Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Good earth for filling (3 km) |
| 2 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation |
| 3 | Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers) |
| 4 | Cement concrete 1:8:16 with 40 mm gauge stone ballast. using concrete mixing volumetric type |
| 5 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 6 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 7 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 8 | Reinforced cement concrete M-25 mechanically batchmixed using batch type concretemixer asper IS:1791andvibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 9 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc |
| 10 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 11 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete |
| 12 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 13 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 14 | Providing and Fixing in position collapsible steel shutters, with vertical channels 20mmx 10mmx2mm and braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T iron 40mmx40mmx6mm with 38mm dia steel pulleys, complete with bolts, nuts, locking arrangements, stoppers, handles, etc. complete in all respects. |
| 15 | 12.5 mm thick cement plaster 1:4 |
| 16 | 16mm thick cement plaster 1:4 in two coat work |
| 17 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 18 | Supplying and fixing of Japani sheet frames(Chowkat) consisting of 18 gauge (1.25 mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges onforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.Double Rebate 151x60x35 |
| 19 | Single Rebate door |
| 20 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) |
| 21 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respectGlazing area above 0.09 sqm |
| 22 | Factory manufactured solid flush door fixed in position iron hinges, etc . (excluding the cost of any fittings other than specified above but including the labour for fxing the same in position a) comercial with elm or gujan facing on both/sides with laminated core and lipped edges. iv) 35mm thick. |
| 23 | Providing and fixing high pressure laminated sheet 1 mm thick. |
| 24 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 25 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 26 | Providing Polyester Powder coating 50 micron any coloured specified to alumnus section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 27 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm) |
| 28 | Providing and fixing 12mm thick prelaminated particle board flat pressedthree layer or graded wood particle board conforming to IS: 12823 Grade l Type all, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminatedparticle board with decorative lamination on one side |
| 29 | Providing and fixing glazing in aluminum door, window, ventilator shutters andpartitions etc. with PVC Plug/ neoprene gasket etc. complete as per thearchitectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) |
| 30 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminum doors including necessary cutting and making good etc. complete. |
| 31 | Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 32 | Providing & fixing 6mm thick BISON board waterproof panelling on wall with the help of PVC Gatti & SS Screws up to 3'-6\\" high on periphery wall of inside hall complete as per drawing & desired by Engineer-in-Charge |
| 33 | Providing and fixing beading to door and windows chowkis of commercial hard wood, such as Hollock, Champ, Chrissy Chap lash etc (Non coniferous timber other than teak conforming to ISI specification no 100., kiln seasoned) with iron screws, fixed in position complete as per design and shape required 50mmx12mm |
| 34 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 35 | Providing & applying heritage granual homogeneous wall finishing system fromBakelite Coating & Paints Pvt. Consisting of two component system of dry Granual (25 kg/pack) made of 92% silice particle, coated with fade resistant pigmants and 100% acrylic co-polymers bonding agent (5 ltr pack) with the applied thickness of coating being between 0.8 to 1.2mm to be applied in single coat on a cured level smooth plastered, as per the shade combination approved and as per manufacturer specification, all complete inclusive of primer on the base. |
| 36 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shad |
| 37 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 38 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. Including priming coat & preparation of surface |
| 39 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 40 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 41 | Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm. |
| 42 | Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading. |
| 43 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). |
| 44 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) |
| 45 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Non traffic Areas and streets having width less than 3.05 mt.( Also not to used over footoaths). |
| 46 | Providing and fixing of Back Panel of Reception comprising of framing of 50mm x 50mm Partal/ Kail wood or equivalent with 3mm thick backing of Bakelite sheet on wall side,6mm thick waterproof ply on both sides and front portion fixed with 1mm thick laminate of colour and shade to be approved by Architect.Grooves in laminate or elsewhere to be provided as per architectural drawing. The make of ply and laminate and colour of laminate shall be provided as per approval by Architect/ Engineer-in-charge |
| 47 | Civil work on making brick pillers and for front design (Note :- But to be paid on actual basis after the certification of field officer) |
| 48 | Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 49 | Providing Signage & Providing New Colour ACP Sheet after Removing of existing ACP Sheets |
| 50 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge.3mm thick ACP Sheet |
| 51 | Writing matter on front signage Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012 |
| 52 | Providing and Fixing Name Plates of various sizes made of PVC sheet printed with self adhesive tape pasted on sunboard complete as desired by Engineer-in-Charge |
| 53 | Providing and Fixing Letters of “MOHALLA CLINIC” in SS 304 grade. Height and font as per approved drawing |
| 54 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 55 | Providing and fixing in position gratings 150mm x 150mm on top Khura PVC grating |
| 56 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top ofR.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 57 | Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 58 | Renewing glass panes with putty and nails wherever necessary Glass panes weighing 10.75 Kg/sqm |
| 59 | Providing and fixing at site the Reception Table plan dimensions as 5’-6” x 4’6” and height 2’-3” with storage, drawers, space for legs, etc complete as per drawing. The table should be sturdy and stable and will comprise of knot-free teak wood, wherever required, 19mm/ 12mm/ 6mm water proof ply and 1mm laminates of Make and Colour to be approvedby Architect/ Engineer-in-charge. The item also includes hardware such as drawer channels, handles, etc of make and design to be approved by Architect/ Engineer-in-charge. The item also includes all types of consumables such as nails, screws, fevicol, tape, etc and polishing, if required.Grooves, wherever required as per drawing, are also included in the item.complete as per drawing/design as desired by Engineer-in-Charge. |
| 60 | Providing and fixing at site the Pharmacy Counter plan dimensions as 5’-3” x 1’-101/2” and height 2’-6” with projected shelve, storage, drawers, space for legs, etc complete as per drawing. The Counter should be sturdy and stable and will comprise of knot-free teak wood, wherever required, 19mm/ 12mm/ 6mm water proof ply and 1mm laminates of Make and Colour to be approvedby Architect/ Engineer-in-charge. The item also includes hardware such as drawer channels, handles, etc of make and design to be approved by Architect/ Engineer-in-charge. The item also includes all types of consumables such as nails, screws, fevicol, tape, etc and polishing, if required.Grooves, wherever required as per drawing, are also included in the item.complete as per drawing/design as desired by Engineer-in-Charge. |
| 61 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. |
| 62 | Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge. |
| 63 | Providing Internal Electrical Installations: |
| 64 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 65 | Wiring fan point (without fan box ) |
| 66 | Wiring light point |
| 67 | Wiring call-bell point |
| 68 | Wiring 6 Amp. wall socket point |
| 69 | Wiring 6 Amp. Plug control comprising wall socket point |
| 70 | Wiring 16/20 amp. power plug control point |
| 71 | REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01:Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01) |
| 72 | Wiring light point |
| 73 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 74 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 75 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 76 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 77 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 78 | Wiring Telephone socket point RJ11 (one module) |
| 79 | Wiring Networking socket point RJ45 (one module) |
| 80 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 81 | Ceiling Rose (Flush Piano type) |
| 82 | Call Bell 220/230 volts AC Ding Dong |
| 83 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 84 | Overall size 1.5sq.mm (Un-sheathed) |
| 85 | Overall size 2.5sq.mm (Un-sheathed) |
| 86 | Overall size 4sq.mm (Un-sheathed) |
| 87 | Overall size 10sq.mm (Un-sheathed) |
| 88 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 89 | Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed |
| 90 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 91 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 92 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 93 | PVC flexible pipe 40mm dia. |
| 94 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 95 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 96 | Copper Earthing |
| 97 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 98 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 99 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 100 | MCB'S & MCB DISTRIBUTION BOARDS: |
| 101 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 102 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 103 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 104 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 105 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 106 | SP&N Double Door Distribution Board 12 way each |
| 107 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 108 | LT CABLES |
| 109 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 110 | Overall size 16sq.mm (4 Core) Un-armoured (Loose) For PSPCL supply |
| 111 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 112 | Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
| 113 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 114 | MCCB Four Pole 40/63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 115 | MS SHEET ENCLOSURE FOR MCCB's:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 116 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 117 | SHEET METAL IRON CLAD CHANGEOVER SWITCHES:Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:- |
| 118 | IC Four Pole Changeover Switch 63amp., 415volts |
| 119 | AUTOMACTIC VOLTAGE STABLIZER:-Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- |
| 120 | Automatic Voltage Stablizer 4 KVA |
| 121 | Automatic Voltage Stablizer 5 KVA |
| 122 | LED'S FIXTURES & FANS: |
| 123 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 124 | Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser and efficacy of LED fixture minimum 100 lumens per watt complete in all respects as approved and desired by the Engineer in-charge at site. The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 125 | Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 126 | Supply and erection of LED Street Light 45 watt (including LED driver) with pressure die cast aluminium housing with control gear ( IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021 |
| 127 | Supply and erection of Ceiling Fan 1200mm (48\\") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. The fan should conform to Technical Specifications attached. |
| 128 | Supply and erection of Ventile Air Fan 225/230mm with aluminium louver shutter longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. The fan should conform to Technical Specifications attached. |
| 129 | SITC of Wall Fan Size 400MM as desired by EIC. The fan should conform to Technical Specifications attached. |
| 130 | Supply & Installation of 12V. 150AH tubular battery including connection & testing charges etc. Complete in all respect as per entire satisfaction of the Engineer In Charge. |
| 131 | Supply & Installation of Stand for Inverter & 2 No. Batteries including connection & testing charges etc. Complete in all respect as per entire satisfaction of the Engineer In Charge. |
| 132 | Supply & Installation of 2KVA Microtek Sinewave Inverter including connection & testing charges etc. Complete in all respect as per entire satisfaction of the Engineer In Charge. |
| 133 | Providing 2Way Phone, Patient Token System,Local Area Networking : |
| 134 | Supply Installation Testing and Commissioning of 10 port 10/100 PoE switch, 8*10/100 PoE port + 2 10/100 uplink, power budget 120W, IEEE 802.3af/at extended range 250 mtr complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 135 | Supply, installation, testing & commissioning of Category 6 UTP , 4 Pair This cable well exceeds the requirements of TIA/EIA-568-C.2 and IEC/ISO 11801. Construction: 4 twisted pairs separated by cross separator, 4 channel, polymer spine / full separator. Half shall not be accepted. Cable should be Armoured. Operates at bandwidth of 250 MHz, Conductor Solid Bare Electronic Grade Copper. Inner jacket should be PVC and outer should be PE, suitable for direct burial. Insulation: Polyethylene, Attenuation (< 36 db/100m), Pair – to – pair and PS NEXT, ELFEXT and PSELFEXT, Return Loss, ACR and PS ACR., Nominal Outer Diameter of Cable should be 9.70 mm and Conductor Diameter 0.56 mm (23 AWG), Cable should support operating Temperature from -20° to +60°C, Cable should come with printed sequential Length Counter on each meter, Cable support Conductor Resistance 93.5 OHMS/1000MTR@20 Degree, Mutual Capacitance of cable should be < 5.6nF/100m, Max Resistance Unbalance of cable should be 5% Max, Capacitance Unbalance of cable should max 330pF/100m, Cable support Delay Skew: < 45nS, Operating Voltage: 72V and NVP: 69%, Shall Supports Gigabit Ethernet (1000 base-T) standard and Operates at bandwidth of 250MHz complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 136 | Supply, installation, testing & commissioning of 1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 24v, Efficiency : Above 90%. .complete in all respects as approved and desired by the Engineer-in-charge at site |
| 137 | S/I/T/C of intercom facility 1+1 Basic Plan Phone Ringer volume control switch Tone/ Pulse Switchable Redial Mute Flash Pause Intercom facility Call T, Holding the line / Music on Hold during call transfer Line use LED Indication, Secrecy during conversation between both phones, including connecting cables |
| 138 | S/I/T/C of Token Calling Display System having screen size 4 inches, Voice calling/ Bell System, complete key pad Etc, calling display up to 60 meter cable (5 meter length included), serial communication design, Text Color Red Display Shape Rectangle,Power 5 W,Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital,Cash counter etc, Warranty 1 Year,220 VAC Operating Voltage Character Capacity 3 Character, Power Consumption |
| 139 | Supply and erection of Wall Mounted 6U Rack with power point and fan. |
| 140 | Providing Double Door Refrigerator,Water Dispenser and Split air conditioner: |
| 141 | Supply,Installation and Comissioning of Frost Free Double Door Refrigerator capacity 250 Ltr - 265 Ltr complete in all respect. The Refrigerator shoud also conform to technical specifications attached herewith. |
| 142 | Supply Instalation Testing and commisssioning of floor mounted Hot, cold and normal water 3 Tap dispenser. Complete in all respect as required.The Water Dispenser should also conform to the technical Specication Attached herewith |
| 143 | Supply, Installation and Comissioning of BEE 3 STAR/4STAR 2.0 Ton split air conditioner with 100% coper coil material( evaporator and condensor) complete in all respect . The Air Conditioner should also conform to the technical Specication Attached herewith |
| 144 | Supply, Installation and Comissioning of BEE 3 STAR 1.5 Ton split air conditioner with 100% coper coil material (evaporator and condensor) complete in all respect . The Air Conditioner should also conform to the technical Specication Attached herewith |
| 145 | SITC water RO aquafresh 15l capacity complete in all respect |
| 146 | SITC hot water instant gyser capacity complete in all respect |
| 147 | Sub Work-1 Internal Water Supply, Sewerage, Sanitation |
| 148 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type A |
| 149 | 110mm o/d single socket SWR UPVC pipe lines laid complete |
| 150 | 75mm o/d single socket SWR UPVC pipe lines laid complete |
| 151 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 152 | For 110mm i/d pipes |
| 153 | Elbow 90 Degree (All side socketed) |
| 154 | Coupler |
| 155 | Single Tee With Door |
| 156 | For 75mm i/d pipes |
| 157 | Coupler |
| 158 | Floor Trap 110mm x 75mm |
| 159 | With 75mm i/d outlet deep seal at Ground Floor |
| 160 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. |
| 161 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 162 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weightas per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 163 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 164 | Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. |
| 165 | uPVC Pipe 6 Kgf/cm250mm i/d |
| 166 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 167 | CPVC SDR 11 Pipe & fitting 16mm o/d |
| 168 | SDR 11 CPVC pipes & fittings 20mm o/d |
| 169 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 170 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm |
| 171 | qty same as GI P 15mm i/d to 25 mm |
| 172 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 173 | Through wall 22.86 cm thick |
| 174 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. |
| 175 | 15mm i/d G.I. Union |
| 176 | 20mm i/d G.I. Union |
| 177 | 25mm i/d G.I. Union |
| 178 | Painting G.I. Pipes and Specials with synthetic enamel Paint in all shades as per I.S.I. specification on existing or new work, two coats paints including cleaning rubbing surface, etc. |
| 179 | 15mm & 20mm i/d G.I. Pipe |
| 180 | 25mm & 32mm i/d G.I. Pipe |
| 181 | Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware extended wall mounted E W.C. with matching chinaware cistern and seat cover complete in all respect. Detail attached as per Table-3 |
| 182 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.With PTMT nut |
| 183 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 184 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tubeconnection 300 mm long complete. |
| 185 | Qty. as per Detail in Table-3 |
| 186 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. |
| 187 | Size 550 mm x 400 mm x 815mm |
| 188 | Providing and fixing in position vitreous Chinaware white laboratory sinks of approved make (to the approval of Engineer-in-charge) consisting of a pair of brackets, C.P. brass waste 40mm complete in all respect. |
| 189 | Size 470mmx370mmx180mm |
| 190 | Providing & fixing 15 mm C.P brass laboratory cock swan neck of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 191 | Laboratory cock swan neck One Way |
| 192 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut |
| 193 | Qty same as OWC+EWC+WB+Urinal+Steel sink |
| 194 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 195 | Qty same as WB+Urinal+Steel sink+Lab Sink + Drinking water (-) Bottle trap |
| 196 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 197 | C.P brass towel ring |
| 198 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 199 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 200 | C.P. brass Bib cock long nose/ long body without flange |
| 201 | C.P Brass bib cock foam flow without flange |
| 202 | Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in-charge) complete in all respect (instead of Pillar tap in Lavatory Suites). |
| 203 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 204 | C.P.brass 15mm Angle valve without flange |
| 205 | C.P.brass 15mm Concealed stop cock with flange |
| 206 | For Jet Spray Connection + Over Head Shower |
| 207 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 208 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long |
| 209 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) |
| 210 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. Brass Accessories: |
| 211 | C.P. brass toilet roll holder with flap |
| 212 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.Aluminium khunti with 3 pegs |
| 213 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks |
| 214 | 1000 ltr Capacity |
| 215 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball |
| 216 | Brass Ball Cock with rod and Plastic Ball 32mm i/d |
| 217 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 218 | G.I. tank nipple 25mm i/d Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail