| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (Not exceeding 1.5 mtr in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, depth upto 1.5mtr. including disposal of excavated earth upto 25 mtr from cutting edge, disposed earth is to be levelled and neatly dressed in: All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering , all works upto plinth level ( 1 : 4 : 8)1 cement 4 coasre sand 8 stone aggregate grade , with 40mm nominal size . crushed |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering , all works upto plinth level ( 1 : 3 : 6 ) cement 3 coasre sand 6 stone aggregate grade , with 20mm nominal size . crushed |
| 4 | Providing and laying in position reinforeced cement concrete of specified grade excluding the cost of centering and shuttering , all works upto plinth level ( 1 : 1.5 : 3)1 cement 1.5 coasre sand 3 stone aggregate grade , with 20mm nominal size . crushed |
| 5 | Reinforced cement concrete work in wall (any thickness) including attached pilasters 'buttresses'plinth and string courses'fillet ,column pillar'piers ,abutment 'post and sturts etc upto floor five level excluding the cost of centering and shuttering ,finishing and reinforement ( 1 : 1.5 : 3 )1 cement 1.5 coasre sand 3 stone aggregate grade , with 20mm nominal size . crushed |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 7 | Reinforcement of RCC work in plinth band incl straightening, cutting, bending , placing in position and binding incl.all carriages complete. |
| 8 | Brick work with common burnt clay F.P.S (Non-modular) brick of class designation 75 in foundation and plinth in 1:6 (1 cement : 6 coarse sand) |
| 9 | Extra for brick work in Super structure above plinth level upto floor V level (By manual means) |
| 10 | Centering and shittering including strutting propping etc and removal of form work Foundation footing bases of columns etc |
| 11 | Centering and shuttering incl. struting, proping ,etc.and removal of form work for;columns,pillars,piers,abutments,posts and struts RCC Column |
| 12 | Centering and shuttering incl. struting, proping ,etc.and removal of form work for edges of slab under 20 cm |
| 13 | Centering and shuttering incl. struting, proping ,etc.and removal of form work for suspended floors,roofing ,landings,balconies and access platform |
| 14 | Centering and shuttering incl. struting, proping ,etc.and removal of form work for; lintel beam ,plinth beam ,girders,bressumers and cantilevers |
| 15 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 ( 1 cement 6fine sand ) |
| 16 | 12 mm cement plaster 0n wall of mix 1:6 ( 1 cement 6 fine sand ) |
| 17 | 6mm thick plaster of mix 1:4 |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and ixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash asteners shall be paid for separately):2nd class deodar wood |
| 19 | Providing and fixing glazed shutters for doors and windows and clestory windows using 10 kg /sqm (4mm thick) float glass panes including ISI marked black enameled M.S. butt hinges bright finished of requried size with necessary screws, ( 35mm thick of 2nd class deodar wood). |
| 20 | Providing and fixing 35 mm thick wire gauze shutters using galvanised M.S. wire gauze of average width for aperture 1.4 mm in both directoin with wire of dia. 0.63 mm for doors, windows and clerestory windows with hinges and necessary screws : Second class deodar wood. |
| 21 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including lSI marked M.S. pressed Butt hinges bright finished of required size with necessary screws excluding panelling which will be paid for separately,al! complete as per direction of engineer- in charge. Second class deodar wood |
| 22 | Providing and fixing panelling or panelling and glazing in panelled or panelledand glazed shutters for doors, windows and clerestory windows (Area ofopening for panel inserts excluding portion inside grooves or rebates to bemeasured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked |
| 23 | Providing & laying vitreified floor tiles in different size ( thichness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS 15622 of approved make in all colours and shades laid on 20 mm thick cement mortar 1:4 ( 1cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. ( size of tile 60 x 60 cm) |
| 24 | Applying priming coat with ready mixed pink or grey primer including acrylic putty of approved brand and manufactures on wood work (hard and soft wood) |
| 25 | Painting of doors and windows with ready mixed synthetic enamel paint of approved brand and manufacturers in all shades (two or more coats) on new work |
| 26 | whitewashing with limeto givean even shade on new work (three or more coats ) |
| 27 | Finishing walls with water proofing cement paint of requried shade New work(one or more coat )applied @2.20.kg/10 sqm over priming coat of primer applied @0.80 litres/10 sqm complete including cost of priming coat |
| 28 | Making plinth protection 50mm thick with cement concrete ( 1 : 3 : 6) 1 cement : 3 Coarse sand: 6 stone aggregate) 20 mm nominal size of stone aggregate over 75 mm bed of dry brick ballast , 40 mm nominal size of well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 29 | Filling available excavated earth(excluding rock) in trenches ,plinth,sudes of foundation etc.Layers not exceeding 20 cm in depth,conslidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 30 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm |
| 31 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100x10 mm |
| 32 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 100x10 mm |
| 33 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering , all works upto plinth level ( 1 : 2 : 4)1 cement 2 coasre sand 4 stone aggregate grade , with 20mm nominal size . crushed |
| 34 | Providing and fixing Ms grill of reqd. patter in frame of window etc with M S flat ,square or round bars ,railing;pipe etc all complete fixed to opening/window frame with raw plugs,screw etc |
| 35 | Providing and laying Cement Concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded brick aggregate 40 mm nominal size) in retaining wall/return wall, col-umns etc. excluding cost of centering and shuttering , all work upto floor V level |
| 36 | Providing and fixing rectified Floor tiles 300x300 mm non skidtile (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 13755 of NITC.O, ORIENT, SOMANY, KAJARIA or equivalent make in colour such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick bed of Cement Mortar 1: 4 ( 1 cement : 4 coa.rse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 37 | providing and applying painting or other on surface of walls and ceilings making drawings, shades, letters, shapes as directed by site in charge |
| 38 | Demolishing brick work manually / By Mechanical means incl. stacking of serviceable material and disposal of unserviceable Material with in 50 mtr. Lead (in cement mortar). |
| 39 | Carriage of Sand by mechanical transport including loading , unloading & stacking complete lead upto 97 km and manual labour lead upto 500 mt |
| 40 | Carriage of stone aggregate below 40 mm nominal size by mechanical transport including loading, unloading & stacking complete lead upto 50 km and manual labour lead upto 500 mt |
| 41 | Carriage of bricks by mechanical transport including loading, unloading & stacking complete lead upto 115 km and manual labour lead upto 500 mt |
| 42 | providing and fixing glass panes , with wooden fillet wherever necessary Float glass panes of thickness 5 mm. |
| 43 | Providing ane fixing of white board in class room (size 4'0'' x6'0'' ) |
| 44 | Providing design from approved cosultant duly vetted by competent authority from DIQC/IIT./NIT OR any other recognised university and the work completed with in the tender amount |
| 45 | Electric Part Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A. |
| 46 | Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS/HFFR PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required. |
| 47 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 2.5 sq. mm +1x2.5 sq. mm earth wire |
| 48 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required 1 X 1.50 sq.mm |
| 49 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 50 | 5/6 A Switch |
| 51 | 3 pin 5/6 A socket outlet |
| 52 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required. |
| 53 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required. |
| 54 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. ( For light Plugs to be used in non residential buildings). |
| 55 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 12 way , Double door |
| 56 | Providing & Fixing of 240/415 VAC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked 15 8828(1996)/conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm.10:00 conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10.000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge |
| 57 | single pole 6/10/16/32 Amp. |
| 58 | SPN 63 Amp. |
| 59 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast/ Extruded aluminium Body(Thickness≥1.20mm) |
| 60 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 61 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. |
| 62 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum). |
| 63 | Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 25 sq. mm 2 core. Please Enable Macros to View BoQ information |