends of 110mm bore any radius as in repair complete all as specified and directed. |
| 32 | Taking down old eaves gutters and rainwater pipes (any size or pattern) , including all fitting ,head ,shoes ,bend, swan-nacks etc., including cleaning or refixing or removal to store . |
| 33 | Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water complete all as specified and directed. |
| 34 | M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement and curing the surface, complete all as specified and directed. |
| 35 | S&F UPVC underground drawings pipe (UDS) type 'B' 160mm dia with wall thickness 4mm (min) and pressured 4 KN /Mtr Sq jointed in cement solvent complete including providing 100 mm thick cement concrete (1:4:8) type D-2 using 40mm graded crushed stone agg as in bed for 160mm bore pipes incl packing under and haunching against the sides of pipes after they are laid tested including taking down old damaged SGSW pipes from existing lines including necessary excavation of old fitted in trenches complete all as specified and directed. |
| 36 | M&L for cutting into existing manholes for connecting new drains/ pipe of any dia, making good to pipe and making good of broken manhole. |
| 37 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even & smooth without using extra cement including scaffolding upto 7 meter height and curing the surface, complete all as specified and directed. |
| 38 | M&L for Rendering 5mm thick in cement mortar 1:3 in, ceiling and roof projection making the line in true shape finished even and smooth without using extra cement as in ceiling complete all as specified. |
| 39 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed |
| 40 | M&L for complete removal of existing treatment internal /external on wall/Ceiling/ roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7\\" /9\\" to make free from dust, loose paint etc by skilled labour including necessary scaffolding where as required complete all as specified and directed. |
| 41 | M & L for water proof cement based putty @ 1 kg (undiluted) per Sqm of average thickness 1mm over the plastered/ old prepared painted surface of wall/Ceiling and sanding of the putty surface with mechanical wall sander (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per the following steps:-Step 1 :- Mix the putty powder by adding water as per manufacturer's instruction and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute.Step 2 :- Apply the first coat of the prepared mixer with the help of fully automatic airless spray machine of putty application finishing the surface even and smooth in level without any undulations.Step 3 :- Allow 6-8 hrs time to dry the putty surface |
| 42 | M&L for one coat of acrylic waterbased Interior grade primer @ 0.8 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent coats as in wall/ceiling complete all as specified and directed. |
| 43 | M&L for one coat of acrylic waterbased exterior grade primer @ 0.8 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface for painting of subsequent coats as in wall/ceiling complete all as specified and directed. |
| 44 | M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface as in wall/ceiling complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. |
| 45 | M&L for surfaces of walls, roof projection/windows chajjas & similiar and applying weather proof two coats water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed.Note : - Tint/Shade shall be approved by Engr-in-ChargeNote for Item No. 40 to 45 above (a.) The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Cement base paint, Putty etc. is proposed to be used by the contractor and approved by Garrison Engineer. |
| 46 | M&L for Non skid ceramic colour tiles 7 to 8 mm thick (sq/ rect) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 including dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off premises complete all as specified and directed. |
| 47 | M&L Glazed ceramic coloured tiles of size 600X300x7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 including dismantling of wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to a store and rubbish off premises, complete all as specified and directed. |
| 48 | M&L for vitrified ceramic 10 mm thick light shade (sq/ rect) polished, area of each tile not exceeding 0.36 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 including dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off premises, complete all as specified and directed. |
| 49 | Taking up or down GI pipe 15mm bore and connections, including cleaning for refixing or removal unserviceable pipe including S&F 15mm bore GI tubing medium grade galvanized ISI marked with all fittings complete on walls, complete all as specified and directed. |
| 50 | Taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceable pipe including S&F GI tube 20mm bore medium grade galvanized with all fitting and fixed to short length, complete all as specified and directed. |
| 51 | M&L for cutting chases, pinning in brick work for concealed water tubing and making good to facings where required and pointed in cement mortar 1:3 cutting not exceeding 10cm girth, complete all as specified and directed. |
| 52 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise sepecifically provided for all as specified. |
| 53 | M&L reinforced cement concrete as in shelf (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs kitchan platform, shelves and similar articles including necessary moulds/formwork set in cement mortar (1:6), complete all as specifed and directed. |
| 54 | S&F in repair vitreous China squatting pan Orissa pattern size 580 x 440mm white with integral foot rest (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anty syphonage pipe etc. and including 110mm bore PVC 'P' or 'S' trap complete incl making good to floor complete all as specifed and directed. |
| 55 | S&F in repair vitreous china wash hand basin (flat back or angle back type) coloured of bowl size 550mmx400mm including including cutting for and pinning in ends of brackets or erecting stand etc complete all as specified and directed. |
| 56 | S&F in repair Basin Mixer, swan neck tap, cast copper alloy chromium plated with capstan heads screwed down high pressure or without lettered hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed. |
| 57 | S&F for Flushing jet spray/health faucet for pedestal pattern W.C including flexible pipe and brass Chromium plated nuts, fixed in repairs complete all as specified and directed. |
| 58 | M&L liquid water proofing treatment to RCC roof slab incld dismantling of existing treatment of any description in following procedure : (a) Laying 10mm thick rendering in Cement mortar 1:4 mixed with WPC 3% by weight of cement on fair faces of concrete roof surfaces , finished even and fair to receive treatment on roof Complete (b) Applying first coat fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with sun reflective index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 Mpa and shall have reack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celsius with 3.3% dilution as priming coat (c) laying of fiber mesh 0.3mm thickness weave in leno pattern having weight 4.5 gm/ Sqm and pasting it properly with overlap of 50mm and allow it to dry (d) Applying second coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge (e) Applying third and final coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster) |
| 59 | M&L for water proofing treatment to sunken slab, walls, etc, and shall be carried out as specified below and as directed.(a) Clean the sunken portion of toilet / Baths/ WCs/ Kitchen thoroughly to remove laitance, dirt, dust etc.(b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar (“ Dr fixit” Pidicrete URP” or eqvt).(c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bath seal Tape” and the gaps to be grouted with non-shrink cementitious grout “Dr Fixit Bath seal Grout” or eqvt. Nahani traps etc to be fitted securely and the gaps around it to be grouted in the same manner.(d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bath seal Plus” or eqvt on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.(e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproofing waterproof coating “Dr Fixit Pidifin 2 K” or eqvt can be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely.(f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type C-0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2.(g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of approved makes such as Dr Fixit, FOSROC, SIKA etc |
| 60 | M&L PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in padding over roof slab for providing proper slope 1:40 and approx thickness 50mm or less and finished the surfaces even and smooth wihtout unsing extra cement including demoilition of cement concrete of any description complete all as specified and directed. |
| 61 | S&F machine pressed precast concrete interlocking paver blocks with grey cement and pigment, any shape and size conforming to IS 15658:2006 of 60mm thickness M35 grade including 25mm thick sand cushioning complete all as specified and directed. |
| 62 | M&L for Non abrasive paving (rectified endura) heavy duty cement concrete coloured tiles 300x300mmx10mm thick set jointed and pointed in neat cement slurry mixed with pigment laid over 15mm thick screed bed in cement mortar 1:4 including demolition/dismantling old surface/tiles complete all as specified and directed. |
| 63 | S&F bib taps long body, fancy type, chromium plated, cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed down screwed for iron pipe of 15mm bore, complete all as specified and directed. |
| 64 | S&F in repair 15mm bore Angle valve fancy type chromium plated ISI marked with crutch or butter fly handle high pressure screwed both ends for iron pipe or for union and fixed complete all as specified and directed. |
| 65 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks stage and similar work conforming to Fe.290.Gde-E-165 all as specified and directed |
| 66 | S&F in repair CP towel ring PTMT fixed with and including Chromium plated brass screws and cleats (min wt 90 gms), complete all as specified and directed. |
| 67 | S&F in repair CP toilet paper holder with flat recessed type stainless steel including CP screws complete all as specified and directed. |
| 68 | S&F in repair of Toilet Duct Pipelines for Domestic Water Pipes downtake pipes fixing done with Pipe Supporting Clamping System having Mono Bracket + U Bolt R/M System - 1. Domestic Water Supply Down take lines 3/4\\" GI - 1 nos. from 1st Floor to Ground Floor Vertical Fixed line with wall distance 2\\": Pipe Support Clamping made of 1. Mono Bracket with slot Wall Distance 2\\" for 3/4\\" GI pipe made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 48 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs. 2. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Mono Bracket with Slot Wall distance 2\\" for 3/4\\" GI pipe - 1 Nos. 2. U Bolt R/M for 3/4\\" GI pipe Dia. - 1 nos. 3. Justi Khilla GI coated 2 1/2\\" - 2 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified and directed. |
| 69 | S&F in repair of Toilet Duct Pipelines for Domestic Water Pipes downtake pipes fixing done with Pipe Supporting Clamping System having Mono Bracket + U Bolt R/M System - 1. Domestic Water Supply Down take lines 3/4\\" GI - 1 nos. from 1st Floor to Ground Floor Vertical Fixed line with wall distance 2\\": Pipe Support Clamping made of 1. Mono Bracket with slot Wall Distance 2\\" for 3/4\\" GI pipe made of Low Carbon Hot Roll gauge corrected Oil Pickeled & Drawn (HROP D) Steel (IS 1079); material size 48 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result above 2000 hrs. 2. U bolt R/M are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing as per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty.: 1. Mono Bracket with Slot Wall distance 2\\" for 3/4\\" GI pipe - 1 Nos. 2. U Bolt R/M for 3/4\\" GI pipe Dia. - 1 nos. 3. Justi Khilla GI coated 2 1/2\\" - 2 nos. Pipe Support Clamping Unit fixing to be done at every metre distance in the duct as specified and directed. |
| 70 | S&F in repair vitreous china wash down water closet (pedestal pattern) white colour including P or S trap, fixing bolts and connecting to drain pipe, including seat cover plastic flat bottom, Butterfly Stainless Steel Jet or Bidet hands free spray and Stainless Steel Chromium plated hinging device and connection to flush pipe, anti syphonic pipe etc complete all as specified and directed. |
| 71 | S&F brass chromium plated tubular towel rail 20mm dia D type 60cm long between flanges, complete all as specified and directed. |
| 72 | S&F in repairs 10 liters PVC low level flushing cistern (white colour) syphonic action type with inlet ball valve float and push type handle including bracket, PVC 32mm dia flush pipe with coupling and fixed complete all as specified and directed. |
| 73 | S&F in repair sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes pipe and waste coupling including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 74 | S&F in repair PVC connection 15mm bore size with PTMT nuts of length 450mm complete all as specified and directed. |
| 75 | S&F in repairs for Sheet glass corner shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 76 | S&F Sheet glass shelf assembly consisting of 5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 50cm long complete all as specified and directed. |
| 77 | S&F in repair Cabinet Mirror of size 400mmx500mmx6mm thick with frame as per Cat Part No.554 of Prayag or technocommercial equivalent complete all as specified and directed. |
| 78 | S&F in repair stop/ angle valves (ISI marked), 15mm dia, cast copper alloy, chromium plated fancy type with long shank and cup(concealed type) screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipes or for unions and fixed in pipe, complete all as specified and directed. |
| 79 | S&F grating round 100 mm size of stain less steel as in repair, complete all as specified and directed. |
| 80 | S&F in repairs brass chromium plated shower rose 75mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed. |
| 81 | M&L 75mm CI Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed. |
| 82 | S&F 100 mm bore sand Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed. |
| 83 | S&F 75 mm bore sand Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed. |
| 84 | S&F PVC (SWR) floor trap/ Nahani trap, plain including jointing with solvent cement complete all as specified and directed. |
| 85 | M&L 100mm CI Bends (any radius), with ovel acess door diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 86 | S&F in repair Stain less steel curtain rods 25mm dia factory fixed, complete all as specified and directed. |
| 87 | S&F in steel brackets for 25 mm dia rod fixed with screws and gutties in wall and fixed to curtain rod with screws of design/shape, complete all as specified and directed. |
| 88 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed. |
| 89 | M&L for Jet Black granite18- 20 mm thick Machine cut , pre polished, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone as in kitchan plateform , flooring including grinding mirror polishing and half moulding laid over 15 mm thick screed bedding in cement mortor 1:6 and all other similar works complete all as specified and directed. |
| 90 | M & L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works; not exceeding 200 mm thick complete all as specified and directed. |
| 91 | Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thicknss (below or above ground level) complete all as specified and directed. |
| 92 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise sepecifically provided for complete all as specified and directed. |
| 93 | M&L 75mm thick plain cement concret type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in flooring/Sub base/Plinth protection all as spd and directed. |
| 94 | M&L for Mild steel TMT bars 6mm to 8mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 95 | M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 96 | S&F in repair SS chromium plated, plated peg set fixed with screw complete all as specified and directed. |
| 97 | M&L for Preparation of new painted steel surface of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 98 | M&L for PCC padding in roof slabs/chhajjas in PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate with and incl integral water proofing compound @ 3% weight of cement and providing necessary slope towards outside complete all as specified and directed. |
| 99 | S&F in repair mild steel, chromium plated Soap Dish fixed with and incl CP screws all as specified and directed. |
| 100 | S&F prelaminated 18 mm thick lead free factory made 100 % solid WPC (wood polymer composite) sheet having high natural fiber content 25 to 30 % wood colour sheets with density not less than 500 Kg/Cum and the weight of sheet of 1 Sqm should be 11 Kg(+- 5%) manufactured by ISO 9001-2015 certified company. The sheet should be 100 % water proof, termite proof ,fire retardant, manufactured by single layer extrusion process with excellent screw holding capacity and shore D hardness, complete all as specified and directed. |
| 101 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other frame/Chowkhat of size 45x70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum , screw withdrawal strength of 2200N (Face) & 1100N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properly of being termite/borer proof, water/moisture proof and fire retardant 152 Section 8 and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length, complete all as specified and directed. |
| 102 | S&F magnetic door catches with sticking plate of standard size for cupboard/cabinet doors aprooved by GE as specified and directed. |
| 103 | S & F continuous piano hinges (30mm width of flaps when open) mild steel, bright finish complete all as specified and directed |
| 104 | S&F 100mm Hasp and staple, safety type, aluminum anodised including bolt to hinge plate and fixed with screws complete |
| 105 | Dismantling boarding, any description, fixed in any positionwith nails complete all as specified and directed. |
| 106 | M&L rendering 10mm thick on concrete in CM 1:3 in facia or edging of chajjas,ceiling and roof projection etc incl taking out pealed off plaster/concrete and making good to cracked RCC surface in true line /shape by providing PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate including all necessary form work to thickness at required at GF and FF finish even and smooth without using extra cement complete all as specified and as directed by Eng-in charge. NOTE- The rate will be inclusive of scafolding for single or double storey including making hole in brick work and making good in cement mortar. |
| 107 | Clean existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and providing applying two coats of rust remover and two coats of alkaline rust converting primer/zinc primer and form a corrosion resitant, insoluble and adherent protective layer, including cleaning the reinforcement, with wire brushing to remove loose rust spalls, with time interval of 1 hour between the coats use, in slab/ roof projection, canopy etc, complete all as specified and directed. |
| 108 | Providing and applying, brush application, curing to form anticorrosive with high bond strength of anticorrosive polymer modified cementitious coating for corrosion inhibiting protection of reinforcement in one layers of total thickness of 2 mm in slab/ roof projection, canopy etc, complete all as specified and directed. |
| 109 | Rebuilding the section of damaged RCC elements to its original size or as directed by Engineer-in-Charge in thickness not exceeding 60 mm in layers of min thickness exceeding 20 mm and avg thickness 40 mm each by providing and applying ready mixed duel shrinkage compensated thixotropic mortar (PMM) of minimum grade M40 and above, including all lead lift, mixing by addition of water only as per manufacture's recommendation, levelling the surface, curing, formwork in slab/ roof projection, canopy etc, complete all as specified and directed. |
| 110 | M&L cement concrete Type B1 1:2:4 (20 mm graded aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 111 | S&F in repair Stainless steel plate rack of size (900mm x 750mmx250mm ) made out of AISl 304 stainless steel 0.63 mm thick sheet fixed with screw of required size including necessary fittings/nuts, bolts & washers complete all as specified and directed. |
| 112 | Supply and fixing in repairs CP wall mixture, valve cast copper alloy fancy type for mixture hot and cold water screwed down high pressure with capstan head screwed both ends for iron pipe 15mm bore dia complete all as specified and directed. |
| 113 | S&F 150mm size stainless steel bright finish handle as approved by GE, fixed with Nut and bolt complete all as specified and directed. |
| 114 | M&L for Roughening surfaces of old concrete by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed. |
| 115 | M&L machine cut kota stone, stone slab flooring 20-25mm thick over screed bed 20mm thick in cement mortar 1:4 set, jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including, rubbing and granite polishing complete all as specified and directed. |
| 116 | Description all as per serial item No. 115 here-in-above but in vertical surface/ skirting complete all as specified and directed. |
| 117 | S&F telescopic type side channel of drawer of standerd size incl roller for movig drawer made of mild steel bright finish or elctro galvanised (soft close ball bearing runner) with width of lap 30mm and 60mm long complete all as specified . |
| 118 | S&F Stainless Steel Plain Baskets of size 17''x22''x6'' complete all as specified and directed |
| 119 | S&F Stainless Steel Partition Baskets of size 17''x22''x6'' complete all as specified and directed |
| 120 | S&F Stainless Steel cutlery Baskets of size 17''x22''x6'' complete all as specified and directed |
| 121 | S&F Stainless Steel Plate Baskets of size 17''x22''x6'' complete all as specified and directed |
| 122 | S&F Stainless Steel Baskets of size 17''x22''x8'' complete all as specified and directed |
| 123 | Supply and laying in replacement of cable XLPE insulated armoured heavy duty electric cable with extruded insulation aluminium counductor, 1100 volts grade of cross sectional area 50 Sqmm 3.5 Core, complete all as specified and directed. |
| 124 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables, pipes etc and getting out in any type of soil complete all as specified and directed. |
| 125 | Returning filling in including spreading, leveling and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed. |
| 126 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 127 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed. Note: Punned thickness of sand shall be measured. |
| 128 | Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 129 | Material and labour for replacement of GI tubing light grade 50 mm bore for passing through cables under the floor, along the wall or along the pole complete all as specified and directed . |
| 130 | S&F GI tubing medium grade Galvanized of size 25 mm bore laid in trenches or ground/ in wall surfaces with and including all fitting complete all as specified and directed. |
| 131 | S&F GI tubing medium grade Galvanized of size 40 mm bore laid in trenches or ground/ in wall surfaces with and including all fitting, all as specified by Engr-in-charges. |
| 132 | M&L for cutting existing GI/CI pipe line of size 40/25 mm dia pipe making new connection for GI pipe including short pieces , inserting tees, bends ,sockets, union etc with existing water line, complete all as specified and directed |
| 133 | S&F stop valve 25 mm dia cast copper alloy screwed on high pressure with crutch or butterfly handle screwed bolts ends, for iron pipe or for union and fixed complete all as specified and directed. |
| 134 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed |
| 135 | Taking down distribution boards/wooden board ,switch fuse units,steel enclosures for MCB of any type and removing from site complete all as specified and directed. |
| 136 | Taking down existing unserviceable submain wiring of any size and making good the disturbed surface complete all as specified and directed. |
| 137 | M&L for modular point wiring for one light point controlled by one way switch with 1.5 sqmm (nominal area) PVC insulated FRLS and unsheathed multistranded copper conductor cable 1100 volts grade drawn through and including PVC rigid concealed conduit not less than 1.8 mm thick (ISI marked) with all accessories including suitable modular plate (Inner + Outer) and modular metallic boxes of suitable sizes including 1.5 sqmm PVC FRLS insulated unsheathed copper conductor multistranded cable for continuous earth conductor connected to common earth dolly, complete all as specified & directed.Note:- Proper colour coding is to be followed as per IS Specification. |
| 138 | All as per item No. 137.00 here-in-before but for one light point controlled by two switch 6 Amp SP, two way, 240 Volts. |
| 139 | All as per item No. 137.00 here-in-before but for one 5 pin 6 Amp socket outlet point on same board controlled by one way switch SP, one way 6 Amp, 240 Volts |
| 140 | All as per item No. 137.00 here-in-before but for one 5 pin 6 Amp socket outlet point on independent board controlled by one way switch SP, one way 6 Amp, 240 Volts |
| 141 | All as per item No 137.00 here-in-before but using 2.5 Sqmm (nominal area) multistranded copper conductor cable including 2.5 Sqmm size FRLSH PVC insulated and sheathed copper conductor cable as earth conductor (green colour) connected to common earth dolly for one 6 pin socket outlet 16 Amps multi purpose on independent point complete all as specified and directed. |
| 142 | All as per item No 137.00 here-in-before but using 4.00 Sqmm (nominal area) multistranded copper conductor cable for geyser sheet metal plug socket outlet/metal plug top including 4.00 Sqmm size FRLSH PVC insulated and sheathed copper conductor cable as earth conductor (green colour) connected to common earth dolly for geyser on independent point complete all as specified and directed. |
| 143 | M&L in replacement of Sub main wiring in two single run FRLS PVC insulated cable 6 Sqmm (Nominal dia) copper conductor (multistrand) and drawing in and including new PVC concealed non metallic conduit pipe ISI marked including one run 6 Sqmm multistranded copper conductor FRLS PVC green colour insulated unsheathed cable for earth continuity complete all as spd and directed. |
| 144 | M&L for Modular switch piano flush button SP, 1 way 5/6 amps 240 volts with polycarbonate body. |
| 145 | M&L for Modular switch piano flush button SP, two way 5/6 amps 240 volts with polycarbonate body. |
| 146 | M&L for Modular switch piano flush button single pole one way 15/16 amps 240 Volts with polycarbonate body. |
| 147 | M&L for Modular socket out let, 6 pin 5/6 and 15/16 amps multipurpose, 2 module 2 in 1 flush type, 240 volts with polycarbonate body. |
| 148 | M&L for Modular socket 2 in 1, 6 amps 2/3 pin Combined 2 Module , 240 volts. with polycarbonate body. |
| 149 | M&L for Modular bell push flush button,SP one module 5 amps 240 volts with polycarbonate body. |
| 150 | S&F in replacement of MCB Protected Socket With sheet steel Enclosure single pole 20 Amp with 3 pin plug top for AC connection from Socket point to stabilizer complete all as specified and directed. |
| 151 | S&F in replacement of Bell Ding Dong, AC 230 volt, Single Pole complete all as spd & directed |
| 152 | S & F in replacement of lamp holder batten type polycarbonate body with back plate for batten fitting, fixing with proper round block all as directed by Engr-in-Charge. |
| 153 | Supply and fixing in replacement of LED Lamp 9/10 watt B-22 holder base with polycarbonate body and aluminium heat sink warm white complete all as specified and directed by Engineer - in - Charge. |
| 154 | M&L in replacement of ceiling rose surface bakelite 2 to 3 terminals with polycarbonate body complete all as specified and directed. |
| 155 | S & F of decorative wall light white in colour made up of polycarbonnate body suitable for and including 9 watts retrofit LED lamp B 22 Base complete all as specified and directed. |
| 156 | S&F in replacment of LED lights fitting 1x 20W,minimum 3.5 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 157 | S&F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 158 | S&F in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 159 | S&F of 5 star rated BLDC (Brush less direct current motor) ceiling fan 230 volts, single phase of 1200 mm Sweep with regulator double ball bearing type with minimum air delivery 210 CFM with service value shall not less than 6.0 B.E.E including blade, down rod, canopy cover white colour etc, connecting 3 core flexible copper contuctor cable and dismantling of old unserviceable ceiling fans and depositing to MES store yard, complete all as specified and directed by Engr-in-Charge |
| 160 | S&F exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 161 | M & L for cutting hole in brick/stone masonary wall and provision of PCC 1:3:6 for making proper suitable size of hole to matching with size of exhaust fan for proper ventilation including MS bolts 04 Nos for fixing exhaust fan all as spd and directed.Note : (i) Rates are deems to be included to making the cutting hole smoothly and colour wash as per exisiting colour.(ii) Rates are deems to be including charges of hiring T & P, i.e. ledder square folding and insurance of labour deployed, being holes are made to be at mutlistorage bldgs of different height . |
| 162 | Supply and installing of the electric water storage heater of ABS body type of 25 ltr capacity with rated power 2 KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostate, indicators and temprature adjustable knob including steel braided flexible connection for pipe of size 15 mm dia bore with G I hexagonal adopters/Nuts on the both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangement and mounding wall with suitable size of anchor bolts with complete connection of water including testing after installation complete including dismantling of old unserviceable geyser and depositing to MES store yard all as specified and directed by Engr-in-Charge . |
| 163 | Taking down electric enerty meter single phase any size or type form the existing site and refixing the same at same place after carrying out necessary repair work and making the surface good to match with existing surface all as specified and directed by Engr-in-Charge. |
| 164 | Supply and fixing LED security light fittings 35 watt, IP 65 having pressure die cast aluminium alloy housing, prismatic polycarbonate cover complete including making connection with 3 core copper flexible cable of suitable size including galvanised iron pipe bracket 0.90 mtr long of 25 mm dia and fixing with bldg for fixing of street light fitting all as directed. |
| 165 | S & F SPN 8 way sheet metal enclosures factory made DB double door 230 V AC, 50 Hz AC 200 Amp rated bus bar complete all as specified and directed |
| 166 | S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 167 | S&F 240V, 10 KA 'B' curve miniaturecircuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 168 | S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 169 | S&F MCCB TP 125 Amp 415V 16KA fixed type suitable for VTPN DB complete with connection testing and commissioning complete all as specified and directed. |
| 170 | S&F VTPN DBs Double Door 4 way suitable for MCCB incomer, IP 43 protection 415 V AC, 50 Hz AC appropriate size of bus bar and neutral link complete all as specified and directed |
| 171 | M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cm X6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. all specified |
| 172 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail