| 1 | Sub-Head :-Underground Tank |
| 2 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a leadof 50m. |
| 3 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete |
| 4 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:a) Foundations and plinth |
| 5 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 6 | Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floortwo level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in :a) 1 : 1.5 : 3 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size) |
| 7 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete. |
| 8 | a)Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 9 | b)Suspended floors, |
| 10 | Reinforcement of RCC work including bending, binding and placing in position complete.b) Tar/TMT Steel |
| 11 | 20 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 12 | Neat cement punning. |
| 13 | Add Carriage |
| 14 | SH: Transformer [150 KVA] |
| 15 | 150 KVA , 11/0.433 KV DT SS = 1 No. |
| 16 | LT line 95 Sq mm = 0.3 Km |
| 17 | DT Security Fencing = 1 No. |
| 18 | SH: Internal Electrification |
| 19 | WIRING |
| 20 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 21 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 22 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 23 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 24 | 2 X 4 sq. mm +1 X 4 sq. mm earth wire |
| 25 | 2 X6 sq. mm + 1 X 6 sq. mm earth wire |
| 26 | 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire |
| 27 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 28 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 29 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 30 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 31 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 32 | 25 mm |
| 33 | 32 mm |
| 34 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 35 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 36 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 37 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 38 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 39 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as reqd. |
| 40 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mm X 75mm) |
| 41 | DISTRIBUTION BOARDS |
| 42 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)12 way (4 + 36), Double door |
| 43 | Supplying and fixing 5A to 32A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 44 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 45 | Supplying and fixing 40 A to 63 A rating, 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 46 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 47 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 12 way, Double door TPN MCBDB |
| 48 | Supplying and fixing of 160A Four Pole MCCB, 415 V, Breaking capacity of 16 kA (Ics= 100%Icu), Compact sized Din mountable, snap fitted Moulded Case Circuit Breaker (MCCB) with inbuilt adjustable Overload settings, conforming to IS/IEC: 60947-2 and IEC 60947-2, in the Enclosure complete with connections, testing and commissioning etc. as required. |
| 49 | SUPPLY OF LIGHT FIXTURES AND FANS |
| 50 | Note:-The model numbers specified below are only for references for Shape of the product requirement. The product shall supplied, must match the technical specifications. The technical data sheets shall be arranged before the material dispatch and got approved from engineer-in- charge.Supply of 20W 1200mm LED fitting batten light. |
| 51 | Supply of 12W round surface sleek LED fitting . |
| 52 | INSTALLATIONS OF LIGHT FIXTURES AND FANS |
| 53 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 54 | EARTHING SYSTEM |
| 55 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 56 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 57 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 58 | SH: Gate |
| 59 | Earth work in excavation in foundation and trenches etc. in all kinds of soil containing 50% or more of shingle or small size boulders upto 30cm size , saturated soil and rock), lift upto 1.5 m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 60 | Providing and laying cement concrete 1:4:8 (1 cement:4 course sand: 8 graded stone, aggregate 40mm nominal excluding the cost of centering and shuttering |
| 61 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel bar |
| 62 | Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete |
| 63 | b) Column, pillars, posts and struts etc. |
| 64 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 65 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 ement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring,shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 66 | 20 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 67 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 68 | Steel work welded in built up sections/framed work, including cutting, hoisting and fixing in position and applying priming coat of approved steel primer using structural steel etc as requiredb)In gratings, frames ,guard bar,ladder , railings , brackets,gates and similar works |
| 69 | Welding by electric plant |
| 70 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 71 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 72 | Add Carriage charge |
| 73 | SH: Renovation |
| 74 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement.a) 40 mm thick |
| 75 | Cement plaster skirting (up to 30 cm height) with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, including rounding of junctions with floor.b) 21 mm thick |
| 76 | Removing old paint or polish with paint remover of approved brand and manufacture and preparing surface. |
| 77 | Removing whitewash or colourwash by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc complete. |
| 78 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 79 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 80 | Interior Walls : Finishing walls with water proofing cement paint of required shade :a) New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 81 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
| 82 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary aluminium butt hinges with necessary screws.a) 38 mm thick best available local wood, class - B I |
| 83 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 84 | Providing and fixing iron pressed butt hinges bright finished with necessary screws etc complete.a) 125 x 65 x 2.12 mm |
| 85 | Providing and fixing MS sliding door bolts, bright finished or and black enamelled with nuts and screws etc complete.a) 300 x 16 mm |
| 86 | Providing and fixing MS tower bolts (barrel type) with necessary screws etc complete.a) 250 x 10 mm |
| 87 | Providing and fixing MS door latch with necessary screws etc complete.a) 300 x 20 x 6 mm |
| 88 | Providing and fixing MS handles with necessary screws etc complete.a) 125 mm |
| 89 | Supplying and fixing glass panes with wooden fillets including removal of broken glass panes and old wooden fillets wherever necessary.b) Glass panes 3 mm thick |
| 90 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.a) Long Pan patten WC Pan |
| 91 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) One urinal basin with 5 Litres CI automatic flushing cistern |
| 92 | Add for Carriages Please Enable Macros to View BoQ information |