| 1 | Dismantling of Asbestos cement (corrugated, semi-corrugated etc) sheets in roof coverings complete all as specified and directed. |
| 2 | S&F in repair Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 3 | S&F in repair Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,eaves etc fixed with self tapping screws complete all as specified and directed. |
| 4 | Demolation of wall and ceiling boards (Fibre, pulp, insulation etc) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 5 | Providing and fixing false ceiling in repair of designer tile ivory painted (high pressure steam cured ) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level. Suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs)consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaecd between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width complete all as specified and directed. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 7 | M&L for Non- skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 8 | M&L in repair glazed coloured ceramic tiles in vertical surface such as skirting,dado and risers to steps of siize 350x250x7mm / 450x 350 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match existing surface including 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed.Note : Item may be repaired to be done in patches also) all as specified and directed. |
| 9 | S&F for powder coated aluminium sliding windows two track with two sliding shutters with extrusions aluminium of following sections including jointing cleats, glazing clips, rubbr packaging, snap beading and other necessary builders hardware as required complete all as specified and directed. (A) FRAME:-(i) Top and side member for two track frame of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.784 kg/ mtr), Model No. 20829 of Jindal or equivalent as specified in PS.(ii) Bottom rail of frame for sliding of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.909 kg/ mtr), Model No. 20830 of Jindal or equivalent as specified in PS.(B) SHUTTER:-(i) Top and bottom rail of sliding shutter of size 40 mm x 18 mm x 1.5 mm (weight 0.547 Kg/ mtr), Model No. 20736 of Jindal or equivalent as specified in PS.(ii) Side of sliding shutter with handle and self locking arrangement, section of size 40 mm x 18 mm x 1.5 mm (weight 0.547kg/ mtr), Model No. 20738 of Jindal or equivalent as specified in PS.(C) Sliding shutter to be provided with 5.0 mm thick sheet glass complete all as specified and directed.(D) Supply & Fix for 6.5 mm thick aluminium diamond grill with mill finished fixing on wall/wooden chowkhat/ aluminium frame with suitable size of aluminium 'U' channel and steel chromium plated, screw with rawel plug complete all as specified and directed with following details:- (i) Aperture size of aluminium grill 67 mm x 84 mm. (ii) Cord dimension 7 mm x 5.8 mm. (iii) Plate thickness 2 mm.(E) Supply & Fix for Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm fixed with galvanised wire staples/ clip/ aluminium flat, complete all as specified and as directed. |
| 10 | Taking down and refixing in the same opening ,resecuring or easing & adjusting of shutters exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed. |
| 11 | Taking down chowkats or frames n.exc 1.5 Sqm each with shutters without taking off shutters from the frame complete all as specified and directed. |
| 12 | Taking down shutters of any description n.exc 1sqm each including removing to or from store complete all as specified and directed. |
| 13 | Taking down and Refixing in other opening, Resecuring or easing & adjusting shutters of any description n.exc 1.0 sqm each complete all as specified and directed. |
| 14 | Taking down and refixing in same opening, Resecuring or easing & adjusting shutters of any description n.exc 1.0 Sqm each including removing to store complete all as specified and directed. |
| 15 | Hacking out old broken glass any thickness, size quality or description from wooden/steel frame fixed in repair with wooden beads/metal pinning and S&F 4 mm thick sheet glass in square n.exc 0.50 Sqm in each pane, fixed with wooden beads or putty (in metal frames etc) complete all as specified and directed. |
| 16 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm and n.exc 4 sqm each, making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 17 | Taking down shutters of any description n.exc 1sqm and n.exc 2 Sqm each including removing to or from store complete all as specified and directed. |
| 18 | S&F for 35mm thick factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 19 | S&F for 75mm butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 20 | S&F for 100mm butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 21 | S&F for 100 mm aluminium handles, cast type, anodised complete all as specified and directed. |
| 22 | S&F for 2nd class HW plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 23 | Dismantling of timber scantling 40 sq.cm and over in section, in any section in framed work complete all as specified and directed. |
| 24 | S&F for 30mm th, factory made 2nd class HW glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete all as specified and directed. |
| 25 | M&L in repair for second class hardwood clean sawn in scantling timber framed and fixed including replace old and decayed timber (including piecing, scarfing etc of old and new member if required and removing defective portions to store complete all as specified and directed. |
| 26 | Demolition of reed, lathing, singleor double, including battens and plaster or chicken wire mesh complete all as specified and directed complete all as specified and directed. |
| 27 | M&L in repair for rendering 15mm thk in cement mortar 1:4 in two layers (10+5)mm mixed with water proofing compound@ 3% by weight of cement in top 5mm thk finishing the surface with fair and even without using extra cement complete all as specified and directed.Note :- Water proofing compound shall be measured and paid separatly. |
| 28 | M&L in repair for rendering 20 (15+5) mm thk cement plaster on other side of lathing plastering in cement mortar 1:4 with complete framing with shuttering as one side fair and plastering with other side as fair finish from other side complete all as specified and directed. |
| 29 | S&F for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc including all laps, cutting and waste complete all as specified and directed. |
| 30 | M&L for preparation of new plaster surfaces(external face) of wallss and applying two coast of all weather cement based paint over alkali resistant priming paint complete all as specified and directed. |
| 31 | M&L for preparing new surfaces and applying two coats of distempering walls with distemper oil emulsion, white or tinted complete over chalk whitening, on plastered surfaces to internal walls complete all as specified and directed. |
| 32 | Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc 15 cm thickness (below or above ground level) including removal of debries out side defence land complete all as specified and directed. |
| 33 | M&L for 75 mm thick, PCC (1:3:6) type C-2 using 20 mm graded stone aggregate as in plinth protection for finish even and smooth without using extra cement complete all as specified and directed. |
| 34 | M&L for hardcore of gauge n.exc 63mm, deposited,spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 35 | Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 36 | M&L for rendering 15mm thick in cement mortar (1:4) on brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 37 | Supply only IWC (integral water proofing compound) at the rate of 3% by weight of cement complete all as specified and directed. |
| 38 | M&L for Fe410-W(Gde-250)quality B tubular roof truss (framed), trussed, prulins, crane gantries, rails and fasteining and heavy bracket framing (beams, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 39 | Dismantling wrought iron or mild steel work of any description and in any position complete all as specified and directed. |
| 40 | M&L for 25 mm thick cement concrete type B0 1:2:4 using 12.5 mm graded aggregate as a sub base for levelling complete all as specified and directed. |
| 41 | M&L for 100 mm thick cement concrete type D2 1:4:8 using 40mm graded aggregate as a sub base for levelling complete all as specified and directed. |
| 42 | M&L for preparation of new surfaces steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide primer complete all as specified and directed. |
| 43 | M&L for preparation of old surfaces steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying single coats of Synthetic enamel paint (Ordinary tint) complete all as specified and directed. |
| 44 | M&L for Preparing surfaces of wood and wood based material, new or old of any description and girth, not other wise described and treated with single coat of creosote oil complete all as specified and directed. |
| 45 | S&F for expanded metal ,cut to length, bent to shape required and tyjing with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples to wood or steel members including removal of existing complete all as specified and directed. |
| 46 | M&L for preparation of old decorated plastered surfaces of walls and applying two coats of white wash complete all as specified and directed. |
| 47 | M&L for Preparation of old decorated plastered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of distemper oil emulsion complete all as specified and directed. |
| 48 | M&L for preparation of new surfaces wood and wood based surfaces of any description ,not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer complete all as specified and directed. |
| 49 | M&L for preparation of old surfaces wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer complete all as specified and directed. |
| 50 | M&L for brick work inburnt brick with sub-class ‘B' old size bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 51 | Demolition Brickwork or stone/ boulder masonry, built in cement/lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 52 | Taking down carefully copper/aluminum point wiring (light ,fan and power socket etc) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, calling bells etc removing materials for taking credit and making good matching to the existing colour to the disturbed surface wall/ floors etc complete all as specified and directed. |
| 53 | Taking down the existing unservicable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 54 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 55 | Taking down carefully ceiling fan, sealing cable ends,dismantelling blades removing fan and blades for taking to store and refixing back to its original position and making good matching to the existing colour to the disturbed surface wall/ floors etc complete all as specified and directed. |
| 56 | M&L for point wiring with 1.5 sqmm cable PVC insulated unsheathed type, copper conductor, multistranded cable (FRLS type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 1.5 sqmm copper conductor, multistranded cable (FRLS type) 1100 Volts grade unsheathed PVC insulated (green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including PVC casing capping, medium grade of suitable size including all fittings such as bend, elbow, tee, joint etc with sunk cast pressed steel terminal box made out of MS sheet with 3 mm thick hylum laminated sheet cover for mounting of switch, socket and fan regulator complete all as specified and directed for following:- |
| 57 | Light/Fan point controlled by one no one way switch. |
| 58 | All as per item Srl No. 56, but 5 Amp Socket on Same board |
| 59 | All as per item Srl No 56, but 5 Amp socket point on independent switch board. |
| 60 | All as per item Srl No. 56, but with 2.5 Sqmm cable for one 16 A socket point on independent board complete all as specified and directed. |
| 61 | S&F for switch piano flush type 1 way 5/6 Amps,230 volts, 50 HZ complete all as specified and directed. |
| 62 | S&F for switch socket combination 3 pin 5/6 Amps, piano flush type 230 V complete all as specified and directed. |
| 63 | S&F for switch socket combination, multipurpose type 6 pin 6/16 A 240 Volts piano flush type complete all as specified and directed. |
| 64 | S&F for ceiling rose surface type bakelite 3 terminals 230 volts AC complete all as specified and directed. |
| 65 | S&F for step type electronic fan regulator piano flush type, 230 volts, 5 speed control complete all as specified and directed. |
| 66 | S&F for LED lights fitting 1 X 20 W, 220V, AC Inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours. Model Ordering decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old one complete all as specified and directed. Make Crompton cat part No LHEXACP7FN1W020. |
| 67 | S&F in repair / replacement of lamp holder with 9 watt LED bulb PVC / polycarbonate type with back plate straight or angular, 230 volts suitable for batten fitting complete all as specified and directed. |
| 68 | S&F for LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make Crompton cat part No ERP-427-35-57-HL2-LM-NBK. |
| 69 | S&F for sheet metal enclosure, MCB DB, double door, single pole & neutral, 12 way, 230 volts, 50Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 70 | S&F for MCB SPN 32 Amps, 230 volts, C - curve, 10 kA complete all as specified and directed. |
| 71 | S&F for MCB SP 10 to 32 Amps, 230 volts, C curve, 10 kA complete all as specified and directed. |
| 72 | S&F for MCB TPN 40 to 100 Amps, 230 volts, C curve complete all as specified and directed. |
| 73 | S&F for sheet metal enclosure MCB DB TPN double door type AC 415 V 4 way with 200 Amps rated bus bar, vertical/horizantal type including taking down old one complete and making good of disturbed surface complete all as specified and directed. |
| 74 | S&F in repair / replacement of submain wiring with 2 X 2.5 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 2.5 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 75 | S&F in repair / replacement of submain wiring with 2 X 4.0 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 4.0 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 76 | M&L in repair of earthing complete with galvanised steel earth plate electrode 600mm×600 mm× 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point/ DB including necessary earth work, common salt, char coal and earth pit as per electrical plate No. 3 of SSR Part-I complete all as specified or indicated point including testing on completion complete including dismantling old complete all as specified and directed. |
| 77 | Excavation in trenches n.exc 1.50 mtr wide and n.exc 1.50 mtr deep for taking out/ laying of under ground cable, pole, pipe, stay and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed. |
| 78 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm spread any type of soil complete all as specified and directed. |
| 79 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and directed. |
| 80 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as specified and directed.Note: Punned thickness of sand shall be measured & paid. |
| 81 | M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified and directed. |
| 82 | M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing upto 50 mm bore complete all as specified and directed. |
| 83 | S&F in replacement GI protection pipe of 40 mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole/ walls with mild steel clamps, bolts, nuts and washers complete all as specified and directed.Note:- Earth work shall be measured and paid separately. |
| 84 | Taking out old serviceable/ unserviceable cable of size 25 Sqmm, 3.5 core of any make/ type for requisite replacement/ further disposal complete including taking out bricks complete all as specified and directed. |
| 85 | Supply, fixing/ laying, connecting and commissioning LT underground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable with multistranded aluminium conductor,10 sqmm, 4.0 core, 1100 Volts grade laid in trenches/ on wall/ poles/ ducts/ pipe including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and directed.Note: Earth work shall be measured & paid separately. Material and labour laying well burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. Please Enable Macros to View BoQ information |