| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. |
| 2 | All kinds of soil |
| 3 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 4 | G.S. Sheet |
| 5 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 6 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 7 | Of area 3 sq. metres and below |
| 8 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in charge. |
| 9 | Orissa pattern W.C Pan of size 580x440 mm |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 11 | 1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 13 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 14 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 15 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: |
| 16 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 19 | Foundations, footings, bases of columns, etc. for mass concrete |
| 20 | Suspended floors, roofs, landings, balconies and access platform |
| 21 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 22 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 23 | 12 mm cement plaster of mix: |
| 24 | 1:4(1 cement: 4 fine sand) |
| 25 | 12 mm cement plaster finished with a floating coat of neat cement of mix: |
| 26 | 1:4(1 cement: 4 fine sand) |
| 27 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 28 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 29 | Ridges plain (500- 600mm) |
| 30 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 31 | Electric resistance or induction butt welded tubes |
| 32 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 33 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 34 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 35 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 36 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 37 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 38 | 300x16 mm |
| 39 | 250x16 mm |
| 40 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 41 | 250x10 mm |
| 42 | 150x10 mm |
| 43 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 44 | 125 mm |
| 45 | 100 mm |
| 46 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 47 | Frame size 65 x 100 mm |
| 48 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 49 | 30 mm thick |
| 50 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 51 | 100X58X1.90 mm |
| 52 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 53 | Two or more coats on new work |
| 54 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 55 | One or more coats on old work |
| 56 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 57 | For thickness of tiles 10 mm to 25 mm |
| 58 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 59 | Providing and fixing Pre -laminated medium density fibre board exterior grade (Grade-I) IS:14587:1998 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately). |
| 60 | Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 18 mm thick conforming to IS:14587 |
| 61 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 62 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 63 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour |
| 64 | Old work (one or more coats) |
| 65 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 66 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 67 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 68 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 69 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 70 | Semi rigid pipe (32 mm dia) |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 72 | 20 mm nominal dia Pipes |
| 73 | 25 mm nominal dia Pipes |
| 74 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 75 | 15 mm nominal bore |
| 76 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 77 | 15 mm nominal bore |
| 78 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 79 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 80 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 81 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 82 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 83 | Providing and laying United Polyethylene Saptic Tank made of polyethylene in a single moulding with 3 chamber and 2 manholes, the high wall/ thickness of septic tank should with stand load and pressure of the earth to a great extent. |
| 84 | Type- I 750 mm X 2500 mm, 10-15 Flushing per day. |
| 85 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked stainless steel butt hinges bright finished of required size with necessary screws. |
| 86 | Superior hard wood cat- II A |
| 87 | Providing and fixing CPVC Union in CPVC Pipe including cutting and joining the pipe etc. complete( New work). |
| 88 | 20mm nominal bore |
| 89 | 25mm nominal bore |
| 90 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 91 | Group -A |
| 92 | Wiring for Circuit / Sub Main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required. |
| 93 | a) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 94 | b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 95 | c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 96 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 97 | a) 5/6 A Switch |
| 98 | b) 3 pin 5/6 A Socket Outlet |
| 99 | c) 15/16 A Switch |
| 100 | d) 6 pin 15/16 A socket outlet |
| 101 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 102 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 103 | a) 3 Module (100mmX75mm) |
| 104 | b) 6 Module (200mmX75mm) |
| 105 | Supplying and fixing 3 pin, 5 amps ceiling rose on the existing junction box / wooden block including connection etc as required. |
| 106 | Installation testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. |
| 107 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required |
| 108 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required |
| 109 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 110 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 111 | a) 6 way , Double door |
| 112 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 113 | a) Single Pole |
| 114 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 115 | a) 40 Amps |
| 116 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required |
| 117 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required |
| 118 | Supplying of LED 20 Watts Batten/Tubelight Streak square 4-ft cool day light similar to Wipro Garnet 20 W LED 6500 K or its equivalent. |
| 119 | Supplying of integrated LED bulk head luminaire, Murphy 10W Oval Shape IP54 Water proof cool white or equvilant. |
| 120 | Supplying installation, testing and commissioning of ASHLOK make SEE brand safe earthing electro type-19, 50mm dia length 2 mtrs and inner space to be filled with crystaline conductive mixture including filling up with elelctrodite (Back fill compound ) as reqd for safe earth electrode and providing masonary enclusure with cover plate having locling arrangement etc as reqd. |
| 121 | Supplying of Energy Saving 5 star rating, with ISI, A.C. Ceiling fan 1200 mm sweep, with all accessories . (Similar to Plycab Eteri Energy Efficient BLDC 5 Star) or equivalent |
| 122 | Supply of LED bulb of 9 Watts of Panasonic or equivalent to ISI specification. Please Enable Macros to View BoQ information |