| 1 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 2 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position :Local best quality Uningthou wood |
| 3 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (framework to be paid separately):Natural colour insulating 12 mm thickboard |
| 4 | Wiring Items |
| 5 | Wiring for light point / Fan point/ Exhaust Fan ponit / Call bell point with 1.5mm2 PVC insulated copper conductor single core cable in PVC casing and capping with piano type switch phenolic laminated sheet suitable size MS -Box and earthing the point with 1.5mm2 PVC insulated copper conductor single core cable etc. as reqd. |
| 6 | 1. Group A |
| 7 | 2. Group B |
| 8 | 3. Group C |
| 9 | Wiring for light pont / power plug with 2x4mm2 PVC insulated copper conductor single core cable in PVC casing and capping along with 1 no. of 4mm2 PVC insulated copper conductor single core cable for loop earthing etc. as reqd. |
| 10 | 1. Light plug point - 54 Pt |
| 11 | 2. Power plug point - 24 Pt |
| 12 | Total |
| 13 | S/F PVC box of size 101mmx178mm (Nominal size)/(4''x7'')PVC board on surface including P/F 3 pin 5/6 amp socket outlet and 5/6 amp piano type switch connection etc as reqd. |
| 14 | S/F PVC box of size 152mmx203mm (Nominal or size)/(6''x8'')PVC board on surface including P/F 6 pin 15/16 amp socket outlet and 15/16 amp piano type switch connection etc as reqd. |
| 15 | Wiring for circuit / sub- main wiring along with earth wire with (the following sizes of ) FR PVC insulated copper conductor single core cable in PVC casing & capping etc. as reqd. |
| 16 | a. 2x1.5mm2 + 1x2.5mm2 earth wire |
| 17 | b. 2x2.5mm2 + 1x2.5mm2 earth wire |
| 18 | c. 2x4mm2 + 1x4mm2 earth wire |
| 19 | Fitting Accessories |
| 20 | Supplying & fixing stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc as reqd. |
| 21 | 76.2mmX76.2mm conicalround plate |
| 22 | S/Fbrass batten /angle holder i/c conection etc as reqd. |
| 23 | S/F 3 pin 5 amp ceiling rose on the existing junction box /wooden block i/c connection etc as reqd |
| 24 | S/F 48'' Sweep (1200mm) A.C ceilling fan complete with down rod canopy, 3 (three) blades but without regulator etc as reqd.( Make Bajaj/Usha or simillar) |
| 25 | S/F 20 w CFL lamp |
| 26 | Supplying and fixing 5 amp to 32amp rating 230 V 'B' series MCB for lighting and other load of ( following poles ) in the existing MCB DB complete with connection testing and commissioning etc as reqd. |
| 27 | 1. Single pole |
| 28 | S/F( following rating) double pole 240v isolator in the existing MCB DB complete with connection ,testing and commissioning as reqd. |
| 29 | 1. 40 amp |
| 30 | 2. 63 amp Please Enable Macros to View BoQ information |