| 1 | Lumpsum price for Hiring of services for Electrification works |
| 2 | Lumpsum price for Hiring of services for Electrification works of KG school at ONGC Colony Nazira, Assam Asset |
| 3 | Lumpsum price for Hiring of services for Electrification works of KG school at ONGC Colony Sivasagar, Assam Asset |
| 4 | Lumpsum price for Hiring of services for Electrification works of KG school at ONGC Colony Lakwa, Assam Asset |
| 5 | Lumpsum price for Hiring of services for Electrification works for facility creation at Central Store, ONGC Sivasagar Please Enable Macros to View BoQ information Name of work: Hiring of services for Electrification works of KG school at Nazira colony, ONGC Assam Asset SL ITEM DESCRIPTION UNIT QTY. Rate exclusive of GST Total amount exclusive of GST (Rs.) (Rs.) (A) (B) (C) (D) (E) (F) |
| 6 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group A(Short point) Point 18.0 894.79 16106.29 b) Group B (Medium Point) Point 21.0 1045.28 21950.84 c) Group C (Long point) Point 60.0 1302.09 78125.52 |
| 7 | Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Meter 720.0 247.8 178418.14 b) 2 x 4 sq. mm + 1 X 4 sq. mm earth wire Meter 360.0 300.97 108348.47 c) 2 x 6 sq. mm + 1 X 6 sq. mm earth wire Meter 140.0 395.58 55381.71 |
| 8 | Supplying and fixing piano type switch/socket of existing switch board including connection etc. a) 5/6 Amp switch Each 115.0 46.86 5388.59 b) 15/16 Amp switch Each 8.0 109.03 872.27 c) 5/6 Amp socket Each 33.0 62.18 2051.81 d) 15/16 Amp socket Each 8.0 123.45 987.61 e) Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. Each 1.0 89.21 89.21 f) Push bell Each 1.0 74.79 74.79 g) Supply and fitting 3 point 5Amp Ceiling rose Each 100.0 78.4 7839.58 |
| 9 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a) 125 A, 16 KA,TPMCCB Each 1.0 4344.21 4344.21 |
| 10 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 12 way double door Each 4.0 2086.05 8344.2 |
| 11 | Supplying, fitting and fixing 2 module stepped type Electronic fan regulator on the existing modular plate including connections etc. as required |
| 12 | Supplying including fitting and fixing of the following A.C Ceiling fan complete with all accessories like down rod, canopy etc. of the following sweeps with making necessary connections as approved by the Dept. As required complete and as directed by the Dept. (Without regulator). a) Standard model 1400 mm Sweep. \\"ORIENT PSPO make) / Usha make)/ CROMPTON make)/ Havells/ ATC/ V GAURD make) Each 36.0 1910.48 68777.14 |
| 13 | Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Dept.)as required complete and as directed by the Department. a) High Speed 225 mm sweep (ORIENT make), Trans Air 225 mm sweep (Crompton make), Ventil Air DX 250 mm sweep Louver type (Havells make) Each 8.0 1571.43 12571.43 |
| 14 | Supply, installation, testing & commissioning of pre wired, 18-20 watt LED tube light fitting including complete with all accessories directly on wall/ceiling i/c connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required. |
| 15 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole Each 30.0 230.68 6920.46 |
| 16 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 12 way (4 + 36), Double door Each 1.0 11563.84 11563.84 |
| 17 | a) 40Amp Each 2.0 391.98 783.96 b) 63Amp Each 10.0 474.88 4748.81 |
| 18 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia. including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 19 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required. |
| 20 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour(Aluminium for single core upto 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm. 3 x 10 sq mm, 4x6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, a) 16.00 Sq. mm.4 Core armoured U.G. cable Meter 200.0 398.1 79619.05 Total amount exclusive of GST = Rs. 738954.8 Total amount inclusive of GST @18% = Rs. 8,71,966,67 Name of work: Hiring of services for Electrification works of KG school at Sivasagar colony, ONGC Assam Asset SL ITEM DESCRIPTION UNIT QTY. Rate exclusive of GST Total amount exclusive of GST (Rs.) (Rs.) (A) (B) (C) (D) (E) (F) |
| 21 | Wiring for light point with 2x 1.5 sq mm P.V.C insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade upto 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Dept.) with flat 19mm ISI marked casing 'n' capping (AKG/ Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the dept.) system complete. a) Medium point up to 6.00 meter length Each 6.0 597.14 3582.86 b) Long point up to 10.00 meter length Each 75.0 879.05 65928.57 |
| 22 | Wiring for fan point with 2x 1.5 sq mm P.V.C insulated single core unsheathed industrial(Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade upto 1100 volts(Finolex/RR Kabel or Equivalent Make as approved by the Dept.) with flat 19mm ISI marked casing 'n' capping (AKG/ Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the dept.) system complete. a) Medium point up to 6.00 meter length Each 10.0 597.14 5971.43 b) Long point up to 10.00 meter length Each 55.0 879.05 48347.62 |
| 23 | Wiring for drawing sub main line with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Dept.) in surface flat ISI marked casing 'n' capping (AKG/ Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the dept.) system including earth continuity. a) With 2x2.5 sq. mm + earth continuity with 1x1.5 sq mm in flat 19 mm ISI marked casing 'n' capping system Meter 60.0 139.05 8342.86 b) With 2 x 6 Sq. mm + earth continuity with 1 x 4 sq. mm cable in surface flat 25 mm ISI marked casing 'n' capping system. Meter 120.0 239.05 28685.71 |
| 24 | Supply and fixing of following size PVC board fixing on wall complete as required. a) 4\\" X 4\\" Each 1.0 52.57 52.57 b) 7\\" X 4\\" Each 20.0 64.31 1286.2 c) 8\\" X 10\\" Each 14.0 153.31 2146.34 |
| 25 | Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc as required. a) 6 Amp Switch Each 172.0 46.86 8059.45 b) 16 A Switch Each 17.0 109.03 1853.57 c) 6 A Socket Each 26.0 62.18 1616.58 d) 16 A Socket Each 17.0 123.45 2098.67 e) Bell Push Each 1.0 74.79 74.79 |
| 26 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, phosphatised Powder Painted cubical outdoor double door, floor mounting compartmentalize panel boards of size 1.35M x 1.50 M x 0.40M made of 16 SWG (1.66mm) thick C.R sheet and 40mmx40mmx5mm size angle having 4 nos legs at the bottom and C.R sheet roofing on the top complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1:3:6 PCC foundation including excavation of trench and brick soling etc. complete neatly wiring done with provision for one no 160A 4P MCCB or switch fuse Unit as incomer and provision for 8 nos DP or TPN out goings as specified and directed by the deptt confirming to IP65 protection comprising of the following elecrical items: 1. 25mm x 5mm 4 strip Copper Bus-Bar 1.40 M length each 2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 No 3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 No 4. Pilot Lamp with integral ckt LED 110-230 V (Red, Yellow & Blue)- 3 Nos 5. Voltmeter and Ammeter Selector Switch- 2 Nos 6. 2 A Slide fuse unit- 3 Nos (Incoming and outgoing Switch Gears of required ratings will be measured and paid separately) |
| 27 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. a) 125 A , 36KA, FPMCCB Each 1.0 7397.14 7397.14 |
| 28 | Supplying and fixing following way, Single pole and nuetral, sheet steel, MCB distribution board, 240 V, on surface, recessed complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. a) 12 way Double door Each 8.0 2086.05 16688.4 |
| 29 | Supplying and fixing 6-32 amps rating, 240V/415 Volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required a) Single Pole Each 30.0 230.68 6920.46 b) Double Pole Each 8.0 591.12 4728.98 c) Triple Pole & Neutral Each 4.0 1106.55 4426.21 |
| 30 | Supplying including fitting and fixing of the following A.C Ceiling fan complete with all accessories like down rod, canopy etc of the following sweeps with making necessary connections as approved by the Deptt. As required complete and as directed by the Department( Without regulator). a) Standard model 1200 mm sweep Each 50.0 1817.14 90857.14 |
| 31 | Supplying, fitting and fixing of ceiling fan regulator including connections etc. complete as required. a) Electronic type Each 50.0 137.14 6857.14 |
| 32 | Supplying including fitting & fixing of following AC Exhaust fan in the existing hole on the wall of following sweeps with making necessary connections as approved by the Deptt. As required complete and as directed by the Department. (Domestic) a) 225 mm sweep Each 4.0 1655.24 6620.95 |
| 33 | Supplying and fixing of call bell/Buzzer suitable for single phase, 230 V complete as required. |
| 34 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor upto 10 sq mm balance stranded conductor, XLPE insulated, cores laid up, PVC tape inner sheathed , Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2 x 10 sq mm. 3 x 10 sq mm, 4 x 6 sq mm balance all galvanised steel strip), extruded PVC tape ST2 sheathed, 650/1100 KV grade as per IS 7908(Part 1) 1988 armoured U.G cable laid in ground /partially in air(as required for termination over ground including excavation of cable trench up to depth of 75 cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoils, debris etc to proper place as specified and directed by the deptt.(Nicco/ Havells/ RPG/ CCI/ Polycab/ Gloster/ Finolex make or equivalent). a) 4 Sq mm 3 Core armoured U.G cable Meter 60.0 311.43 18685.71 b) 50 Sq mm 4 Core armoured U.G cable Meter 50.0 676.19 33809.52 |
| 35 | Supply and installation of 20 W LED tube light along with all fittings and accessories, as directed by the deptt. Total amount exclusive of GST = Rs. 416728.79 Total amount inclusive of GST @18% = Rs. 491739.97 Name of work: Hiring of services for Electrification works of KG school at Lakwa colony, ONGC Assam Asset SL ITEM DESCRIPTION UOM QTY Rate exclusive of GST Total amount exclusive of GST (Rs.) (Rs.) (A) (B) (C) (D) (E) (F) |
| 36 | Wiring for light point /fan point / exhaust fan point /call bell point with 1.5 Sq.mm FRLS P.V.C insulated copper conductor single core cable in surface / recessed medium class PVC conduit , with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm .FRLS PVC insulated copper conductor single core cable etc. as required. a) Short point upto 3.00 metre length Each 100.0 914.62 91461.82 b) Medium point upto 6.00 metre length Each 100.0 1065.1 106510.22 c) Long point upto 10.00 metre length Each 50.0 1321.92 66095.81 |
| 37 | Wiring of item no (1) to 5 pin 6 amps plug point when fixed on the same board. |
| 38 | Wiring for circuit /submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required as standard colour code. a) 2x1.5 sq.mm +1x1.5 sq.mm earth wire (Green colour only) Meter 450.0 209.96 94480.51 b) 2x2.5 sq.mm+1x2.5sq mm earth wire (Green colour only) Meter 900.0 247.8 223022.67 c) 2x4 sq.mm +1x4 sq.mm earth wire (Green colour only) Meter 450.0 300.97 135435.58 |
| 39 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 &15/16 amp modular socket outlet and 15/16 amps modular switch ,connection etc.as required. |
| 40 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 41 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) Modular switch 5 /6amp NO 120.0 92.81 11137.62 b) Modular switch 15/16 amp NO 25.0 140.57 3514.3 c) 3 pin Modular socket outlet 5/6 amp NO 30.0 109.93 3298.03 d) 6 pin Modular socket outlet 15/16 amp NO 25.0 177.52 4437.93 |
| 42 | Supply and laying of following size solid Aluminium conductor upto 10sqmm balance stranded conductor , XLPE insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Aluminium for single core upto 70sqmm balance Aluminium strip, Galvanised for cables up to 2x10sqmm, 3x10sqmm, 4x6sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade armoured U.G. cable laid in air or through existing cable trench/duct/cable tray/HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the dept. (Nicco/Havells/RPG/CCI/ Polycab/ Gloster/Finolex make or equivalent) a) 4 X 16sq.mm cable Meter 200.0 452.38 90476.19 |
| 43 | Supplying with fitting and fixing MCCB incomer and MCB outgoing sheet steel ,phosphatised ,powder painted single door surface mounting vertical TPN MCB DB incorporated with bus bar, Neutral link ,Earth bar upto 125A and din rail etc. fitted on wall with grouting nuts &bolts as reqd. complete with making necessary connection as approved ,specified and directed by the dept. a) 4 way SPN double door Each 5.0 1283.81 6419.05 b) 12 way SPN double door Each 5.0 1928.57 9642.86 |
| 44 | Supplying with fitting and fixing panel mounting open execution 25 kA 415 V 50 Hz 3P MCCB (Ics = Icu, adjustable Ir setting 0.7)(without enclosure) of the following capacity complete with making necessary connection as approved, as specified and directed by the deptt. a) 125 amps, 25 KA, TP MCCB Each 5.0 8034.29 40171.43 |
| 45 | Supplying with fitting and fixing 10KA 240/415V 50Hz MCB of the following capacity complete with necessary connection as specified and directed by the dept. C series a) 6-32Amps, SPN MCB 10 KA Each 15.0 298.1 4471.43 b) 6-32Amps SP MCB Each 30.0 220.0 6600.0 |
| 46 | Supply, installation, testing & commissioning of pre wired, 20 watt LED tube light fitting including complete with all accessories directly on wall/ceiling i/c connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required. |
| 47 | Providing, fixing & testing of following lamps, fixing on existing fittings complete as required. a) 9-10 watt LED Bulb Each 40.0 161.92 6476.8 |
| 48 | Supplying and fixing of batten holder / Angle Holder including connection as approved by Dept. As required (Without lamp) |
| 49 | Supplying including fitting and fixing of following A.C. ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections as approved by the department as required complete and as directed by the department (Without regulator) a) Standard model 1400mm Sweep Each 25.0 1910.48 47761.9 |
| 50 | Supplying, fitting and fixing of two module stepped type Electronic fan regulator on the existing modular plates with box including connection but excluding modular plate etc. as required. |
| 51 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 52 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required. Total amount exclusive of GST = Rs. 1153527.26 Total amount inclusive of GST @18%= Rs. 1361163.35 Name of work: Hiring of services for Electrification works for facility creation at Central Store, ONGC Sivasagar SL ITEM DESCRIPTION UNIT QTY Rate exclusive of GST Total amount exclusive of GST (Rs.) (Rs.) (A) (E) (F) |
| 53 | Wiring for drawing sub main line with 2 x 1.5 Sq. mm PVC insulated single core unsheathed industrial cable FR conforming to IS 694:1990 copper conductor for voltage grade upto 1100 V in surface flat 19 mm ISI marked casing n capping system, including connection as required. |
| 54 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR kabel or equivalent make as approved by the Dept.) in surface flat ISI Marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Dept.)system including earth continuity. a With 2X2.5 sq mm cable + earth continuity with 1X 1.5 sq mm in flat 19 mm ISI marked casing 'n' capping system Mtr 300.0 139.05 41714.29 b With 2X4 sq mm cable + earth continuity with 1X 2 sq mm in flat 19 mm ISI marked casing 'n' capping system Mtr 900.0 182.86 164571.43 |
| 55 | Supplying and fixing following modules, GI/PVC box along with modular base & cover plate for modular switches in recess etc. as required a) 12 Module Each 30.0 492.9 14787.08 b) 8 Module Each 17.0 409.1 6954.7 c) 3 Module Each 28.0 294.66 8250.49 d) 2 Module Each 5.0 268.53 1342.64 |
| 56 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections a 6 A Switch Each 209.0 92.81 19398.02 b 6 A socket Each 42.0 109.93 4617.25 c) 16 A Switch Each 26.0 140.57 3654.87 d) 6 Pin 16 A Socket Each 28.0 177.52 4970.48 |
| 57 | Supplying including fitting and fixing of the following A.C Ceiling fan complete with all accessories like down rod, canopy etc of the following sweeps with making necessary connections as approved by the Dept. As required complete and as directed by the Dept. (Without regulator). 1200 mm sweep(Approved make) |
| 58 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate, switch box including connections |
| 59 | Supplying including fitting and fixing of the following A.C exhaust fan in the existing hole on the wall of following sweeps with making necessary connections as approved by the Dept. As required complete and as directed by the department. Louver type 250 mm sweep |
| 60 | Supplying and fixing modular blanking plate on the existing modular plate & switch box. |
| 61 | Supplying with fitting and fixing sheet steel, phosphatise, powder painted single door surface mounting MCCB enclosure of the following rating MCCB fitted in the wall with grouting nuts & bolts as reqd. complete with making necessary connections as approved, specified and directed by the dept. for 160 A 4P MCCB |
| 62 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. a) 100 A, 30 KA, FP MCCB |
| 63 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recessed, complete with tinned copper bus bar, neutral bus bar, din bar, interconnections, powder painted including earthing etc. as required(But without MCB/ RCCB/ Isolator). a 4 way (4+12) Each 3.0 3686.41 11059.22 |
| 64 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 16 way, Double Door |
| 65 | Supplying with fitting and fixing TPN 10 KA 240/415 V 50 Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the dept. C series a 63 A Each 4.0 1745.71 6982.86 |
| 66 | Supplying and fixing 32 amps rating, 240V/415 Volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a Single Pole Each 34.0 230.68 7843.19 |
| 67 | Supplying with fitting and fixing of Single phase Modular Motor Starter Switch of the following specification complete including making necessary connection as specified and directed by the dept. Overload Relay Range 16-25 Amps in 3 Module |
| 68 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia. including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 69 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required. |
| 70 | Supplying and fixing single pole blanking plate in the existing MCB DB complete as required. |
| 71 | Supply & Installation of 20 W LED Batten tubelight (System lumen efficacy ≥105 <120 lm/Watt) Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures asper BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 72 | Supply & Installation of 36 W LED recessed Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg. centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105<120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 73 | Supplying and drawing of weather proof aluminium conductor cable of following size as directed and specified by the deptt. 4.00 Sq mm twin core |
| 74 | Supplying and laying of following size solid Al conductor upto 10 sq mm balance stranded conductor, XLPE insulated, cores laid up, PVC tape inner sheathed, galvanised steel armour, extruded PVBC type ST2 sheathed, 1100 V grade as per IS 7908(Part 1) 1988 laid in air or through existing cable tray including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. 25 Sq mm 4 Core armoured cable (To be installed for supplying power to the sheds) |
| 75 | Providing and fixing following dia G.I pipe in ground complete with G.I fittings including trenching and refilling etc as required. Total amount exclusive of GST = Rs. 1100168.41 Total amount inclusive of GST @18% = Rs. 1298199.9 S No. Notes |
| 76 | Bidder must quote their rates, as per BOQ. Bidder shall quote percentage above, below or at par with ONGC estimate inclusive of GST. Bid shall be evaluated based on Quoted Rate by bidder which is automatically generated by BOQ. |
| 77 | The bidder shall ensure that while filling the Price Bid, the following details are mandatorily indicated without fail The Service Accounting Code (SAC) relevant to the services being quoted. |
| 78 | Bidders are required to ascertain themselves, the prevailing rates of goods & service tax and all other taxes and duties as applicable (along with rates of all related levies viz. Surcharges, Cess, etc.) on the scheduled date of submission of Price Bids/ revised Price Bids (if any) and ONGC would not undertake any responsibility whatsoever in this regard. |
| 79 | Based on the total amount quoted by the successful bidder in BOQ above or below or at par the estimate, item wise rates indicated below (“Sheet 2 to 5 Schedule of item-wise estimate rates”) will be adjusted upwards or downwards in the same ratio. These rates will be frozen for contract period and executed quantities during any period will be payable on the basis of these frozen rates. |
| 80 | The successful bidder shall be required to attend to and execute the works promptly and fully in accordance with the complete scope of work stipulated in the tender documents, without claiming or being entitled to any extra cost or additional payment from ONGC beyond the quoted rates. |
| 81 | For Bidder desiring to quote At Par to ONGC’s Estimate has to select “At Par” from Drop Down and type 0.00% in the column. Declaration by the Bidder |
| 82 | I/We have understood the scope and specifications of the work. |
| 83 | Bidder’s total quoted amount is inclusive of all taxes and duties (GST, Cess etc.) and nothing extra on this account shall be admissible to them. |
| 84 | I/We shall attend to the works promptly as per the scope of work without extra cost to ONGC. |
| 85 | Bidder to note that the bid will be evaluated on gross total amount quoted by bidder. |