| 1 | Civil works |
| 2 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 meters complete in all respects & to entire satisfction of Engineer-in-Charge |
| 3 | Providing & laying Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type complete in all respects & to entire satisfction of Engineer-in-Charge |
| 4 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth complete in all respects & to entire satisfction of Engineer-in-Charge |
| 5 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded complete in all respects & to entire satisfction of Engineer-in-Charge |
| 6 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level complete in all respects & to entire satisfction of Engineer-in-Charge |
| 7 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 8 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 9 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 10 | Scraping Cement plaster |
| 11 | 20mm thick cement plaster 1:4 in two coat work |
| 12 | 12.5mm thick cement plaster 1:5 |
| 13 | Dismantling glazed tiles (to be carefully removed). |
| 14 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 15 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm. |
| 16 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) |
| 17 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing without cost of bitumen |
| 18 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded).. |
| 19 | Cost of new tile be replaced instead of broken tiles in regarding of tile terracing including loding /unloding and all leads as desired by engg. in charge |
| 20 | Credit of Brick Bats |
| 21 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps.U-PVC pipes 110 mm dia. |
| 23 | Providing and fixing 110 mm dia. SWR U.P.V.C Coupling/Sockets for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 24 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50 thick cement concrete 1:8:16 |
| 25 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge.IS Code : 15658 (2006) |
| 26 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.Doors of area 3 sqm and below. |
| 27 | Credit of old doors |
| 28 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.Windows of area 3 sqm and below |
| 29 | Credit of old windows |
| 30 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Double Rebateain Door |
| 31 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Single Rebateain Door |
| 32 | Hollock wood doors shutter windows shutter including hinges, screws, chocks,cheats, stops cords etc. complete fixed in position.panelled, glazed or glazed and panelled.35 mm thick |
| 33 | Wire gauge Hollock wood door shutter without springs housed in chowkhat.35 mm thick |
| 34 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 (a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-(iv) 35mm thick |
| 35 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 36 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. III (size of door 851mm to 1000mm) |
| 37 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area |
| 38 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 39 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 40 | Preparation of plywood surface for painting including sand papering the surface andapplying filling with approved quality fillers consisting of white lead, linseed oil, Varnish,and Chalk Mitti including finishing the surface to required finish complete. |
| 41 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade & applying priming coat with metal primer on new steel or iron work including preparation of surface |
| 42 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 43 | Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 44 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 45 | Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge. |
| 46 | Providing and fixing name plates of various size made of PVC Sheet printed with self adhesive tape pasted on sunboard complete as desired by engineer-in-charge |
| 47 | Providing and Fixing aam aadmi clinic board made with ACP sheet and lettering with Acrylic sheet complete in all respect. |
| 48 | PUBLIC HEALTH SERVICES |
| 49 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 50 | Single Socket Type B |
| 51 | 110mm o/d SWR UPVC pipe lines laid complete |
| 52 | 90mm o/d SWR UPVC pipe lines laid complete |
| 53 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonage pipes as per as per IS - 14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 54 | For 110 mm o/d pipes |
| 55 | Elbow 90 Degree (All side socketed) |
| 56 | Vent Cowls |
| 57 | Coupler |
| 58 | Single Tee With Door Changed) |
| 59 | Floor Trap 110mm x 110mm |
| 60 | With 90mm i/d outlet deep seal at Ground Floor |
| 61 | With 90mm i/d outlet Shallow seal at First Floor |
| 62 | For 90 mm o/d pipes |
| 63 | Elbow 90 degree (all side socket) |
| 64 | Vent Cowls |
| 65 | Coupler |
| 66 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) |
| 67 | 110mm o/d |
| 68 | 90mm o/d |
| 69 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. |
| 70 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 71 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 72 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 73 | CONCEALED IN WALL: Providing andfixing Chlorinated Polyvinyl Chloride(CPVC) pipes as per IS 15778 (ISI markedwith the prior approval of Engineer-in-Charge), having thermal stability for hot &cold water supply, including all CPVCplain & brass threaded fittings i/c fixingthe pipe with clamps at 1.00 m spacingincluding jointing of pipes & fittings, withone step CPVC solvent cement and testingof pipes complete as per direction ofEngineer-in-Charge. |
| 74 | CPVC SDR 11 Pipe & fitting 16mm o/d |
| 75 | SDR 11 CPVC pipes & fittings 20mm o/d |
| 76 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 77 | CPVC SDR 11 Pipe & fitting 50mm o/d |
| 78 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 79 | Size 75 mm x 75 mm |
| 80 | Cutting holes upto 23cm square through B.B.in cement walls or stone masonary wall incement for pipes, and making good the same& finishing according to existing finish whererequired. |
| 81 | Through wall 11.43 cm thick |
| 82 | Through wall 22.86 cm thick |
| 83 | Dismantling Sanitary fixtures such asEurpoean/Indian/Orissa W.C., PVC / China warecistern, Wash Hand Basin, Urinal Pot, Sinks andCP Fittings and disposal of dismantled materialwithin a distance of 100 Mtr. complete in allrespect as required by Engineer-in-Charge. |
| 84 | Providing fixing and joining CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats on CPVC Pipe lines including all carriages complete. 25 mm id brass ball valves |
| 85 | 50 mm id brass ball valves |
| 86 | Eurpoean/Indian/Orissa W.C., |
| 87 | PVC / China Ware Cistern |
| 88 | Wash Hand Basin / Urinal Pot |
| 89 | Bathroom Assessories such as Soap Dish,Towel Rail, Towel Ring, Towel Bracket,Mirror, Toilet Paper Holder, Seat Cover, JetPressure and all other accessories. |
| 90 | CP Bib Cock/Angle Cock/Stop Cock/Shower/Bottle Trap |
| 91 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 92 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. With C.P. Brass nut |
| 93 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 94 | Providing and fixing in position vitreousChinaware white lIndian make large flat backor angular lipped front urinal 375 x 390 x 590mm of approved make (to the approval of theEngineer-in-charge) consisting of C.P. brassUrinal waste Coupling dome type 32mm outerlength 75 mm , C.P. brass Urinal SpreaderOcular-Regular and C.P. brass tubeconnection 300 mm long complete. |
| 95 | Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm |
| 96 | Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineerin- charge ) dispensing hot/cold/ambient water including cost of two no. 20 ltrs packaged drinking water bottles and carriage complete in all respect. |
| 97 | Providing and fixing in position vitreouschinaware white lavatory suites of approvedmake (to the approval of Engineer-in-charge)consisting of C.P. brass waste 32mm dia withone C.P. brass pillar tap including Rack BoltScrew Pair 115mm long complete in allrespect. |
| 98 | Size 550 mm x 400 mm x 815 mm |
| 99 | Providing & fixing in position PVC flexible tubeconnection of approved make (to the approvalof Engineer-in-charge ) complete in all respect.PVC tube connection of size 15 mm x375 mm with PTMT nut |
| 100 | Providing and fixing P.V.C Waste PipeCollapsiable 32mm complete in all respect. |
| 101 | Providing and fixing in position towel rails /ring of approved make (to the approval ofEngineer-in-charge ) fixed in with rawl plugsembedded in walls with brass screwscomplete in all respect.C.P. brass with towel ring |
| 102 | Providing and fixing in position C.P. brasssoap dish of approved make (to the approvalof Engineer-in-charge ) fixed into wall with rawlplugs and C.P brass screws complete in allrespect. |
| 103 | Providing & Fixing in postion 15 mm i/d bibcock of approved make (to the approval ofEngineer-in-charge )complete in all respect.C.P. brass Bib cock foam flow withoutflange |
| 104 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 105 | C.P.brass 15mm Angle valve without flange |
| 106 | C.P.brass 15mm Concealed stop cock with flange. |
| 107 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 108 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge)with various fixtures complete in all respect. |
| 109 | C.P. Brass extension piece, 25mm long to 50mm long |
| 110 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) |
| 111 | Size 600mmx450mm |
| 112 | Providing and fixing in position premium rangeC.P. Brass Fittings and accessories ofapproved make (to the approval of Engineer-incharge) complete in all respect.C.P. Brass fittings: |
| 113 | C.P. brass Bib cock with Wall flange |
| 114 | C.P.brass 15mm Angular stop cock with Wall flange |
| 115 | C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body) |
| 116 | C.P. brass toilet roll holder with flap |
| 117 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 3 pegs |
| 118 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks 1000 ltr Capacity |
| 119 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball 32mm i/d |
| 120 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 121 | G.I. tank nipple 25mm i/d |
| 122 | G.I. tank nipple 50mm i/d |
| 123 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge For 1000 ltr Water Tank |
| 124 | Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.All Floor |
| 125 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material for ground floor new toilets |
| 126 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .Total All Floor |
| 127 | Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.Total All Floor |
| 128 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.Total All Floor |
| 129 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-Automatic Voltage Stablizer 2 KVAAutomatic Voltage Stablizer 4 KVA ( For AC's) |
| 130 | Providing & Installing & Erection split type wall mounted air conditioner with inverter technology capacity 1.50 tonne 5 Star having nature friendly R32 or equivelant 230 volts single phase supply witht MCB arrangement for installing OD units on terrace/Wall including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipe within building and installing charges complete in all respects |
| 131 | Providing laying hard soft copper concealing of copper pipes of various dia as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects.For 1.50 tonne split AC |
| 132 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.uPVC Pipe 10 Kgf/cm225mm i/d For 1.50 tonne split AC |
| 133 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm |
| 134 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by theEngineer-in-charge:-Overall size 4.0sq.mm (84/0.3mm), 3Core For 1.50 tonne split AC |
| 135 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 136 | Through wall 11.43 cm thick Detail as per Table-2 |
| 137 | Through wall 22.86 cm thick Detail as per Table-2 |
| 138 | Providing and Fixing water connection |
| 139 | Providing and fixing booster pump 0.5 HP |
| 140 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect .Earth work upto 1.5 m. Depth All classes of soil except rocky For 25mm pipe line |
| 141 | INTERNAL - EXPOSED ON WALL :Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval ofEngineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one stepPVC solvent cement and testing of pipes complete as per direction of Engineer-in- Charge. |
| 142 | SDR 11 CPVC pipes & fittings 25mm o/d |
| 143 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 144 | 110 mm o/d pipes For Sewer Line GT to IC 4mtr each 110mm |
| 145 | 160 mm o/d pipes For Sewer Line IC to IC and IC to MH 4mtr each |
| 146 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.For Sewer Line 110 mm dia and 160 mm dia MH to Septic Tank |
| 147 | Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.For covering Sewer Line Type II 100 mm i/d (Type-I)and 160mm i/d(Type-I) |
| 148 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. For pipes 100 to 250 mm Diametre Please Enable Macros to View BoQ information |
| 149 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. For pipes 100 to 250 mm Diametre Please Enable Macros to View BoQ information |