| 1 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 2 | Dismantling timber scantlings 40 sqcm and over in section as in framed work in any position complete all as specified and directed.. |
| 3 | Dismantling of wall and ceiling Boards(Fiber,pulp, Insulation etc) or insulation Board/slab/blankets any Thinkness including cover fillets complete all as specified and directed. |
| 4 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing |
| 5 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 6 | Taking down chowkats or frames not exc 1.5 Sqm each with shutters ( with out taking off shutters from the frames) complete all as specified and directed. |
| 7 | Taking down chowkats or frames exc 1.5 sqm but not exc 4.0 Sqm each with shutters ( with out taking off shutters from the frames) complete all as specified and directed. |
| 8 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 9 | M&L fly ash Brick work using modular size bricks with sub class 'B' bricks curved on plan with mean radius not exc 6m with bricks roughly cut to radius or bricks with wedge shaped joints built in cement mortar 1:4 complete all as specified and directed. |
| 10 | M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed Note - Reinforcement and form work shall be measured and paid separately. |
| 11 | Form work to sides of concrete foundation ,footings, bases of columns, raft and raft beams sides and soffits (if any )of foundation and plinth beams for flat rough finished concrete surface complete all as specified and directed. |
| 12 | M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 13 | Form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressummers, lintels, cantilevers, shelves, for flat rough finished concrete surfaces complete all as specified and directed. |
| 14 | M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in chajjas and similar work complete all as specified and directed.Note - Reinforcement and form work shall be measured and paid separately. |
| 15 | Form work to chullah hood, chajjas, troughs and similar items including edges etc for rough finished flat concrete surface complete all as specified and directed. |
| 16 | Excavation in soft / loose soil for post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed. |
| 17 | M&L Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 18 | M&L Mild Steel TMT bar 5mm dia and over upto and including 10mm dia as in stirrups, spacers & binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 19 | M&L Mild Steel TMT bar 6 to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 20 | M&L for external rendering 15 mm thick in two layer, first layer shall be of 10 mm thick CM 1:6 and second layer of finishing coat shall be 5 mm thick in CM 1:4 mixed with WPC @3% by weight of cement on brick work or concrete surfaces of wall and finished even and fair complete all as specified and directed.Note-WPC shall be measured and paid seperately. |
| 21 | Supply only liquid proofing compound all as specified and directed. |
| 22 | M&L for rendering 10 mm thick in CM 1:6 on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement complete all as specified and directed. |
| 23 | S&F steel work in Hollow section Square/rectangular as in roof truss ,purlin,rail etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St -240 and painted one shop coat of zinc chromate primer paint including preparation of surface at contractor workshop before fabrication complete all as specified and directed. |
| 24 | S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes ,without and attachment of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed. |
| 25 | S&F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long |
| 26 | S&F mild steel flat iron as in bands straps, supports or stays for rainwater, ventilating pipes including bolt if required, hooks (stay) heavy for large gates,hook and pintle hinges,large hasps and staples, hold fasts, wall ties, hooks for hanging fans ,cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 27 | S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/ eaves board fixed with selp tapping screw complete all as specified and directed. |
| 28 | S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/eaves board fixed with selp tapping screw complete all as specified and directed. |
| 29 | S&F Anodised aluminium snap grid frame work for false ceiling all as specified and as directed |
| 30 | M&L for non Asbestos ,fibre reinforced standard cement board as in celiling ,4mm thick designer board (610mm x 610mm ) complete all as specified and as directed |
| 31 | Demolation of un-reinforced cement concrete in ground floors and pavings not exc 15 cm in thickness (below or above ground level) as directed |
| 32 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in floor finishes 40 mm thick finished even and smooth without using extra cement complete all as specified and directed. |
| 33 | M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 34 | M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in vertical surface /skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. |
| 35 | S&F pressed steel frames of size 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including one shop coat of priming complete all as specified and directed. |
| 36 | M&L for PCC 1:3:6 type C-1 (using 20mm graded aggregate) as in hold fast block including necessary form work etc complete all as specified and as directed. |
| 37 | S&F 35 mm thick second class hard wood rail and style plain framed factory made panelled shutter (two panel) with lock rail and panel of 9 mm BWP commerical ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 38 | S&F aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy of 250 mm length of bolt complete all as specified and directed. |
| 39 | S&F aluminium, anodised, barrel tower bolts of extruded section 150 mm long complete all as specified and directed. |
| 40 | S&F aluminium handles cast type anodised of 150 mm size complete all as specified and directed. |
| 41 | S&F Powder coated aluminium window sliding type three track (2 glazed & one gauze shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing , screws, handle, locking arrangement and 4 mm thick plain/tinted glass and aluminium mosquito proof gauge complete all as specified and as directed. |
| 42 | S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,frame work of watertanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 43 | Material and Labour for preparation of new plastered surfaces and applying of two coats of cement base paint of wall surfaces complete all as specified and directed. |
| 44 | M&L for applying two coats of acrylic distemper on newly plastered wall surface including preparation of surface over a coat of 1mm thick Birla wall care putty complete all as specified and directed. |
| 45 | M&L of two coat of synthetic enamel paint over one coat of red oxide on new steel surfaces of any description over 10cm in width or girth incl preparation of surfaces complete all as specified and as directed. |
| 46 | M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 47 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 48 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be sone through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for the following :- |
| 49 | (a) One light point controlled by one way switch 5/6 amps. |
| 50 | (b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps. |
| 51 | (c) One socket out let 5/6 amps point on the same board |
| 52 | (d) One socket out let 5/6 amps point on the independent board |
| 53 | All as per item No 48 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed. |
| 54 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 55 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed. |
| 56 | S&F of socket outlet 2 in 1, 5 Pin, 5/15 amp, multipurpose 230 volt flash type complete all as specified and directed by Engr-in-Charge. |
| 57 | S&F switch piano flush type 15/16 amps single pole one way complete all as specified and directed. |
| 58 | S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed. |
| 59 | S & F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed Make : Havells Reo. |
| 60 | S & F stepped type electronic fan regulator not less than 80 watt complete all as specified and directed. |
| 61 | S & F Wall monted slim LED inverter batten 20W 4' long,min output 120 Lumen/watt PF>0.95,surge protection,> 4KV, THD:<10% with PC housing, with integrated LED driver complete all as specified and directed by Engr-in- charge.Cat part No MAKE :HPL HPLLEDINVT5BPC20CW |
| 62 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 63 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size |
| 64 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), Single door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 65 | S&F MCB Triple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 66 | S&F MCB, Single pole & neutral 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 67 | S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 68 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge. |
| 69 | M & L Sub main wiring concealed type with two run single core cable PVC insulated cable with 2x4.0 sq. mm +1x4.0 sq. mm earth wire (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size, making good the disturbed surfaces complete.(NOTE : Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length.) . |
| 70 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified and as directed. |
| 71 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation of poles/stays/cables etc and getting out in any type of soil. |
| 72 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers n.exc 25cm. |
| 73 | Removing excavated material n.exc 50m and depositing were directed at a level n.exc. 1.5m above the starting level. |
| 74 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I) |
| 75 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed by Engr-in-Charge. |
| 76 | Supply and fixing 40 mm dia GI tubing medium grade ISI marked laid in trenches / laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified and directed. Please Enable Macros to View BoQ information |