| 1 | Earth work in excavation in foundation trenches in Hard soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance up to 50 M. including all lifts, leveling, ramming the foundation trenches, removing roots of trees,, shrubs all complete as per approved design, building specification and direction of E/I. Extra for earthwork in herd soil es per specificatlon and directian of E/I(Vide cleseitfioetion of soil item_B) |
| 2 | Filling in foundation trenches and plenth in layers not exceeding 150 mm. thick well watered ,rammed ,fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume). |
| 3 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I. |
| 4 | Providing coarse clean sand in filling in foundation trenches or in plinth & floor including ramming & watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
| 5 | Providing and laying in position cement concrete of specified grade |excluding the cost of centering and shutfering All work up to plinth level:1:2:4 (1 cement: 2 coarse sand (zone-1) :4 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in positionspecified grade of reinforaed cement concrete, excluding the cost of centering, shutterhe. finishing and reinforcement- All work upto plinth level. 1.5:3 (1 cement: 1.5 course sand (zone-1): 3 graded stone geregate 20 mm nominal size) |
| 7 | Reinforded cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:15:3 cement: 1.5 coarsesand(zone-l):3 graded stone aggregate 20 mm nominal size). |
| 8 | Reinforced cement concrete work in wals (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets column pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering& finishing and reinforcement : 1:1.5:3 cement: 1.5 coarse sand (zone-l):3 graded stone ag8regate 20 mmnominalsize) |
| 9 | Centring and shuttering including strutting, propping etc. and removal of form for foundation, footings, bases of columns etc. for mass concrete. |
| 10 | Centring and shuttering including strutting, propping etc. and removal of form for lintel, beams, plinth beams, griders, bressumers and contilevers. |
| 11 | Centring and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers, abutments, posts and struts |
| 12 | Providing TOR Steel reinforcement of 10mm ,12mm ,& 16mm. dia bars as per apporoved design and drawing excluding carrige of bars to work site ,cutting ,bending , and bending with annealed wire with cost of wire , removal of rust , placing the rods in position all cpomplete as per building specification and direction of E/I . |
| 13 | TMTC-500 8mm dia |
| 14 | TMTC-500 10mm dia |
| 15 | TMTC-500 12mm dia |
| 16 | TMT-500 16mm dia |
| 17 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 18 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 19 | Providing and fixing in position factory made non asbestos fibre reinforced aerated cement sandwich wall/roof/floor light weight solid core panels made of light weight cement concrete core composed of OPC cement, pulverized flyash, quick lime, cotton pulp & Gypsum in mortar state mixed with aeration agent in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board conforming to IS 14862:2000. These solid wall panels are installed using Galvanized iron steel tracks/C channel of 1mm thick of required sizes as recommended by manufacturer’s and fixed to floor and RCC soffit in plumb to each other with steel screw/fasteners. The panel shall be fixed vertically with tongue & groove joint with cement based polymer modified jointing compound. The exposed surface finished with fibre mesh/glass fibre tape with polymer based jointing compound having superior flexibility. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in- Charge (Cost of all the material is included except “tracks/C channel” which will be paid separately).Non load bearing panels 50 mm thick of required size (minimum 4mm thick fibre cement board Type B, Category III as per IS: 14862:2000 on both faces ) |
| 20 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600mmto formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge.With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles |
| 21 | Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. (iv) 600X600 mm size |
| 22 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 45 x 70 mm |
| 23 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately30 mm thick |
| 24 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 25 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 26 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness. |
| 27 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness. |
| 28 | Providing & fixing Fan hook of 16 mm. dia. M.S. bar 1 Mtr. Long bent to required size and shape, placed in position and fixed in Truss Frame / RCC Slab / beam at the time of casting all complete as per building specification and direction of E/I. (Where materials is not supplied by deptt.) |
| 29 | Carriage of Materials |
| 30 | Bricks =10 km(7+3) |
| 31 | Sand=20 km(18+2) |
| 32 | Stone chips =25 km |
| 33 | Point Wiring in PVC Conduit, with Modular type Switch:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. |
| 34 | Group C |
| 35 | Twin control Point Wiring in PVC Conduit, with Modular type Switch:- |
| 36 | Wiring for twin control light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with 2 way modular type switch, modular plate, suitable size of GI box etc as required. |
| 37 | S/F Ceiling Rose :-Supplying and fixing 2pin 5 amp ceiling rose on the existing junction box/wooden block including connection as required etc. |
| 38 | S/F Modular type electronic fan regulator :- |
| 39 | Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 40 | Supply, fitting, fixing and testing of 1200mm Sweep, double ball-bearing, 2 canopy ceiling fan including connection with 1.5 sq mm copper wire, down rod all accessories as required. |
| 41 | S.I.T.C of following rating surface mounted LED tube lightfitting suitable for 230V 50Hz, single phase supply etc. compete as required. |
| 42 | 20w/22w LED tube |
| 43 | Recess Mountting LED Round Down Light (12w) |
| 44 | 12watt |
| 45 | HOLDER |
| 46 | 10 Watt LED Bulb |
| 47 | S.I.T.C of following rating LED post top lamp made in die cast aluminium housing with decorative claer/opal acrylic diffuser on existing pipe including connection with 1.5sq.mm. copper conductor etc all complete as required. |
| 48 | 45w LED Post top lamp opel |
| 49 | 12\\" (300mm) Exhaust fan |
| 50 | Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of he above fan making good the damage, connection, testing, commisionig etc as required. |
| 51 | Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required. |
| 52 | S/F light plug point with modular type accessories :- |
| 53 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 54 | S/F 20amps SPN MCB industrial Socket:- |
| 55 | Supplying and fixing 20 amps 240V, SPN industrial socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP MCB insheet steel enclosure on surace or in recess with chained metal cover for the socket outlet and complete with connections, testing & commissioning etc. |
| 56 | S/F Modular boxes, base & cover plate :- |
| 57 | Supplying and fixing following size/ modules G.I. box along with modular base & cover plate for modular switches in recess etc as required. |
| 58 | 4/5 module (78mm x 140mm x 50mm) |
| 59 | 8 module (78mm x 230mm x 60mm) |
| 60 | S/F Modular type blanking plate :- |
| 61 | Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required. |
| 62 | Copper earth pipe electrode :- |
| 63 | Earthing with G.I. earth pipe 4.5mtr. long 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required. |
| 64 | P/F 25mm x 5mm copper earth strip in surface/ recess :- |
| 65 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc., as required. |
| 66 | S/L 25 mm x 6 mm G.I. earth strip in ground :- |
| 67 | Supplying and laying 25 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including soldering etc. |
| 68 | S/F T.P. MCB DB:- |
| 69 | Supplying and fixing following way three pole & neutral ,sheet steel, MCB distribution board, 415 volts, onsurface /recess, complete with tinned copper bus bar, neutral bus-bar, earthbar ,dinbar, interconnections, powder painted including earthing etc. as required. |
| 70 | 4 Way (4 + 12), Double Door, Horizontal type |
| 71 | 6 Way (4+18) Double Door, Horizontal type |
| 72 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit. |
| 73 | 4R X 4 sq. mm + 2R x 4 sq.mm Earth Wire |
| 74 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit. |
| 75 | 2R X 4 sq. mm + 1R x 4 sq.mm Earth Wire (Sockets) |
| 76 | 2R X 2.5 sq. mm + 1R x 2.5 sq.mm Earth Wire (Switch Boards) |
| 77 | Supply of following sizes and core PVC/XLPE insulated, PVC sheathed armoured electrical cable with aluminium conductor for working voltage upto 1.1 KV etc as required. |
| 78 | 3c x 95 sq.mm |
| 79 | 1.5 TR 5 STAR SPLIT A.C. (INVERTER TYPE) IS -1391 PART-1CATEGORY \\"A\\" DAIKIN, HITACHI, LG, VOLTASOR EQUAL |
| 80 | Copper Tube Of Size1/2\\" for split ac unit 1/1.5/2/3 tr Capacity including nitride rubber installation |
| 81 | 5 kva wall mounted automatic voltage stabilizer from range 140v to 280 v |
| 82 | Drain piipe for AC |
| 83 | Outdoor Stand For 1.5 Tr Split AC |
| 84 | Oil Filled Room Heater with 9 fin having over heating protection and minimum 3 heating position |
| 85 | Stainless SteelRectangular Dining Table withC3431E Round fixed Chair |
| 86 | Stainless SteelRectangular Dining Table withC3431E Square fixed Chair |
| 87 | GODREJ INTERIO RectangularCafeteria Chair Without Armrest |
| 88 | RFROYALZ--ROYAL FURNISHERSRectangular Cafeteria ChairWithout Armrest |
| 89 | Wood Traditional Dining Tables |
| 90 | Stone and Marble Modern Dining Tables |
| 91 | Add 18 % GST (in Basic Rate must fill 12) |
| 92 | Add 1% Labour Cess (in Basic Rate must fill 1) Please Enable Macros to View BoQ information |