| 1 | WAREHOUSE & PLANT SHEDExcavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 2 | Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means |
| 3 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. |
| 4 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete. |
| 5 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15cm. to 20cm. including watering and compaction etc. complete. |
| 6 | Providing and filling in the foundation with sand of approved quality including watering, compacting etc. complete. (To be executed with prior approval of Superintending Engineer) |
| 7 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate ( Crushed sand VSI Grade finely washed etc) |
| 8 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) |
| 10 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) |
| 11 | Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap / granite /gneiss / quartzite metal for R.C.C. fins of required thickness in position as shown on the drawings or as directed by Engineer-in-charge including steel centering, plywood / steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate ( Crushed sand VSI Grade finely washed etc) |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade finely washed etc) |
| 13 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 14 | Providing dry rubble stone pitching 23 cm (about 9 ) thick including all material, quarry spalls, labour etc. complete. |
| 15 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 16 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 17 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 18 | Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing with hot dip zinc coating including fabricating glazing with plain / obscured glass pans and approved type quality and iron oxidized fixtures and fastening with guard square bars 12 mm 10 cm c/c and oil painting 2 coats etc. complete. |
| 19 | Providing and fixing steel window of various sizes as per detailed drawing without hotdip zink coating, with out ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with gward bars 12mm square at 10 cm c/c.) |
| 20 | Providing and applying white-wash in one coat on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing & brooming down etc. complete. |
| 21 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old & new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. |
| 22 | Providing internal cement plaster 20mm. thick in single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. As directed by Engineer in charge |
| 23 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. As directed by Engineer in charge |
| 24 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. As directed by Engineer in charge |
| 25 | Providing & applying washable oil-bound distemper of approved colour and shade to old & new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. As directed by Engineer in charge |
| 26 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete.As directed by Engineer in charge |
| 27 | Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. As directed by Engineer in charge |
| 28 | Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. As directed by Engineer in charge |
| 29 | Supplying, fabricating, erecting and fixing in position of steel structure at all elevation using fusion welding quality steel E-350 (Fe490) conforming to IS:2062 - 2006. Rate shall include cost cutting, welding, splice plate and packing plates, transporting, straigthening, cleaning, fabricating and erecting in position welding / bolied structural steel work in columns, beams, trusses, purlins, platforms, laders, monorails, staircase, supports, strengthening of steel members etc. at site to line and level, supply of approved bolts / nuts / washers etc. complete as per drawings including painting as per G4 / G5 / G6 before erection and all materials and labour charges etc. complete and including sand blasting & painted with 1 coats of enamel paint (Berger EPILUX SG-HHI 664002) of 35-50 micron each coat with air less spray gun over a coat of zinc chromate primer - 35-50 micron etc complete as shown in drawing as per specificationas and directed by the Engineer in charge / Construction Manager As directed by Engineer in charge |
| 30 | Supplying, fabricating, erecting of cold formed light guage structural steel members conforming to IS:801 hot-dip galvanised to IS:4759-96 including cutting, welding or bolting, splice plates and packing plates, transporting, straightening, cleaning, fabricating and erecting in position As directed by Engineer in charge |
| 31 | Supply and fixing of PPGI sheets of 0.5 mm thick as shown in drawing or as directed by Engineer in charge with all necessary accessories |
| 32 | Supply and fixing of 0.5 mm thick PPGL roof accessores as per drawing or as directed by Engineer in charge |
| 33 | Supplying, fabricating and erecting in position PPGI Eaves Gutter of required size with stop ends, all fixing accessories, drop ends, etc at all elevations levels & heights including aligning, leveling, providing and fixing bolts, nuts, washers, etc conforming to latest specifications including strengthening, cutting, welding, bending to shape, bolting, etc and as directed by Engineer in charge |
| 34 | Providing and fixing of the rain water down take pipes of PPGL the sectional area of rain water down take pipes provided shall be generally at the rate of 1 sqauare cm per 70 to 80 square decimetre of roof area drained. No spout shall be less than 80 mm in diameter. The spacing of spouts shall be arranged to suit the position of openings in the wall including all materials and labour charges etc completed shown in drawing as per specifications and as directed by Engineer in charge |
| 35 | Supply and fixing of turbo ventilator with 610 mm throat, having base ring and top plate in stainless steel of 0.8 mm thick, rotated using twin bearings of SKF - 600122 & 600322 permanently lubricated and sealed. Fixed in FRP base plate of 2 mm thick clear 1.02 mtr wide & 1.70 mtr long. |
| 36 | Supply and fixing 2 mm thick polycarbonate sheets as per drawing and as directed by Engineer in charge |
| 37 | Add Royalty Charges for Sand |
| 38 | Add Royalty Charges for Metal & Murum Add for Material Testing as per Statement |
| 39 | Penetration, Softening Point, Flash & Fire Point, Specific Gravity |
| 40 | Extraction Test.(Bituminous mix) |
| 41 | Viscosity. |
| 42 | Comp. Strength Cube |
| 43 | Crush Metal - Besic Test |
| 44 | Gradation |
| 45 | Comboned Flakiness & Elongation of single metal |
| 46 | Cement Fineness consistency, Setting time, Compressive Strength, Specific Gravity |
| 47 | Sand Fineness Modulus, Silt Content |
| 48 | Water Absorption (Set of 5 Bricks). Comprenssive Strength (Set of 5 Bricks) Effor (Set of 5 Bricks) |
| 49 | Concrete Mix Design (With all Tests on basic materials) |
| 50 | Murum in Plinth Plasticity Index |
| 51 | Compraction Test (Proctor Density) |
| 52 | RUBBLE Crushing Value / Compressive Strength, Water Absorption & Specific Gravity |
| 53 | STEEL Strength Yield stress, ultimate tensile stress, Ablongation, Weight per running meter, Bend / Rebend test. (Set of 3 Bars) UP to |
| 54 | plasticity index for murmum |
| 55 | compaction test |
| 56 | binder content |
| 57 | Penetration, Softening Point, Flash & Fire Point, Specific Gravity |
| 58 | Extraction Test.(Bituminous mix) |
| 59 | Management Strategies and implementation Plan (MSIP) to manage the Envoirmental, Social, Health and Safety (ESHS) risks and ESHS Code of Conduct |
| 60 | ROAD Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area . |
| 61 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) mm Aggregate) |
| 62 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate) |
| 63 | Providing and constructing 75 mm. thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 30% crusher broken metal + 70% Hand broken (by breaking rubble obtained by blasting) heating and spraying the bitumen of specified grade @ 2 Kg/sqm, spreading 12 mm.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing WBM surface. (VG-30 bulk bitumen |
| 64 | Open Graded Premix Surfacing- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( Over MPM Surface) (VG-30 bulk bitumen |
| 65 | Providing bituminous Type A liquid seal coat on bituminous surface including supplying all materials and bitumen of specified grade preparing existing road surface, heating and applying bitumen @ 0.98 KgSqm. by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete. (VG-30 bulk bitumen |
| 66 | Supplying hard murum/ kankar at the road site, including conveying and stacking complete. |
| 67 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete |
| 68 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. |
| 69 | Add for Material Testing as per Statement As directed by Engineer in charge. |
| 70 | ELECTRIFICATIONSupplying, erecting an terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq.mm. aluminium conductor complete erected with glands and lugs, on wall / trusses / pole or laid in provided trench / pipe as per specification |
| 71 | Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1 kV complete as per specification . |
| 72 | Making trench in hard murum / tar road having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1 kV complete as per specification |
| 73 | Supplying & erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole /Bus bars or any other places. as per specification |
| 74 | Supplying & erecting CRCA sheet metal enclosures of 1.2 mm thickness with 10A, 2 pin plug & earth socket and 10A, 3 pin plug top with 10A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame |
| 75 | Point wiring for light / fan / bell in 20mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification |
| 76 | Supplying and erecting 10-12W, 230V integral type LED lamp suitable for B-22/E-27 base |
| 77 | Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 1800 Lumens, min efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f.>0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, life class of 50,000 Hrs. at L70B50, including driver complete with 3 years warranty as per specification |
| 78 | Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6 m in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification |
| 79 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification |
| 80 | Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification |
| 81 | Supplying, erecting & marking DPMCB 6A to 32A, C- series (for motor/power) in provided distribution board as per specification |
| 82 | Supplying, erecting & marking SPMCB 6A to 32A, B- series rated short - circuit breaking capacity (1cm) 10kA in provided distribution board as per specification |
| 83 | Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629-:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. . |
| 84 | Supplying and erecting marine (Waterproof) plyproof 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc complete with compliance to IS 720:2010 |
| 85 | Supplying & erecting triple pole and neutral distribution board (TPNDB) 3 pole / 4 pole MCCB as incomer & outgoing SP SPC (12 poles) of TP MCB of 4 ways (12 poles) with doors, 1.2 thickness, surface/ flush mounted on iron/ GI frame (vertical busbar type) as per specification |
| 86 | Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification |
| 87 | Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification |
| 88 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 89 | Supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq. mm. /2 to 4 core 10 sq. mm. for XLPE armoured cable as per specification |
| 90 | Supplying and erecting Ceiling rose / Batten holder /Slanting holder / hanging cord switch / hanging bell push / pendent holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box. |
| 91 | Point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification |
| 92 | Wiring for plug on board with Switch socket surface / concealed type, copper wiring and earthing and with modular accessories as per specification |
| 93 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole/Bus bars or any other places. as per specification |
| 94 | Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole/Bus bars or any other places. as per specification |
| 95 | Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 96 | Supplying erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board complete. |
| 97 | Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22/E-27 base. |
| 98 | Supplying and erecting IP65 and IK08 and rated UV shielded polycarbonate waterproof and dustproof industrial grade LED fitting (4 feet) max, 36W with high transitivity diffuser with system lumens output of min 4300 lumens, min. efficacy of 120 lumen / W. CR>80, CCT upto 6500K. Beam angle of 120 deg. Ripple<5%, THD<10%, p..f.>0.95, operating range of 120-270V, surge protection of 4 kV. Life class of 50,000 Hrs. at L70B50, IP20 rated, including driver with auto cutoff & auto restart feature at 325V with end caps on PVC lock / wooden board with 3 years warranty. |
| 99 | Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification |
| 100 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size As directed by Engineer in charge. |
| 101 | Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6 m in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification |
| 102 | Supplying and erecting CRCA sheet metal one way enclosures of 1.2 mm thickness suitable for DP MCB / TP MCB / PP MCB / RCCB / RCBO complete erected on angle iron / GI frame As directed by |
| 103 | Supplying erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board complete. |
| 104 | Management Strategies and Implementation Plan (MSIP) to manage the Environmental, Social, Health and Safety (ESHS) risks and ESHS Code of Conduct Please Enable Macros to View BoQ information |