| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-04-2026 | CORRIGENDUM NO 1 | Date | 22-04-2026 |
| Sl. No. | Item Description |
| 1 | CHAPTER - I EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.(No additional lift payment will be given for mechanical excavations) |
| 3 | All kinds of soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (No additional lift payment will be given for mechanical excavations) |
| 5 | Ordinary rock |
| 6 | Hard rock (blasting prohibited) |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (No additional lift payment will be given for mechanical excavations) |
| 8 | All kinds of soil |
| 9 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. (No additional lift payment will be given for mechanical excavations) |
| 10 | Ordinary rock |
| 11 | Hard rock (blasting prohibited) |
| 12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (5% voids to be deducted) |
| 13 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 14 | Supply and filling of approved earth (Including royalty) obtained from outside MD land for formation of sub base including spreading in layers not exceeding 200mm in thick,necessary watering,consolidation to the required level,gradient and camber with 8-10 Tonne road roller to achieve minimum of 95% proctor density including cost of excavation all as per specifications and drawings at all lead and lift and as directed by the Engineer.(Payment shall be made for consolidated quantity after deduction of 5% for voids.) |
| 15 | Supplying chemical emulsion in sealed containers including delivery as specified. |
| 16 | Chlorpyriphos/Lindane emulsifiable concentrate of 20% |
| 17 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 18 | Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: |
| 19 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 20 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor. |
| 21 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 22 | Credit for Rock |
| 23 | CHAPTER - II PLAIN AND REINFORCED CEMENT CONCRETE WORK. |
| 24 | Providing and laying in position cement concrete of specified grade the excluding cost of centering and shuttering - All work up to plinth level: |
| 25 | 1:4:8 (1 Cement : 4 coarse sand derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 26 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: |
| 27 | 1:1½:3 (1 cement : 1½ coarse sand derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 28 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand derived from natural sources: 4 graded stone aggregate 12.5 mm nominal size derived from natural sources) |
| 29 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification |
| 30 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 31 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 32 | Foundations, footings, bases of columns, etc. for mass concrete |
| 33 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 34 | Suspended floors, roofs, landings, balconies and access platform |
| 35 | Shelves (Cast-in-situ) |
| 36 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 37 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 38 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 39 | Edges of slabs and breaks in floors and walls, under 20 cm wide. |
| 40 | Weather shade, Chajjas, corbels etc., including edges |
| 41 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). |
| 42 | Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 43 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all height & level.. |
| 44 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 45 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 46 | All works upto plinth level |
| 47 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 48 | All works above plinth level upto floor V level |
| 49 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 50 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 51 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 52 | Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement: 4 fine sand). |
| 53 | Deduct for difference price for using of manufactured sand instead of coarse sand derived from natural sources . |
| 54 | CHAPTER - III BRICK WORK: |
| 55 | Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with : |
| 56 | Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 57 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 58 | Cement mortar 1:6 (1 cement : 6 Coarse sand) |
| 59 | Brick work with non modular fly ash bricks conforming to 13:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : |
| 60 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 61 | Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in superstructure above plinth upto floor V level. |
| 62 | Cement mortar 1:4 (1 Cement : 4 coarse sand) |
| 63 | Extra for providing and placing in position 2 Nos. 6mm dia MS bars at every third course of half brick masonry. |
| 64 | CHAPTER - IV DOOR & WINDOW WORK : |
| 65 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 66 | For fixed portion |
| 67 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 68 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) |
| 69 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 70 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particale board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters & partition frame with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of Engineer-in-charge. |
| 71 | Prelaminated particle board with decorative lamination on both sides. |
| 72 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): : |
| 73 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 74 | With 6 mm thick Toughened Glass |
| 75 | 6mm thick wired glass |
| 76 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D.F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 77 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 78 | Providing and fixing oxidised M.S. casement window fastener with necessary screws etc. complete. |
| 79 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 80 | 300 mm weighing not less than 330 grams |
| 81 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length . |
| 82 | Kiln seasoned and chemically treated hollock wood. |
| 83 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 84 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 85 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 86 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 87 | Kiln seasoned and chemically treated hollock wood |
| 88 | 50x20 mm |
| 89 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 90 | 10x80 mm |
| 91 | 10x120 mm |
| 92 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 93 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 94 | Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of Approved Quality) |
| 95 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 96 | 300x16 mm |
| 97 | 250x16 mm |
| 98 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 99 | 200x10 mm |
| 100 | 150x10 mm |
| 101 | 100x10 mm |
| 102 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 103 | 125 mm |
| 104 | 100 mm |
| 105 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 106 | Twin rubber stopper |
| 107 | Providing and fixing of rubber nylon door buffer (dia of 40mm and 50mm long) on wall with rowl plug and screw. |
| 108 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. |
| 109 | Fixed to steel windows by welding |
| 110 | Fixed to openings / wooden frames with rawl plugs (designation 10 No.) etc., all complete. |
| 111 | Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 112 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 Kg to 80 Kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. |
| 113 | Providing and fixing aluminium casement window fastener of required length for aluminium windows with necessary screws etc. complete. |
| 114 | Powder coated minimum thickness 50 micron aluminium. |
| 115 | Providing and fixing aluminium pull bolt lock anodised ISI marked (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 116 | Providing and fixing 3 mm thick aluminium composite panel consisting of 2 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick) of required sizeto Prelaminated Flush door shutter including fixing with require size screw etc. in all complete as per direction of Engineer-in-charge. |
| 117 | Providing and fixing of Hollow metal door at all levels from ISO 9001-2000 certified Manufacturer. All hollow metal general doors with or without vision panel. Pressed Galvanized steel Single /Double leaf to required sizes of approved make . which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. |
| 118 | Door frame shall be Single rebate profile of size 100 x 58 mm Kerb Frame made out of 1.60 mm thick galvanized steel sheet (16 gauge). Frames should be Mitered and field assembled with self tabs. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement slurry if recommended on the clear masonry opening. |
| 119 | Door leaf should be 46mm thick fully flush double skin door with or without vision light. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads and reinforcement. The infill material shall be resin bonded honeycomb core. All doors should be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with lock seam. For pair of doors astragals will be provided as required. Vision light wherever applicable should be as per joinery details with a screw on glass beading on the inside. The glass should be 5mm clear toughened glass. Louvers when recommended should be sight proof and shall be flush fixed on the external surface. |
| 120 | All doors and frames shall be finished with polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt sprey test. Rate should include supply and installation of door and hardware set as mentioned in the door and hardware schedule.Single leaf door hardwareSS Ball Bearing But Hinges 4\\"X 3\\"X3MM = 3 NoMortice Deadlock = 1 No Cylinder 5 Pin L-70mm Both Side Keys = 1NoSS 304 Grade Pull Handle 25mm Dia Length 300mm = 2 No Door Closer = 1 NODouble leaf door hardwareSS Ball Bearing But Hinges 4\\"X 3\\"X3MM = 8 NoMortice Deadlock = 1 No Cylinder 5 Pin L-70mm Both Side Keys = 1NoSS 304 Grade Pull Handle 25mm Dia Length 300mm = 4 No Ryobi concealed flush bolt body RB 10 Rod for Ryobi concealed flush bolt body RB 10 length 570 mm = 1NoDoor Closer = 2 NO |
| 121 | Upto 3.0 m height |
| 122 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiberglass from all sides. M.S. stay shall be provided at the bottom to steady the frame. ( Make :- Nyflex ,Rathi panels Pvt Ltd ,Saify Fiber glass works or equivalent) |
| 123 | Providing and fixing to existing door frames. |
| 124 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS: 14856 - 2000 including fixing to frames. |
| 125 | Providing and fixing of side hings or siliding , 40 mm thick Kiln seasoned and chemically treated hollock wood plain lining tongued and grooved panneled door fabricated out of hollow M.S. box section frame work and panneled made out 40 mm thick Kiln seasoned and chemically treated hollock wood. All the frame work of the door will be painted with two coats of epoxy.Zinc phosphate primer and finish paint on exposed surface shall be 2 or more coats in polyurethane aliphatic grade. All hardware,rollers,hinge etc shall be fabricated out of high grade steel with prior approval of Engineer-In-Charge. Before fabrication contractor are required to submit the shop drawings and take approval from Engineer-In-Charge. |
| 126 | Frame work without sheeting including all hardware . |
| 127 | Providing and fixing 40 mm thick Kiln seasoned and chemically treated hollock wood plain lining tongued and grooved, including wooden plugs complete with necessary screws. |
| 128 | Providing & fixing mechanism for top hung sliding doors consist of roller with bracket,base plate,pins,washer spacer for bottom trolley and as per direction of engineer in charge. (cost for 2 roller & 2 bottom trolly in one set) |
| 129 | Supply & installation of motorized / electrical operation system for motorized Door using 1.5 kw , 3 phase shutter motor having torque 350 NM with built in reduction gear box / limit switch for operate of door etc all complete or . suitable as directed by engineer in charge. suitable complete (make Eltro,German or equivalent) |
| 130 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.. |
| 131 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works such as plate steel door with frame including steel stiffener plate and built up sections |
| 132 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 133 | CHAPTER - V FLOORING |
| 134 | Cement plaster skirting (upto 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. |
| 135 | 18 mm thick |
| 136 | Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. |
| 137 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and polished machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 Cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment. epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all level. |
| 138 | Granite stone slab of colour black, Cherry/Ruby red |
| 139 | Area of slab over 0.50sqm |
| 140 | Providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 141 | Granite work |
| 142 | Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with expoxy resin based adhesive including cleaning etc. complete. |
| 143 | Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete |
| 144 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 145 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 146 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 147 | Double charge vitrified tile polished finish of size |
| 148 | Size of Tile 600x600 mm |
| 149 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 150 | Size of Tile 600x600 mm |
| 151 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. including Cutting groove of size 8 mm x 40 mm (depth) in the hardened concrete immediately after curing peroid is over by using diamond cutter and filling the grooves with polysulphide compound etc. all complete as per the direction of Engineer-in-charge.Cement content considered in this item is @ 330 kg/cum.NOTE : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either redesign the mix or bear the cost of extra cement . |
| 152 | Epoxy Antistatic Conductive flooring system- 2mm thick (Fosroc Nitoprime 25 + self adhesive copper tape + conductive undercoat + 2mm antistatic Conductive floor topping using Nitoflor SL conductive. or equivalent.Surface Preparation: Surface preparation shall be conducted using a vacuum-assisted high-speed electric grinding machine to eliminate all cement laitance, friable concrete, and loose mortar. Any areas of the floor contaminated by grease, oil, solvents, etc., shall be cleaned before preparation begins. Cracks and cold joints, if present, will be opened using a groove cutter machine or manually prepared as per site requirements.Antistatic Flooring (100µ thick Copper tape + Conductive undercoat + 2mm Nitoflor SL conductive flooring) . or equivalent. Earthing connections must be done properly as per the design. Priming- Provide and apply a two-component epoxy-based primer, NITOPRIME 25, for improved adhesion and corrosion protection on the acceptable substrate at 5.5 - 6.5 sqm/litre to form a WFT of 130 microns. Allow the primer to air cure for 24 hours before starting the floor coating treatment. |
| 153 | It must be tack-free. Install 100 µ thick, 25mm wide self-adhesive copper tape in a symmetric grid pattern at a distance of 10m center-to-center. This should be well-connected to an earthing pit (an earthing pit should be made at least every 300 sqm). Supply and apply NITOFLOR SL CONDUCTIVE UNDERCOAT @ 4 sqm/litre over the entire area, including copper tapes, without creating puddles of material. Allow the undercoat to cure completely until it is tack-free before the final topcoat application. The surface resistance for the undercoat shall be 2x10^3 - 4x10^3 ohms. PProvide and apply a 2mm thick, four-component self-leveling NITOFLOOR SL Conductive TOPCOAT at 7.5 sqm/15 litres using a serrated trowel. The surface resistivity should be 25 x 10^3 to 1 x 10^6 ohms for conductive flooring, as per ASTM F150. Nitoflor SL Conductive/Dissipative Flooring shall have the following typical properties:Tensile Strength : 11.5 Mpa as per BS 6319 part 7Compressive Strength : 60 N/mm^2 as per ASTM C579Flexure strength : >20 N/mm^2 as per BS 6319 part 3Pull off adhesion : >2 Mpa as per ASTM D4541Specific gravity : 1.7 approx |
| 154 | Wall to Floor Epoxy Coving - 75mm x 75mm- Coving treatment shall be done with Nitoflor TF5000 from Fosroc Chemicals India Pvt Ltd or an equivalent product. Nitoflor FC150 of the desired shade shall be used as the top coating over the Nitoflor TF5000 epoxy coving mortar. |
| 155 | CHAPTER - VI ROOFING |
| 156 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
| 157 | Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
| 158 | Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 159 | After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. |
| 160 | Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 161 | The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 162 | With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 163 | Raft/Bottom: Supply and apply a 1.5 mm thick, prefabricated, pre-applied, fully bonded, weldable HDPE waterproofing membrane that forms an integral bond with the poured concrete, designed using Laplock™ technology. The membrane shall be a multi-layer composite waterproofing system comprising a layer of virgin HDPE film, pressure sensitive adhesive and a weather resistant protective and trafficable layer. The system shall comply with IS 16471:2017 and BS 8102:2022, exhibit excellent chemical resistance, and protect the structure against salt and sulphate attack. It shall possess high puncture resistance, eliminating the need for a protection screed, thereby allowing reinforcement steel placement directly over the membrane.The fully bonded HDPE membrane shall create an intimate bond with the underside of the poured concrete, effectively preventing lateral water migration. The membrane shall be 20m length and 2.4m width with minimum 100mm wide factory made adhesive free weldable sidelap and endlaps with laplock™ technology. The product shall be manufactured in India by the original manufacturer from a CE-certified plant. The membrane must be supplied with an original Manufacturer’s Test Certificate (MTC) and installed strictly in accordance with the manufacturer’s guidelines. The membrane shall be applied loosely over the PCC, and side and end laps shall be welded using a twinny welding machine. |
| 164 | The fully bonded waterproofing membrane HDPE PW1.5 shall have following typical properties:1) Membrane thickness: 1.5mm (ASTM D 3767)2) Tensile strength (film): 26 Mpa (ASTM D412)3) Elongation: 600% (ASTM D412)4) Peel adhesion to concrete: 1200N/m (ASTM D 903)5) Puncture Resistance: 900N (ASTM E154)6) Lap joint strength (welded): 12000 N/m (ASTM D 6392)7) Resistance to hydrostatic pressure: >71m (ASTM D 5385)8) Low temperature flexibility: <-25°C, Pass (ASTM D1970)The item rate shall include base preparation which include wire- brushing the Concrete/Masonry surface & cleaning with air jet, treating all joints, cracks, honeycombs on the RCC members as per manufactures specification and approved methodology. Item rate also includes cost of all materials, miscellaneous consumables, labors, tranportation of material to all required locations by approved means, tools, plant and machinery, and all other incidental charges etc.,NOTE: The system does not require any screed protection and reinforcement can be laid directly on the membrane. |
| 165 | Vertical Wall: Provide and apply two coats of Nitoproof 630 PU, a single-component, pitch-free, PU-based, cold-applied, seamless elastomeric waterproofing membrane, over the primed surface with Nitoproof WB primer. The application shall be at a coverage rate of 1.25 kg/m² per coat, achieving a Dry Film Thickness (DFT) of 1.5 mm. The membrane will cure by reacting with atmospheric moisture to form a tough, elastomeric waterproof layer.It shall exhibit below mentioned properties:Thickness (DFT): 1.5 mmSolids Content: ≥85%Service temperature: -40°C to 70°CTensile Strength: ≥4 MPa±10% (ASTM D412)Elongation: >500% (ASTM D412)Adhesion in-peel test: >50N (ASTM C836)Recovery from elongation: 95% (ASTM D412)Initial hardness (Shore A): 70 (ASTM 2240)Water permeability@ 5 bar: Nil (BSEN 12390)Crack bridging: > 2mm (ASTM C836-95)The system includes thorough surface preparation, cleaning, brushing, and removal of flaky materials, grouting porous areas with cementitious grout.Protection Board: Providing and applying CE marked protection dimple board made of HDPE sheet 8mm dimple height of approved equivalent make, as a protection for waterproofing membrane on the retaining wall spot fixed with double sided adhesive tape or with the help of mechanically fastened metal strip to the top of the substrate as per manufacturer’s specification or as per the instruction of Engineer-in-charge |
| 166 | Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : |
| 167 | Serrated with central bulb (225 mm wide, 8-11 mm thick) |
| 168 | Providing and fixing uPVC pipe 6 Kg/cm2 (IS:4985-2000) including injection moulded fittings wherever required e.g., tees, bends of any degree, clamps, couplings, adapters, plugs, unions etc. and jointing with solvent cement including cutting and making good the floors and walls wherever required etc. all complete. (For Rain water pipe). |
| 169 | 160 mm diameter |
| 170 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 20 cm x 20cm and weighing not less than 995 grams. |
| 171 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 172 | Hot finished welded type tubes |
| 173 | Providing and fixing M.S. round holding down bolts with nuts and washer plates complete. |
| 174 | Providing and fixing bolts including nuts and washers complete. |
| 175 | Supplying and fixing of precoated Zincalume/Galvalume sheet roofing of 0.5mm TCT -AZ-150, 550 mpa (Alumunium Zinc Alloy couting of 150 gms, per sqm total on both sides) as per AS: 1397 in cover width of 1000-1020 mm, (size, shape and pitch of corrugation as approved by Engineer-in-charge).The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap.The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT), Hi-strength steel with min. 550 MPa yield strength.The raw material shall be of Tata BlueScope , Jindal or equivalent The steel sheet shall be fastened with 25 μm zinc-tin alloy coated, Hex head, self-drilling screw as per AS 3566-2002 Class 3 fasteners of approved make with EPDM washer as per the requirement considering the profile shape and design load.Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportaion and should be suppplied in single length upto 12meter or as directed by Engineer-in-charge. |
| 176 | Supply & fixing of Roof flashing and trims (parapet flashing, transition trims, expansion joint trims and ridge caps) manufactured from same material as roof panels, fixed as per manufacturer recommendation flashing girth up to 600mm. |
| 177 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm widex 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.l. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.l. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.l. wire at every junction, |
| 178 | including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 179 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 180 | CHAPTER - VII FINISHING |
| 181 | Providing and laying 12 mm cement plaster of mix : |
| 182 | 1:6 (1 cement : 6 fine sand) |
| 183 | Providing and laying 15 mm cement plaster on the rough side of single or half brick wall of mix |
| 184 | 1:6 (1 cement : 6 fine sand) |
| 185 | Providing and laying Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement |
| 186 | 20mm cement plaster |
| 187 | Providing and laying 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. |
| 188 | Providing and laying 6mm cement plaster of mix: |
| 189 | 1:3 (1 cement : 3 fine sand) |
| 190 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers: |
| 191 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 192 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 193 | Providing and applying two coats of fire retardant paint on cleaned wood / ply & plaster surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. |
| 194 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 195 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: |
| 196 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 197 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 198 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
| 199 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 200 | Two or more coats on new work |
| 201 | Providing & fixing chicken wire mesh at the junctions of RCC and brick work, 100mm overlapping on both sides with all necessary hardware etc., complete. |
| 202 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 203 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections |
| 204 | CHAPTER - VIII SANITARY INSTALLATIONS |
| 205 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand / make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 liter with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 206 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 207 | White Vitreous China Flat back wash basin size 630x 450 mm with a single of 15 mm C.P. brass pillar taps. |
| 208 | Providing & fixing urinal partition of 12 mm th toughened glass (size 675 x 330 mm) complete with ss brackets, bolts nuts for fixing on wall complete in all respects. |
| 209 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 210 | Providing and fixing 100mm CP brass grating for trap. |
| 211 | Providing and fixing 5mm thk beveled edge mirror of superior glass (of approved quality) fixed with teak wood beading size 50x20mm with french spirit polish, 6mm thick water proof ply wood on back of the mirror complete with two or more coats of black bitumeneous paint at the back of ply. |
| 212 | Providing & fixing in position CP soap dish.(Jaquar model no. 1131N/approved equivalent). |
| 213 | Providing & fixing in position C.P. brass towel rail (600mm long) including cutting necessary C.P. brass screws complete. |
| 214 | Providing and fixing toilet paper holder |
| 215 | C.P. brass |
| 216 | Providing & fixing Hand Shower (Health Faucet) with 8mm dia, 1M long PVC tube and wall hook. (Jaquar model no. ALD-565 /approved equivalent). |
| 217 | Providing & fixing in position C.P. brass twin coat hook including cutting necessary C.P. brass screws complete.(Jaquar model no. 1191N/approved equivalent). |
| 218 | Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. |
| 219 | The Pipes will be supported with threaded G I rods & clamps on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. |
| 220 | 100 mm diameter |
| 221 | Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. |
| 222 | 40mm outer dia |
| 223 | 50mm outer dia |
| 224 | Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince). |
| 225 | a) 100 mm inlet and 100 mm outlet. |
| 226 | ( with 127dia Glossy CP Grating Jayna |
| 227 | model no.RRB 127) |
| 228 | Providing & fixing 110m x 50mm waste with PVC reducer including cutting chases in floor, cutting RCC slab complete as required. |
| 229 | Supply of self contained drinking water cooler with refrigerator R 22 , cooling capacity 40 liter / hour storage capacity 40 liter , rate of maximum energy consumption in watt 575 along with water purifier ete complete . |
| 230 | Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 231 | Providing and fixing PTMT 15mm urinal spreader size 95x69x100mm with 1/2 inch BSP thread and shapes,weighing not less than 60 gms. |
| 232 | Providing and fixing C.P.brass extension nipple(size 15mmx50mm) of approved make and quality as per direction of Engineer-in -charge. |
| 233 | Providing and fixing C.P.brass Single lever telephonic wall mixer of approved quality & make as approved by Engineer-in-charge. |
| 234 | 15 mm nominal bore. |
| 235 | Providing and fixing CP shower rose with 15 or 20mm inlet |
| 236 | 100mm diameter |
| 237 | Providing in position storage type hot water electrical geyser( vertical or horizontal-1.5 kw) including making connection in all respects.25 litres capacity. |
| 238 | CHAPTER IX - WATER SUPPLY |
| 239 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 240 | Internal work – Exposed on wall |
| 241 | 20 mm nominal dia Pipes |
| 242 | 25 mm nominal dia Pipes |
| 243 | 32 mm nominal dia Pipes |
| 244 | 40 mm nominal dia Pipes |
| 245 | 50 mm nominal dia Pipes |
| 246 | PrProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 247 | Concealed work, including cutting chases and making good the walls etc. |
| 248 | 20 mm nominal dia Pipes |
| 249 | 25 mm nominal dia Pipes |
| 250 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 251 | External work |
| 252 | 20 mm dia nominal bore |
| 253 | 25 mm dia nominal bore |
| 254 | 40 mm dia nominal bore |
| 255 | 100 mm dia nominal bore |
| 256 | Making connection of GI distribution branch with GI main of following sizes by providing and fixing tee,including cutting and threading the pipes etc, complete. |
| 257 | 25 to 40mm nominal bore |
| 258 | Providing and fixing brass stop cock of approved quality. |
| 259 | 15 mm nominal bore |
| 260 | 20 mm nominal bore |
| 261 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end ) |
| 262 | 25 mm nominal bore |
| 263 | Providing and fixing cPVC ball valve of approved quality in CPVC pipe line etc. complete wherever necessary and as directed by the Engineer-in-charge. |
| 264 | 25 mm nominal bore |
| 265 | 32 mm diameter pipe. |
| 266 | 40 mm diameter pipe. |
| 267 | 50 mm diameter pipe. |
| 268 | Providing and fixing uplasticised PVC connection pipe with brass unions |
| 269 | 45 cm length |
| 270 | 15 mm nominal bore |
| 271 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
| 272 | 15 mm nominal bore (Jaquar Cat No. - CON - 037KN, Kingston or equivalent) |
| 273 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 274 | 15 mm nominal bore (Jaquar Cat No. - CON - 107KN, Kingston or equivalent ) |
| 275 | Providing and fixing C.P. brass angle valve for basin mixer and geyser point of Jaguar make (CLARION Cat No. CQT-23053 /Equivalent) conforming to IS :8931 |
| 276 | 15 mm nomunal bore : |
| 277 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 Cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside palstering with cement mortar 1:3 (1 Cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design: |
| 278 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 279 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for sluice valve, with C. I. surface box 100mm top daimeter,160mm bottom diameter and 180mm deep(inside0 with chained lid and RCC top slab 1:1.5:3 mix (1 Cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 Cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside palstering with cement mortar 1:3 (1 Cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design: |
| 280 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 281 | Providing and fixing CPVC union in CPVC pipe line etc. complete wherever necessary and as directed by the Engineer-in-charge. |
| 282 | For 20 mm nominal outer dia Pipes |
| 283 | For 25 mm nominal outer dia Pipes |
| 284 | For 32 mm nominal outer dia Pipes |
| 285 | For 40 mm nominal outer dia Pipes |
| 286 | For 50 mm nominal outer dia Pipes |
| 287 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 288 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. |
| 289 | 25 mm nominal bore, 152 mm long, weighing not less than 440 gms |
| 290 | CHAPTER - X DRAINAGE |
| 291 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 292 | 100 mm diameter |
| 293 | 150 mm diameter |
| 294 | 250 mm diameter |
| 295 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes /uPVC pipes including bed concrete as per standard design: |
| 296 | 100 mm diameter S.W. pipes /uPVC pipes |
| 297 | 150 mm diameterS.W. pipes /uPVC pipes |
| 298 | 250 mm diameter S.W. pipes /uPVC pipes |
| 299 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: |
| 300 | 150x100 mm size P type |
| 301 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 302 | 180x150 mm size P type |
| 303 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 304 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregrate 40mm nominal size ) inside plastering 12 mm thick with cement mortar 1:3 (1 Cement : 3 coarse sand) finished with floating coat of neat cement & making channels in cement concrete 1:2:4 mix (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: |
| 305 | Inside size 90x80cm and 45cm deep including C.I. cover with frame (light duty) 455x610mm internal dimensions total weight of cover and frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg) |
| 306 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 307 | Inside size 120x90cm and 90cm deep including C.I. cover with frame (medium duty) 500mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) |
| 308 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 309 | Extra for depth for manholes |
| 310 | Size 90x80 cm |
| 311 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 312 | Size 120x90cm |
| 313 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
| 314 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263mm and width as 165mm with minimum 112 mm space between protruded legs having 2mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistant test as per specification and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manhole with 30x20x15 cm cement concrete block 1:3:6 (1cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design |
| 315 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) including 500x450mm precast R.C.C. horizontal grating with frame complete as per standard design: |
| 316 | With common burnt clay F.P.S. bricks(non modular) of class designation 7.5 |
| 317 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) with precast R.C.C. vertical grating complete as per standard design: |
| 318 | With common burnt clay F.P.S. bricks(non modular) of class designation 7.5 |
| 319 | Making soakpit 2.5m diameter 3.0meter deep with 45x45xcm dry brick honey comb shaft with brick of class desiganation 35 and SW drain pipe 100mm diameter,1.8m long complete as per standrd design with F.P.S bricks including filling back ballast of 50-80mm broken brick bats all around the honey comb shaft including finishing of 75mm thk precast concrete cover(1:2:4) and fixing of CI frame work with grating of size 455x610mm and wt of cover not less than 230KG. |
| 320 | Supply,lowering and installation of RCC ready made hume pipe 50 users capacity septic tank of approved make at suitable location as directed including providing CI 100 mm dia ventilating shaft of 1.8m length and cowl at top,sewer line connnections at inleet and outlet , excavation, back filling, etc complete as per standard design and as directed. |
| 321 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidated each deposited layer by ramming, watering, etc. and disposing of surplus excavated soils directed, within a lead of 50m. |
| 322 | All kinds of soil |
| 323 | Pipes, cables etc. exceeding 80mm dia. but not exceeding 300 mm dia. |
| 324 | CHAPTER - XI EOT CRANE |
| 325 | Design, Manufacturing, Supplying, Erection, Testing & commissioning of double girder, Crab type Flameproof EOT crane with VVVF Drives and inching facilities as per the specifications given in Annexure-I and conforming to the standards given in IS: 3177, 807 & 2148 and other relevant IS standards of the latest revisions as shown below complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required. |
| 326 | 100 Ton capacity Double Girder Crab type Flameproof EOT Crane complete with Creep Drive complete with long travel and cross travel movements as per technical specifications and fully in compliance with technical specification and as per IS: 807, 3177 & 2148 and other relevant IS standards of the latest revisions. Span: 14.30 m, Lift: 14.0 m, Bay length: 40.0 m |
| 327 | Provinding & fixing Motorized Chain Pulley Block, Capacity: 5 tonCapacity : 5 tonUsage/Application : Single Grinder CraneStandard Lift : 6 m |
| 328 | Design, Manufacturing, Supplying, Erection, Testing & commissioning of material for Festoon type of current collection system complete with support tracks, cable loops, cable trolley, junction box and cable from switch to crane festoon with all necessary fixtures.. |
| 329 | Design, Manufacturing, Supplying, Erection, Testing & commissioning of material for Gantry Rails section 90 Lb. of prime material in length of 10m and above complete with mounting arrangement. |
| 330 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 331 | CHAPTER - XII Road & Hardstanding |
| 332 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (No additional lift payment will be given for mechanical excavations) |
| 333 | All kinds of soil |
| 334 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 335 | Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift: |
| 336 | All kinds of soil |
| 337 | Supply of approved Moorum obtained from approved quarry outside MOD land filling in layers not exceeding 200mm in thickness including dressing and leveling, watering, compacting etc., complete as directed and standard specifications and compacting each layer with 8-10 Tonne road roller etc. all complete. |
| 338 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 339 | With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 340 | Construction of dry lean cement concrete sub base over a prepared sub¬grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge. |
| 341 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, |
| 342 | making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer¬in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. |
| 343 | Cement concrete prepared with batch mixing machine |
| 344 | Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) |
| 345 | Providing and laying in position polysulphide sealing compound for expansion joints etc. |
| 346 | Providing & placing PVC Pipes (40 mm dia ) on road Expansion joint as Expansion cap around Dowel bars , as per approved drawing as directed by Engineer in charge . |
| 347 | Providing and laying Polythene sheet (125 micron thick) confirming to IS :2508 antifriction layer on the sub base course complete as per specifications. (Overlaps atjoints of pvc sheet should be 150 mm wide) |
| 348 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with tiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete |
| 349 | 450 mm dia RCC pipes. |
| 350 | 600 mm dia RCC pipes. |
| 351 | 900 mm dia RCC pipes. |
| 352 | Providing excluding level: and laying in position cement concrete of specified grade the cost excluding of centering and shuttering - All work up to plinth level: |
| 353 | 1:5:10 (1 cement: 5 coarse sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources |
| 354 | 1:4:8 (1 Cement : 4 coarse sand derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 355 | 1:3:6 (1 Cement : 3 coarse sand derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 356 | 1:2:4 (1 cement : 2 coarse sand derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 357 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
| 358 | CHAPTER - XIII Traverse Wall |
| 359 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m; disposed earth to be levelled and neatly dressed. (No additional lift payment will be given for mechanical excavations) |
| 360 | All kinds of soil |
| 361 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.(No additional lift payment will be given for mechanical excavations) |
| 362 | Ordinary rock |
| 363 | Hard rock (blasting prohibited) |
| 364 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (5% voids to be deducted) |
| 365 | Supply and filling of approved earth (Including royalty) obtained from outside MD land for formation of sub base including spreading in layers not exceeding 200mm in thick,necessary watering,consolidation to the required level,gradient and camber with 8-10 Tonne road roller to achieve minimum of 95% proctor density including cost of excavation all as per specifications and drawings at all lead and lift and as directed by the Engineer.(Payment shall be made for consolidated quantity after deduction of 5% for voids.) |
| 366 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level |
| 367 | 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 368 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 369 | Foundations, footings, bases of columns etc. for mass concrete. |
| 370 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 371 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all height & level.. |
| 372 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 373 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 374 | All works upto plinth level |
| 375 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 376 | All works above plinth level upto floor V level |
| 377 | All works above plinth level upto floor V level |
| 378 | Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement |
| 379 | 20mm cement plaster |
| 380 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers: |
| 381 | Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including unplasticised - PVC moulded fittings/accessoriesto IS : 13592 Type jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. Inclusive of all fittings |
| 382 | 75 mm diameter |
| 383 | 6mm cement plaster of mix: |
| 384 | 1:3 (1 cement : 3 fine sand) |
| 385 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: : |
| 386 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 387 | Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officerin charge |
| 388 | Providing & laying in position filler media consisting of pebbles (75 mm and down), pea gravels, Moorum etc. as per instruction of site Engineer near weep holes. |
| 389 | CHAPTER - XIV Area Devlopment |
| 390 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (No additional lift payment will be given for mechanical excavations) |
| 391 | All kinds of soil |
| 392 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (5% voids to be deducted) |
| 393 | Providing and laying in position cement concrete of specified grade the excluding cost of centering and shuttering - All work up to plinth level: |
| 394 | 1:4:8 (1 Cement : 4 coarse sand derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 395 | 1:2:4 (1 cement : 2 coarse sand derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 396 | Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with : |
| 397 | Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 398 | Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement |
| 399 | 20mm cement plaster |
| 400 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers: |
| 401 | Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) |
| 402 | Flush/ Ruled pointing |
| 403 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.. |
| 404 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works such as plate steel door with frame including steel stiffener plate and built up sections |
| 405 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge. |
| 406 | Made of G.I. wire of dia 4 mm |
| 407 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 408 | Two or more coats on new work |
| 409 | CHAPTER - XV FIRE FIGHTING |
| 410 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. |
| 411 | 150mm dia |
| 412 | Providing, laying, testing & commissioning of 'C'class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittingslike elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with twoor more coats of synthetic enamel paint of required shade complete as required : |
| 413 | 25 mm dia |
| 414 | 32 mm dia |
| 415 | 40 mm dia |
| 416 | 50 mm dia |
| 417 | 65 mm dia |
| 418 | 80 mm dia |
| 419 | Supplying and fixing single headed external yard hydrant valve with 1 nos 63mm dia instantaneous FM Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 ( Type-A) with blank Gunmetal/Stainless steel Cap and chain as required: |
| 420 | Single headed Gunmetal |
| 421 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 422 | 50 mm dia |
| 423 | 65 mm dia |
| 424 | 80 mm dia |
| 425 | 150 mm dia |
| 426 | Supplying and fixing 63mm dia, 30 m RRL hose pipe with 63mm dia male and female coupling duly bound with GI wire, riverts etc. conforming to IS 636 (type-A) as required |
| 427 | Gun Metal |
| 428 | Supplying, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (inlet) 25mm NPT male thread to sprinkler head (outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following size complete as required. |
| 429 | 1000mm |
| 430 | 1500mm |
| 431 | Providing, installation, teasting and commissioning of adjustable rosette plate for 15mm dia in white finish UL listed or FM approved complete as required. |
| 432 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: |
| 433 | Pendent Sprinkler |
| 434 | Upright Sprinkler |
| 435 | CHAPTER - XVI : ARBORICULTURE |
| 436 | TREE PLANTATION |
| 437 | Digging holes in ordinary soil and refilling the same with the excavatedearth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts ofstacked volume of earth after reduction by 20% : 1 part of stacked volumeof manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : |
| 438 | Holes 1.2 m dia and 1.2 m deep |
| 439 | Holes 0.90 m dia and 0.90m deep |
| 440 | Providing and stacking of the following well developed,healthy,true to variety/type plants/Trees having minimum height as below mentioned at site work. |
| 441 | Providing and stacking of Bauhinia blakeana (Kachnar) plant of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 442 | Providing and stacking of Cassia siamea plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 443 | Providing and stacking of Peltophorum species plant of height 150-165 cm.in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 444 | Providing and stacking of Ficus benjamina (green) plant of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge. |
| 445 | Providing and displaying of Areca Palm plant , having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. |
| 446 | Providing and displaying of Money Plant Broad Leaves mounted on moss stick 90 cm ht., 3 to 4 plants in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot / Plastic pot . & as per direction of the officer-in-charge. |
| 447 | Providing and displaying of Dracaena song of India specimen plant (three in one), having ht. 60 cm & above, well developed, fresh and healthy with good foliage in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. |
| 448 | Providing and displaying of Araucaria cookie plant, having ht. 60 cm to 75 cm, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 20 cm size of Earthen pot / Plastic pot. & as per direction of the officer-in-charge. |
| 449 | Providing and displaying of Raphes palm having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed, full of fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 450 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water). |
| 451 | Trees Plant |
| 452 | Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. |
| 453 | Complete maintenance of trees, jobs like making of basin at regular interval,application of fertilizer etc, (excluding the cost of material which shall be supplied by the department and other T & P material/articles shall be provided by the contractor) as per direction of officer incharge |
| 454 | Trees for 250 no/(up to 4 & up to 3 year Slow & Fast growing Per tree group) |
| 455 | SHRUB PLANTATION (SOLO) |
| 456 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts ofstacked volume of earth after reduction by 20% : 1 part of stacked volumeof manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost ofmanure, sludge or extra good earth if needed to be paid for separately) : |
| 457 | Holes 60cm dia and 60cm deep |
| 458 | Providing and stacking of the following well developed,healthy,true to variety/type plants having minimum height as below mentioned at site work. |
| 459 | Supply and stacking of plant Hibiscus rosasinensis of height 60-75 cm.with 5-6 branches in p.bag of size 25 cm as per direction of the officer-in-charge. |
| 460 | Providing and stacking of plant Mussaenda rythrophylla (Rosea) of height 60-75 cm. multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge. |
| 461 | Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 90-105 cm.,bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 462 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water). |
| 463 | Shrubs Plant |
| 464 | Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. |
| 465 | Complete maintenance of shrub(out side of lawn area), jobs like making of basin at regular interval i/c watering,weeding,prunning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge. |
| 466 | CHAPTER XVII- INTERNAL ELECTRIFICATION |
| 467 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Frls heavy duty PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 468 | Group B |
| 469 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessedFrls heavy duty PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 470 | Group B |
| 471 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 472 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 473 | S.P 5/6 amps, one way modular switch, ISI Marked |
| 474 | S.P 15/16 amps, one way modular switch, ISI Marked |
| 475 | 5 pin 5/6 amps, modular socket Outlet, ISI Marked |
| 476 | 6 pin 15/16 amps, modular socket Outlet, ISI Marked |
| 477 | Telephone socket outlet |
| 478 | TV socket outlet |
| 479 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 480 | Supply and fixing following size/moules, GI box along with modular base & cover plate for modular switch in recess etc as required |
| 481 | 2module (100mmx75mm) |
| 482 | 3module (100mmx75mm) |
| 483 | 6module (200mmx75mm) |
| 484 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class steel conduit as required. |
| 485 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 486 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 487 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 488 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 489 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 490 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 491 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 492 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 493 | 20 mm |
| 494 | 25 mm |
| 495 | Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (for split AC) |
| 496 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 497 | MCCB, MCB & DB'S |
| 498 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB) |
| 499 | 4 way (4 + 12), Double door |
| 500 | 8 way (4 + 24), Double door |
| 501 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 502 | 8 way (4 + 24), Double door |
| 503 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) |
| 504 | 12 way, Double door |
| 505 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 506 | Single pole |
| 507 | Double pole |
| 508 | Triple pole and neutral |
| 509 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 510 | Supplying and fixing following rating, double pole (single phase and neutral) 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 511 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired |
| 512 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 513 | 160 A, 16 KA MCCB |
| 514 | Providing and fixing M.V./HT danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 515 | LIGHT FIXTURE |
| 516 | Supply, Installation, Testing and Commissioning of following type Energy efficient LED light fixtures complete with LED Control gear/ LED driver suitable to the respective fixture(not less than 100 Lumens /watt) all pre wired upto the terminal block. All fixtures shall be supplied with lamps/Led drivers etc.(Seperate rate for LED Driver is not allowed) complete as required. |
| 517 | 1x34 W LED box type - light fixture including driver, polycarbonated optical cover, housing material steel color white, cool day light etc.compete as directed by engineer incharge. Phillips cat no- BN170C LED40S-6500 PSU L120 |
| 518 | 1x20 W led surface type - light fixture including driver, housing material aluminum color white, cool day light etc.compete as directed by engineer incharge. Phillips cat no- SM296C LED20S-6500 PSU WH |
| 519 | 1x12 W led surface type - light fixture including driver, housing material aluminum color white, cool day light etc.compete as directed by engineer incharge. Phillips cat no- SM296C LED12S-6500 PSU WH |
| 520 | 1x10 W led mirror light fixture including driver, housing material aluminum color white, cool day light etc.compete as directed by engineer incharge. Phillips cat no- BN021 LED10S CW |
| 521 | 1x10 Watt led bulk head light fixture including housing high pressure die cost aluminium with polycorbonate cover , color temperature 6500k etc. complete as directed by engineer incharge. Phillips cat no- WT140W LED7S CW PSU S1 PC |
| 522 | 1x43 W LED recessed type - light fixture including driver, polycarbonated optical cover, housing material steel color white, cool day light etc.compete as directed by engineer incharge. Phillips cat no- RC380B LED42S-6500 G6 L60W60 PSU |
| 523 | Supply and fixing of 200W LED LED Floodlight comes with aluminium PDC housing and toughend glass to ensure IP66. Flood light fixture with integral control gear box and including igniter, holder, lamp etc. all complete as required. Phillips cat no- BVP283 LED240 CW FG SY5WB 200W PSU |
| 524 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor with remote, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 525 | Exhaust Fans |
| 526 | Supply, Installation Testing and Commission of heavy duty Exhaust fans with Metallic blades of following sweep with gravity louvres shutters including all accessories / Installation materials required. |
| 527 | 380mm Sweep |
| 528 | 305mm Sweep |
| 529 | Supply, installation, testing & commissioning of factory made 32/40A DP MCB, 10kA in factory made outdoor and weatherproof enclosure (IP 65) . |
| 530 | Supply, installation, testing & commissioning of factory made 40/63A TPN MCB, 10kA in factory made outdoor and weatherproof enclosure (IP 65). |
| 531 | Supply, installation, testing & commissioning of factory made 40 DP RCBO, 100mA in factory made outdoor and weatherproof enclosure (IP 65). |
| 532 | CHAPTER -XVIII FLP WIRING & FIXTURES |
| 533 | Wiring for Light / Fan / Exhaust fan with 10A controlled withflame proof rotary switch light points with 3 x1.5 sqmm of 1100V grade FRLS XLPE PVC insulated copper armoured cable at wall / ceiling / above false ceiling of weather / flame proof area conforming IS -5572 (part-1) and to IS : 2148/1981 for Group-I, IIA, IIB, including all accessories in LM-6 aluminium alloy such as junction boxes, glands etc complete conforming to degree of protection IS-2147/1962, including the cost of providing terminal box of LM-6 to conforming to the latest IS. |
| 534 | One Lights point controlled by one switch. |
| 535 | Two Lights point controlled by one switch. |
| 536 | Wiring for FLP Fixtures |
| 537 | Supply and Wiring with the following size 1100V grade FRLS XLPE insulated Copper armoured conductor cables with FRLS outer sheath conforming to IS 7098 Part II on wall/ Ceiling including all accessories such as Flame proof junction boxes etc complete. |
| 538 | 3 Core 2.5sq.mm armoured( 2XWY) |
| 539 | 4 Core 6sq.mm armoured( 2XWY) |
| 540 | 4 Core 16sq.mm armoured( 2XWY) |
| 541 | Providing end terminations with Copper lugs, double compression type gland with neoprene gasket using Insulation tape, crimping tool etc complete as required. |
| 542 | 3 Core 2.5sq.mm armoured( 2XWY) |
| 543 | 4 Core 6sq.mm armoured( 2XWY) |
| 544 | 4 Core 16sq.mm armoured( 2XWY) |
| 545 | FLP FIXTURES |
| 546 | Supply and installation of WEATHER PROOF / FLAME PROOF group II A, II B as IS 2148/- IP -55 as per IS 2147/1962 and made of cast aluminium alloy LM 6- and IS --5 powder coating with heat resistant clear toughened glass of borosil make following type fluorescent/CFL fixtures shall be complete with Electronic Ballast, PF improvement capacitor, Control gear box. Bipin Rotor type lamp holder, starter, starter base, all pre wired upto the terminal block. All fixtures shall be supplied with lamps. |
| 547 | 250W FLP Integral type LED Flood Light Fixture with including control gear box(Sudhir : WG/1240) |
| 548 | 2X20W FLP LED fixtures( Sudhir : FF/1275) |
| 549 | Supply, installation, testing & Commissioning of Flameproof Distribution board 12Way VTPN MCB DB with 63A, 4Pole MCB & ELCB as incomer and 36nos 10-20A SP/DP/TP MCBs as outgoings. |
| 550 | Supply, installation, testing & Commissioning of Flameproof Distribution board 12Way SPN MCB DB with 40A, DP MCB & ELCB as incomer and 6nos 10-20A SP MCBs as outgoings. |
| 551 | Supply installation testing and commissioning of following rating FLP socket/ switch units in FLP enclosure installed on angle iron frame work complete with all fixing accessories such as Junction boxes. |
| 552 | 63A Flameproof Socket Flameproof 4P pin (3P+N) sockets with 63A FLP-WP receptacle with MCB & top plug combined in surface mounted box IP-55 (WP) suitable for installation in weather proof location Division as per IS -5572 (part-1) degree of protection as per IS:2147 and area classification as per IS etc. complete as required. (sudhir: SS/214) |
| 553 | 32A Three Phase 500V Grade FLP-WP receptacle with MCB & top plug combined in surface mounted box IP-55 (WP) suitable for installation in weather proof location Division as per IS -5572 (part-1) degree of protection as per IS:2147 and area classification as per IS etc. complete as required(sudhir: SS/2021) |
| 554 | 20A Three Phase 500V Grade FLP-WP receptacle with MCB & top plug combined in surface mounted box IP-55 (WP) suitable for installation in weather proof location Division as per IS -5572 (part-1) degree of protection as per IS:2147 and area classification as per IS etc. complete as required(sudhir: SS/2021) |
| 555 | 16/20A single Phase 250V Grade FLP Socket with switch (sudhir: SS/2021) |
| 556 | 10A FLP Switch(sudhir: RI/105) |
| 557 | Supplying, fixing and commissioning of 750 mm sweep Flameproof air circulator fan, oscillatory type, 3 speed control, heavy duty type as required. |
| 558 | Supplying, fixing and commissioning of 380/400 mm sweep Flameproof exhaust fan, 3 speed control, heavy duty type as required. |
| 559 | CHAPTER -XIX TELEPHONE AND DATA SYSTEM |
| 560 | Supply, Installation, Testing & Commissioning of 15U RACK IT INDUSTRY STANDARD RACK with all Standard Accessories as per technical specification.2 Post 19\\" 42U Closed rack , with copper & fiber cable management accessories& 19”Closed Wall Mount Rack (15U/12U)2 Nos. of 1U power distribution box, with 10 x IEC - C13 sockets & with 32Amp MCBterminating on a IP56 power sockets1 No. Horizontal PDU with 5/15Amp Universal Sockets with 32Amp MCB Front mounting PVC Cable managers/ guide Integral Cable management ducts/ arms (on either side) with coversCantilever Tray x 1 (19\\" / 1U/ 255mm - D) Cable retention bobbins X 5 (both sides) + Window Molding x 6 Cable Hangers (set of 3) x 2 (Right & left side one set each)Bar, Earthing 42U Mounting Hardware (Pack of 10) x 5 IP55 Rated |
| 561 | Supply, Installation, Testing and Commissioning of CAT 6A Cable as per technical specification.The Category 6A/ Class EA UTP SCS shall comply with the following standards-ISO/IEC 11801:2010,EN 50173 Part 1 through Part 5:2010 and 2011,ANSI/TIA-568-C,IEC 60603-7-4,IEEE 802.3 applications-The cable should consist of Eight 23 AWG copper conductors. Copper Clad Aluminium or any other combinations are not allowed,Insertion Loss - 3%,Return Loss - 1.0 db |
| 562 | Supply, Installation, Testing and Commissioning 1 mtr CAT 6A Patch Cord as per technical specification.(RACK END)SCS must support patch cord lengths of 1 meter minimum and equipment cords of 2 meter minimum and The Patch cords shall be available in stranded core construction Cords shall be equipped with 8-pin modular plugs on each end.All cords shall be round, and consist of copper conductors, tightly twisted into individual pairs.Nominal cordage diameter shall not exceed 7.24 mm.Plugs shall be designed with an anti-snag latch to facilitate easy removal during move, add and change processes.The LSZH version must comply with the following Fire Safety standards:Flame Spread:- as per relevant ISO/IEC 60332 standard Acidity:- as per relevant ISO/IEC 60754-2 standard Smoke Density:- as per relevant ISO/IEC 61034 standard 3rd Party verification for performance must be provided.The patch cords will have insertion life of 750 cycles minimum. |
| 563 | Supply, Installation, Testing and Commissioning 2 mtr CAT 6A Patch Cord as per technical specification.(USER END)SCS must support patch cord lengths of 1 meter minimum and equipment cords of 2 meter minimum and The Patch cords shall be available in stranded core construction Cords shall be equipped with 8-pin modular plugs on each end.All cords shall be round, and consist of copper conductors, tightly twisted into individual pairs.Nominal cordage diameter shall not exceed 7.24 mm.Plugs shall be designed with an anti-snag latch to facilitate easy removal during move, add and change processes.The LSZH version must comply with the following Fire Safety standards:Flame Spread:- as per relevant ISO/IEC 60332 standard Acidity:- as per relevant ISO/IEC 60754-2 standard Smoke Density:- as per relevant ISO/IEC 61034 standard 3rd Party verification for performance must be provided.The patch cords will have insertion life of 750 cycles minimum. |
| 564 | Supply, Installation, Testing and Commissioning Patch Panel as per technical specification.The ganged adapter style patch panel will utilise increments of six RJ-45 style jacks in a common moulded component.The ganged adapters shall have RJ45 jack in the front and Insulation Displacement Connector (IDC) at the rear of the module.The panel must be capable of supporting an upgrade to an intelligent system without any interruption to service due to patch cord removal or terminal block re-termination. Termination managers must be provided with the panel. These termination managers provide proper pair positioning, control, and strain relief features to the rear terminationarea of the panel. 3rd Party Verification test certificates shall be provided to show compliance to ISO/IEC 11801 Amendment 2 testing for Cat 6A components. Certificate should be available on third party lab which ensures follow up program. |
| 565 | Supply, Installation, Testing and Commissioning of 24 Port Fully Loaded Fiber LIU as per technical specification.Shall accommodate 4 coupler plates or 4 pigtail cassettes for a total of 48 fiber terminations.The width shall be 19 inches and height of 1U (1.75 inches), with a maximum of 18 inch depth.Shall have splice trays to splice minimum 32 fibers. |
| 566 | Supply, Installation, Testing and Commissioning of Fiber Patch Cord as per technical specification.Length shall be 3/5/10 metersAll patch cords shall conform to EIA/TIA-568C.3 and ISO/IEC-11801Shall be Duplex Multi Mode Fiber Optic Patch Cords OM3 50μShall support network line speeds up to 10 Gbps.Each patch cord shall have a LC connector on both sides or SC LC as per requirementAll patch cords shall be factory terminated and packed.Shall be RoHS CompliantShall be Low-Smoke & Zero-HalogenShall have minimum 20-Year Extended Product Warranty |
| 567 | Supply, Installation, Testing and Commissioning of 6 Core Fiber Cable as per technical specification.Shall be Multimode (OM3), Low Smoke Zero Halogen Riser Distribution Cable, 6/12fiber single-unit.Qualification Standards: ANSI/ICEA S-83-596 and Telcordia GR-409Standards Compliance: TIA-492AAAC (OM3), Multimode FiberFlame Test Method: IEC 60332-1, IEC 60754-2, IEC 61034-2Regulatory Compliance: RoHS 2011/65/EU compliantNo. of Fibers: 6/12Construction Materialsa) Jacket Material: LSZHb) Jacket Color: Aquac) Subunit Type: Gel-free |
| 568 | IPABX System |
| 569 | Supply, Installation, Testing and Commissioning IPABX System as per technical specifications.Processors-Each server shall have a minimum of two (2) Intel E5-2600 series CPUs and supports the Intel E5-2697 v2 2.70 GHz 130 W CPU.Storage-The server should have up to 24 front-accessible,hot-swappable, SAS ,SATA or SSD drives, The Server RAID controller should support the following configurations RAID 0, 1, 5, 6, 10, 50,and 60, Should support a write cache of 1 GB for the storage controller, Support for a battery back write cache for the storage controller, Must have an internal slot for SD card / Flash which supports booting hypervisors.Memory-Should have at least 24 DIMM slots for up to 768 GB of DDR3 memory using 32 GB DIMMs, Support for advanced memory redundant technologies like Advanced error-correcting code(ECC) and memory mirroring.Network-Should have 2 * 1 GbE LAN on Motherboard (LOM ) for network connectivity, The server should support the technology of 10-Gbps unified network fabric which aggregates both the Ethernet and FC connectivity on a single controller using Low-latency, lossless, 10-Gbps Ethernet and industry-standard Fiber Channel over Ethernet (FCoE) fabric. |
| 570 | Supply, fixing, testing & commissioning of Type 1 IP Based Telephone as per technical specifications.The phone should support at least 1 line.It should support the following codec G.711a/μ, G.729aIt should have graphical display with a minimum resolution of 128 x 32 pixelsThe phone should support QoS mechanism through 802.1p/q.Should have built-in high-quality full-duplex speakerphoneShould include audio controls for the full-duplex speakerphone and handset.IP address Assignment by DHCP or statically configuredThe Phone should support the ability to provide different ringtones for internal and external calls.Should have volume control button for easy decibel-level adjustments for the speakerphone, handset and ringer.The phone should support mounting against a wallThe phone should support IPv4 and IPv6 from day one. |
| 571 | Supply, fixing, testing & commissioning of Type 2 IP Based Telephone as per technical specifications.The phone should support Power over Ethernet IEEE 802.3af class 1/2/3 and should also have AC poweradapter optionShould feature a LCD display of at least 3.5” for information such as calling party name, calling party number, and digits dialed to be displayed.The phone should have two Ethernet ports of at least 10/100/1000 BASE-T Ethernet ports, one for theLAN connection and the other for connecting to PC/laptop.Corporate directory and Lightweight Directory Access Protocol (LDAP) integration.Ready access to missed, received or placed calls (plus intercom history and directories).The phone should support QoS mechanism through 802.1p/q.IP address Assignment by DHCP or statically configuredHands-free operation with full-duplex speaker-phoneThe phone should be a SIP based Phone i.e. session Initiation protocol (SIP) supportedThe phone should support XML based services and applications. |
| 572 | CHAPTER -XX CABLE TRAY |
| 573 | Supply and fixing of following size hot dip GI perforated/ ladder cable trays made out of 2mm thick hot dip GI sheet (Avg. 65 Microns) and the tray covered with 2mm thick hot deep galvanized GI cover (120 Gsm) excluding hot dip GI structural supports but including anchor fasteners/ nut- bolts/ hardware materials for fixing the cable trays in RCC cable duct/ on metal structure etc., complete as required. all accessories like bend , coupler jointing etc. are included. no extra for any type of accessries except structure . The cable tray is used for outdoor pupose.(structural MS/ GI members are included in civil works). Factory inspection for cable trays and third party lab certification are required for approval before dispatch to site. All installation should be done as per engineer inchage. |
| 574 | 150mm wide x 50mm deep, perforated type with 2mm thick cover |
| 575 | 300mm wide x 50mm deep, perforated type with 2mm thick cover |
| 576 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 577 | 150mm dia |
| 578 | 300mm dia |
| 579 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 580 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 581 | Constructing masonry Chamber 90 x 90 x 90 cm, inside with 75 class designation work in cement mortar 1:4 ( 1 cement : 4 coarse sand ) for sluice valve, with C.I. space box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement \\" 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design: |
| 582 | CHAPTER -XXI SPECIAL EARTHING |
| 583 | Note : All Maintenance free earthing should be UL Listed and All Strip joint should be with UL LISTED Exothermice WELD POWDER . Nut bolt jointing are not accepted |
| 584 | Supply Installation testing & commitioning of Electrolytec Grade Copper Earthing system with 10 ft long , 63 mm dia & 2 mm wall thickness (Pipe-In-Pipe with Flat Terminal ) Tecnology. with 2 Bag of Teksai Ultra High Conductive & Anti Corrosive Compound,Eco frindly. Spec :3 mtr Length x 63 mm dia/ 1.6 mm thick. Terminal size should be 40 x 6 mm thick With - CPRI ,ROHS, SPECTRO & NABL test certificate. |
| 585 | Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid on the wall with necessary interconnections with earth station and equipments. |
| 586 | 25 X 5mm Copper strip (Insulator of size 75 x 75 x 35 mm at an interval of 600 mm) Insulated Supports All Strip joint should be with UL LISTED Exothermice WELD POWDER . |
| 587 | 25 X 5mm Copper strip laid in ground with exavation and refilling . All Strip joint should be with UL LISTED Exothermice WELD POWDER . |
| 588 | Supply and fixing of Static Discharge Handles made out of 20mm dia & 600mm length Copper rod fixed on wall with brass spacers and connected to 25x3mm copper strip. |
| 589 | Supply, Installation, Testing and Commissioning of static discharge meter fix on wall with connection of 25x3 mm cu strip and 2 nos earthing |
| 590 | Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/cable as required. |
| 591 | CHAPTER -XXII LIGHTNING PROTECTION SYSTEM |
| 592 | TERRACE AIR TERMINATION AND MESH SYTEM |
| 593 | Make- ERICO , ALLTEC,GLOBETEK |
| 594 | Supply ,Installation & Testing of multi spike air terminals of 25 mm dia. CU pipe 1000 mm length witg CU sphere on top with 5 nos of 6mm CU spike fitted with threading arrangemnt to CU sphere including suitable moutung arrangement as required and as per site conditions. The air terminal shall be manufactured as per IEC 62561-2. |
| 595 | Supply ,Installation & Testingof 8 mm dia aluminium round conductor for air termination network at parapet and for making mesh at terrace level and shall meet the requirement of IEC 62561-2. |
| 596 | Supply ,Installation & Testing of Parapet Conductor holder for holding of 8 mm dia. round conductor (for RCC roof). The conductor holder shall be mounted on plastic base support and shall meet the requirements of IEC 62561-4.It should be installed at every 1 mtr. . |
| 597 | Supply ,Installation & Testing of Universal Connector for making straight, Tee & Cross joint of 8 mm Aluminium Conductor to 8 mm dia Aluminium conductor on parapet wall, roof and vertical facade of masonery / glass / metallic work. |
| 598 | Supply ,Installation & Testing of Cross Connector for making Cross joint of 8 mm Aluminium Conductor to 8 mm dia Aluminium conductor on parapet wall, roof and vertical facade of masonery / glass / metallic work. |
| 599 | Supply ,Installation & Testing of Expansion piece made of 8mm dia. Aluminium & as per IEC 62561-2 along with suitable connecting accessory. It shall be installed at every 20 mtr to maintain the flexibility to the conductor due to heat. |
| 600 | DOWN CONDUCTOR SYSTEM |
| 601 | Supply ,Installation & Testing of 8 mm dia aluminium round conductor for Down conductors to be installed on vertical wall, façade of masonary /glass /metalic work.It shall meet the requirements of IEC62561-2 |
| 602 | Supply ,Installation & Testing of Parapet Conductor holder for holding of 8 mm dia. round conductor (for RCC roof). The conductor holder shall be mounted on plastic base support and shall meet the requirements of IEC 62561-4.It should be installed at every 1 mtr. . |
| 603 | Supply of Lightning Strike counter LSC 7D for counting the number of lightning strikes without any power supply. The Counter should be mounted on the Down Conductor. The Lightning Counter should be IP 68 rated enclosure suitable for external application. |
| 604 | Supply ,Installation & Testing of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value which shall be of Stainless steel and suitable for connecting 8 mm aluminium round conductor to 30x3 GI Strip. It shall meet the requirements of IEC 62561-2. |
| 605 | Supply ,Installation & Testing of 70 sq mm single core multi strand copper insulated cable to be used as downconductor and interconnection of Earthing and as and shall meet the requirements of IEC 62561-4. |
| 606 | EARTHING SYSTEM |
| 607 | Supply ,Installation & Testing of advance chemical gel earthing system for the proper dissipation of fault/ leakage current to the ground and ensure the continuous electrical connectivity and proper functioning to the electrical system. The earth rod shall be of UL listed & CPRI tested 3 meter long 17.2 mm dia 250 microns copper bonded steel rod with the connecting clamp (ss - rod to tape). The UL listed copper bonded rod also should be tested & ceritifed from CPRI for a short circuit current of 25kA or more. The UL listing shall be punched/ engraved on the rod for the physical verification at site. The engravings shall contain the following details-UL Control number, Dimension details of the rod, Product model number & UL certificate reference number as per detailed technical specification attached. To ensure the electrical conductivity, 25 Kgs (per pit) or more resistance grounding minerals per earth pit/ earth rod shall be used along with the copper bonded rod. As per IEEE 80-2013 (Clause 14.5 d), the grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr. The grounding minerals should be ROHS certified to ensure it does not pollute the ground water as per technical specification attached.Make- Alltec, ERICO |
| 608 | Supply ,Installation & Testing of Galvanised Steel Flat 50x6mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 300 mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/ 305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx: 70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding complete etc as reqd. |
| 609 | CHAPTER -XXIII EXTERNAL ELECTRICAL |
| 610 | Supply and fixing PCC route marker at an interval of 100 Mtrs and road junction for LT and HT Cable. |
| 611 | Providing and fixing Carbon-di-oxide type fire extinguishers consisting of seamless M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS:2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. |
| 612 | Capacity 4.5kg |
| 613 | Providing and fixing Carbon-di-oxide type fire extinguishers consisting of seamless M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS:2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges. |
| 614 | Capacity 9 kg |
| 615 | Providing and fixing ABC dry chemical powder type fire extinguishers consisting of welded M.S. Cylindrical body, discharge nozzle, suspension bracket, conforming to IS:15683 finished externally with red enamel paint and fixed to wall brackets complete with internal charges. |
| 616 | Capacity 9 kg |
| 617 | Supply and installation of 9 ltrs Mechanical Foam (AFFF) fire extinguisher gas cartridge type, ISI marked conforming to IS 10204. complete with gas cartridge, delivery hose, squeeze grip release valve, locking arrangement, bracket with two screw and sleeve. |
| 618 | MAIN LT PANEL Type Tested Panel Assembly (TTA) Indoor Type |
| 619 | Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium bus bar (at the rating of 0.8A/Sqmm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel should follow thw IEC: 61439. |
| 620 | For ACB Note : Air circuit breaker built-in self powered micro-processor based releases for O/L,S/C,I/G&E/F of fault breaking capacity 50KA (Ics=Icu=Icw upto 415V manually operated, Inbuilt Shunt Trip indication. fitted with interlocked door, door sealing frame, automatic safety shutters and frame earthing contact, additional min. 6NO + 6NC Auxiliary contacts, the ACBs must be provided with terminal adaptors (Hr Vr), ACB conforming to IEC 60947-1 and complice RoHS as amended up-to-date complete with following accessories for each complete with following accessories for each ACB. Terminals suitable for AR. cable connections on incomer side and bus bar connection at output sides. FOR MCCB microprocessor based release (adjustable O/L & S/C & E/F ) of fault breaking capacity 50KA (Ics=Icu=100%) upto 415V manually operated with extended rotary handle with castle lock for door interlock with Phase spreader & Phase Barriers at both sides.MCCB shall conforming to IS-1397-2 1993 as amended. |
| 621 | The panel shall have Short circuit withstanding capacity of minimum 35KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. |
| 622 | Incoming Air Circuit Breaker from existing TRF/DG. |
| 623 | 1 nos. 800 amps 50ka 4 pole electrically operated manually draw out type air circuit breaker each with following accessories : |
| 624 | Digital energy meter (Schneider – EM6400NG or equivalent) of accuracy class-1, with 3 Nos. 800/400/5-5amps 15VA dual CTs. |
| 625 | CT Operated Multi Functional Meter with RS485 connectivity - 1set |
| 626 | Phase indicating light shall be protected by suitable rating MCB’s. - 3 Sets with emergency push button |
| 627 | Breaker ON / OFF / TRIP indicating lights with control MCB’s. - 1 Set |
| 628 | 24 V DC Shunt trip coil. - 1 Set |
| 629 | Under voltage release. - 1 Set |
| 630 | Auto-manual / test selector / switch - 1 Set |
| 631 | Breaker control switch - 1 Set |
| 632 | IDMT relay- 1 Set with 5P10 Dual CT |
| 633 | Master trip relay- 1 Set with 5P10 Dual CT |
| 634 | APFC relay- 1 Set with Dual CT |
| 635 | Auxiliary contacts required for necessary interlocking of breakers. |
| 636 | Surge protection relay with all required accessories. |
| 637 | Bus Bars |
| 638 | 800 amps TP 100%N Aluminium bus bars with colour coded heat shrinkable insulating sleeves - 1 Set. |
| 639 | Outgoing |
| 640 | All Breaker ON / OFF / TRIP indicating lights with control MCB’s. - 1 Set each |
| 641 | 2 Nos. 630 Amps 4 POLE MP based MCCB and ON/OFF/Trip & shunt trip coil. |
| 642 | 1 Nos. 320 Amps 4 POLE MP based MCCB and ON/OFF/Trip & shunt trip coil. |
| 643 | 3 Nos. 160 Amps 4 POLE MP based MCCB and ON/OFF/Trip & shunt trip coil. |
| 644 | 4 Nos. 100/63 Amps 4 POLE MP based MCCB and ON/OFF/Trip & shunt trip coil. |
| 645 | Notes : |
| 646 | All outgoing feeders shall have suitable range of followings: |
| 647 | Wiring and supply, installation of space heater, Humidistatae and control MCB’s shall be provided all vertical sections. |
| 648 | Suitable danger board shall be provided. |
| 649 | All bus bar section / backside panels shall have hinged type door. |
| 650 | All incoming / outgoing air circuit breakers shall be suitable for minimum 50 kA breaking capacity. |
| 651 | Required clear space of switchgear from bottom is 300 mm |
| 652 | Incomer ACB receiving power from DG panel shall have suitable provision for busduct connection. |
| 653 | Incomer ACB receiving power from transformer shall have suitable provision for Cables connection.. |
| 654 | All Electronic Energy meter shall be pre wired for BMS connection upto central point within the panel with sheilded cable. |
| 655 | All incoming & outgoing should interlocking and feeders shall have minimum 4 nos. potential free contacts . |
| 656 | Require two spare Cubical for future |
| 657 | Total Panel shall be provided with gas suppression system and all incoming and ougoing require on off trip LED indication. |
| 658 | LT CABLES |
| 659 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 660 | Upto 35 sq. mm |
| 661 | Above 35 sq. mm and upto 95 sq. mm |
| 662 | Above 95 sq. mm and upto 185 sq. mm |
| 663 | Above 185 sq. mm and upto 400 sq. mm |
| 664 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 665 | Upto 35 sq. mm |
| 666 | Above 35 sq. mm and upto 95 sq. mm |
| 667 | Above 95 sq. mm and upto 185 sq. mm |
| 668 | Above 185 sq. mm and upto 400 sq. mm |
| 669 | MV CABLE |
| 670 | Supply,Testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium/cu conductor under ground cable, in built up cable trench/ already laid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth after cables are laid, providing protection with sand and bricks at sides and top and cable route markers at every 15mtr. interval and also at the turnings. The cable shall conform to IS 7098/ Part I. Armoring shall be IS 7098 Part IB |
| 671 | 3.5C X 300 Sq.mm |
| 672 | 3.5C X 185 Sq.mm |
| 673 | 3.5C X 120 Sq.mm |
| 674 | 3.5C X 95 Sq.mm |
| 675 | 4C X 25 Sq.mm |
| 676 | 4C X16 Sq.mm Cu |
| 677 | 4C X10 Sq.mm Cu |
| 678 | Providing double compressed type end terminations for the cable specified above with compression type gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland. |
| 679 | 3.5C X 300 Sq.mm |
| 680 | 3.5C X 185 Sq.mm |
| 681 | 3.5C X 120 Sq.mm |
| 682 | 3.5C X 95 Sq.mm |
| 683 | 4C X25 Sq.mm |
| 684 | 4C X16 Sq.mm |
| 685 | 4C X10 Sq.mm |
| 686 | EARTHING SYSTEM |
| 687 | Note : All Maintenance free earthing should be UL Listed and All Strip joint should be with UL LISTED Exothermice WELD POWDER . Nut bolt jointing are not accepted |
| 688 | Supply Installation testing of Maintenance free hot deep galvienised on 250 microns GI Earthing system with 10 ft long , 80 mm dia & 3.0 mm wall thickness. (Pipe-In-Pipe with Flat Terminal ) Tecnology.with 2 Bag of Teksai Electron High Conductive & Anti Corrosive Compound, Eco Friendly. Spec : 3 mtr Length x 80 mm dia/ 2 mm thick / 250 micron galvanised. Electrode Thickness : 3.0 mm / ISI Class - B, Hot Dip Galvanised 250 Microns Terminal size should be 40 x 10 mm thick (For use : All Body Earthing) with - CPRI ,ROHS, SPECTRO & NABL test certificate. Make- Alltec, ERICO |
| 689 | Supply Installation testing of Electrolytec Grade Copper Earthing system with 10 ft long , 63 mm dia & 2 mm wall thickness (Pipe-In-Pipe with Flat Terminal ) Tecnology. with 2 Bag of Teksai Ultra High Conductive & Anti Corrosive Compound,Eco frindly. Spec :3 mtr Length x 63 mm dia/ 1.6 mm thick. Terminal size should be 40 x 6 mm thick ( For Use :UPS,SERVER, DG,Xmer,& Etc Neutral Earthing.) With - CPRI ,ROHS, SPECTRO & NABL test certificate. Make- Alltec, ERICO |
| 690 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating All Strip joint should be with UL LISTED Exothermice WELD POWDER . |
| 691 | Providing and fixing 50 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required All Strip joint should be with UL LISTED Exothermice WELD POWDER .. |
| 692 | Providing and fixing 25 mm X 6 mm G.l. strip on surface or in recess for connections etc. as required All Strip joint should be with UL LISTED Exothermice WELD POWDER .. |
| 693 | Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/cable as required. |
| 694 | CHAPTER -XXIV FIRE ALARM SYSTEM |
| 695 | PANEL AND FLOOR REPEATER TERMINAL |
| 696 | Supply, installation, testing & commissioning of EN, VDS and FM approved 2 Loops Micro processor based 2 wire fault tolerant loop, total loop shall have the capability of connecting 252 devices.The fire alarm control panel shall have built in degarde mode function. The panel should have inbuilt TCP/IP communication for Panel Program and Remote Monitoring option through LAN or WAN communication.The panel shall be able to give location of all fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 2000 events.Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 8x40 characters LCD display with resolution of 256 X 112 pixels, and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Should have protection category of IP30. Also the panel should have the option to operate in manned and unmanned mode. The Panel Shall have the option of 24/48/96 Zones with Individual LED Indicators or with in the Loop mimic driver for 96 LED indicators.The panel shall have a built in power Supply, installation, testing & commissioning and battery charger along with maintenance free 45 to 100 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required and as per specifications |
| 697 | DETECTORS |
| 698 | Supply, installation, testing & commissioning of EN, VDS and FM approved Multi sensor detector with forward, backward scattering techlonolgy having dual Optical & heat sensors with inbuilt turbo Isolator and integral response indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air currents. Detector should have unique address for communication and assigned through panel with Mounting Base as required. |
| 699 | Supply, installation, testing & commissioning of EN, VDS, ATEX approved Explosionproof Addressable Multi sensor detector with Signal processing with Advanced Signal Analysis technology forward, backward scattering techlonolgy having dual Optical & heat sensors with inbuilt turbo Isolator and integral response indicator with 360 degree viewing angle along with Intrisically Safe Line adapter Module as required. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust,dirt, temperature fluctuations and air currents. Detector should have unique address for communication and assigned through panel with Mounting Base as required with the protection category of IP43. |
| 700 | Supply, installation, testing & commissioning of Flame proof beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. |
| 701 | DEVICES AND ALARM EQUIPMENTS |
| 702 | Supply, installation, testing & commissioning of EN, VDS and FM approved Intelligent addressable manual call point with inbuilt turbo Isolator suitable for flush or surface mounting, call point shall include test key feature without removing the glass. Also should have protection category of IP44 and extra acceesories as required. |
| 703 | Supply, installation, testing & commissioning of EN, VDS, ATEX approved Explosionproof Addressable manual call point with inbuilt turbo Isolator suitable for flush or surface mounting, call point shall include test key feature without removing the glass. Also should have protection category of IP44 and extra acceesories as required. |
| 704 | Supply, installation, testing & commissioning of Weatherproof addressable manual call point. Also should have protection category of IP66 and extra acceesories as required. |
| 705 | Supply, installation, testing & commissioning of EN, VDS and FM approved Intelligent addressable loop powered sounder with base, inbuilt turbo Isolator, able to provide an o/p of 99dBA at 1m shall have 11 programmable tones, 3 volume settings selectable from the panel and fully synchronized with other sounders and shall have the ability to switch between one tone for alert and one tone for evacuation. Shall have protection category of IP40 |
| 706 | Supply, installation, testing & commissioning of approved Intelligent Flameproof / Weatherproof sounder. Shall have protection category of IP65 |
| 707 | Supply, installation, testing & commissioning of EN, VDS and FM approved Addressable input module with inbuilt isolator and shall have the LED indication for Normal, Fault, test, and activation. The module shall have the option for configuration as fail safe operation |
| 708 | Supply, installation, testing & commissioning of EN, VDS and FM approved Addressable input/output module with inbuilt isolator and shall have the LED indication for Normal, Fault, test, and activation.The module shall have the option for configuration as fail safe operation |
| 709 | Supply, installation, testing, programming & commissioning of 2.5Km range Siren with weather proof motor with 220V 50HZ AC supply operation with required power contactor, MPCB for control all in a weather proof enclosure near motor including all installation materials as required. |
| 710 | Supply, installation, testing & commissioning of FRLSH 2C x 1.5 Sq.mm Armoured copper cable. |
| 711 | Supply, installation, testing & commissioning of MS rack with provision to mount above-mentioned rack mountable items |
| 712 | CHAPTER -XXV HVAC SYSTEM |
| 713 | AIR COOLED SCREW CHILLER |
| 714 | Supply, installation, testing & commissioning of 75 TR Actual capacity at 108°F Air Cooled Chilling Machine with screw compressor machines, suitable for R-134a refrigerant complete with compressor, chiller, air cooled condenser with epoxy coated fins, automatic stepless capacity control, vibration isolation arrangement, microprocessor based control panel, drive motor with coupling, soft starter, all controls and instruments, first charge of refrigerant and oil and all accessories as per specifications and drawings. Motor shall be suitable for 3 phase, 415 Volts ±10%, 50 Hz±5% AC supply. The machine should be complete with factory wired machine mounted control panel with necessary interlocking & safeties as per specifications. |
| 715 | Chiller will have unit mounted VFD with control panel min IP-55 protection class. |
| 716 | Evaporator |
| 717 | Water leaving temperature : 44° F |
| 718 | Water entering Temperature : 54° F |
| 719 | CHW-IN = 12.20C & CHW-OUT = 6.7°C |
| 720 | Fouling factor : 0.0005 FPS Unit |
| 721 | Ambient temperature:42.3 Degree C |
| 722 | The chilling machine as described above shall be in line with specifications. |
| 723 | 75 TR Actual Capacity (2 Working + 1 Stand By) |
| 724 | HOT WATER GENERATOR (HWG) (MONSOON RE-HEATING) |
| 725 | Supply, installation, testing & Commissioning of electrically operated multibank Hot Water Generator of 50 KW actual capacity having bank as per manufacturer and each bank made of 8mm M.S. sheet and dish end made of 10mm M.S. having 16 gauge stainless steel lining with heaters arranged in banks and Controller and Thermostat so that hot water is generated at 50°C with nominal variation, including 75mm thick resin bonded fiber glass insulation of 24 Kg / CUM density finished with 1.25mm thick aluminium sheet cladding including necessary Electrical panel with BMS compatible having suitable Incoming and outgoing Switchgears for Boiler, automatic Controls including inlet and outlet connections for water complete with pressure release valve, low level cut-out, Autovent sight-glass as per specification complete as required. |
| 726 | Heating capacity : 50 KW |
| 727 | Water in temp. : 45 deg C |
| 728 | Water out temp : 50 deg C |
| 729 | HWG as Above (1W + 1S) |
| 730 | PRIMARY WATER PUMP |
| 731 | Supplying, erection, testing and commissioning of Horizontal End-Suction Primary chilled water pump set capable of delivering 180 GPM of water against a head 12 Mtr. each pump shall comprise the following as required as per specifications. |
| 732 | 1 No. - Horizontal end-suction type pump with bronze impeller, S.S Shaft, C.I body and mechanical seal with integral reinforced flanged rubber bellows at suction and discharge side. |
| 733 | Duly insulated with 80 kg/cum density resin bonded fibre glass duly cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semi-circular sections as per specifications. |
| 734 | 1 No.- Suitable HP, TEFC squirrel cage induction motor, IE-3 with class 'F' insulation, IP -55 Protection, 1450 RPM , operating on 415 volts ± 10%, 3 phase, 50 Hz A.C. supply. (2 Working + 1 Stand By) |
| 735 | Pump set shall be complete with necessary vibration isolation arrangement, MS base plate, coupling guard, foundation bolts and all other accessories. |
| 736 | Min. pump efficiency at duty conditions shall be 75% |
| 737 | RCC/CC Foundation to be provided by contractor. |
| 738 | Pump as above ( 2W+1S) |
| 739 | SECONDARY CHILLED WATER PUMP WITH VARIABLE SPEED PUMPING |
| 740 | Supplying, erection, testing and commissioning of variable speed Horizontal End-Suction secondary chilled water pumping system with VFD and all pump system controller, comprising of: |
| 741 | Horizontal end-suction pump set with CED/Epoxy Coated Cast Iron casing, Bronze impellers with stainless steel shaft & with integral reinforced flanged rubber bellows at suction and discharge side. Pump connected to suitable capacity TEFC ventilated induction motor, IE-3 with class 'F' insulation, 1450 RPM, suitable for 415 volts ± 10%, 3 phase, 50 Hz A.C. supply. |
| 742 | Duly insulated with 80 kg/cum density resin bonded fibre glass duly cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semi-circular sections as per specifications. |
| 743 | Renewable wear ring of bronze shall be furnished on the casing. |
| 744 | Variable speed drive Panel should have a dedicated programmable logic controller with individual drive for each pump and with required no. of sensors and the entire unit has to be procured from the Pump manufacturer to ensure the smooth operation of the system. The Programmable logic controller shall be able to control minimum 1 Pump and maximum of 4.6 Pumps, Automatic cascade control of pumps, automatic sequence change, Friction loss compensation, pump status shall be there. Display shall be graphical type with minimum 320 pixels X 240 Pixels VGA display with backlight. Drive should have rated input frequency 50 Hz and output frequency range of 0.5 to 132 Hz. An IP41/IP55 Nema Standard powder coated steel enclosure for Basement, with sufficient capacity of cooling fan shall house all the electrical control components. |
| 745 | Microprocessor based control panel shall have suitable hardware & software so that it can be integrated directly to BMS with standard communication protocol using backnet / Modbus /any open Protocol. |
| 746 | (All the Pump set will have their control panel with respect to the motor rating & should be suitable for chilled water circulation). |
| 747 | All pumps to be provided with separate variable frequency drives. Control panel with respect to motor rating and should also consist of cooling fan, enclosoures etc. as required. |
| 748 | Mounting frame work with vibration isolation arrangement , coupling guard, foundation bolts and all other accessories. |
| 749 | Electronic Differential Pressure Transmitters as required. |
| 750 | Integral reinforced flanged rubber bellows at suction and discharge side. |
| 751 | Complete system to be mounted on a common MS base frame structure with base plate of pump and shall have following duty and characteristic: |
| 752 | Min. pump efficiency at duty conditions shall be 75% |
| 753 | RCC/CC Foundation to be provided by contractor. |
| 754 | Flow Rate : 180 GPM |
| 755 | Head : 28 Metre WC |
| 756 | Pump set complete with two pumps (2W+1S) |
| 757 | Supply, Installation, Testing and commissioning of Variable Speed Pumping System consisting of one number variable frequency drive (VFD) with disconnect switch / MCCB, with each secondary pump, dedicated one number microprocessor based pump controller duly down loaded with parallel pumping software & sensors / transmitters with each pumping circuit/zone. Common VFD Panel shall be provided with digital display showing electrical parameters like voltage, ampere, power consumption (KW & KWH) as well as % speed indication and / or % frequency indication. The entire system with variable speed pumps shall be sourced from the single vendor. The system shall be complete in all respects & suitable for following motor ratings: |
| 758 | HOT WATER PUMP (MONSOON-REHEATING) |
| 759 | Supply,erection, testing and commissioning of monoblock Hot water centrifugal pump for hot water recirculation, pump set capable of delivering 40 USGPM of water against 28 mtr head each comprising of the following and complete as required |
| 760 | 1 No. - monoblock type pump with bronze impellar and mechanical seal. |
| 761 | Duly insulated with 32 kg/cum density close cell cross linked cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications. |
| 762 | 2 Nos. - 150 mm dia dial type pressure gauges and stainless steel binders & vibration isolators. |
| 763 | 1 No. Suitable HP, TEFC squirrel cage induction motor (IE-3) with class 'B' insulation, 3000 RPM synchronous speed, operating on 415 Volts ± 10 % , 3 phase , 50 Hz A.C. supply. |
| 764 | Pump as above (1 working + 1 stand by) |
| 765 | CEILING SUSPENDED AHU |
| 766 | Supply, Installation, Testing and commissioning of factory built ceiling mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels with double fan consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required with, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep & 2 row deep heating coil, filter sections with 50 mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron & Fine filters having efficiency 99% down to 5 micron, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia dial type pressure gauges (2 nos.) and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. |
| 767 | 5500 CFM & 9.0TR for Utility with 15mm ESP |
| 768 | 6000 CFM & 10.0TR for CDCS with 15mm ESP |
| 769 | FLOOR MOUNTED AHU |
| 770 | Supply, Installation, Testing and commissioning of factory built floor mounted double skin type horizontal air handling units made of 43mm thick panels consisting of pre plasticized G.I. casing of 0.8mm outside layer and plane GI sheet of 0.8 mm inside layer with polyurethane foam (PUF) insulation of 32 kg/cum density injected between them, complete with DIDW backward curve SA blower section with blower suitable for required static pressure for supply air fan, 6 row deep & 2 row deep heating coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type pre filter having efficiency 90% down to 10 micron & Fine filters having efficiency 99% down to 5 micron, belt drive package with TEFC drive motor (IE-3) suitable for VFD operation at 415 ± 10% volts, 50Hz,3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia dial type pressure gauges (2 nos.) and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. |
| 771 | 34000 CFM & 60.0TR, ESP 30mmSp |
| 772 | Active Purification System (Bi-Polar Ionization) For AHU/DUCTABLE/VRF |
| 773 | Supply, Installation, Testing and commissioning of Bipolar Ionisation System. The Bipolar Ionization System must be a combination of Needle Point Model for AHU (Needle Point should have Nitinol (nickel titanium) Needles and Carbon Fiber Brush Model for Cassettes and HI Wall AC units. The System should produce positive and negative ions for creating a Bio Climate rich in ions and hence neutralizing harmful pollutants including pathogens, Volatile Organic Compounds and Particulate Matter. The Carbon Brush self-balancing ionizer should be installed at the fan inlet of fan coil units, VRF cassettes, ductless splits , NeedlePoint Ionizer shall be installed at AHU and Ductable HVAC System. Make- IntelliGreen/ Airultra/Eco-Green Engineers |
| 774 | Product should have UL 867 and UL 2668 certification (for zero ozone emission). The OEM shall have Efficacy test report on COVID from any Internationally/Nationally recognised Laboratory. The technology shall also have UL 2043 for Fire and Smoke safety certificate , ISO 16000 for safety against any Organic Byproduct and CSAC22.2#187 , CARB certification. |
| 775 | Manufacturers shall provide Test report from Internationally/Nationally recognized Lab for proven efficacy on below pathogens with minimum kill rates for the following pathogens given the allotted time and in a space condition:a) SARS-CoV-2 (COVID-16) Human Strainb) MS2 Bacteriophage (Surrogates COVID-16)c) Omicron Variant of SARS-CoV-2d) H1N1e) Total Bacterial Count Reduction rate of more than 60% from NABL Accredited Labf) Yeas G Mold/Total fungal count Reduction rate of more than 60% from NABL Accredited Lab |
| 776 | AHU/DUCTABLE/VRF |
| 777 | 5500 CFM & 9.0TR for Utility with 15mm ESP |
| 778 | 6000 CFM & 10.0TR for CDCS with 15mm ESP |
| 779 | 34000 CFM & 60.0TR, ESP 30mmSp |
| 780 | Electronic Air Cleaner For AHU/DUCTABLE |
| 781 | Make- IntelliGreen/ Airultra/Eco-Green Engineers |
| 782 | The EAC Shall be suitable to reduce harmful pollutants like particulate matter (PMx), PM 2.5, allergens, smoke, bacteria, pathogens etc. based on below principle technology viz; Impingement, Polarization and Agglomeration for passive air purification. It should be a slim structured unit specifically designed for integration in Return Air path of ceiling suspended indoor units and AHUs. EAC shall be equivalent to Merv-14 or Higher efficiency for AHU and Ductable Units with low pressure drop. It should have 3x working principles and it should be aluminum based or powder coated steel casing and should be self-contained. The EAC shall have UL certified core components. The units shall meet ANSI/ASHRAE 52.2/ISO16860 standards and have valid test report to verify filtration efficiency. The Supplier shall carry UL2668 certificate for testing against Zero Ozone Emission either as Whole unit or included components. The filter shall be capable of effectively reducing haze particles, smoke, mold spores, and airborne bacteria, and shall be supported by test reports from NABL-accredited laboratories verifying its performance. The Electronic Air Cleaner shall be GreenPro certified by CII–IGBC (Confederation of Indian Industry – Indian Green Building Council to support ECBC compliance by ensuring energy-efficient operation, low pressure drop, and improved indoor air quality .In addition, the EAC shall include provision for smart monitoring through integrated sensors (Air flow and differential pressure Data shall be compatible with BMS/IoT platforms (Modbus/Wi-Fi). In addition, the EAC shall include provision for smart monitoring through integrated sensors (airflow and differential pressure). Data shall be compatible with BMS/IoT platforms (Modbus/Wi- Fi). The system shall support analytics such as filter health indication and early maintenance alerts, with an option for integration into AI-based dashboards for trend analysis and compliance reporting. |
| 783 | Floor Mounted AHU CFM |
| 784 | 5500 CFM & 9.0TR for Utility with 15mm ESP |
| 785 | 6000 CFM & 10.0TR for CDCS with 15mm ESP |
| 786 | 34000 CFM & 60.0TR, ESP 30mmSp |
| 787 | CHILLED WATER PIPING |
| 788 | ABOVE GROUND PIPING |
| 789 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required. Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. |
| 790 | Pipe in air ( Al. Cladding) |
| 791 | 125mm dia (50mm thick insulation) |
| 792 | 100mm dia (50mm thick insulation) |
| 793 | 80mm dia (50mm thick insulation) |
| 794 | 65mm dia (50mm thick insulation) |
| 795 | 50mm dia (50mm thick insulation) |
| 796 | 40mm dia (50mm thick insulation) |
| 797 | 32mm dia (50mm thick insulation) |
| 798 | 25mm dia (50mm thick insulation) |
| 799 | Burried Pipe (Sand cement plaster instead of Al. Cladding) |
| 800 | 125mm dia (50mm thick insulation) |
| 801 | 50mm dia (50mm thick insulation) |
| 802 | Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. |
| 803 | Supplying, fixing, testing and commissioning of BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile rubber sheet & O - ring & PN 16 pressure rating for chilled water/hot water circulation as specified. |
| 804 | 125mm dia |
| 805 | 100mm dia |
| 806 | 80mm dia |
| 807 | 65mm dia |
| 808 | 50mm dia |
| 809 | 40mm dia |
| 810 | Supplying, fixing, testing and commissioning of BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water / hot water circulation as specified. |
| 811 | 100mm dia |
| 812 | 80mm dia |
| 813 | 65mm dia |
| 814 | 50mm dia |
| 815 | 40mm dia |
| 816 | 32mm dia |
| 817 | 25mm dia |
| 818 | Supplying, fixing, testing and commissioning of NON - RETURN VALVE WITH dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. |
| 819 | 100mm dia |
| 820 | 50mm dia |
| 821 | Supplying, fixing, testing and commissioning of Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation with permanent magnet and including insulation as specified. |
| 822 | 100mm dia |
| 823 | 80mm dia |
| 824 | 50mm dia |
| 825 | 40mm dia |
| 826 | Supplying, fixing, testing and commissioning of BALL VALVE WITH STRAINER |
| 827 | 25mm dia |
| 828 | 32mm dia |
| 829 | Supplying, fixing, testing and commissioning of BALL VALVE WITHOUT STRAINER |
| 830 | 25mm dia |
| 831 | 32mm dia |
| 832 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 833 | Providing & fixing in position the mercury in glass industrial type thermometers. |
| 834 | Providing & fixing Auto Air - purge valve of 15mm dia (Air Vent will be fitted with an isolating ball valve ) & complete as per specifications. |
| 835 | Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required. |
| 836 | 100mm dia (Chiller) |
| 837 | Supply, Installation, testing and commissioning of TWO WAY MODULATING VALVES provided with spring return function & fitted with modulating actuators in chilled water lines at each air handling unit / chilled water cassette unit. The actuator shall have required shut off capability of minimum 4 bar rating. The valves & actuators for AHU’s shall be compatible with Building Automation System. The actuator shall be provided with interface cards to receive 0-10V or 4-20 mA signal from Building Automation System. The valve shall be suitable for following pipe sizes and provided with matching flanges and accessories. |
| 838 | 80mm dia |
| 839 | 50mm dia |
| 840 | 40mm dia |
| 841 | 20mm dia |
| 842 | Pressurised Expansion tank to compensates for pressure variation due to water volume changes with temperature variations in HVAC systems. Tank shall be suitable to maintain constant water flow. The tank should have Mild steel shell, Interchangable EPDM / Butyl membrance. It can be suitable for maximum operating pressure 10 bar and working temperature -10°C to 100°C. Pressurised tank shall be complete with suitable arrangements, valves, Spring loaded pressure relief valve, make up water pumps, Air vent with MS shell and brass made venting device and also with Microprocessor based control panel. |
| 843 | capacity: 500 Ltrs |
| 844 | FLEXIBLE CONNECTIONS |
| 845 | Supply, Installation, Testing and commissioning of Flexible connector for following dia pipe having PN 16 pressure rating to be installed at pump and chiller suction and discharge & complete as per specifications. |
| 846 | 100mm dia |
| 847 | 50mm dia |
| 848 | Providing and fixing in position of approved make Flow Switch complete with copper control wiring at condenser outlet of each machine. |
| 849 | Supplying, fixing, testing and commissioning of medium class G.I. condensate drain pipes on wall/floor/roof of following size/diameters duly insulated with 9 mm thick closed cell nitrile rubber insulation in the form of pre-formed pipe sections and along with necessary clamps, fittings such as bends, tees etc. adequately supported as per specifications and as required. |
| 850 | 40 mm dia |
| 851 | 32 mm dia |
| 852 | 25 mm dia |
| 853 | 20 mm dia |
| 854 | Air seperator for chilled water in MS construction with SS internal perforated sheet, with insulation 32mm and 25 guage aluminium cladding with diamond finish and necessary valves etc. suitable for the flow rate. |
| 855 | 360 GPM & 125mm dia. |
| 856 | DX TYPE HI WALL SPLIT UNIT |
| 857 | Supply, Installation, Testing & Commissioning of 5 star rated DX Type Hi wall split air-conditioning unit with Refrigerant R-410A consisting of condensing unit with fan motor, hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of proper insulated copper tubing up to 10 RMT(G & L). Cost includes double coat painted M.S. Stand, Gas Charging & Internal Copper Wiring & Remote Control, power wiring, stablizer alongwith each unit (set of indoor & outdoor unit) etc for below mentioned capacity |
| 858 | 1.5 TR Hi-wall split |
| 859 | 2.0 TR Hi-wall split |
| 860 | REFRIGERANT PIPING |
| 861 | Supply,installation,Testing & commissioning of pair of copper refrigerant pipe as per unit tonnage (SoftPipe) & work insulated with13mm thick elastomeric nitrile rubber tubular insulation,complete with refrigerant topping for split units |
| 862 | 1.5 TR Hi-wall split |
| 863 | 2.0 TR Hi-wall split |
| 864 | Supply, intallation, erection and testing of 2 core 1 sq mm transmission wire in MS conduit including clamps ties etc. |
| 865 | AIR DISTRIBUTION |
| 866 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet (with 120gsm galvanization) metal rectangular ducting with supports as per SMACNA complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following gauges:- |
| 867 | 24 Gauge ( Thickness 0.63mm) |
| 868 | 22 Gauge (Thickness 0.8mm) |
| 869 | 20 Gauge (Thickness 1.0mm) |
| 870 | 18 Guage (Thickness 1.25mm) |
| 871 | Supply, installation, balancing and commissioning of site fabricated at site GSS sheet (with 120gsm galvanization) metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 872 | 24 Gauge ( Thickness 0.63mm) |
| 873 | 22 Gauge (Thickness 0.8mm) |
| 874 | 20 Gauge (Thickness 1.0mm) |
| 875 | 18 Guage (Thickness 1.25mm) |
| 876 | Supply, installation , testing and commissioning of GI Volume control duct damper complete with neoprene rubber gasket, nuts, bolts, screw linkages, flanges etc., as per specifications. |
| 877 | Supplying & fixing of powder coated extruded aluminium Supply / Exhaust Air Grills with aluminium volume control dampers as per specifications. |
| 878 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. |
| 879 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. |
| 880 | Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. |
| 881 | Supplying, fixing testing commissioning of thermal insulated flexible duct of following sizes duly suppoeted at regular interval as per site requirement etc complete as required as per specifications. |
| 882 | 200mm dia |
| 883 | 150mm dia |
| 884 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. |
| 885 | Fire damper |
| 886 | Actuator |
| 887 | Supplying, fixing, testing & commissioning of powder coated extruded aluminium section fresh air louvers in weather maker room with aluminium volume control dampers, bird screen etc completed as required. |
| 888 | Supplying & fixing of powder coated extruded aluminium Door Transfer Grills with louvers but without volume control dampers complete as required. |
| 889 | Jet Nozzles shall be suitable for long throws with ultra low noise charecteristics with inbuilt manual adjustment for variation in discharge angle. Nozzles shall have proper venturi type construction to provide long throw. The angular range 30° upwards to 30° downwards. Jet nozzles consist an aerodynamically designed eye ball type nozzle deep drawn in one single piece without any fixing holes or fasteners. The nozzle is housed in a specially designed housing with a mounting flange with holes for fastening the nozzle. The surface is pre treated and powder coated finished of shade as specified by Engineer In Charge. |
| 890 | 400 mm dia |
| 891 | 310 mm dia |
| 892 | INSULATION |
| 893 | Supply and fixing of acoustic lining of supply air duct and plenum with 15 mm thick open cell Nitrile Rubber (class-1) having density of 140-180 kg/m³, fire retardent BS 476 Part 7A & 7C. The joint cell be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |
| 894 | Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50 mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610 mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications. |
| 895 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish, closed cell Nitrile rubber (Class “O”) insulation on duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |
| 896 | 19mm (on supply air duct) |
| 897 | 25mm (on supply air duct) |
| 898 | MV PANEL |
| 899 | Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA sheet for main frame and 1.6mm thick for partitions after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. |
| 900 | The PCC shall have atleast two spare cubicles to suit the highest rating outgoing MCCB. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type and shunt trip coils, wherever Electrical Interlocking is specified. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. All ACBs/MCCBs 160A and above shall be with Micro processor releases. All CTs/CBCT shall be resin cast type. All MCCBs below 160A shall be with Adjustable Thermal Magnetic based releases. All ACBs/MCCBs shall be Icu=Ics=100% .All MCCBs shall be provided with spreader links and Rotary handles |
| 901 | Fully automatic DOL starter suitable for 18.5 KW motor including 25A 4P MCB 'C', Push Buttons, LED Indications, Auto/ Manual/ OFF selector switch, SPPR, FRLS copper control/ power wiring etc. Complete as required. |
| 902 | PLANT ROOM |
| 903 | Incoming : |
| 904 | 630A, 50KA 4P MCCB with Microprocessor based releases O/C, S/C & E/F-1 Set |
| 905 | Busbars : 800A TP100%N Aluminium busbar - 1 Set |
| 906 | Outgoings : |
| 907 | 320A, 50KA TPN MP MCCB – 4 Sets |
| 908 | 125A, 50KA TPN MP MCCB – 3 Sets |
| 909 | 4 Nos Fully automatic DOL starter suitable for 7.5 KW motor including, MCCB, Push Buttons, LED Indications, Auto/ Manual/ OFF selector switch, SPPR, FRLS copper control/ power wiring etc. Complete as required. |
| 910 | 3 Nos Fully automatic DOL starter suitable for 5.5 KW motor including, MCCB, Push Buttons, LED Indications, Auto/ Manual/ OFF selector switch, SPPR, FRLS copper control/ power wiring etc. Complete as required. |
| 911 | 4 Nos Fully automatic DOL starter suitable for 3.7 KW motor including, MCCB, Push Buttons, LED Indications, Auto/ Manual/ OFF selector switch, SPPR, FRLS copper control/ power wiring etc. Complete as required. |
| 912 | 0-500V Digital Voltmeter with selector switch and MCCBs- 1 Set |
| 913 | 0-400A Digital Ammeter with CTs of ratio 400/5A,Class 1 Accuracy and 15VA burden and selector switch- 1 Set |
| 914 | LED Phase indication lamps with individuals MCBs and control - 1 Set |
| 915 | CT Operated Multi Functional Meter with RS485 connectivity - 1 Set |
| 916 | Total Panel shall be provided with CO2 gas suppression system. |
| 917 | INDOOR AHU PANEL (IP -55), Ics=Icw= 35KA |
| 918 | Incomer:- |
| 919 | 1 No. Incomer 160Amps 4 pole MCCB, 35KA with microprocessor based releases for O/C, S/C & earth fault protection settings |
| 920 | Control and metering chamber: |
| 921 | 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. VAF + PF Meters meter with matching cast resin CT's. |
| 922 | Bus Bar |
| 923 | One set of 4P, AL. bus bar rated 300 Amps for phases and neutral for half capacity of phases. |
| 924 | The outgoing feeders are as follows : |
| 925 | 3 Nos Fully automatic Star Delta starter suitable for 22.0 KW motor including, MCB, Push Buttons, LED Indications, Auto/ Manual/ OFF selector switch, SPPR, FRLS copper control/ power wiring etc. Complete as required. |
| 926 | 3 Nos Fully automatic DOL starter suitable for 3.7 KW motor including, MCB, Push Buttons, LED Indications, Auto/ Manual/ OFF selector switch, SPPR, FRLS copper control/ power wiring etc. Complete as required. |
| 927 | Total Panel shall be provided with CO2 gas suppression system. |
| 928 | INDOOR AHU PANEL(IP-65), Ics=Icw= 35KA |
| 929 | Supplying, Installation, Testing and Commissioning dust, damp and vermin proof wall mounting with 80/100 Amp Isolator for AC unit with suitable MS Box with connection complete as required. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail