| 1 | Wiring for light point /fan point/exhaust fan/call bell point with 1.5sq. Mm. PVC insulated heat resident flam redardant (HRFR)and low smoke single core flexible copper conductor cable in PVC Casing & Caping and earthing the light point with 1.5sq mm. HRLRFRLS / PVC insulated single core cooper condutor cable as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge |
| 2 | Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. |
| 3 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. |
| 4 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. |
| 5 | 2x1.5 Sq. mm. |
| 6 | 2x6 Sq. mm. |
| 7 | 2x10 Sq. mm. |
| 8 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 9 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 10 | Installation of ventilatinmg/exhaust fan in the existing opening, including making good BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor the damage, connection, testing, commissioning etc. as required Supply & Erection of Ventilating Fan) following size complete with motor,, with minimum power consumption, rigid frame with rubber mounting for silent operation, in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc as required to complete the job to the entire satisfaction of EIC complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 11 | Exhaust Fan, Light duty, (Domestic) 225/230 mm sweep |
| 12 | Providing and installation of following type of LED Batten with polycarbonate housing anti glare polycarbonate diffuser,surge protection 2.5 KV luminaire efficacy > 100lm/Watt with minimum 25000 burning hours, THD<15% in white finish and seprated energy efficient constant current, non-integral, electronic driver; relevent LM 79/80 complaince fromUN/NABL Lab suitable for input voltage: AC 140-270 V, 50/60Hz, complete with all accessories, connections, testing etc as required: of Approved Make complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 13 | LED Batten Light 20W |
| 14 | LED Batten Light 10W |
| 15 | Providing and installation of following type of Surface mounting square type LED Downlight with polycarbonate housing anti glare polycarbonate diffuser, surge protection 2.5 KV luminaire efficacy > 85lm/Watt with minimum 25000 burning hours. THD<15% in white finish and seprated energy efficient constant current, non-integral, electronic driver, relevent LM 79/80 complaince from UN/NABL Lab suitable for input voltage: AC 140-270 V, 50/60Hz, complete with all accessories, connections, testing etc as required of Approved Make complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 16 | Square /Round LED Down Light 6W Surface |
| 17 | Square /Round LED Down Light 18W Surface |
| 18 | Square /Round LED Down Light 24W Surface |
| 19 | Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 20 | single pole .(Category-A) |
| 21 | Supplying and fixing following rating, followings poles 10ka 240/415v 'C' curves miniature circuit braker suitable for inductive load of following poles in the exsisting MCB DB complete with connections, testing and commissioning etc. as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 22 | 40 A DP |
| 23 | 63 A DP |
| 24 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface/ recess complete with tinned copper bus bar neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc las required (But without MCB/RCCB/Isolator) complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 25 | Double door-6 way |
| 26 | Double door-12 way |
| 27 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 28 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 29 | Providing and installation of following type of pole/Wall mounting LED luminaire with pressure die ast housing with epoxy power coated dark graphite gray colour finish. Prismatic polycaronate cover with individual LED lenses and seprated energy efficient constant current, non-integral, electronic driver, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required & approved by Engineer-in-Charge. |
| 30 | LED Street Light 45 Watt |
| 31 | Supplying and erection of street light bracket made of G.I. pipe 'A' class of suitable length and dia, the pipe bended to give an 16 angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete in all respects as required:- |
| 32 | 32 mm dia. G.I. pipe, heavy class |
| 33 | Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes with 8 bar pressure rating Five star BEE rating and safety valve installation by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:- |
| 34 | 25 Liter capacity water heater (Cat-A) |
| 35 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and 18 fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required (For light plugs to be used in non residential buildings). |
| 36 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. |
| 37 | Supplying and fixing Bed side bracket complete as required complete within all leads & lifts and to the entire satisfaction to the Engineer-in-Charge. Please Enable Macros to View BoQ information |