|
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 2 | Providing, Supply and laying of lime concrete in floor 20 to 25 mm brick ballast of well burnt ) mixed with 50% lime morter in ratio of 1:1:1 (1-U.Katni lime , 1-surkhi,1- C.sand ) [cum] |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 4 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 5 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 8 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) |
| 9 | Providing and fixing internal wall panels on Light gauge steel frame work with 12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on cement board as per standard sizes fixed with selfdrilling / taping screws / fasteners @ 60cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately SUB HEAD : 26- NEW TECHNOLOGIES AND MATERIALS 2116. 26.43.1Cement Fiber Board 8 mm thick as per IS 14862:2000 oftype B (High pressure Steam Cured) |
| 10 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including waterthinnable priming coatwith cement primer |
| 11 | Providing and fixing Plumbing & Electrical articels for cafeteria etc complte including with fixing chargesWire Bundle 2mm . [EACH] |
| 12 | Wire Bundle 4mm [ [EACH] |
| 13 | Single Core MCB 32 Amp [EACH] |
| 14 | Single Core MCB 25 Amp [RMT] |
| 15 | 3 Core MCB 63 Amp [EACH] |
| 16 | MCB Box Double Door [EACH] |
| 17 | 3/4 Pipe Electric (Bundle) [EACH] |
| 18 | 3 core armoured cable 16 mm [RMT] |
| 19 | 2'x2' LED light 20 watt [EACH] |
| 20 | Modler Switch 5Amp [EACH] |
| 21 | Combind Box 15Amp [EACH] |
| 22 | Celing Fan (Havells/ orient/ atomberg) [EACH] |
| 23 | Flexible Pipe (PKT) [EACH] |
| 24 | Bend (PKT) [EACH] |
| 25 | Exhaust Fan 15\\" Heavy duty [EACH] |
| 26 | Tap Box [RMT] |
| 27 | T point [EACH] |
| 28 | B) Plumbing Item , 3/4\\" Pipe [EACH] |
| 29 | Tee 3/4\\" [EACH] |
| 30 | Elbow 3/4\\" [EACH] |
| 31 | Socket 3/4\\" [EACH] |
| 32 | Union 3/4\\" [EACH] |
| 33 | Gate Wall 3/4\\" [EACH] |
| 34 | Water storage tank 1000 ltr tripple layer [EACH] |
| 35 | Tank Nipal 3/4\\" [EACH] |
| 36 | Solution (1000gm) [EACH] |
| 37 | Elbow Cudi 3/4\\" [EACH] |
| 38 | Sink 24X18 [EACH] |
| 39 | washbasin with vanity [EACH] |
| 40 | 1.5 HP Motar (kirloskar,Crompton or equivalent) [EACH] |
| 41 | Waste Pipe [EACH] |
| 42 | Starter For the motar [EACH] |
| 43 | Electrical and Plumbing fitting [LS] |
| 44 | Random rubble stone Masonry with required size of D.Q. Stone in the core in Lime mortar 1:1:1 (1 lime, 1 Surkhi, 1 C.sand) including supply of all materials labour T&P etc. required for proper completion of work. |
| 45 | Filling the cavities of over hanginig stone of Archs and dome with lime mortar 1: 1 : 1, (1 lime , 1 coarse sand , 1 surkhi mixed with 50% brick zira 6 to 10 mm including curing with in 500 mtrs lead & approx 15m hieght complete. |
| 46 | Providing 100mm thick Ornamental Plaster on the wall and squenches as per existing design and pattern in lime mortar 1:1:1 (1Lime: 1Surkhi: 1Sand) design of arches etc including Finishing Curing etc.complete. |
| 47 | Provision for Recessed Pointing the Open Joints of R.R. Masonry in Lime Surkhi Mortar 1:1:1 (1 Lime : 1 Surkhi : 1 Coarse Sand) mixed with adhesive materials such as belgiri, gur, gum & san with racking, cleaning & washing the joints including carriage of water & material with in a lead upto 100M approx. |
| 48 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. |
| 49 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturer's specification, with all 4 side tapered and backed byacoustical tissue with NRC value not less than 0.60 |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 51 | Provision for Providing and Fixing 15mm Foam Aluminium Foil for under roof insulation |
| 52 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 53 | Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineerin- charge |
| 54 | \\"Providing and fixing 37 mm thick factory made PVC Door shutter, style and rails made of PVC hollow extruded printed and laminated sectionhaving overall dimension 115 mm x 37 mm with wall thickness 2 mm (±0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 28 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in stylesandrails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and dir |
| 55 | Provision for essential articles required at site while execution of work and visitors amenitiesPVC Bucket [EACH] |
| 56 | PVC Mug [EACH] |
| 57 | PVC Helmet for labour [EACH] |
| 58 | Wire Brush [EACH] |
| 59 | PVC Gum Boot (Pair) [EACH] |
| 60 | PVC drum (200 ltr. [EACH] |
| 61 | MS Gate lock (Fixed on MS Gate) [EACH] |
| 62 | PVC Pipe 1inch (50mtr) [EACH] |
| 63 | washbasin with vanity cabinte [EACH] |
| 64 | Red sand stone benches( 1.50x 0.60) with four feet (H=0.45ft) [EACH] |
| 65 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 12.47.1 2 mm thick corrugated (2.5” or 4.2” or 6”) or step-down (2” or 3” or 6” ) as specified |
| 66 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1For thickness of tiles 10 mm to 25 mm |
| 67 | Dismantling old plaster or skirting surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 68 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) : Removal of Concrete Filling of sunken area around the Floor Taps to shift the same. |
| 69 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of areas 3 SQM or less |
| 70 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by EngineerinCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. NOTE: Item no 8.31 is brought from Sub Head 11 i.e. \\" |
| 71 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws) |
| 72 | 13.12 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge. |
| 73 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood |
| 74 | Providing and fixing White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required |
| 75 | Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal |
| 76 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. [EACH] |
| 77 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. 8.10.2 Granite Stone of approved shade |
| 78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 18.8.3 25 mm nominal dia Pipes |
| 79 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge |
| 80 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 17.28.2 Flexible pipe 17.28.2.2 40 mm dia |
| 81 | Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastner with necesary stainless steel screws, all complete as per direction of Engineer-in- charge. |
| 82 | Providing and fixing 18 mm thick ( Grenite ) gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Area of slab over 0.50 sqm) |
| 83 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (Marble work) |
| 84 | Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity. Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. Please Enable Macros to View BoQ information |