| 1 | Description of work |
| 2 | 12 mm thick plaster with Cement mortar over brick work minimum thickness not to be less than 3/8\\" (10 mm) thick including supply of all materials, labour and T&P etc. required for proper completion of the work. cement and coarse sand Mortar in 1:3 si no 583 |
| 3 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete dsr no 11.41.2 |
| 4 | Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 5 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10sqm.). SI 13.46.1 |
| 6 | Painting two coat over priming coat (but including cost of proming coat) on wood or steal and other metal surface with superior senthetic enamel paint of standered make brushing to give an even shade and finished and including cleaning the surface all durt dust and other foreing metter sand preparing and stripping including cost matter and scoured with wire brushes fine steal/wood scrappers sand preparing and knotting including coat of all and supply of all materials, labour and T&P etc. required for proper completion of the work. [S.I. No. New 1+2+3 ch-15] |
| 7 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.8.2.2 Granite of any colour and shade |
| 8 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : dsr no 11.19.1 |
| 9 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.12.41.2 110 mm diameter |
| 10 | Supplying and fixing rolling shutters of approved make of 80x125 mm (3 x 3½\\") gauge cold rolled M.S laths inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets side guides and arrangement for inside and outside locking with push and pull operations complete but excluding the cost of top cover and spring. |
| 11 | Providing and fixing 27.5 cm. long wire spring grade no. 2 for rolling shutters. Si no 521 |
| 12 | Providing and fixing top cover for rolling shutters. 18 guage si no 522 |
| 13 | Providing & fixing ball bearing for rolling shutters si no 523 |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 15 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 18.7.1 15 mm nominal outer dia Pipes |
| 16 | 18.7.2 20 mm nominal outer dia Pipes |
| 17 | 18.7.3 25 mm nominal outer dia Pipes |
| 18 | 18.7.4 32 mm nominal outer dia Pipes |
| 19 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressureequalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specificationand drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as perthe approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. dsr no 8.32 |
| 20 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete. dsr 8.31 |
| 21 | Mild steel or iron work of small size and sections such as holding down bolts, hold fast, tie roads, gratings etc. (when not included in an over all rates) wrought to required form, including of supply of steel, boalts nuts and wastage etc. and there fixing required for proper completion of work. 503 |
| 22 | Add Internal Electrification And appliencce |
| 23 | Add 18% GST Please Enable Macros to View BoQ information |