| 1 | Dismantling floor, hearth or wall tiling incl cement mortar bedding and removing the rubbish off the premises complete all as specified and as directed . |
| 2 | M & L for Virified Ceramic double charges tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. . |
| 3 | M&L Virified Ceramic tiles double charge 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match vertical surfaces, in skirting etc. set and jointed in neat cement slurry and pointed in whiter or coloured cement to match including 15 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 4 | M&L in repair for suspended false ceilling system using metalic exposed suspende system, grid section size 600mm x 600mm comprising of GI powder coated main runner of dimension 39 mm x 24mm x 0.80mm thick ( thickness comprising of GI/0.4+ PPPCGS/0.3mm & weight of Runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X 24mm x 0.8 mm thick wall angle 22.2mm x22.2mm x 0.65 mm thick ( thickness comprising of GI/0.35 + PPPCGS/0.3 mm & Weight of angle 0.70 kg for 3050 mm length) with and including 6 mm thick designed prepainted calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid ( placed in the grid system duly suspended with 4 mm dia G I bars hangers fixed with steel dash through fasteners from purlins of the roof with necessary fittings and fixtures etc complete all as directed. |
| 5 | S&F hollow PVC Wall panneling with designed/printed panels having wide of 300mm including necessary caping/fillets at top, bottom and junctions/corners of wall where ever required as per site etc complete all as per specified and directed. |
| 6 | Taking down tar felt with cement plaster from roof surfaces and lowering and removing the same to a distance exc.500m and n. exc. 1.5 KM incl removal of finishes up to mother slab complete all as specified and as directed . |
| 7 | Dismantling of cement concrete of any size, position and any description complete all as specified and as directed. |
| 8 | M&L 25 mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) mixed with water proofing compound and laid on RCC slab as base layer for roof treatment roughening the top surface of concrete by using broom sticks while the concrete is green complete all as specified and as directed.(NOTE : water proofing compound paid separately under relevant item of this Schedule 'A'). |
| 9 | M & L for water proofing treatment to RCC roof slab as specified below and as directed by Engineer-in-Charge :- (a) 10 mm th cement plaster in CM 1:4 with integral WPC to be laid over the RCC roof slab when the concrete is green.(b) Applying a uniform coat of bitumen primer @ 0.70 kg/sqm over cement plaster.(c) 3 mm thick plain texture and weighing not less than 3.5 kg/sqm Atactic Polypropylene Polymer (APP) modified bitumen based prefabricated five layer water proofing membrane reinforced with non woven polyster matt black finished over compatible primer at 0.4 Ltr / sqm of density at 25 degree centigrade 0.87 - 0.89 kg/ltr and viscosity 70-160 cps or cold sticker and torch application of membrane with overlap while torching shall be 150 mm on length side and 100 mm on width side. after necessary preparation of surface complete as per manufacturers instructions.(d) Apply two coats of bitumastic - aluminium paint over the membrane. |
| 10 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified. |
| 11 | S&F in repairs power coated aluminium door shutter fixed including roller machine with rubber gasket, stopper, cleats, handles etc complete incl aluminium door styles of size 80 mm x 38 mm x 2.00 mm and aluminium door section of top, bottom and lock rail shutter frame of 80 mm x 38mm x 2.00 mm inlcuidng double action door spring hydraulically regulated made up of 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and all necessary fittinngsand EPDM rubber packing each shutter shall be provided with two decorative type aluminium disc handle of 150 mm dia per shutter ,1 no heavy duty door shutter 1no 200mm long aluminium tower bolt per shutter inlcluding taking down old door with necessary all fittingand all necessary fittinngs complete all as specified and as directed by the Engr-in-Charge. |
| 12 | S&F Powder coated aluminium sliding windows for three track with rubber gasket, stopper powder coated aluminium standard beads/glazing clips ,locking arrangement etc and aluminium frame of size 80mmX25mmX1.55mm and shutter of section 20mm X20mm X1.55mm incl ( two shutter of 4.8mm thick glass and one shutter of wiremesh 0.36 mm dia of wire and average width of aperture 1.40 mm) & aluminium grill of aperture size of grill 70mm including taking down old steel windows with necessary all fittings complete all as per manufacturer's instructions and all as specified |
| 13 | Taking down cement plaster any description on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc all as specified and directed. |
| 14 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar (1:6) finished even & fair etc all as specified and directed. |
| 15 | M&L for 5mm thick plaster rendering on fair faces of concrete surfaces as in ceiling in CM(1:3) finished even and smooth (without using extra cement) complete all as specified and as directed. |
| 16 | M&L for rendering 20mm thick in cement mortar 1:4 in two layers of 10mm each using WPC in finishing layer on brick or concrete surfaces finished even & fair (WPC for finishing layer will be paid seperately as supply only) etc all as specified and directed. |
| 17 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 18 | M&L preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed |
| 19 | M&L for complete removal of existing treatment of old plastered surfaces of ceiling and applying three coats of white wash all as specified and directed. |
| 20 | M&L for prepartion of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 21 | M&L for complete removal of existing treatment of old plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete removal of existing treatment all as specified and directed. |
| 22 | M & L for preparing new Plastered surfaces of walls and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm) etc all as specified and directed. |
| 23 | M & L for complete removal of existing treatment and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm) etc all as specified and directed. |
| 24 | M & L for 2 mm thick wall care putty (each of 1mm thick) in two layers etc complete all as specified & directed. |
| 25 | Dismantling of Concrete in ground floors and pavings n exc 15 cm thickness any description complete all as specified and as directed. |
| 26 | M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. |
| 27 | M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in path /steps laid with and incl use and waste of form work and finishing the surface even and rough to receive the topping layer or tiling complete . |
| 28 | M & L 60 mm thick M-30 grade factory made vibratory compacted cement concrete rubber moulded, interlocking paver block any shape and size confiroming to IS 15658-2006 with grey cement and pigment as approved laid over and incl 50 mm thick consolidated sand cushion and joints filled with sand complete all as specified and directd. |
| 29 | M & L for PCC 1:2:4 type B-I ,(using 20 mm graded stone aggregate) as. in coping /benching to sides of foot path fininished fair and even including necessary formwork etc complete all as specified and direected. |
| 30 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 31 | M&L Point wiring for Point controlled by one moduler switch with 1.5 sqmm PVC insulated FRLSH unsheathed copper conductor single core multi stranded flexible copper cable in and including not less than 20 mm dia non metallic rigid PVC conduit ( ISI marked ) concealed in wall with 1.5 mm thick pressed steel terminal boxes ( modular type ) concealed in walls painted the same inside and out side with one coat of black bitumen paint incl inner and outer moduler plate for fixing of modular switches/ regulator etc along with PVC insulated and insheathed FRLSH 1.5sqmm multi stranded copper conductor cable (green color) as earth lead as directed by Engr- in- charge. |
| 32 | (a) One light point controlled by one way switch 5/6 amps. |
| 33 | (b) One ceiling fan point controlled by one way switch 5/6 amps. |
| 34 | (c) One socket out let 5/6 amps point on the same board |
| 35 | (d) One socket out let 5/6 amps point on the independent board |
| 36 | All as per item No 31 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed. |
| 37 | S&F of Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 38 | S&F of Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed. |
| 39 | S&F of Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed. |
| 40 | S&F of Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 41 | S&F Ceiling rose, surface type with back plate, three terminal /PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 42 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling,IP 20, class I, integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz complete all as specified. |
| 43 | S&F LED Bulk Head lights fitting 1x 9/10W, 220V AC integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz fixed etc connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified. |
| 44 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp,IP 20, class I, wall/ surface mounted, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 45 | S&F Decorative luminiare suitable for wall light fixture including LED lamp 1x19 watt ( B-22 base) ,made of unbrakeable Polycarbonate with Acrylic decorative diffuser, IP-65 protection, and provision of PVC insulated sheathed round flexible wire with multi stranded copper conductor of size 1.5 Sq mm two core complete all as specified and directed Make : Havells, cat part No.LHDL06160099 or equivalent of Philips/Bajaj. |
| 46 | S & F Fan Moduler step type regulator, 120W - 2 module AC 50 Hzs white/ivory finish complete all as specified and directed. |
| 47 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F MCB, Single pole & neutral 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 49 | S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘B’ curve, 10 KA all complete including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 50 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge. |
| 51 | M & L Sub main wiring concealed type with two run single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size, making good the disturbed surfaces complete including taking down old submain wiring.(NOTE : Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length.) . |
| 52 | Taking down fan, sealing cable end,dismantling blades and removing fan and blades to store and Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust and minor repairs with parts all as pecified and as directed. |
| 53 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified and as directed. |
| 54 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation of poles/stays/cables etc and getting out in any type of soil. |
| 55 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers n.exc 25cm. |
| 56 | Removing excavated material n.exc 50m and depositing were directed at a level n.exc. 1.5m above the starting level. |
| 57 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I) |
| 58 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified |
| 59 | Supply and fixing 40 mm dia GI tubing medium grade ISI marked laid in trenches / laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified and directed. Please Enable Macros to View BoQ information |