| Sl. No. | Item Description |
| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead For thickness of tiles 10 mm to 25 mm |
| 2 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.31 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 3 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm |
| 4 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm |
| 5 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick |
| 6 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 7 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 8 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1cement: 4 coarse sand) |
| 9 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete. |
| 10 | Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) kg/10sqm) |
| 11 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 13 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 14 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :13.621 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 15 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.(dismantling of mosaic floor) |
| 16 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 17 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate |
| 18 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area 3 sq. metres and below |
| 19 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area beyond 3 sq. metres |
| 20 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40x40x5 mm, joints mitred and welded by angle iron 40x40x5 mm or 40x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. Providing & fixing of hold fast for chaukhats of doors and windows. |
| 21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete fixed to steel window by welding (Window Grill) |
| 22 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (Z-Section) |
| 23 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 24 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 25 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 26 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 27 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (300x16mm) |
| 28 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (250x10mm) |
| 29 | Providing and fixing ISI marked oxidised M.S. handles conforming to 1S:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 125mm) |
| 30 | Demolishing mud phaska in terracing and disposal of material within 50metres lead. |
| 31 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting ofapplying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sgqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sgm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. For the purpose of measurement the entire treated surface will be measured. |
| 32 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate |
| 33 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cablein surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 34 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Power plug wiring in PVC conduit (4x4 sq.mm.) |
| 35 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 36 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 37 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 38 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 39 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 X 1.5 sq. mm |
| 40 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 250 mm X 300 mm X 60 mm deep |
| 41 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 42 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch |
| 43 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 44 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 6 pin 15/16 A socket outlet |
| 45 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 46 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm) |
| 47 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 48 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 49 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 50 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 51 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 52 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 53 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 54 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 55 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 56 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 57 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm |
| 58 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 59 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 60 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.63 Amp Four Pole |
| 61 | Supplying and fixing of 63 Amp Four Pole MCB (10 KA) C CURVE |
| 62 | Supply & laying of aluminium conducter, PVC insulated amoured, served, sheeted cable 1100 volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamp etc. of suitable size as per direction of Engineer-in-charge. complete in all respect the armouring of the cable shall be properly connected with the earth conductor by clamp etc. 70.0 sq Mm*3.50 core. |
| 63 | Supply and projection of factrory and wired metal wired metal clad dust and vermin proof mountingn. M.S channel Base with bottan and top cable entires Electrical contral panel with Tpn MCCB's(four pole 36Ka with thermal magnatic release)Switches complete and insturment chamber etc. complete in all respects. The instrument chamber shall be separate and shall complate of flush type digital metering system for phase to phase voltage. current and other paraments (Kva.P.f.K.W etc.)in each phase with toche type selector switch for diffrent reading instruments fuses current transformer etc. the panel Board shall have suitable capacity electrolytic aluminum busbars as per is 8623 or above insulated with heat shrink sleeving and mounted on the sides. the MCCB'S shall be completed withsuitable cable end boxes. Compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as Amp and above well be provided with Ammetre. The panel board shall be fabricated with CRCA sheet with Ammetre. the panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6MM /2MM cubicle type switch shall be L/T or Schnieder of equvalent make. incoming 400 AMP , TPN-1 No. Outgoing 200 Amp. TPN-1 Nos, 100 Amp. TPN-2 Nos. & 63 Amp. TPN-1 Nos. CAT B. Cubicle Type |
| 64 | Supply and fixing of 16 gauge MS durm with louvers duly painted including making hole in the wall for exhaust fan and finishing property complete in all respects. |
| 65 | Supply and fixing of recess / surface mounting round 15 to 18 watt cut out min 150 mm, height min 40 mm, LED down lighter having with heat sink, diffuser die cast aluminium housing with heat sink, diffuser/reflector and driver set, suitable for 24 Hr. continuous operation, complete in all respect. 100 lm/W, PF>0.95, THD<10% at full load, CRI>80, with 3 years warranty. |
| 66 | Supply and Fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing withextended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. Cat AAA |
| 67 | Supply and fixing of LED tube light with batten suitable for up 1 x 22 watt LED tube light fitting including tube on surface complete in all respect CAT - AAA |
| 68 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 watt. Confirming to IP 65 protection complete in all respect. |
| 69 | Supply and fixing of 200 Amp four pole change over switch on 50 mm x 50 mm x 6 mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of engineer in charge. |
| 70 | S&L of 1800 mm x 900 mm x 12 mm thick chequred rubber matting of tested quality |
| 71 | Supply and burring of Safe Earthing Electrode T-19 ( Hot Dip Galvanised) , Length up to 3000 mm , Outer GI pipe of 16 SWG and inner with crystalline conductive misture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivty with good mixture of retaining capacity and one earthing lead of 25mm x 3 mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D. & C.P.R.I. Certified. |
| 72 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 73 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standard pattern including cutting & making good the walls wherever required.a) Flat back wash Basin size 550x400 mm with single 15mm C.P. brass pillar tap. |
| 74 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.a) 32mm dia |
| 75 | Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. |
| 76 | Providing & fixing soil, waste and vent pipes.a) 100mm dia centrifugally cast iron S & S pipe. |
| 77 | Providing & fixing soil, waste and vent pipes.b) 75mm dia centrifugally cast iron S & S pipe. |
| 78 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fitting of diameters.a) 100mm |
| 79 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size). Including cost of cutting holes & making good the walls etc.a) for 100mm dia pipe. |
| 80 | Providing & fixing cast iron coller.a) 100mm dia. |
| 81 | Providing & fixing cast iron coller.b) 75mm dia. |
| 82 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm diameter |
| 83 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.a) 110mm |
| 84 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc.(internal work)a)Exposed on wall 25mm dia nominal bore (medium duty) |
| 85 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc.(internal work)a)Exposed on wall b) 32mm dia nominal bore (medium duty) |
| 86 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.a) 15mm dia nominal bore |
| 87 | Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall.b) 20mm dia nominal bore |
| 88 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.a) 15mm dia nominal bore. |
| 89 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.b) 20mm dia nominal bore. |
| 90 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.c) 25mm dia nominal bore. |
| 91 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.d) 32mm dia nominal bore. |
| 92 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.a) 15mm nominal bore |
| 93 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore |
| 94 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931a) 15mm nominal bore |
| 95 | Providing and fixing ball valve (brass) of approved quality complete. (High or low pressure with plastic floats).a) 25mm. Nominal bore |
| 96 | Providing and fixing gun metal gate valve with wheel of approved quality.a) 25mm dia nominal bore |
| 97 | Providing and fixing gun metal gate valve with wheel of approved qualityb) 32mm dia nominal bore |
| 98 | Providing and fixing gun metal gate valve with wheel of approved qualityc) 40mm dia nominal bore |
| 99 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Capacity 11000 litre |
| 100 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.a) 100mm diameter |
| 101 | Providing, laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.b) 150mm diameter |
| 102 | Providing and fixing square mouth S.W. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with bricks of class M-150 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design.a) 150 x 100 mm. size P type |
| 103 | Constructing brick masonry manhole with class bricks M-150 in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design.a) Inside size 90x80 cm & 45 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg.With M-150 Bricks |
| 104 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 105 | Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories forunplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm bend |
| 106 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 107 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 108 | Excavating trenches in all kind of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.up to 1.50 m depthPipes 80 mm to 300 mm diameter |
| 109 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :a) 150mm diameter |
| 110 | Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all around S.W. Pipes including bed concrete as per standard design.150 mm diameter S.W.Pipe |
| 111 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Inside size 90 x 80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg).Extra for depth for manhole with F.P.S. bricks size 90 X 80 cm |
| 112 | .Extra for depth for manhole with F.P.S. bricks size 90 X 80 cm |
| 113 | Making connection of sewer/drain line with existing manhole including breaking into & making good the wall, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1 : 3 (1cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete.For pipes 100 to 230 mm diameter |
| 114 | Providing, fixing G.I. pipes complete with all required G.I. fittings including trenching and refilling etc. (external work) 32 mm. dia nominal bore |
| 115 | Providing, fixing G.I. pipes complete with all required G.I. fittings including trenching and refilling etc. (external work) 50 mm. dia nominal bore |
| 116 | Providing and filling sand of grading zone V or coarser grade all around the G.I. pipes in external work.32 mm. Diameter pipe |
| 117 | Providing and filling sand of grading zone V or coarser grade all around the G.I. pipes in external work.50 mm. Diameter pipe |
| 118 | Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)32 mm nominal bore |
| 119 | Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 50 mm nominal bore |
| 120 | Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 65 mm nominal bore |
| 121 | Constructing brick masonry chamber 600 x 600 x 750 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design |
| 122 | Making connection of G.I. distribution branch with G.I. mains of following size by providing and fixing Tee, including cutting and threading the pipe etc. complete.25 to 40 mm. Nominal bore |
| 123 | Making connection of G.I. distribution branch with G.I. mains of following size by providing and fixing Tee, including cutting and threading the pipe etc. complete.50 to 80 mm. Nominal bore |
| 124 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.0.00 to 1.50 M |
| 125 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.1.50M to 3.0 M |
| 126 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 127 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (M-20) (1 cement : 1.5 coarse sand derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources) |
| 128 | Brick work with c bricks of class designation 15 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 129 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 130 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 131 | 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) |
| 132 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729 |
| 133 | Making soak-pit 2.5 m. diameter and 3 m. deep with 45 x 45cm dry brick honey comb shaft with F.P.S bricks and SW drain pipe complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 134 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) |
| 135 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - :1:1.5:3 (1 Cement: 1% coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 136 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge.Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads /pavements all complete as per direction of the Engineer-in-Charge.Using grade 'A' sealing compound. |
| 137 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern |
| 138 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way Double door |
| 139 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 4 way (4 + 12), Double door |
| 140 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 8 way (4 + 24), Double door |
| 141 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps SP MCB |
| 142 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps DP MCB |
| 143 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps TP MCB |
| 144 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 amps TP MCB |
| 145 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps 4P MCB |
| 146 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 amps 4P MCB |
| 147 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required.25 amps |
| 148 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required.40 amps |
| 149 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 150 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 151 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 152 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral |
| 153 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 154 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 155 | Main LT Panel ,Incoming : One (1) No 320 Amp. 4P MCCB of 25KA Breaking capacity One (1) No 320 Amp. 4P ATS,Metering : 1 Set of CT's one of 320/ 5Amp ratio for Multifunction Meter 1 Set of Phase Indication Lamp. Bus Bar : One (1) No. 400 Amp. FP aluminimum bus bar of suitable length.Outgoing : Phase indication lamps on each outgoing to be provided.200 Amps FP MCCB of 25KA - 2 No,125 Amps FP MCCB of 25KA - 2 No,100 Amps FP MCCB of 25KA - 1 No,40 Amps FP MCCB of 25KA - 2 No,2 No. Space for Spare,Panel described as above |
| 156 | GROUND FLOOR PANEL ,Incoming : One (1) No 200 Amp. 4P MCCB of 25 KA Breaking capacity Metering : One (1) No. Sets Multifunction Meter each incoming One (1) No. of Phase Indication Lamp each incoming Bus Bar : One (1) No. 250 Amp.TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 40 Amps FP MCB of 10KA - 2 No,32 Amps FP MCB of 10KA - 2 No,25 Amps FP MCB of 10KA - 2 No,40 Amps TP MCB of 10KA - 7 No,63 Amps TP MCB of 10KA - 4 No,2 No. Space for Spare ,Panel described as above. |
| 157 | FIRST FLOOR PANEL Incoming : One (1) No 125 Amp. 4P MCCB of 25 KA Breaking capacity Metering : One (1) No. Sets Multifunction Meter each incoming One (1) No. of Phase Indication Lamp each incoming ,Bus Bar : One (1) No. 150 Amp.TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 25 Amps FP MCB of 10KA - 2 No,40 Amps TP MCB of 10KA - 7 No,63 Amps TP MCB of 10KA - 4 No,2 No. Space for Spare Panel described as above. |
| 158 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 159 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 160 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 161 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 162 | Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Up to 35 sq.mm. |
| 163 | Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq.mm. and up to 95 sq.mm. |
| 164 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Up to 35 sq.mm. |
| 165 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle |
| 166 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp |
| 167 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 168 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 169 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 170 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 150 sq.mm |
| 171 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 70 sq.mm |
| 172 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3.5 x 35 sq.mm |
| 173 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 16 sq.mm |
| 174 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 10 sq.mm |
| 175 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 3 x 6 sq.mm |
| 176 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.2 X 6 sq. mm (19mm) |
| 177 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.3½ X 35 sq. mm (32mm) |
| 178 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.3½ X 70 sq. mm (38mm) |
| 179 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.3½ X 150 sq. mm (50mm) |
| 180 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.4 X 10 sq. mm (25mm) |
| 181 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.4 X 16 sq. mm (28mm) |
| 182 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia |
| 183 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 184 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 185 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 186 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 187 | Supply & fixing of following size (GI RACEWAY) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.100 mm x 40 mm x 1.6mm |
| 188 | Supply & fixing of following size (GI RACEWAY) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.300 mm x 40 mm x 1.6mm |
| 189 | Supply & fixing of following size of Raceway Junction Box made out of GI for electrical, Height adjustable & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification.100 mm x 100 mm x 50mm |
| 190 | Supply & fixing of following size of Raceway Junction Box made out of GI for electrical, Height adjustable & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification.150 mm x 150 mm x 50mm |
| 191 | Supplying, installation, testing & commissioning of 1.5 Ton Split Air conditioning unit (indoor & outdoor units) , 5 star rating with evaporator copper coil & imported refigerant joints with wireless remote controller & supply of Automatic Voltage stablizer, TDR wider range wall mounted, Hi-low cut, ISO-9001 certified:4/5 KVA and including copper refigerent piping of split type indoor and outdoor unit as per site requirement. Complete with placement of outdoor unit including hanging arrangement and including drain pipe as per site requirement, complete in all respects as directed by engineer in charge. |
| 192 | C.C.T.V. WORKS, Supply, Installation, testing and commissioning of Dome Camera (I.P.) Full HD image with a 1/2.7\\" 2 megapixel sensor or full HD 4 MP 20 fps image with a 1/3\\" 4 megapixel sensor. |
| 193 | Providing of 40 Channel NVR |
| 194 | Providing of Hard disk Surveillance 8 TB |
| 195 | Providing of RACK 12 U |
| 196 | Providing of DLink |
| 197 | Providing of LED Screen 50\\" |
| 198 | Providing of patch panel 24 port/fiber |
| 199 | Providing of Sfp Model |
| 200 | Providing of Fiber Cabin |
| 201 | Providing of CAT6 UTP cable 305 mtr |
| 202 | Providing of Online UPS with 30 Min Backup |
| 203 | Providing of HDMI Cable 10 Meter |
| 204 | Supply & Installation of CAT 6A Cable |
| 205 | Providing of Connector RJ-45 |
| 206 | Providing of Cable Laying charges (Per Meter) |
| 207 | Installation Charge of Camera |
| 208 | Fire Extinguishers : Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 209 | Fire Extinguishers : Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 210 | Supply and installation of 2500 Ltr water Tank along with MS structure staging including painting of structure with Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture etc. complete. |
| 211 | Supply, installation, testing & commissioing of 30 KVA UPS in paralleling mode at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet/MODBUS, inbuilt / external isolation transformer as per specification given in the document with following broad features. Including required panel and cables.THD(i) shall be less than 3% in the entire loading range. Input power factor shall be more than 0.95. from 25% to 100% load. UPS shall carry design output at 40 deg. Shall have soft start and hold of for incoming supply. Invertor capability to supply 150% load for 5 sec. Three Phase Input and Three Phase Output. ( Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.) Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. Battery shall be external type with rack and suitable for 30 minute backup on 100% load. UPS shall be compatible for minimum 2 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS. |
| 212 | Supply, Installation testing & commissioning of 6,200 ANSI lumens 3-chip 3LCD projector having resolution Full HD 1080p, Contrast ratio 2,500,000:1, Horizontal and Vertical Keystone Correction ±30°, Should have 2 or more HDMI, 2 or more VGA, 1 or more HDBaseT, 2 or more Audio 3.5mm in, 2x USB, 1x Ethernet (RJ-45); Outputs: 1x HDMI out, 1x Audio 3.5mm jack out, Control: RS-232, LAN (RJ-45) Ethernet(10/100 RJ-45), Should have Throw distance of Projector from Screen: 5.85 Mtrs - 9.4 Mtrs or better complete with all standard accessories. |
| 213 | Supply, Installation, Testing & Commissioning of Mounting/ Hanging arrangements for the above given projector complete with standard accessories as required. |
| 214 | Providing and fixing 450X900 powder coated 4-6mm MS sheet and 25mm Corian Signage at desired locations with letters (in english & hindi) and illustrations - etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge |
| 215 | Providing and fixing 200X450powder coated 2-4mm MS Signage at desired locations with letters (in english & hindi) and illustrations - etched, through cut, infilled or painted as per the design approved from Architect in charge, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge. |
| 216 | Providing and Fixing 3 mm Acrylic Laser Cut Letter embossing 50 mm with 4 mm Sun board female channel with ribbon LED light with 3 mm aluminum composite panel with 40 mmx40 mm square MS pipe frame inside the ACP sheet. Top Big Letter Size 26\\" with vowel diacritic and bottom small letter 16\\" with vowel diacritic. Board size 24 feetx5 feet with transportation and installation complete in all respect as per direction of Engineer incharge. |
| 217 | DATA / NETWORKING SYSTEM S/F of Surface mount box with I/O Cat 6 and UTP jack D-Link complete in all respect Make Dlink/Amp |
| 218 | S/I of Patch cord CAT6 UTP Make Dlink/Amp |
| 219 | S/I/T/C of 24 port category 6e SL Series patch Panel Make Dlink/Amp with active and passive components,punching, complete in all respect |
| 220 | Supplying, installing, testing and commissioning of 24 10/100/1000BASE-T PoE-plus |
| 221 | Supplying, installing, testing and commissioning of 6 U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. |
| 222 | Mapping of Network Nodes & LAN Diagram |
| 223 | SITC of WIFI Modem suitable to cover atleast 25m distance having compatibility to connect atleast 40-50 devices without any distortion in signal etc as required. |
| 224 | Providing and placing Student Chair including PP moulded seat and back in blue colour, heavy duty MS powder coated frame made duly welded, smooth finish, complete in all respects as per approved sample and direction of Engineer-in-Charge. |
| 225 | Providing and placing Visitor Chair having PP armrest/handle, velvet upholstered seat and net tapestry back, strong MS tubular frame powder coated, sturdy construction, comfortable seating, complete in all respects as per approved design and instructions of Engineer-in-Charge. |
| 226 | Providing and fixing Student/Training Room Chair with PLPB writing pad, powder coated MS pipe frame, seat and back upholstered with fabric tapestry, book tray provided under seat, complete including all fittings, hardware and finishing, as per approved sample and direction of Engineer-in-Charge. |
| 227 | Providing and fixing wooden storage unit made of pre-laminated particle board of approved make and thickness, including shelves, shutters, fittings, edge banding, locking arrangement and all accessories, complete in all respects as per approved drawing and direction of Engineer-in-Charge |
| 228 | Providing and placing three seater sofa with seasoned wooden frame, wooden gold plated legs, upholstered with Asmara fine leatherette tapestry, overall size 2120 mm (L) × 900 mm (D) × 850 mm (H), including cushions, foam, stitching and finishing, complete as per approved sample and direction of Engineer-in-Charge |
| 229 | Providing and fixing computer desk made of pre-laminated particle board of approved thickness, fixed pedestal, overall size 1050 mm (W) × 600 mm (D) × 750 mm (H), including drawer unit, edge banding, hardware fittings and finishing, complete in all respects as per direction of Engineer-in-Charge |
| 230 | Providing and fixing table made of pre-laminated particle board without pop-up box, size 1800 mm (W) × 900 mm (D) × 750 mm (H), including edge banding, supports, fittings and proper finishing, complete in all respects as directed by Engineer-in-Charge |
| 231 | Providing and fixing workstation table with panel based partition system, particle board edge banded top, overall size 4000 mm (W) × 1260 mm (D) × 1200 mm (H), including partitions, supports, fittings, and finishing, complete in all respects as per direction of Engineer-in-Charge Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail