| Sl. No. | Item Description |
| 1 | Civil works |
| 2 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 meters complete in all respects & to entire satisfction of Engineer-in-Charge |
| 3 | Providing & laying Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type complete in all respects & to entire satisfction of Engineer-in-Charge |
| 4 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth complete in all respects & to entire satisfction of Engineer-in-Charge |
| 5 | Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded complete in all respects & to entire satisfction of Engineer-in-Charge |
| 6 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level complete in all respects & to entire satisfction of Engineer-in-Charge |
| 7 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 8 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 9 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 10 | Scraping Cement plaster |
| 11 | 20mm thick cement plaster 1:4 in two coat work |
| 12 | 12.5mm thick cement plaster 1:5 |
| 13 | Dismantling glazed tiles (to be carefully removed). |
| 14 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
| 15 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm. |
| 16 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) |
| 17 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing without cost of bitumen |
| 18 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded).. |
| 19 | Cost of new tile be replaced instead of broken tiles in regarding of tile terracing including loding /unloding and all leads as desired by engg. in charge |
| 20 | credit of brick Bats |
| 21 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps.U-PVC pipes 110 mm dia. |
| 23 | Providing and fixing 110 mm dia. SWR U.P.V.C Coupling/Sockets for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 24 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50 thick cement concrete 1:8:16 |
| 25 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge.IS Code : 15658 (2006) |
| 26 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.Doors of area 3 sqm and below. |
| 27 | Cridit of old doors. |
| 28 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.Windows of area 3 sqm and below |
| 29 | Credit of old windows |
| 30 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Double Rebateain Door |
| 31 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Single Rebateain Door |
| 32 | Hollock wood doors shutter windows shutter including hinges, screws, chocks,cheats, stops cords etc. complete fixed in position.panelled, glazed or glazed and panelled.35 mm thick |
| 33 | Wire gauge Hollock wood door shutter without springs housed in chowkhat.35 mm thick |
| 34 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 (a) Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-(iv) 35mm thick |
| 35 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 36 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. III (size of door 851mm to 1000mm) |
| 37 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area |
| 38 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 39 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 40 | Preparation of plywood surface for painting including sand papering the surface andapplying filling with approved quality fillers consisting of white lead, linseed oil, Varnish,and Chalk Mitti including finishing the surface to required finish complete. |
| 41 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade & applying priming coat with metal primer on new steel or iron work including preparation of surface |
| 42 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 43 | Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 44 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 45 | Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge. |
| 46 | Providing and fixing name plates of various size made of PVC Sheet printed with self adhesive tape pasted on sunboard complete as desired by engineer-in-charge |
| 47 | Providing and Fixing aam aadmi clinic board made with ACP sheet and lettering with Acrylic sheet complete in all respect. |
| 48 | PUBLIC HEALTH SERVICES |
| 49 | Dismantling Sanitary fixtures such as Eurpoean/Indian/Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge |
| 50 | Eurpoean/Indian/Orissa W.C., |
| 51 | PVC/ china ware Cistern |
| 52 | Wash hand basin/ Urinal pot |
| 53 | CP Bib cock /Angle Cock/Stop cock/Shower/Bottle Trap |
| 54 | Bathroom Assessories such as Soap Dish, Towel Rail, Towel Ring, Towel Bracket, Mirror, Toilet Paper Holder, Seat Cover, Jet Pressure and all other accessories. |
| 55 | Cutting holes upto 23cm square through B.B in cement walls or stone masonary wall in cement for pipes, and making good the same and finishing according to existing finish where required |
| 56 | Through wall 11.43 cm thick |
| 57 | Through wall 22.86 cm thick |
| 58 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.Size 75 mm X 75 mm |
| 59 | Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 60 | Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 61 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.With C.P. Brass nut |
| 62 | Providing and fixing in position 15mm C.P.Pillar cock foam flow of approved make |
| 63 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge |
| 64 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.Size 550 mm x 400 mm x 815 mm |
| 65 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste couplingcomplete in all respect.Rectangular Sink with DeluxeBorder Single Bowl Overall Size700 mm x 555 mm x 230 mm |
| 66 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
| 67 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 68 | C.P. brass Bib cock long nose/ long body foam flow without flange |
| 69 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 70 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respectC.P.brass 15mm Angle valve without flange |
| 71 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respectPVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
| 72 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 73 | Providing and fixing in position CP brass soap dish of approved make ( to the approval of engineer in charge) fixed into wall with rawl plugs and CP bras screws complete in all respect |
| 74 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 600mmx450mm |
| 75 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 76 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.C.P brass towel ring |
| 77 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect |
| 78 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect CP Brass extension piece 25mm long to 50 mm long |
| 79 | Providing and fixing 1st quality ceramic glazedwall tiles size 600 x 300 mm |
| 80 | Providing and laying vitrified floor tiles indifferent sizes in light colour shades made usingFull Body Technology. Size 600*600mm |
| 81 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.CPVC SDR 11 Pipe & fitting 20mm o/d |
| 82 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 83 | INTERNAL - EXPOSED ON WALL :Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes as per IS 15778SDR 11 CPVC pipes & fittings 32mmo/d |
| 84 | Providing and fixing in position singel socketSWR UPVC soil waste or antisyphonage pipesas per IS 13592Single Socket Type 90mm o/d SWR UPVC pipe lines laidcomplete |
| 85 | 110mm o/d SWR UPVC pipe lines laidcomplete |
| 86 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.For 110mm o/d pipesCoupler |
| 87 | single tee |
| 88 | Elbow 90 degree |
| 89 | P Trap/Floor Trap 110mm x 110mm |
| 90 | For 90mm o/d pipes Elbow 90 degree |
| 91 | Coupler |
| 92 | single tee |
| 93 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge)110mm |
| 94 | Providing and fixing in position PVC gully traps 100mm fixed in cement concrete 1:4:8 complete with SFRC cover with frame weighing 7.26 Kg. 300mm x 300mm including Grating complete in all respects. |
| 95 | Construction of brick masonry inspectionchambers size as given below upto 0.60metre average depth in 1:5 cement sandmortar,Size 450mm x 450mm |
| 96 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 97 | Platform for Placing water storage tank of 1000 ltr. complete in all respect |
| 98 | Providing & placing in position on terrace (atall floor levels) HDPE water storage tanks ofapproved make (to the approval of Engineer -in-charge) with cover with suitable lockingarrangement and making necessary holes forinlet, outlet and over flo pipes but withoutfittings and base support for tank.triple laye |
| 99 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball20mm i/d |
| 100 | 25mm i/d |
| 101 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.G.I. tank nipple 20mm i/d |
| 102 | G.I. tank nipple 25mm i/d |
| 103 | 12.5 mm thick cement plaster 1:4 |
| 104 | Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect |
| 105 | construction of septic tank (2.30x1x1.80) |
| 106 | Constructing soak pit 1.20x1.20x1.6 deep 230mm thick 1:5 brick work honey comb with bricks of 1st class filled with brickbats including sw drain pipe 100mm diameter and 1.20 mtr long complete as per standard drawing |
| 107 | Providing and fixing of FIRE EXTINGUISHER, ABC Powder type (stored pressure) as per IS: 15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect.4 Kg. Capacity |
| 108 | Excavation manually in trenches with straight or open cutting in a built up street/ lanes having wall to wall width upto 3 metre for sewers and manholes to full depths as shown in drawings, including shoring, dressing to correct sections and dewatering of rain water, provision for diversion for traffic, protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, dressing and restoration of surface to original level and removal of surplus spoils from the site of works upto 15 metre, for all works other than connections to complete in all respects. For depth not exceeding 2 m. below Ground level For all classes of soil except rocky |
| 109 | Credit of old materials |
| 110 | ELECTRICAL SERVICES |
| 111 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 112 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 113 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 114 | Wiring Computer terminal point having 2 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered) and 2Nos. 16/20Amp. switch with indicator (Modular accessories). |
| 115 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 116 | Wiring fan point (Without fan box) |
| 117 | Wiring light point |
| 118 | Wiring call-bell point |
| 119 | Wiring 6Amp. wall socket point |
| 120 | Wiring 6Amp. Plug control comprising wall socket point |
| 121 | Wiring 16/20Amp. power plug control point |
| 122 | PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 123 | Overall size 1.5sq.mm (Un-sheathed) |
| 124 | Overall size 2.5sq.mm (Un-sheathed) |
| 125 | Overall size 4sq.mm (Un-sheathed) |
| 126 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 127 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 128 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 129 | Ceiling Rose (Flush Piano type) |
| 130 | copper earthing:Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 131 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 132 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 133 | TP&N Horizontal Double Door Distribution Board 6 way each |
| 134 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 135 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 136 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 137 | OVER HEAD DISTRIBUTION ALUMINIUM CABLES, ACSR CONDUCTORS, CLAMPS, JUMPERS & JOINT KITS:Wiring over-head line in PVC insulated & PVC sheathed two single core aluminium conductor cable overall 1100 volts grade binding with G.I. wire 2mm dia. (14 SWG) with brass/ aluminium link clips complete in all respect as approved and desired by the Engineer In Charge at site. |
| 138 | PVC insulated & PVC sheathed aluminium conductor cable Overall Size 6mm² (1/1.40mm) Twin Core |
| 139 | AUTOMATIC VOLTAGE STABLIZER, TIMER:Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- |
| 140 | Automatic Voltage Stablizer 4 KVA |
| 141 | Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 142 | Supply and erection of 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 143 | Supply and erection of Heavy duty Exhaust Fans 300mm sweep 900RPM complete with aluminium louver shutter Canon Make, double ball bearing, longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 144 | Supply and erection of Suface Mounted 36 Watt LED 2x2 panel (including constant LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 145 | Supply and erection of LED Street Light 45watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 146 | supply installation and comissioning of 185 ltr capacity of above Direct cool single door Refrigerator Temp Setting Glass tray,ice maker,chilercbasketcbottle holders 5 year warranty on compressor,work without stabilicer,a AC 230V 50 HZ Iindian 10 A Socket. Complete in all respect as approved and desired by engineer in charge st site |
| 147 | supply installation and comissioning of Inverter sine wave 2300VA with 2 nos 160 AH Tublar battery with ensures long life.The unit includes extra thick gauntlets are strong and flexible as well as oxidation resistant and suitable for charging 12 volts DC power backup with 3 year warranty (for battery) & 1 year warranty (for inverter) Period including connection & testing charge etc. Complete in all respect as approved and desired by engineer in charge st site |
| 148 | supply ,installation testing and comissioning of split air conditioner inverter type units 1.5TR capacity, 3star rating ,indoor and out door unit , out door stand and 3 meter refrigerant pipe & copper wire with 1 year warranty . complete in all respects as approved and desired by engineer in charge at site |
| 149 | supply installation and comissioning of Copper pipe with wire for Air Conditioner Complete in all respect upto the entire satisfaction of the Engineer in charge at site Total A+B+C Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail