| 1 | Taking down chowkats or frames exc 1.5 Sqm and n.exc 4 Sqm (without taking off shutter from the frames) and removal from site. |
| 2 | All as item No 1 here-in before but n.exc 1.5 Sqm each. |
| 3 | Taking down shutters and refixing in same opening of any description exc 1 Sqm but not exc 2 Sqm each complete all as specified and directed. |
| 4 | Taking down cement plaster any description on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwiseprovided for grils.rails etc |
| 6 | Demolition of brick walling built in cement mortar etc complete all as specified. |
| 7 | Demolition of cement concrete of any position and description. |
| 8 | Hacking out of old broken glass any thickness size quality or description from metal frame including punching or drilling out old glazing pins. |
| 9 | Demolition of reinforced cement concrete in any description and in any position (reinforcement cut as required to facilitate demolition). |
| 10 | Dismantling old PGI/CGI/Asbestos sheeting any gauge, thickness, including Nainital. Sikkim or similar pattern roof/facia etc complete. |
| 11 | M&L for providing machine cut polished Kota stone slab 18-20mm thick over cement screed bed and laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 15mm thick screed bed complte. |
| 12 | All as per item No 11 but in narrow width of vertical surfaces. |
| 13 | M&L for pre-painted galvalume aluminium zinc coating GI based Corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering fixed with self tapping screws/J hooks as specified. |
| 14 | M&L for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering , eaves boards, velly gutter, and other similar works fixed with self tapping screws/J hooks complete all as specified and as directed. |
| 15 | M&L 75mm thick PCC (1:3:6) type C2 as in plinth protection using 40mm graded stone aggregate finishing cement concrete surface even & smooth without using extra cement including bitumen filling in two panel etc complete all as specified and as directed. |
| 16 | M&L for 25 mm thick PCC (1:2:4) type B1 ( 20mm graded stone aggregate) , finished concrete surfaces even and rough to receive floor finishes. |
| 17 | M & L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, Copping, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 18 | M & L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (20 mm graded stone aggregate) for chujjas. |
| 19 | S&F for pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 105 x60 mm |
| 20 | S&F for pressed steel frames for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125 x60 mm |
| 21 | M&L for plain, framed, factory made panelled shutters 35 mm thick (any number of panels) , with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats. |
| 22 | S&F second class hardwood, factory made glazed and skelton shutters 35 mm thick open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I Section8, Clause 8.20 (a) supplied and fitted to chowkats. |
| 23 | S&F of factory made steel windows with side hung shutters openable type including friction/projected type hinges steel handle and peg stay complete without glazing bars fixed to existiog opening and making to match as per existing surfaces. |
| 24 | S&F of factory made steel windows with side hung shutters openable type including friction/box type hinges steel handle and peg stay complete with glazing bars fixed to existiog opening and making good to match as per existing surfaces including taking out old/unserviceable steel windows. |
| 25 | S&F of 3mm thick sheet glass panes ordinary quality n.exc 0.5sqm each fixed to steel frame complete with oil putty in square including steel pin. |
| 26 | S&F Framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted,or forged into spikes; framedguard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 27 | M&L brickwork with sub class B bricks straight or curved on plan exc 6mtr mean radius built in cement mortar 1:6 by using old size bricks complete. |
| 28 | M&L for brick work with sub class 'B' bricks using old size bricks, straight or curved on plan to any radius, built in CM 1:4 as in half brick thick wall complete all as specified and directed. |
| 29 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar (1:6) finished even & fair. |
| 30 | M&L for rendering 20mm thick in cement mortar 1:4 in two layers of 10mm each using WPC in finishing layer on brick or concrete surfaces finished even & fair (WPC for finishing layer will be paid seperately as supply only). |
| 31 | Supply only liquidl water proofing compound. |
| 32 | M&L for two coat of Oil boound distember on new wall surface including preperation of the surface over a coat of primer all as directed and specified. |
| 33 | M&L applying two coats of weather proof exterior emulsion paint of standard quality and make ,over a coat of white primer including preparation of new /old wall surfaces complete all as specified and directed. |
| 34 | M&L for two coats of synthetic enamel painting to new wooden surfaces over a coat of pink primer including preparation of surfaces area exc 10cm width & girth. |
| 35 | Material & labour for preparation of old painted surfaces of wood & wood based materials over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as directed by the Engr-in-Charge. |
| 36 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or girth |
| 37 | S & F for Anodised aliminium snap grid frame work for false ceiling confirming IS:733, 737 & IS:1285 ; all as specified and as directed. |
| 38 | S&F 4mm thick (E-Boards) Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws in ceiling complete all as specified and as dirceted. |
| 39 | M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. |
| 40 | M & L 80 mm thick M-35 grade factory made vibratory compacted cement concrete rubber moulded, interlocking paver block any shape and size confiroming to IS 15658-2006 with grey cement and pigment as approved laid over and incl 50 mm thick consolidated sand cushion and joints filled with sand complete all as specified and directd. |
| 41 | Material and labour for applying one coat of synthetic enamel paint on old painted steel and iron surfaces of any description over 10 cm in width or girth including necessary preparation of surfaces. |
| 42 | Complete removal of existing treatment from plastered or unplastered surfaces of walls including cleaning with scrapers, any number of coats and any width or girth etc and applying two coats of oil bound distemper over a coat of primer over super fine Birla or altek putty finish as required and complete all as specified and as directed by the Engr-in-Charge. |
| 43 | M& L for form work to chajjas and similar items including edges ,rough finished surfaces of concrete flat. |
| 44 | M&L for mild steel TMT bars,10mm dia and over cut to length, bent to shape required including cranking ,bending spirally, hooping for columns, hookings/ends and binding with and including MS wire not less than 0.9 mm dia or securing with clips. |
| 45 | M&L for mild steel TMT bars 6mm to 8mm dia cut to length , bent to shape required, including cranking , bending and binding with MS wire , not less than 0.9 mm dia or securing with clip. |
| 46 | M&L for MS flat iron bent to shape, holes drilled etc complete as in hold fast & wind ties etc including one coat of red oxide paint. |
| 47 | S&F of in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with tinned tacks,or galvanised wire staples.or wooden beadings for doors complete all as specified and directed. |
| 48 | M&L for 150 mm size aluminium anodised cast type handles. |
| 49 | S&F of 200mm long aluminium anodised,barrel tower bolt of extruded section. |
| 50 | S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete. |
| 51 | S&F 100mm size mild steel butt hinges medium weight. |
| 52 | S& F of 140 mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor |
| 53 | Dismantling timber scantlings under 40 sq. cm in fillets, rails, posts, rafters, purlins, section, in any position |
| 54 | M&L for mild steel rolled sections conforming to Fe - 410 (Gde E-250) as in main and cross beams, hip and jack rafters; verticals , purlins where connected to common rafter and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. |
| 55 | M&L 100 mm thick PCC (1:3:6) type C2 as in hard stanidng / footpath using 40mm graded stone aggregate finishing cement concrete surface even & smooth without using extra cement including bitumen filling in two panel etc complete all as specified and as directed. |
| 56 | Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound, grade A |
| 57 | Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ all as specfied and directed (250 mm thick concrete slab) |
| 58 | Material and labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and as directed. |
| 59 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc complete including taking out old unsv cable as specified and as directed.(NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'). |
| 60 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable complete all as specified and as directed. |
| 61 | Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed. |
| 62 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 63 | Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. |
| 64 | Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. |
| 65 | M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'. |
| 66 | M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed. Make: Tata/Jindal/Bansal |
| 67 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 68 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws (or provision of modular sunken box, modular back plate and top cover for housing of modular switch,socket, regulators etc as per site requirement) for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for the following :- |
| 69 | (a) One light point controlled by one way switch 5/6 amps. |
| 70 | (b) One ceiling fan point controlled by one way switch 5/6 amps. |
| 71 | (c) One socket out let 5/6 amps point on the same board |
| 72 | (d) One socket out let 5/6 amps point on the independent board |
| 73 | All as per item No 68 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed. |
| 74 | S&F Switch piano flush type 5/6 amps single pole one way complete all as specified and directed. |
| 75 | S&F Socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed. |
| 76 | S&F of Socket outlet 2 in 1, 5 Pin, 5/15 amp, multipurpose 230 volt flash type complete all as specified and directed by Engr-in-Charge. |
| 77 | S&F Switch piano flush type 15/16 amps single pole one way complete all as specified and directed. |
| 78 | S&F Ceiling rose, surface type with back plate, three terminal /PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 79 | S&F of S & F Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc 100/120 watt suitable for 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed. |
| 80 | S&F LED lights fitting 1x 20W, 220V AC decorative box type with driver,IP 20, class I, wall/ surface mounted, integrated type with extruded aluminium housing integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified. |
| 81 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection luminaire efficiency not less than 100 lumens/watts integrated high efficiency electronic driver and surge suppressor of 7.5KV or more power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz and necessary mounting arrangements, provision of new 2/3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting inlcuding MS Bracket & clamp necessary for fixing on wall complete all as directed by Engineer-in-Charge. |
| 82 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole & neutral with din rail, IP-20 protection suitable for fixing MCB\\"S/lsolators complete including provision of blanking plates as required and taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 83 | S&F MCB, Single pole & neutral 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 84 | S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘B’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 85 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge. |
| 86 | M & L Sub main wiring concealed type with two run single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size, making good the disturbed surfaces complete including necessary taking down.(NOTE : Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length. . |
| 87 | M&L for street light bracket made out of GI pipe light grade 32 MM dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.2 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 25 x 5 mm suitable length 2 Nos complete with drilling hole, fixing with runts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer. Please Enable Macros to View BoQ information |