| 1 | Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for. |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 3 | M & L Non Skid ceramic Coloured joint free tiles 7 to 8 mm thick ( square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of mortar with CM 1:4 complete all as specified and directed. |
| 4 | M&L for glazed ceramic tiles colour 350x250x7mm / 450x350x7mm thick in vertical surfaces such as skirting, dado and risers to steps set and jointed in neat cement slurry and pointed in coloured cement to match over 10mm thick cement mortar 1:4 on fair faces of brick work or concrete surfaces as backing for tiles complete all as specified. |
| 5 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed |
| 6 | M & L for 10 mm thick rendering on fair faces of brick work or concrete surfaces in CM in 1:6 finished even and fair without using etra cement.complete all as specified and directed |
| 7 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:4) two layer ( 10 mm+5mm) and finished even and smooth without using extra cement. including mixing of water proofing compound.Note :- Water proofing compound shall be measured & paid seperately.complete all as specified and directed |
| 8 | M & L for rendering 5 mm thick in C:M 1:3 on chajja,Ceiling in patches and finishes and smooth complete all as specified and directed |
| 9 | Supply only Integral Water proofing compound.complete all as specified and directed |
| 10 | M & L preparation of New plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge. |
| 11 | M & L preparation of New plastered surfaces of ceilig and applying three coats of white wash over resistant priming paint complete all as specified and as directed by Engineer-in-charge. |
| 12 | M&L for preparing of new plastered surfaces of wall and applying two coats of cement base paint, Priming plastered and other surfaces with alkaliresistant priming paint complete all as specified and as directed by Engineer-in-charge. |
| 13 | Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles |
| 14 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) all as specified |
| 15 | Taking down steel tubing and connections including cleaning for refixing or removal form site for 15mm bore pipe all as specified and directed by Engr-in-charge. |
| 16 | Taking down steel tubing and connections including cleaning for refixing or removal form site for 20mm bore pipe all as specified and directed by Engr-in-charge. |
| 17 | Taking down steel tubing and connections including cleaning for refixing or removal form site for 40 mm bore pipe all as specified and directed by Engr-in-charge. |
| 18 | Supply & laying of CPVC pipes 16 mm Outer dia, SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors ,complete all as specified and directed |
| 19 | Supply & laying of CPVC pipes 20 mm Outer dia, SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors complete all as specified and directed |
| 20 | Supply & laying of CPVC pipes 40 mm Outer dia, SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors complete all as specified and directed |
| 21 | M & L for cutting chases, pinning in brick walls/ stone concrete block or slab walls , making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings , steps, cills, sunshades, shelves, lintels etc; and cutting chases for concealed water tubing or cocealed conduit wiring, etc and making good , cutting not exceed 10 cm girth complete all as specified and as directed. |
| 22 | Taking down of eves gutter,rain water pipes of any size or pattern including all fittings etc complete all as specified and directed. |
| 23 | S&F, PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls |
| 24 | S&F, PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in walls |
| 25 | S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed. |
| 26 | S & F PVC (SWR) bends any radius, 75 mm bore |
| 27 | PVC (SWR) 110mm bore 'T' equal or unequal complete all as specified and directed. |
| 28 | S&F PVC (SWR) junction single, (single T) equal or un equal of 110 mm bore of pipe complete all as specified and directed. e. |
| 29 | S&F PVC (SWR) junction single, (single T) equal or un equal of 75 mm bore of pipe complete all as specified and directed. |
| 30 | PVC (SWR) floor trap / Nahani trap with grating 75 mm dia incl jointing with solvent cement complete all as specified and directed. |
| 31 | Taking down chowket or frame with shutter (without taking of shutters from the frames) of wooden door, steel windows/ventilators,PVC door etc, area not exceeding 1.5 Sq mtr each |
| 32 | Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
| 33 | S&F, Factory Made Solid PVC Moulded Door Shutters with wood free EPS 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face with particle board core, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by Engr-in-charge |
| 34 | S&F 75 mm long aluminium alloy type C-22 butt hinges with galvanised ms hinge pin etc. |
| 35 | S&F 150 mm long aluminium anodised barrel tower bolt and 12 mm dia fixed |
| 36 | S&F 150mm long aluminium anodised handle cast type and fixed |
| 37 | S&F in repair Chromium plated shower roses with or without swivel joints, anysize, including fixing to steel pipe or union all as specified and directed by Engr-in-charge. |
| 38 | S & F in repair for Bib taps, cast copper alloy with butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, 15 mm, fancy type, chromium plated fixed complete. |
| 39 | S & F in repair for Stop valves, cast copper alloy, screwed down, high pre-ssure, with butterfly handle, screwed both ends for iron pipe or for unions and fixed , 15 mm fixed complete. |
| 40 | S & F in repair for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed , 20 mm fixed complete. |
| 41 | S & F in repair for Grating doom 100 mm dia of chromium plated (Minimum weight 25gms) fixed complete. |
| 42 | S & F for Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats(Minimum weight 300gms) fixed complete. |
| 43 | S & F in repair for Soap dish, any type, fixed to plugs with chromium plated brass screws fixed complete all as specified and directed. |
| 44 | S&F in repair CP brass tubular towel rail 20 mm dia D type 60 cm long between flanges complete. |
| 45 | S & F for PVC connections 15 mm size with PTMT nuts of length 450 mm fixed complete all as specified. |
| 46 | S & F for vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) fixed in repairs complete. |
| 47 | S&F in rep Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) fixed as in repair, complete all as specified. |
| 48 | S&F in rep Vitreous china WHB 550x400mm on exsting brackets , fixing flat back or angle back type with PVC (hdpe) 32 mm dia waste pipe, brass coupling 32 mm CP etc complete all as specified and directed. |
| 49 | S&F PVC low level flushing cistern of capacity 10 litres complete with siphon handle lever float valve and PVC bend including connecting to ITWC/ ETWC and fixing on wall bracket complete all as specified and directed by Engr-in-charge. |
| 50 | S & F for 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed in repairs |
| 51 | M&L for Hard core, broken to gauge n exc 63 mm of broken stone boulders |
| 52 | M&L 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base of flooring etc,complete all as specified |
| 53 | M&L 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring etc,complete all as specified |
| 54 | M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection,flooring etc,complete all as specified |
| 55 | M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in CM 1:4 mixed with water proofing compound in cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed.(Note-WPC will be measurd and paid seprately) |
| 56 | Dismantling water tanks capacity exc 250 Ltr and n exc 500 Ltr and removing from site all as specified and directed by Engr-in-charge. |
| 57 | S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) capacity 1000 Ltr hoisted and fixed in position all as specified and directed by Engr-in-charge. |
| 58 | S&F in repair plastic water closet seat, white/black closet pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device. |
| 59 | M&L 75 mm thick as in sub base in CM 1:4:8 type D2(using 20 mm graded stone aggregate). |
| 60 | M & L providing, cement concrete type B1 1:2:4 (20 mm graded aggregatet)t in roof kerbs or mud stops, rounded or chamfered on edges |
| 61 | M&L for 50 mm thick Sand cushion under floors complete all as specified and as directed. |
| 62 | Excavating over areas, upto 3.0 m deep and getting out in any type of soil complete all as specified and directed by Engr-in-charge. |
| 63 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out,sof/loose soil, as directed by Engineer-incharge |
| 64 | Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 150 mm internal dia of pipe complete all as specified and directed. |
| 65 | Supply, laying and testing of 150 mm inner diameter of double wall corrugated (DWC) high density polethelene pipes(HDPE) and stiffness class-8 (SN-8) with ISI marked (with CML No) with and including all fittings & jointing materials for sewage lineand laid in trenches as specified in IS-16098(Part-2):2013 and as per manufacturer's instruction complete all as specified and as directed. Note:- Bedding of pipe shall not be provided in normal condition and construction methods shall be strictly compiled as per clause no A-4 Annex 'A' of IS 16098(Part-2):2013 |
| 66 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm |
| 67 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 68 | M&L for RCC(Nominal mix) type B1, (1:2:4) 20mm graded aggregates as in Slabs supported on walls, beams and columns in floors, roofs, chajjas,lintel, landings, balconies, canopies, deck slabs and in shelves and the like |
| 69 | M&L for Mild ctd steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to TMT steel of grade Fe 500/Fe 500 D/Fe 550/ Fe 550 D meeting all requirements of IS 1786 |
| 70 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs,chajjas, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces |
| 71 | M&L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment, confirming to IS 15658-2006of 60mm thickness M 35 Grade complete all as specified and as directed. Please Enable Macros to View BoQ information |