| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Dismantling & Demolishing |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 6 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge |
| 7 | Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead |
| 8 | RCC WORK |
| 9 | Providing and laying in position machine batched and machine mixed design mix M25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | FORM WORK |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 13 | STEEL WORK |
| 14 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 15 | MASONRY WORK |
| 16 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 17 | PLASTERING |
| 18 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 19 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 20 | DOORS & WINDOWS |
| 21 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm |
| 22 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mmm |
| 23 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 24 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. |
| 25 | Providing and fixing of vertical/roller blinds width 100 mm regular quantity made from 100 % polyster/Fibre yarn coated with fade resistant polymer to ensure complete opaquety with zero light transmittance, having suitable coating on exterior, including all fixtures and fittings complete in all respect as per design and instruction of Engineer in-charge and as per site conditions. The colour will be approved by the competent authority Make-MAC/VISTA/NOVA or any equivalent make. |
| 26 | Supplying and laying polyester, washable and stain free cloth(Bio-Active fabric washable germ free suitable for sterile area) curtain curtain system with maximum curtain curtain cloth height 230 cm(top 30 cm white colour net and 200cm light blue color as per approval) stitching with stifiner tape, pleats, ironing and laying around each bed using PVC runner with hooks & stopper for hanging/sliding etc. as per the direction of engineer in charge including conveyance to site, laying in line and level, sealing all cutting in false ceiling with powder coated MS cup, all leads and lifts including all labour charges etc. complete. (unpleated length of the cloth measurement will be considered for payment also the bottom and top foldings will not be considered in cloth measurement)/ supplying and fixing powder coated 20mm dia. GI round tube hanging support of required length(app. length 1.10m) one end fixing from slab by using 6mm dia expansion bolt at a distance not more than 2m, c/c down end fixed to powder coated aluminium channel frame 45 x 20mm x 1mm thick section by using SS screw as per the direction of engineer in charge including conveyance |
| 27 | Providing and fixing panelling or Providing and fixing panelled or Making Shelf, Racks, Tables, etc (Area of opening for panel excluding portion inside grooves or rebates to be measured): Marine Ply wood , 18 mm thick with laminated Finish. |
| 28 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick |
| 29 | Providing and fixing Thomson Multi wood board or equivalent make, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately) as per the direction of site Engineer-in-charge |
| 30 | Providing and fixing powder coated telescopic drawer channels(pair) 300 mm long with necessary screws etc. complete as per directions of Engineerin-charge. |
| 31 | Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Size 50 mm. |
| 32 | Providing and fixing magnetic catcher of approved quality in cupboard /ward robe shutters, including fixing with necessary screws etc. complete. Triple strip vertical type. |
| 33 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:75 mm |
| 34 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame |
| 35 | Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. |
| 36 | ALUMINIUM WORK |
| 37 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 38 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 39 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 40 | Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): toughened glass of 6 mm thickness. |
| 41 | Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete |
| 42 | Providing and fixing frosted film in the fixed glass etc. Complete as per the direction of departmental officers |
| 43 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 44 | WALL TILE |
| 45 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. completeSize of Tile 1000x1000 mm |
| 46 | FLOORING |
| 47 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1000x1000 mm |
| 48 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joint treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm |
| 49 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 50 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge Size of Tile 1000x1000 mm |
| 51 | FALSE CEILING & CLADDING |
| 52 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer39;s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board |
| 53 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 54 | PAINTING |
| 55 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 56 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 57 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 58 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 59 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 60 | PLUMBING & SANITARY FITTINGS |
| 61 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall |
| 62 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 |
| 63 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed/ Concealed on wall |
| 64 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :15mm nominal bore |
| 65 | Providing and fixing Polypropylene laboratory sink with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required : 20.9 x 15.3 x 11.1 inches; 2.26 Kg. |
| 66 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore |
| 67 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes |
| 68 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes |
| 69 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 70 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 71 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms. |
| 72 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 73 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms |
| 74 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 40 mm dia |
| 75 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 263gms. |
| 76 | Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore |
| 77 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 78 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 79 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 80 | Providing and fixing PTMT grating of approved quality and colour. Circular type100 mm nominal dia |
| 81 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 82 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 83 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 84 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 85 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 86 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm Dia Y |
| 87 | Providing and fixing PPR Unions- PPR Union 110mm |
| 88 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 89 | SIGNAGES |
| 90 | Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs of Size 16\\" x 10\\". Complete as per the per the direction of Engineer in charge. |
| 91 | EYEWASH UNIT |
| 92 | Providing, supplying and installing Laboratory Emergency Eye Wash Unit of modular design, constructed from brass and stainless steel components with chemical resistant polyester powder coated (Polycoat) finish resistant to laboratory chemicals and UV radiation. The unit shall be provided with a stainless steel bowl with integrated outlet and dual aerated spray heads designed to deliver a soft and uniform water flow for effective eye flushing. Spray heads shall be manufactured from Noryl GFN-3 (PPO) or equivalent corrosion resistant material and shall be provided with protective dust covers and self draining feature. Internal piping shall be made of polypropylene (PP) and the unit shall incorporate an integrated flow regulator (FLOWFIX or equivalent) to maintain a controlled water flow of approximately 26 litres per minute. The eye wash unit shall operate at a minimum working pressure of 1.5 bar and shall be suitable for 1 inch threaded water inlet connection. All exposed metal parts shall be coated with chemical resistant polyester powder coating of minimum 50 micron thickness, finished in high visibility signal red colour (RAL 2002). The unit shall be operated through push plate / hand lever activation for quick operation in emergencies.The eye wash unit shall be provided with night visible green emergency signage and usage pictogram and shall comply with EN 15154 Part 2 and ANSI Z358.1 standards. The manufacturer shall be ISO 9001 certified.Approved Make: BROEN or equivalent approved drawings and site requirements. |
| 93 | FURNITURES |
| 94 | Providing & Fixing mid back chair with ergonomic revolving chair with five-star nylon base, 50 mm dia. nylon twin-wheel castors, pneumatic gas-lift height adjustment, back-angle adjustment, 2 D adjustable armrests, PU-moulded foam seat, mesh backrest, and heavy-duty rubber-backed fabric upholstery in Black, complete as per standard specifications and as directed by the Engineer-in-Charge. |
| 95 | Providing & Fixing table of size 5.58 ft X 2.5ft made up of 18mm particle board with lamination on both sides. Side partitions, drawers, racks, lock and laches etc including all complete both side laminated top. with 18 mm thick door and 9 mm thick both side laminated drawer bottom and back panel including necessary approved hinge, telescopic slide ,multipurpose lock ,hanger rod of 25mm dia 16 gauge nickel plated MS Pipe ,2nos. tower bolt of barrel type having size 150 x 10mm, 4 nos. magnetic catcher triple strip vertical type of approved quality, 128 mm handle , kd/minifix fitting, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand fixture and finishing etc.. complete job. as per approved shade and colour and as per Architecture drawing and Engineer in Charge. |
| 96 | Supply of SS Revolving Stool with 100 Kg Capacity of 300mm seat dia, Height adjustable 450mm to 680mm. 3 legs tubular base, Revolving top, Legs fitted with shoes 16 & 18 Guage Pipe, 1Mm Sheet. |
| 97 | Providing & Fixing 3 seater stainless steel chair. Silver colour with seating capacity 3 SS 201 grade (or better) steel perforated seat sheet and back rest and arm rest. Suitable for heavy public use. Should be ISO certified manufacturer. Width of seat 52cm to 55cm, height from ground 79cm. |
| 98 | Providing, fabricating, supplying and installing Slotted Angle Storage Racks made from high-quality mild steel slotted angles of minimum 2.0 mm thickness, conforming to standard storage rack specifications. The vertical members shall be formed from slotted MS angles of size 40 mm × 40 mm × 2 mm or equivalent, with uniformly punched slots at regular intervals to facilitate adjustable shelving. The racks shall be provided with horizontal tie members and bracings made from MS flat/angle sections to ensure structural rigidity and load stability. Shelves shall be fabricated from 18 gauge (1.2 mm thick) mild steel sheet with folded edges on all sides for strength and safety. Each shelf shall be adjustable at suitable intervals and capable of carrying a uniformly distributed load of minimum 80–100 kg per shelf. All components shall undergo surface preparation including cleaning and phosphating, followed by Epoxy Polyester Powder Coating of minimum 60–70 microns thickness in approved colour to ensure corrosion resistance and durability. The rack shall typically consist of 5 adjustable shelves, overall height 2000 mm, depth 450–600 mm, and length 900–1200 mm, assembled with high tensile nuts and bolts complete in all respects as per approved layout and site requirements. The work shall include supply, installation, alignment and fixing of racks with all necessary accessories and hardware for proper installation. Approved Make: Godrej / Ezy Rack / or equivalent approved make. |
| 99 | WORKSTATION |
| 100 | Providing, fabricating, supplying and installing Laboratory Modular Work Table fabricated from 1.2 mm thick Electro-Galvanized Iron (EGI) sheet with 120 GSM zinc coating, wrinkle-free and double skin pass, using steel from TATA / POSCO / Jindal or equivalent approved make. All metal components shall undergo an 8-tank surface pretreatment process followed by Epoxy Polyester Powder Coating of 70–80 microns thickness applied through a conveyor operated automated powder coating system to ensure high resistance to corrosion, chemicals and abrasion for both internal and external surfaces. The work table shall be provided with modular cabinets of standard width of 750 mm to 900 mm and height 775 mm for instrument tables or 875 mm for wet chemistry tables. Doors and drawer front panels shall be of double wall sound-deadening sandwich construction. The worktop shall be 16 mm thick chemical resistant laboratory grade surface manufactured using Electron Beam Cured technology, free from melamine and conforming to SEFA 3.0 chemical resistance standards, preferred make Trespa or equivalent, OR 18 (+1) mm thick mirror polished jet black granite with half round bullnose edge finishing on exposed sides. Provision of reagent racks with stainless steel rods and 10 mm thick toughened glass shelves: 150 mm wall-side two-tier rack, 300 mm double side two tier rack. The racks shall be adjustable and the glass shelves removable for cleaning and maintenance. The workstation shall be complete with SS 304 five-knuckle hinges (SEFA approved) and powder coated soft closing drawer slides with minimum 30 kg load capacity, make Hettich / Häfele / Ebco, and recessed aluminium handles with epoxy powder coated or brushed aluminium finish, including all electrical LAN, Plumbing and other necessary accessories, fixtures and fittings for complete installation as per approved drawings and site requirements. |
| 101 | Providing, fabricating, supplying and installing Laboratory Overhead Cabinets fabricated from 1.2 mm thick Electro-Galvanized Iron (EGI) sheet with 120 GSM zinc coating, wrinkle-free and double skin pass, using steel from TATA / POSCO / Jindal or equivalent approved make. All metal components shall undergo an 8-tank surface pretreatment process followed by Epoxy Polyester Powder Coating of 70–80 microns thickness applied through a conveyor operated automated powder coating system to ensure resistance to corrosion, chemicals and abrasion for both internal and external surfaces. The cabinets shall be wall mounted modular units with standard width of 350mm and height 450 - 600 mm suitable for laboratory storage above work benches.Doors shall be double wall construction with sound deadening sandwich design and shall be provided with toughened glass viewing panels (where specified) to allow visibility of stored materials. Internal shelves shall be fabricated from EGI sheet with epoxy polyester powder coating and shall be adjustable for height.The cabinet shall be complete with SEFA approved SS 304 five-knuckle hinges, soft closing mechanism, and recessed aluminium handles with epoxy powder coating or brushed aluminium finish, make Hettich / Häfele / Ebco or equivalent approved. The overhead cabinets shall be securely mounted to wall or structural support using suitable heavy duty brackets and anchor fasteners, complete with all accessories, fixtures and fittings required for proper installation as per approved drawings and site requirements. |
| 102 | ELECTRICAL WORK |
| 103 | Point wiring in PVC conduit with modular type switch. |
| 104 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 105 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 106 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 107 | Wiring through PVC conduit |
| 108 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2X1.5 sq.mm + 1X1.5 sq.mm earth wire |
| 109 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2X2.5 sq.mm + 1 X2.5 sq mm earth wire |
| 110 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2X4 sq.mm + 1X4 sq.mm earth wire |
| 111 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2X6 sq.mm + 1X6 sq.mm earth wire |
| 112 | Modular type blanking plate: |
| 113 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 114 | Modular boxes, bases & cover plate: |
| 115 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 2 module |
| 116 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 module |
| 117 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 module |
| 118 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface |
| 119 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 3 module moulded plastic box on surface |
| 120 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 6 module moulded plastic box on surface |
| 121 | Modular type switch/socket: |
| 122 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.5/6 Amps switch |
| 123 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.3 pin 5/6 Amp socket outlet |
| 124 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.15/16 Amps switch |
| 125 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.6pin 15/16 Amps (universal) socket outlet |
| 126 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.Telephone socket outlet |
| 127 | DB Accessories |
| 128 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 129 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door |
| 130 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required. Single pole |
| 131 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 132 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A |
| 133 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A-40A, 4P, 100mA |
| 134 | Supplying and fixing FP sheet steel enclosure on surface/ recess along with 40 amps 415 volts ,FP Isolator complete with connections, testing and commissioning etc. as required. |
| 135 | Supplying and fixing FP sheet steel enclosure on surface/ recess along with 40 amps 415 volts ,FP Isolator complete with connections, testing and commissioning etc. as required. |
| 136 | EARTHING |
| 137 | Providing and fixing 10 SWG dia Cu wire on surface or in recess for loop earthing as required. |
| 138 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 139 | SUPPLY OF LT CABLES |
| 140 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3½ X 35 sq. mm |
| 141 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 25 sq. mm |
| 142 | Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 16 sq. mm |
| 143 | CABLE LAYING |
| 144 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 145 | LT CABLE TERMINATION |
| 146 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 35 sq. mm (32mm) |
| 147 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 148 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 149 | CABLE TRAYS |
| 150 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray(Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 151 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 152 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 153 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Cross member\\"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 154 | LIGHT FITTINGS & FANS |
| 155 | SITC of 2x 2 LED Recess mounted 36W light fixture, system efficacy >110 lm/W and system lumen output not less than 3600 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distributionwith CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor >/=0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI>80, UGR <19, SDCM<5 and CCT in between 4000K to 5700K.Luminaire shall be flicker free with ripple factor < 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make. |
| 156 | SITC of LED recessed downlight fixture Maximum 18W (+/-2) light fixture. System efficacy >110 lm/W and system lumen output not less than 1980 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor >/= 0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, UGR <19, SDCM<5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLSPVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same |
| 157 | SITC of LED recessed downlight fixture Maximum 10W (+/-2) light fixture. System efficacy >110 lm/W and system lumen output not less than 1100 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor >/= 0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, UGR <19, SDCM<5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLSPVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same |
| 158 | SITC of 4 feet surface mounted batten type luminaire with a power consumption not more than 20 W, luminaire lumen output of 1200 lumens, luminaire efficacy > 120 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design with width not more than . The luminaire shall have a CCT of 4000K ,6500 K , power factor ;0.95, SDCM < 5, THD 10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content 5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 kV. The luminaire shall have Class - 1 Electrical Insulation, Class - B Serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. |
| 159 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speedcontrol and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 160 | SITC of 450mm sweep Wall fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply complete with continuous duty motor and all accessories including mounting as required for complete installation. |
| 161 | Supply installation, testing and commissioning of following three phase to three phase UPS with indoor (IP20) in stand alone configuration,true online double conversion DSP based UPS system, with min 30 min backup battery with, input pf .9, less input current consumption, IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency 90% and output power factor;0.9 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 15 kVA Double conversion online ups - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc. |
| 162 | ELV SYSTEMS |
| 163 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 164 | Supply, Fixing, Testing & Commissioning of CAT6 (RJ-45) I/O Ports |
| 165 | Supply,Installation,Testing & Commissioning of CAT6 Patch Cord with Moulded boots, Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 2 Meter |
| 166 | Supply, Installation, Testing & Commissioning of 4U Network Rack with below specifications as minimum and all the necessary accessories: - Lock & Keys - Tray (1 No) - 1 Cooling Fan and Adjustable Shelf - Height - 4U - Dimensions - 13x12x11 cm - Fan Units with 1coolin Fans - PDU 6 point - 1 Nos's - Mounting Hardware Kit (1 lot) - Tray - Front glass doors and back steel door and side panels |
| 167 | Supply, Installation, Testing & Commissioning of 16 Port Network Switch with 16 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink |
| 168 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required..Telephone socket outlet |
| 169 | Supply , Installation of PBX System with below features and accessories- 1 PRI Port(T1/E1) expandable upto 4 PRI ports - 4 Analog Trunk Lines- Extensions - 16 ( Analog or IP as required ) |
| 170 | Supply of User Phone- Analog phone |
| 171 | CCTV SYSTEM |
| 172 | Supplying Installation Testing and Commissioning of 2MP IP IR Dome Camera having followingspecifications, type of lens and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio:>50 dB, Camera should display Camera title, Date &Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive ScanCMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better,H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming, configurable (Main stream: 2MP (1920×1080)@25/30 fps,Sub streams minimum:720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness,contrast, sharpness adjustable through client softwareor web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection8) Cyber Security: AES 256-bit Encryption,Configuration encryption, trusted execution, Digest,security logs, account lockout, syslog, videoencryption, IP/MAC filtering, HTTPS, trusted upgrade,trusted boot.9) Onboard Storage: Camera should support built-inMicro SD/SDHC/SDXC Card slot upto 512 GB. Itshould be supplied with minimum 128GB memoryCard.280 10) Recording Management: Format SD, overwrite, storage management, video to NAS device 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast13) System Capability: ONVIF, Camera shall supportopen source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1Alarm In/ Out for External Mic. and Speakers as persite requirement.16) Power Input: The camera should supportsimultaneous dual power input—12 VDC (via poweradapter) and PoE (802.3af)—to ensure continuousoperation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE(802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens |
| 173 | SITC OF 16 CH NVR With Dual-OS design to ensure high reliability of system running and ANR technology to enhance the storage reliability when the network is disconnected with HD input of H.265/ H.265+/H.264/H.264+/MPEG4 video formats , Connectable to the third-party network camera Up to 16 IP cameras can be connected Recording at up to 8 MP resolution, Supports live view, storage, and playback of the connected camera at up to 8 MP resolution with HD storage of Up to 2 SATA interfaces connectable for recording and backup, Storage space effectively saved by 50% to 70% with the use of H.264+ decoding format and HD transmission of 1 self-adaptive 10 M/100 M/1000 Mbps network interface with Centralized management of IP cameras, including configuration, information import/export, real-time information display, two-way audio, upgrade, etc. Connectable to smart IP cameras from Hikvision and the recording, playing back, and backing up of VCA alarms can be realized CE certified. |
| 174 | SITC OF 32 CH NVR With Dual-OS design to ensure high reliability of system running and ANR technology to enhance the storage reliability when the network is disconnected with HD input of H.265/ H.265+/H.264/H.264+/MPEG4 video formats , Connectable to the third-party network camera Up to 32 IP cameras can be connected Recording at up to 8 MP resolution, Supports live view, storage, and playback of the connected camera at up to 8 MP resolution with HD storage of Up to 2 SATA interfaces connectable for recording and backup, Storage space effectively saved by 50% to 70% with the use of H.264+ decoding format and HD transmission of 1 self-adaptive 10 M/100 M/1000 Mbps network interface with Centralized management of IP cameras, including configuration, information import/export, real-time information display, two-way audio, upgrade, etc. Connectable to smart IP cameras from Hikvision and the recording, playing back, and backing up of VCA alarms can be realized CE certified. |
| 175 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, video storage 8TB ,, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 176 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 177 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 9 U rack |
| 178 | Supply, Installation, Testing & Commissioning of 16 Port Network Switch with 16 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink |
| 179 | Supply, Installation, Testing & Commissioning of 32 Port Network Switch with 32 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink |
| 180 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make20 mm |
| 181 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make25 mm |
| 182 | Supply, Installation, Testing and Commissioning of aircooled VRV (Variable Refrigerant Volume) / VRF (Variable Refrigerant Flow) outdoor units (ODUs) equipped with highly efficient, full DC inverterdriven scroll compressors only, aircooled heat exchangers having internally grooved copper tubes, and lownoise condenser fans. The units shall have autoaddressing, an autocheck function for connection errors, and operate with R410A or equivalent refrigerant gas. Each unit shall be fitted with a noise filter, highpressure switch, fan motor overload protector, overcurrent relay, inverter overload protector, and other necessary protective devices. Power failure of one or more IDU shall not affect operation of other units / circuit. The units shall deliver the rated capacity in accordance with IS 18728:2024 and CPWD specifications. The efficiency of the ODUs shall meet the latest ECSBC/ASHRAE standards. Suitable vibration isolators shall be provided with the ODUs. The system shall operate at outdoor conditions up to a minimum ambient drybulb temperature of 50°C. Each unit shall be equipped with an oil recovery system to ensure stable operation with long refrigeration piping lengths, and provided with an oilbalancing circuit to prevent inadequate lubrication. Compatibility with centralized control systems such as BACnet, LonWorks, and Modbus is required. The ODUs shall be suitable for a 3phase, 415V, 50Hz power supply, with suitable interconnecting control cabling between IDUs, ODUs, and the central controller. All necessary power cabling up to the ODU electrical panel, pressure testing, additional refrigerant charging for commissioning, and all associated accessories required for commissioning shall be included in the scope of work. The VRF outdoor unit circuit schedule shall be as per the tender drawings/specifications. |
| 183 | Supply, Installation, Testing, and Commissioning of VRV/VRF 0.8 TR high-wall type indoor unit complete with a corded/cordless remote (subject to consultant's approval). The machine shall be suitable for operation on 230 V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multi-speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories, etc.. |
| 184 | Supply, Installation, Testing, and Commissioning of VRV/VRF 1.0TR high-wall type indoor unit complete with a corded/cordless remote (subject to consultant's approval). The machine shall be suitable for operation on 230 V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multi-speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories, etc.. |
| 185 | Supply, Installation, Testing, and Commissioning of VRV/VRF 1.3TR high-wall type indoor unit complete with a corded/cordless remote (subject to consultant's approval). The machine shall be suitable for operation on 230 V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multi-speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories, etc.. |
| 186 | Supply, Installation, Testing, and Commissioning of VRV/VRF 2.0TR high-wall type indoor unit complete with a corded/cordless remote (subject to consultant's approval). The machine shall be suitable for operation on 230 V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multi-speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories, etc.. |
| 187 | Supply, Installation, Testing, and Commissioning of VRV/VRF 2.0TR Cassette Type Indoor Ceiling Mounted Units along with a Cordless Remote. The machine should be equipped with a synthetic washable media pre-filter, a multi-speed motor, a DX copper coil, an electronic expansion valve, and an insulated drain pan as required. The unit is to be enclosed in a powder-coated cabinet. The blower shall be dynamically balanced and designed for silent operation. The address of the indoor unit shall be set automatically in case of individual and group control. The units should be suitable for operation on a single-phase, 230V, 50Hz supply. The machine should include a high-lift drain pump as necessary, a drain connection with a U-trap, and all necessary fittings, elbows, electrical cabling from the power plug, and structural supports, etc |
| 188 | Supply, Installation, Testing, and Commissioning of VRV/VRF 3.2TR Cassette Type Indoor Ceiling Mounted Units along with a Cordless Remote. The machine should be equipped with a synthetic washable media pre-filter, a multi-speed motor, a DX copper coil, an electronic expansion valve, and an insulated drain pan as required. The unit is to be enclosed in a powder-coated cabinet. The blower shall be dynamically balanced and designed for silent operation. The address of the indoor unit shall be set automatically in case of individual and group control. The units should be suitable for operation on a single-phase, 230V, 50Hz supply. The machine should include a high-lift drain pump as necessary, a drain connection with a U-trap, and all necessary fittings, elbows, electrical cabling from the power plug, and structural supports, etc |
| 189 | Supply, Installation, Testing, and Commissioning of VRV/VRF 1.0 TR,1-Way Cassette Type Indoor Ceiling Mounted Units along with a Cordless Remote. The machine should be equipped with a synthetic washable media pre-filter, a multi-speed motor, a DX copper coil, an electronic expansion valve, and an insulated drain pan as required. The unit is to be enclosed in a powder-coated cabinet. The blower shall be dynamically balanced and designed for silent operation. The address of the indoor unit shall be set automatically in case of individual and group control. The units should be suitable for operation on a single-phase, 230V, 50Hz supply. The machine should include a high-lift drain pump as necessary, a drain connection with a U-trap, and all necessary fittings, elbows, electrical cabling from the power plug, and structural supports, etc |
| 190 | Supply, Installation, Testing, and Commissioning of VRV/VRF 1.5 TR,1-Way Cassette Type Indoor Ceiling Mounted Units along with a Cordless Remote. The machine should be equipped with a synthetic washable media pre-filter, a multi-speed motor, a DX copper coil, an electronic expansion valve, and an insulated drain pan as required. The unit is to be enclosed in a powder-coated cabinet. The blower shall be dynamically balanced and designed for silent operation. The address of the indoor unit shall be set automatically in case of individual and group control. The units should be suitable for operation on a single-phase, 230V, 50Hz supply. The machine should include a high-lift drain pump as necessary, a drain connection with a U-trap, and all necessary fittings, elbows, electrical cabling from the power plug, and structural supports, etc |
| 191 | Supply and Installation of INDOOR Refnet / Y-joint separation tubes for refrigeration pipe joints and headers in appropriate orientation to enable proper distribution of refrigerant. The distribution joints should be factory insulated with pre- formed section of expended polystyrene / equivalent. |
| 192 | Supply and Installation of OUTDOOR Refnet / Y-joint separation tubes for refrigeration pipe joints and headers in appropriate orientation to enable proper distribution of refrigerant. The distribution joints should be factory insulated with pre- formed section of expended polystyrene / equivalent. |
| 193 | Supply, Installation, Testing and Commissioning of Centralized Type Remote Controller, color touch screen type with UPS battery backup, all inclusive of necessary installation supports and wiring. The controller must function as an advanced air conditioning management system, providing complete control of VRV/VRF air conditioning equipment (including connected AHUs). It should offer user-friendly operation through its touch screen, icon display, and color LCD display. Units shall be compatible with either BACnet, LonWorks or MODBUS interface. The controller is required to control up to 64 groups of indoor units with the following functions: 1. Starting/stopping of air conditioners as a zone or group or individual unit. 2. Temperature settings for each indoor unit or zone. 3. Switching between temperature control modes, fan speed adjustment, and airflow direction control, including enabling/disabling of individual remote controller operation. 4. Monitoring of operation status, such as operation mode, temperature settings of individual indoor units, maintenance information, and troubleshooting details. 5. Scheduling Indoor Unit Operating Time 6. Displaying air conditioner operation history. |
| 194 | Supply, Installation, Testing, and Commissioning of Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:1/4 inch (6.35 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications. |
| 195 | Supply, Installation, Testing, and Commissioning of Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:3/8 inch (9.52 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications. |
| 196 | Supply, Installation, Testing, and Commissioning of Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:1/2 inch (12.7 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications. |
| 197 | Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:5/8 inch (15.88 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications. |
| 198 | Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:3/4 inch (19.05 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications. |
| 199 | Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:7/8 inch (22.2 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications. |
| 200 | Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1.0 inch (25.4 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications. |
| 201 | Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/8 inch (28.6 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications. |
| 202 | Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/4 inch (31.8 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications. |
| 203 | Supply, Installation, Testing, and Commissioning of Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-3/8 inch (34.9 mm) gas/liquid copper insulated piping. The insulation for copper lines shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values of pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of FACTORY LAMINATED FIBRE GLASS CLOTH. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line as per the specifications between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing on walls, etc., as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y- joints, supports, refnets, and wall clamps, etc., for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings should match the pipe thickness. PVC SLEEVES shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed in all respects as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all the refrigerant pipes installed are in accordance with the Original Equipment Manufacturers (OEM) technical/recommended specifications. |
| 204 | Supply, laying, and testing of shielded copper flexible communication/transmission cabling between VRF indoor units and outdoor units. The communication cable must be routed through PVC conduit. The sizing of the cable to be 2 Core x 1.5 SQMM (or) as per VRF-OEM's technical/recommended specification. |
| 205 | Supply Installation Testing and Commissioning of Condensate Drain Pump, with the following parameters - Max. flow 550L/h @ 0 head, Max. rec. head 5m. Single Phase Supply . All inclusive of accessories, wiring etc. necessary for fixing of the unit |
| 206 | Supply, Installation, testing and commissioning of 25mm dia rigid UPVC condensate drain pipes duly insulated with 9mm thick closed cell nitrile finished with 7mils FACTORY LAMINATED GLASS CLOTH along with necessary U-trap,clamps, fittings such as bends, tees etc. adequately supported complete as required confirming to specification. |
| 207 | Supply, Installation, testing and commissioning of 32mm dia rigid UPVC condensate drain pipes duly insulated with 9mm thick closed cell nitrile finished with 7mils FACTORY LAMINATED GLASS CLOTH along with necessary U-trap,clamps, fittings such as bends, tees etc. adequately supported complete as required confirming to specification. |
| 208 | Supply, Installation, testing and commissioning of 40mm dia rigid UPVC condensate drain pipes duly insulated with 9mm thick closed cell nitrile finished with 7mils FACTORY LAMINATED GLASS CLOTH along with necessary U-trap,clamps, fittings such as bends, tees etc. adequately supported complete as required confirming to specification. |
| 209 | Supply and application of two coats of vapor barrier (Foster Painting ) on exposed ducts /copper refrigerant pipelines, as per the directions of the Engineer-in-Charge. The work includes surface preparation, application of vapor barrier coating and related works to ensure full coverage and protection. |
| 210 | FIRE DETECTION & ALARM SYSTEM |
| 211 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required(other areas & above ceiling) |
| 212 | Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 213 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 214 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 4 ZONE |
| 215 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 216 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 217 | Supplying, installing and commissioning Co2 type Fire Extinguisher, made from brand new seamless Steel cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Wheel type valve with initial Charge and mounted on Rubber Wheels / wall mounted brackets as per IS: 16018 specification, bearing ISI Mark. 4.5 Kgs |
| 218 | Supply and fixing of 4Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 15683 with Fire rating 1A 8B, Body Hydrotested at 35 bar, Operating temperature -30°C to +55°C, external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail