| 1 | Dismantling floor, hearth or wall tiling or stone flooring including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 2 | Demolition of cement concrete unreinforced in ground floors and pavings not exc 15cm thickness below or above ground level etc, complete all as specified and directed. |
| 3 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone agg 40mm thick, complete all as specified and directed. |
| 4 | M&L for 600mm x 600mm x 10mm thick coloured vetrified light shade 1st quaility tiles shade as approved flooring (in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor, complete all as specified and directed. |
| 5 | M&L for 600mm x 600mm x 10mm thick coloured vetrified light shade 1st quaility tiles shade as approved (in any pattern) in vertical surfaces as skirting and jointed with neat cement slurry over fixed to wall as skirting with 10 mm thik cement sand mortar in CM 1: 4 and pointed with coloured cement matching with surfaces of tiles as in floor complete, complete all as specified and directed. |
| 6 | M&L for coloured printed non skid tiles area of each tile exceeding exc 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed with neat cement slurry pointed with colour cement to match the floor, and including 15 mm thick screed bed cement mortar in CM 1:6 and including the chipping of the existing PCC floor, complete all as specified and directed. |
| 7 | M&L for digital design glazed ceramic tiles in vertical surface of size of each tile 300 x 450 mm and 7 to 8 mm thick fixed to wall with 10 mm thik cement sand mortar in CM 1: 4, set and joint in neat cement slurry and pointed in white or coloured cement to match the same, complete all as specified and directed. |
| 8 | M&L for machine cut kota stone slab flooring 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, moulding on edge and polishing over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 9 | M&L for granite (of any type) tiles 20-22mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types and incl 20mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 10 | M&L for 75 mm thick PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection, complete all as specified and directed. |
| 11 | Taking down existing water proofing treament any nos of layers and of any description, including demolition and taking off PCC padding/plaster on RCC slab, also including removing of bitument coating to show the concrete surface to its true colour and roughening etc and also removing the debris outside the MOD land, complete all as specified and directed. |
| 12 | Taking down existing mud puska any nos of layers and of any description, including removing of the debris outside from MOD Land up to distance 250 mtr, complete all as specified and directed by Engr-in-Charge. |
| 13 | Cutting out cracks to V-Section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 including macthing existing surfaces, complete all as specified and directed. |
| 14 | M&L for cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) on roof padding having thickness of 25 mm in slope finished even and fair complete all as specified and directed. |
| 15 | M&L for 15 mm thick screed bed in cement mortar 1:4 mixed with integral water proofing compound @ 3% by weight of cement, complete all as specified and directed. Note : WPC shall be measured and paid seprately. |
| 16 | M&L for laying APP modified membarane with non woven polyester reinforcement mat (concrete core) not less than 3 mm thick & not less than 3.5 kg /sqm, the over the lap patching shall be 100 mm on length side & 100 mm on width side over a tack coat of Industrial bitumen of 1.20 kg/Sqm over Bituminious based primer IS No. 3383 @ 250 gms/sqm including apply of Aluminium colour synthetic enamel paint @ 200 gms/sqm all as per manufacture's instruction, complete all as specified and directed.Note: Supply only integral water proofing compound shall be measured and paid separately. |
| 17 | Supply only integral water proofing liquid (ISI marked) complete all as specified and directed. |
| 18 | S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed. |
| 19 | S&F for Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 20 | S&F for 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed. |
| 21 | M&L for structural steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410-W (Gde E 250 quality A), complete all as specified and directed. |
| 22 | M&L for plates (plain or chequered) channels of Fe 410-W (Gde E 250 quality A), square cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified and directed. |
| 23 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 24 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roofcoverings, complete all as specified and directed. |
| 25 | S&F for pre- painted galvalume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 26 | S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 27 | Demolition of brick work built in cement mortar of any description, complete all as specified and directed. |
| 28 | M&L for brick work with sub class 'B' Bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 as in manholes and drain, complete all as specified and directed. |
| 29 | Taking down cement plaster from brick or stone masonry or concrete surfaces and hacking for key and scrubbing down with water etc., complete all as specified and directed. |
| 30 | M&L for rendering 15mm thick on fair faces of brick work or concrete sur faces in CM 1:6 other than fair face of brick works etc or similar surfaces etc including mixing with water proofing compound @3% by weight of cement all as specified and directed by Engr-in-Charge. Note: Supply only integral water proofing compound shall be measured and paid separately. |
| 31 | M&L for 15 mm thick rendering in cm 1:6 on brick surfaces or concrete surfaces finished even and smooth without using extra cement, comlete all as specified and directed. |
| 32 | M&L for rendering 05mm thick in CM 1:3 on concrete surface in ceillings etc, complete all as specified and directed. |
| 33 | M&L for providing cement concrete 1:2:4, type B1, using 20 mm graded stone aggregates as in coping and other similar work, complete all as specified and directed. |
| 34 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 35 | M&L for RCC 1:2:4 B0 (using of 12.5 mm Stone Aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and chajjas, complete all as specified and directed. |
| 36 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200m thick (Horizontal or sloping), complete all as specified and directed. |
| 37 | M&L for 10 mm dia and over TMT bar cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends binding with MS wire n.exc 0.9mm or with securing clips etc, complete all as specified and directed. |
| 38 | M&L for preparation of new plastered surfaces and applying two coats of cement base paint on walls over a coat of alkali resistant priming paint complete all as specified and directed. |
| 39 | M&L for preparation of new wall surface and applying two coat of oil bound distemper after 3mm thick wall care putty on new plastered surfaces including necessary prepararion complete all as specified and directed. |
| 40 | M&L for preparation of new wall surface and applying three coat of white wash on new surfaces on ceiling including necessary prepararion complete all as specified and directed. |
| 41 | M&L for complete removal of existing treatment by washing, rubbing down and stopping of distempered and painting surfaces etc and applying two coats of oil bound distemper on walls over a coat of 3 mm thick wall care putty, complete all as specified and directed. |
| 42 | M&L for prepration of old surfaces of walls and applying one coat of cement base paint on surfaces of wall including washing rubbing down stopping, complete all as specified and directed. |
| 43 | M&L for preparation of old previously decorated surfaces by brooming down or steel wire brushes, scrapping down smoke soot, moulds, efflorescent salts etc and applying one coat of white wash on walls, complete all as specified and directed. |
| 44 | All as per item No 43 above but on ceiling. |
| 45 | M&L for precast cement concrete type-B1 1:2:4 by using 20 mm graded crushed broken stone aggregate, in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings set in cement mortar 1:4, complete all as specified and directed. |
| 46 | Taking down chowkats or frame n.exc. 1.50 sqm each with shutters (with out taking off shutter from the frame) and removing from the site, complete all as specified and directed. |
| 47 | All as per item 46 above but exc 1.50 sqm and n.exc 4.00 sqm each (with out taking off shutter from the frame) and removing from the site. |
| 48 | S&F in repair framed work as in doors, for door frames or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing, Fe-410-W (Gde E-420) quality, complete all as specified and directed. |
| 49 | S&F for factory made, 30 mm thick flush shutters, solid core construction with block board core and ply wood face panels commercial type on both side. Exposed edges of shutter to be provided with 6mm thick teak wood lipping. The thick ness of lipping shall be 12mm for sides on which hinges are to be provided, complete all as specified and directed. |
| 50 | S&F for ECO 2000 series Approx size of 0.90 m x 1.20 m Roll framed galvanised pre painted steel section windows/ventilators including provision of grills, 5 mm thick glass and SS wiremesh specification and drawing as per CE (AF) WAC, PALAM sheet no -1/2 and 2/2 of drawing no-CEAF/STD-191/2014 etc complete all as specified and directed by Engineer-in-Charge.(a) Fixing details:- frame and shutter frame sections should be cut to lenth and miter joined with poly propylene corner brackets, mullion section should be joined with frame/mullion using nylon mullion cap, ethyl propyllene diamene monomer (EPDM) gasket should be used all around glass in shutter and fixed glass. Rubber gasket should be used aroud the fly mesh to fix mesh in mesh shutter.(b) Accessories:- Each Glazed shutter should be provided with MS powder coated friction hinges, high grade aluminium powder coateed handle -1 for each shutter(c) Glass shutters having fixed glass shall be 5 mm thick orion blue (ET725) GLASS, having U value of 3.85 W/sqm K, light transmission factor of 18% and solar radiation factor of 0.23 fo ST Gobin, HNG OR MODIGUARD(d) Windows should be provided with grill made of 10mm SQR. MS Bars welded to at 150 mm centre to centre, 6mm x 12mm MS flat. Total grill unit should be powder coated and fixed to window frame with screws.(e) Window frame should be fixed to brick/concrete masonry by using nylons self expanding caps and driving MS electroplated 80 mm long screws into the caps through frames.(f) Mesh shutter should be provided with a stainless steel 32 gauge fly mesh of 304 grades with 144 holes per Sqr inch. |
| 51 | S&F in repair Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed. |
| 52 | S&F in repair Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing complete all as specified and directed. Note:- Door frame shall bewater proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life. |
| 53 | S&F in repair sheet glass 4.8 mm thick ordinary quality and fixed with oil putty/ wooden beads in square n.exc. 0.5 sqm in each pane, complete all as specified and directed. |
| 54 | S&F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed, complete all as specified and directed. |
| 55 | S&F for aluminium anodized barrel tower bolts of extruded section 150 mm long, complete all as specified and directed. |
| 56 | S&F in repair 300mm long aluminium alloy, anodised, sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, complete all as specified and directed. |
| 57 | S&F for butt hinges medium weight cold rolled mild steel 100 mm size, complete all as specified and directed. |
| 58 | S&F for aluminium handles cast type anodized of 150 mm size, complete all as specified and directed. |
| 59 | M&L for preparation of old decorated wooden surfaces and applying one coat of synthetic enamel paint over 10 cm in width or girth, complete all as specified and directed. |
| 60 | M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 61 | M&L for preparation of old steel surfaces and applying one coat of synthetic enamel paint on steel surface over 10 cm in width or girth, complete all as specified and directed. |
| 62 | M&L for preparation of new steel surfaces over 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide, complete all as specified and directed. |
| 63 | S&F for interlocking aluminium powder coated snap grid consists of main Tee runners of size 38mm x 25mm x 1.00 mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x1.00mm, 1200 long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Tee 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 1.5mm . Aluminium alloy extruded section shall be aluminium anodized ( minimum 15 micron) and shall conform to IS 733, IS 1285 and IS 737 and providing and fixing with hangers of 4mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long size of grid 600 x 600mm complete all as specified and directed. |
| 64 | S&F for 12mm thick perforated particle board/tiles for insula-tion and accoustic purposes, 60x60cm in size, fixed with nails to timber frame work or with staples on snap grid, complete all as specified and directed. |
| 65 | Dismantling wall and ceiling board (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets etc, complete all as specified and directed. |
| 66 | Taking up or down steel water tubing and connection incl cleaning for refixing or removal to stores for following bore :- |
| 67 | All as per item No 66 above 15mm |
| 68 | All as per item No 66 20mm |
| 69 | S&F GI tubes medium grade with all fitting and fixed concealed complete to walls and ceiling or laid in floor in following bore of tube :- |
| 70 | All as per item No 69 15mm |
| 71 | All as per item No 69 20mm |
| 72 | S&F in repair 20mm Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair and complete all as specified and directed. |
| 73 | S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position all as specified and directed as per SSR Pt- I, complete all as specified and directed. |
| 74 | S&F in repair 15 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repair and complete all as specified and directed. |
| 75 | S&F sinks in repair made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 76 | S&F in repair vetrious china wash hand basin, white flate back size 550 mm x 400 mm including cutting for and pinning in ends of barakets or erecting stand, complete all as specified and directed. |
| 77 | S&F in repair to looking mirror 600x450mm bevelled edges of selected quality glass mounted on 6mm commercial ply or AC building board with aluminium frame around and fixed to wooden plugs with CP brass screws, complete all as specified and directed. |
| 78 | S&F in repair 10 Litre PVC low level flushing cistern complete with syphonic action type, white, with inlet, ball valve, float and handle connecting to ITWC/ETWC and fixing on walls with brackets, complete all as specified and directed. |
| 79 | S&F in repairs for Vitreous China squatting pan,\\"Orissa\\" pattern,size 580 x 440 mm white,withintegral foot rests (excluding flushing cistern and flush pipe) including connection to flushing pipe anti syphonage pipe etc, complete all as specified and directed. |
| 80 | S&F in repair vitreous china wash down water closet, pedestal pattern (EWC), white, with 'P' or 'S' trap, with PVC water closet seat, black or white, closed pattern, with flat bottom and cover and mild steel chromium plated or aluminised hinging device including taking down and removal of existing old water closet with seat cover, complete all as specified and directed. |
| 81 | S&F PVC connection 15 mm bore 450 mm in length, complete all as specified and directed. |
| 82 | S&F in repair brass CP waste coupling (half or full threaded) of 32 mm size, complete all as specified and directed. |
| 83 | S&F in repair brass CP soap dish of approved quality, complete all as specified and directed. |
| 84 | S&F in repair brass CP tower rail, 600mm long of consisting three rod, brackets, complete all as specified and directed. |
| 85 | S&F in repair 15mm chromium plated swivel shower rose with or without swivel joints sny size for fixing with 15 mm pipe incl shower arm 15 mm size, 195 mm long with bend of 45 degree, complete all as specified and directed. |
| 86 | S&F 15mm bore fancy type chromoum plated bib taps, cast copper alloy with fancy type handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. |
| 87 | S&F in repairs 15 mm angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make, complete all as specified and directed. |
| 88 | S&F in repair PVC 110 mm (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps and for sewage line complete all as specified and directed. |
| 89 | S&F in repair PVC 75 mm (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps and for sewage line complete all as specified and directed. |
| 90 | S&F in repair PVC 110 mm (SWR) bends any radius, complete all as specified and directed. |
| 91 | S&F in repair PVC 75 mm (SWR) bends any radius, complete all as specified and directed. |
| 92 | S&F in repair PVC (SWR), junction single, (Single T) equal or unequal 75 mm, complete all as specified and directed. |
| 93 | Demolition of tiles/ Interlocking tiles laid dry or laid dry and pointed of any description or thickness in floors, aprons, etc, complete all as specified and directed. |
| 94 | M&L 100 mm thick PCC 1:4:8 type D-2 (using 40mm grade stone aggregate) as in Sub base of flooring etc complete all as specified and directed. |
| 95 | M&L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and coloured pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, complete all as specified and directed. |
| 96 | M&L for Sand filling under floors or in foundation including watering and consolidating complete all as specified and directed. |
| 97 | Excavation in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50m, complete all as specified and directed. |
| 98 | Material and labour for PCC 1:3:6 type C-2 in foundation filling and mass concrete and filling of footing for fencing post, complete all as specified and directed. |
| 99 | M&L round bars Fe 410W of 10 mm dia and above cut to length, bent to shape required, cindluding cranking, bending spirally for hooping and fixing as required, complete all as specified and directed. |
| 100 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5 cm but n. exc 10cm long and dia 5 to 10mm, complete all as specified & directed. |
| 101 | Supply only chain link MS galvanised fencing, of any size and type, complete all as specified and directed. |
| 102 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire, complete all as specified and directed. (Supply of chain link shall be measured separetly) |
| 103 | Dismantling of chain link fencing, wire mesh & angle, any type in fencing, complete all as specified and directed. |
| 104 | Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc complete all as specified and directed. Please Enable Macros to View BoQ information |
| 105 | Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc complete all as specified and directed. Please Enable Macros to View BoQ information |