| 1 | A. Civil Works1. Dismantling and DemolishingDemolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:-Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Demolishing brick work including stacking of serviceable material sand disposal of unserviceable materials with all lifts and upto a lead of 50metc. complete as per direction of the Engineer- in-chargeIn cement mortar. |
| 3 | Removing mortar from brick and cleaning bricks including stacking bricks and disposal rubbishwith all lifts and upto a lead of 50 m etc.complete as per direction of the Engineer- in-chargeIn cement mortar. |
| 4 | Takingout doors,windowsandclerestorywindow shutters(steelorwood) including stacking with in 50 metres lead :Of area 3 sqm and below. |
| 5 | Of area beyond 3 sqm. |
| 6 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 7 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 8 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re-plastering or re-pointing including disposal of rubbish to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in-charge. |
| 9 | 2. Repairs to BuildingSCAFFOLDING WORKProviding and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 10 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.Interior Walls |
| 11 | Exterior Walls |
| 12 | 3. Wood Work & PVCProviding wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :Sal Wood |
| 13 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for paneled or paneled and glazed shutters 25 to 40 mm thick.Local Teak Wood 16 mm thick |
| 14 | 4. Flooring Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 15 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 16 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 fine sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 17 | Bitumen CoatProviding and fixing precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, landings, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and polishing etc. all complete as per direction of Engineer-in-charge.In light shade using white cement |
| 18 | Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design etc. all complete as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge. |
| 19 | 5. Finishing WorkFinishing walls with water proofing cement paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats applied @ 3.84 kg/10 sqm |
| 20 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground with all leads and lifts including finishing even and smooth and curing complete as per direction of the Engineer in charge:With cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 21 | Cement concrete flooring 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. all completeetc as per direction of Engineer-in-charge.40 mm thick with 20 mm nominal size stone aggregate |
| 22 | Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).D.P.C. 40 mm thick |
| 23 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specificationNote: [Item 4.12]i) This item should not be considered for payment in case the water proofing materials in the form of liquid is used.ii) For carriage of water proofing material in the form of powder the carriage being paid for cement can be considered.iii) For doing the water proofing work perfectly the required number of cement bags for particular item should be opened and the water proofing compound mixed and the whole quantity of cement in the bag should be perfectly blended with water proofing compound only in such cases this item should be allowed.iv) Normally the contractors mix the compound directly in the mixer and this method is totally defective and will not serve any purpose. |
| 24 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 25 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 26 | Painting WorkExterior WorkApplying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content [Payment shall be made after submission of Test Certificate issued by the Manufacturer].With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 27 | Finishing walls with textured exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm |
| 28 | Interior WorkProviding and applying white lime based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 29 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 30 | Interpretation WorksHistorical paintings, Artifacts, Archival photos, Data collection and exchange of Ideas / datas from local resources / communities / Royal family / etc.Historical Person Canvas Painting, 30x20 in |
| 31 | Polished Sandstone Abstract Marble Stone Artifact (24 inch) |
| 32 | Website Data Scraping Services |
| 33 | Acrylic Modern Art Decorative Canvas Paintings, Handmade |
| 34 | Printed Decorative Wall Painting, For Decoration |
| 35 | Carpeting |
| 36 | Display CasesTry On MIRROR- 55” Floor Standing LED DisplayCONFIGURATION Large Format Display: 55” LED/LCD Screen with full HD resolution of 1920 x 1080 (touch Enabled) Depth Sensing Camera Computer – Core i5 or higher with 4 GB RAM, 320 GB SDD, USB 3.0 |
| 37 | Signage |
| 38 | Silk Curtains Set for each opening |
| 39 | Replica of Royal FurnitureVictorian Antique Furniture |
| 40 | Antique Wooden Furniture, Seating Capacity: 4 Seater |
| 41 | Wooden Dining Chairs |
| 42 | Wooden Teak Royal Diwan |
| 43 | Royal Throne Teak Wood Chair, With Cushion |
| 44 | Wood Brown Antique Furniture |
| 45 | Palatial Italian 19th century Louis XVI style carved and gilt wood grand console with mirror |
| 46 | Antique Furniture |
| 47 | Wooden Royal Round Table with Gold Touch |
| 48 | ELECTRIFICATION WORKSB. LIGHTING AND ELECTRICAL WORKSEarthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 49 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 50 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required |
| 51 | Supplying and fixing of powder coated sheet steel enclosure on surface/recess, suitable for 415 volts MCCB (TP/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required: -12-way TP MCCB outgoing & TP MCCB incomer upto 400 amps: |
| 52 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following rating in the existing MCB DB including connection as required:-6 to 32 amps SP MCB |
| 53 | 50/63 amps FP MCB: - |
| 54 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc casing and capping complete with surface modular switch board with cover plate and modular switch including connection etc as required.Short Point |
| 55 | Medium Point. |
| 56 | Long Point. |
| 57 | Wiring for light/ fan/ exhaust fan/ call bell point with 2x1.5 sq. mm PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amp modular type switch, switch board, cover plate, GI box including necessary connection etc. as required. |
| 58 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.2 X 1.5 sq mm |
| 59 | Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall etc. as required2 X 1.5 + 1 X 1.5 sq mm |
| 60 | 2 X 2.5 + 1 X 1.5 sq mm |
| 61 | 2 X 4 + 1 X 1.5 sq mm |
| 62 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:- 2 x 2.5 sq. mm |
| 63 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required.1-2 module GI switch board: - |
| 64 | 3 module GI switch board: |
| 65 | 8 module GI switch board: |
| 66 | 12 module GI switch board: |
| 67 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required1-2 module GI switch board: - |
| 68 | 3 module GI switch board: - |
| 69 | 8 module GI switch board: - |
| 70 | 12 module GI switch board: - |
| 71 | Supplying and fixing of the following modular accessories including necessary connection etc. as required6/10 amps one way SP switch (1M) :- |
| 72 | 16/20 amps one way SP switch (1M) :- |
| 73 | 32 amps one way DP switch (2M): |
| 74 | 3 pin 6/10 amps socket outlet (2M): |
| 75 | 3/6 pin 16/20 amps socket outlet (2M): |
| 76 | 3/6 pin 25 amps socket outlet (2M): |
| 77 | Blank plate (1M):- |
| 78 | Louvers/opaque type LED foot lamp (4M): |
| 79 | 20/25 amps single phase motor starter switch (2M):- |
| 80 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.19/20 mm |
| 81 | 25 mm |
| 82 | Supply, installation, testing and commissioning DECORATIVE wall light with bulb Type Wall Light Material Metal Wattage 8 W Lighting Color Cool White Operating Voltage 240 V IP Code IP20 Lighting Type Fluorescent Color Temperature 6500K Base Type E27 Style Modern Fixture Color Bronze |
| 83 | Supply, installation, testing and commissioning of IP 20 LED picture Light fixture operating on operating voltage range of 220-240VAC. Power Supply should be integral part of the luminaire and should have >85% Efficacy & CRI >90 with the ability of producing premium color and premium white effect and SDCM<=3. Max power consumption of 23W to generate minimum lumen output of 1900 lumens at 3000K with 1C adaptor, having power factor >=0.9. Beam angle options of narrow beam (12-17 deg), medium beam (22-26 deg), and wide beam (28-32 deg) depending on applications. Pressure Die cast housing & fashion proof optics. Fixture should confirm LM 79 i.e. lumen maintenance of 70% at >50000 burning hours at 25 deg C. Fixture should have adjustable mounting bracket for simple position control from various angles without special tools with pane angle 0 - 320 deg and tilt angle of 0 - 90 deg. The luminaire should have operating temperature range from 0 to 50 deg C. Operating temperature range from -15 deg C to 35 deg C. Luminaire and driver must be BIS Certified and both certificates must be submitted for records. LM79 and LM80 reports must be submitted from a NABL accredited laboratory. |
| 84 | Supply, installation, testing and commissioning of IP 20 Rated Chandelier Choicest crystals with chrome finish in a grand heritage design for a royal feel having dimension of minimum dia 750mm X H 2400 mm; lamp suitable of E14 base with 9 nos of lamps (LED) with capacity of 60W maximum having CCT of 3000K. |
| 85 | Electrical WorkSupplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete shall be made up of die cast power coating housing complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt.26/28 Watt |
| 86 | ABC Fire Extinguisher 4KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve with ABC Powder 90% UL299 FIRE RATING:2A,89B. Withall accessories |
| 87 | CO2 type Fire Extinguisher ISI marked confirming to IS: 15683:2018 Capacity 4.5Kg. INITIAL CHARGE: - Carbon dioxide used in extinguishers shall comply with IS 15222.FIRE RATING:-55B. Complete with Hose Assembly and horn ,locking arrangement, operation manual, bracket with two screw and sleeve |
| 88 | Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1)2 x 6 sq. mm. |
| 89 | 4CX10 sq .mm |
| 90 | 4 x 25 sq. mm. |
| 91 | Supplying and making end termination with brass compression gland and Aluminium lugs for following size armoured Aluminium conductor power cable of 1.1 KV grade as per specification. .2 X6 sq. mm (16 mm) |
| 92 | 4 X10 sq. mm (22 mm) |
| 93 | 4 X 25 sq. mm (25 mm) |
| 94 | Supplying, installation, testing and commissioning of following capacity diesel Generating Set (alternator directly coupled to diesel engine) compete in all respect broadly comprising of following and as per CPCB 2 norms (upto date amended), including following specification. A. Alternator : Self excited, brush less type, of following capacity, 3 phase, 415 volts 50 Hz, 4 pole, AC alternator complete with all accessories.B. Engine : water cooled diesel engine of suitable BHP for rated alternator at 1500 rpm, turbo charged, direct injection type, 4 stroke, 4/6 cylinder including specified size fuel tank of approved design and shape duly calibrated and painted with one coat of primer and two coats of synthetic enamelled paint of approved colour, residential type silencer with exhaust MS pipe (upto 2 metre beyond silenser) duly wrapped with asbestos rope of legging of specified quality and specification.C AMF Panel : Cubical, compartmentalized, AMF panel board with all suitable size power and control contactors, switches, meters and other accessories, internal wiring, connection, inter-connection etc. for trouble free smooth functioning of DG Set complete with battery charger and leads as per specification. D. Base Plate : Common base plate of required size for mounting of engine alternator set fabricated from MS channel and vibration damping arrangement with cushy foot mounting i/c painting etc. as per specification.40 KVA |
| 95 | Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB \\"C\\" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)Short Point |
| 96 | Medium Point.. |
| 97 | Long Point.. |
| 98 | Extra Long Point I |
| 99 | Extra Long Point II |
| 100 | Supplying and fixing TPN and earth, 440 volts, industrial type, socket outlet, enclosed metal plug top along with MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification.32 Amp with “C” curve TP MCB |
| 101 | Supplying and fixing 2 POLE and earth, 240 volts, industrial type, socket outlet, enclosed metal plug top along with SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification.32 Amp with “C” curve MCB |
| 102 | Supplying and installing following size powder coated, perforated M.S. cable trays with perforation not more than 17.5% rigidly suspended from the ceiling with M.S. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc complete as per specification.225 mm width X 50 mm depth X 1.6 mm thickness |
| 103 | Supplying and fixing of following sizes powder coated, perforated, M.S. cable trays bends (horizontal) turning at 900 in same plane with perforation not more than 17.5% rigidly jointed with cable tray etc. complete as per specification.225 mm width X 50 mm depth X 1.6 mm thick |
| 104 | Supplying and fixing of approved make Tower Air Conditioner unit with cooling unit and condensing unit with copper coil including standard length of upto 3 metre of copper piping with insulation etc complete as per specification.3.0 TR |
| 105 | CCTV WORKCCTV WORK: 4 MP Bullet Camera - SITC of 4MP Bullet weather & dust proof IP based Fixed Lens true day/night Camera (IP67 , IK 10) , 1/3” 4MP PS CMOS Image Sensor,H.265 and H.264 triple-stream encoding, WDR(120dB), Day/Night(ICR), Range of 30-50 Mtrs, UL ,CE FCC Certified |
| 106 | 2 MP PTZ Camera - Providing installation testing and commissioning weather & dust proof IP based Dome PTZ (Pan Tilt & Zoom) true day& night camera ,1/2.8” 2MP PS CMOS Image sensor, Max. 50/60fps@1080P,Color: [email protected]; [email protected] (IR on), Powerful 45x (3.95~177.7 mm) Optical and 16x Digital zoom, WDR(120dB), 3D DNR, Day/Night(ICR),Defog, ROI, EIS, AGC, BLC, HLC, Support Starlight Function, Up to 300 presets, auto scan, 8 tour, 5 pattern, auto pan, Tripwire, Intrusion, Abandoned/Missing , Face Detection, Heat Map, IR Range of 200 Mtr., Max 300° /s pan speed, 360° endless pan rotation, Built-in 7/2 alarm in/out, Micro SD card 256GB, IP67, IK10, Support PoE+, UL, CE ,FCC certified |
| 107 | Supply, Installation, Testing and Commissioning of 32 Channel NVR 4 Sata port-Up to 8 TB; 32 Channel IP camera input, Quad Core embedded Processor and LINUX Embedded; 16 POE; Max 200 Mbps incoming & outgoing bandwidth, Smart H.265/ H.264 codec decoding, Upto 8 MP resolution preview and playback, Frame Rate: 1-15 FPS(8 MP); 1-25/30 fps for rest of Resolutions; Support 4 SATA HDDs up to 8 TB each, 2 USB (1 USB3.0,1 USB2.0), 1HDMI /1 VGA simultaneous video output , Two way talk 1Channel Input, 1Channel Output RCA, 1RJ-45port (10/100/1000Mbps), |
| 108 | Supplying, installation, testing and commissioning of 8 Port PoE Switch-10/100/10008 Port with 2 Giga SFP uplink, L2 PoE switch, Power Budget max96 W ,single port 30 W ,AI Extend, AIVLAN |
| 109 | SITC of 9U Rack for mounting switches, Patch Panels, Network rack shall be along with Spike, Fan tray, Cable Manager as required |
| 110 | Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification.43 inch |
| 111 | Supplying, installation, testing and commissioning of 6 TB Surveillance HDD |
| 112 | Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface concealed Steel/FRLS PVC conduit as per specification. |
| 113 | Supply, installation and testing for HDMI cable. |
| 114 | Public Address System.Supply, Installation, Testing and Commissioning of Public Address System. System Controller complete with Microprocessor based 6 Zone Call Station, Gooseneck Type Microphone (to be integrated with fire alarm system) |
| 115 | Rack Mounted 480 W Power Amplifier as per specifications |
| 116 | Supply and Surface laying of 2 core x 1.5 sq.mm black colour twisted pair shielded multi strand ATC armoured FRLS cable |
| 117 | 6W RMS False Ceiling Mount Speakers with inbuilt 100V Line Matching Transformer, wide opening angle, optimized for music & speech applications with mounting clamps as per specifications |
| 118 | Supply, Installation of Power supply unit. |
| 119 | Media Player / DVD Player with Remote |
| 120 | Information Technology Works Kiosk: Floor mount thin client based vertical tall Computer Kiosk Intel Quad core /4gb Memory/500gb Hdd/Sub 2.0-4,Usb 3.0-2/With 21.5 Inch Display. 1.6mm thk Mild Steel Enclosure; Antiglare & overlay tempered vandal resistant glass thickness - 3 mm; Capacitive Colour LED touch Screen; Screen Resolution 1920 x 1080 pixels; Window 11 Operating System (Pre-loaded); 120 Watt Max. Power Consumption; VGA, LAN, wifi, Audio In/Out Ports; with 6w speakers, headphone jack on top side of kiosk. |
| 121 | Supplying, Installation, testing & commissioning of 65 inch LCD -Back Lit LED,24x7 operation (Industrial Grade), Resolution 3840 x 2160 (4K),Built in Touch IR/Inglass/Capacitive /In cell, Brightness - 400 nits or Higher,Anti Glare Treatment on Surface, Input ports - HDMI(2),LAN Port (1),USB(2), HDMI/DP Output. Built in OPS Built in OPS (256 SSD, 8 GB Ram, core i5) with preloded Windows OS etc. complete as required. Certificates - BIS or equivalent. |
| 122 | Supplying, Installation, testing & commissioning of 65 inch or more LCD -Back Lit LED 24x7 operation (Industrial Grade),Resolution-3840*2160 (UHD), Landscape & Vertical Support ,Brightness - 500 nits or Higher, Contrast Ratio -1100:1, Anti Glare Treatment on Surface, Input ports -HDMI (3),DP(1),LAN Port (1),USB(2),Output Port-DP/HDMI. B uilt in OPS Built in OPS (256 SSD, 8 GB Ram, core i5) with preloaded Windows OS etc. complete as required Certificate : BIS or equivalent |
| 123 | Supplying, Installation, testing & commissioning of 43 inch or more LCD -Back Lit LED 24x7 operation (Industrial Grade),Resolution-3840*2160 (UHD), Landscape & Vertical Support ,Brightness - 500 nits or Higher,Contrast Ratio -1100:1, Anti Glare Treatment on Surface, Input ports -HDMI (3),DP(1),LAN Port (1),USB(2),Output Port-DP/HDMI. Built in OPS (256 SSD, 8 GB Ram, core i5) with preloaded Windows OS. complete as required. Certificate : BIS or equivalent |
| 124 | Virtual Mirror: Providing, installing, testing and commissioning of a virtual mirror (try on dresses) experience will computer kiosk Quad core /4gb Memory/500gb Hdd; Antiglare & overlay tempered vandal resistant glass thickness - 3 mm; Capacitive Colour LED touch Screen; Screen Resolution 1920 x 1080 pixels; 30- 42 inch display screen portrait mounted; with motion and gesture sensors; recording and providing live feedback, ability to send images over network; complete with necessary hardware, mounting installation and software. |
| 125 | Providing compact audio guide; Body pack receiver; Easy to hang on belt; Hi tech, light weight, rechargeable lithium battery with 3 hours battery backup; 200m transmission distance from portable transmitter and 250m from stationary transmitter; multi unit charging case; 100 independent channels and earphone output. |
| 126 | Consulting, Designing & Developing a Holistic Museum, work required as outlined in the scope of work section of the RFP |
| 127 | Curation of Audio content with, narration, songs & chains with voice of male and female artist with min 5 year experience (non-celebrity) as per tender specs |
| 128 | Curation of visual content with motion graphics in 4k resolution. 3D animation would include asset, background, FX, Environments, layout & rendering, motion graphics animation /composition would include parallax, matte paint, environment, vector graphics etc. |
| 129 | Rack Server E5-2620 v4, 8 core x 2, 2.10 GHz with 20 MB smart cache memory, 85 watt Processor; 64 GB Memory; 64 GB DDR4 RAM Upgradable Upto 1536 GB; 4x1 TB GB SSD; Server Scalability To Be Achieved Within The Box & Without Adding Nodes; single hot plug fans Server View Suite Software incl. Server View Installation Manager, Management Software und Tools; along with complete chassis and mounting installation. with latest windows server OS |
| 130 | Desktop PC, latest Gen Intel Core i7, 2 Nos 24-inch FHD Anti-Glare screen, 8GB RAM, 1TB HDD+ 500GB SSD, Windows 11 & antivirus with 5 Year licence , Wireless Keyboard and Mouse. |
| 131 | Supply Installation Testing & Commissioning of Laptop with i7 Processor or latest generation having 8 GB Ram 500 GB SSD, 14 inch display, OUT : HDMI, USB & RJ-45 etc. complete as required. |
| 132 | Mini PC (4 GB Ram + 250 GB SSD) windows OS Pre loded |
| 133 | Supply Installation Testing & Commissioning of P2 FLEXIBLE LED VIDEO WALL, , Bendable. Able to make various special shapes., Front service. Easy to maintain., Convenient for assembly and installation by fixing the modules to iron frame directly., High refresh rate 1920HZ / 2880HZ/3840 HZ., Pixel Pitch- 2mm, Reliable quality, long life-time., , Parameter Specifications, Parameter Value, Application Indoor, Pitch 2mm, Pixel density 250000dot/sq.m, Brightness ≥750nit, Color temperature 6500deg. K, Viewing angle – Horizontal 140, Viewing angle – Vertical 140, Module size(W*H) 320*160mm, Module resolution(W*H) 160*80pixels, Service access Front service, Min viewing distance 2m, Best viewing distance 2~100m, Cabinet size Customized, Contrast ratio 2000:1, Display refresh rate 1920HZ / 2880HZ/3840 HZ, Input power (max) 600 Watts/ sqm, Input power (typical) 240 Watts/ sqm, |
| 134 | Supply installation testing commissioning of Glass for HOLOGRAPHIC SCREEN : Custom built Holographic projection done on layered scrim screens complete as required as per the satisfaction of Engineer-in-charge. |
| 135 | Supply Installation Testing & Commissioning of 3LCD Laser Projector: Brightness: 7000-10000 Lumens, Display System: 3LCD System, Size of Display Area: 1\\" x 3 Bright Era LCD Panel, Aspect Ratio: 16:10, Resolution: WUXGA (1920 x 1200 pixels), Light Source: Type Diod Type, Contrast Ratio: Infinity : 1, Filter Replacement Cycle: 10,000 Hours, Throw Rario: 1.30:1 to 1.96:1, Les Shift: Powered (Vertical : +/- 99% ; Horizontal : +/- 51 %), Zoom / Focus: Powered, Input: 5BNC x 1,VGA x 1,DVI-D x 1, HDMIx1, HD Base T x 1,3G-SDI x 1 (Optional), Output: VGA x 1 (For 5BNC & VGA), Other Interface: USB Type-A x 1,USB Type-B x 1,RS232C x 1,RJ45 x 1, Keystone Correction: Horizontal: +/- 30 degrees ; Vertical : +/- 30 degrees, Auto Filter Cleaning: Yes, Auto Colour Calibration: Tes, Bayonet Lens Attachment Function: Yes, Colour Space (Picture Mode): sRGB 100%, Displayable Scanning Frequency: Horizontal: 15 kHz to 92 kHz; Vertical: 48 Hz to 92 Hz, Max. Computer Signal Input Resolution: 1920 x 1200, Max. Video Signal Input Resolution: 480/60i, 576/50i, 480/60p, 576/50p, 720/60p, 720/50p, 1080/60i, 1080/50i; With 3G-SDI Input: 1080/60P, 1080/50p, 1080/24p, 1080/30p, Power Requirement :AC 100 V to 240 V, 10.8 A to 4.4 A, 50 Hz / 60 Hz. |
| 136 | Providing Edge blending software with user friendly interface supporting playback of uncompressed video and image, 3D mapping, real time effects & Transitions, frame lock and should support external commands for projectors and lighting systems if integrated etc. complete as required. |
| 137 | Curation of projection mapping content with drone shoot with 4K resolution/ motion graphics in 4k resolution/2D animation with background audio & rendering etc. |
| 138 | Online ticketing system to be designed for government museum. It should have features of flexible payment options including cash and UPI, effortless QR code-based booking, multi-channel ticket delivery (SMS, WhatsApp, and thermal printer outputs), secure QR code validation via a mobile app, and offline support through a desktop application. The system provides customized reporting for operational insights and supports convenient UPI payments and e-ticket delivery via SMS. |
| 139 | Supply installation testing commissioning of Android-based Augmented Reality (AR) application for museum, the requirements include an AR Software Development compatible with Android, image recognition and 3D rendering capabilities to identify and augment museum items through the camera, and a content management system to handle the associated multimedia files like videos, audio clips, and photos. Additionally, the app should be designed to be user-friendly, with an intuitive interface that seamlessly presents detailed information about each sculpture or item when scanned. The system must also ensure scalability and easy updating of content, with robust performance across various Android devices. vendor to supply two pre-installed high quality mobile phones. |
| 140 | Electrical and HVACPoint winning (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc.) with 1.5sq. mm. PVC insulated cable FRLS with copper mulli slrand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) lsl marked of suitable size and 1.5sq. mm.'PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc.as required as per specification for :-Light point/fan points.Primary short point |
| 141 | Primary medium point |
| 142 | Primary long point |
| 143 | 3 Pin 6 Amp socket outlet on separate boardShort point |
| 144 | Medium point |
| 145 | Long Point |
| 146 | Twin control light pointsLong point |
| 147 | Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board |
| 148 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked sui1able size e1c. as required as per specification2x2.5 Sq.mm. |
| 149 | 4x2.5 Sq.mm. |
| 150 | 6x2.5 Sq mm. |
| 151 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cab|e FRLS with copper multi strand conductor ISl marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size etc. with 20/16 Ar°p. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq“ mm: PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :- On separate boardMedium point |
| 152 | Long Point |
| 153 | Extra-long-I |
| 154 | Extra-long-II |
| 155 | Extra-long-III |
| 156 | Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp |
| 157 | Supply and fixing vc conduit Is marked FRLS along wilh the accessories in concealed system etc. as requiredPVC. conduit 25 mm (HMS) |
| 158 | PVC. conduit 32 mm (HMS) |
| 159 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boyes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-1 or 2 Modu|e metal box |
| 160 | 3 Module metal box |
| 161 | 4 Module metal box |
| 162 | 6 Module metal box |
| 163 | 8/9 Module metal box |
| 164 | 12 Module metal box |
| 165 | 18 Module metal box |
| 166 | Supplying and drawing single core PVC insula\ed cab\e FRLS with copper multi strand conductor is marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.3 X 1.5 sq. mm. |
| 167 | 1 X 2.5 sq mm |
| 168 | Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in recessed/concealed rigid PVC conduit {HMS) FRLS ISI marked of” suitable size (conduit included) including 2mm thick accessories; connection etc, as required as per specification. (R-=fer General Notes for Classification of Conduit Wiring Poinl No.11) - 4 wire sub main6.0 sq. mm. cable |
| 169 | 10.0 sq. mm. cable |
| 170 | 16.0 sq. mm. cable |
| 171 | Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with thermal - magnetic release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2MCCB 36kA current rating - 200Amp & adjustable overload setting 80% 100% of In adjustable short circuit setting 6-10 Iri 3 Pole |
| 172 | Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase & N, 4 pole,50 Hz, 415 Volts, (Ics=100%Icu) AC supply with microprocessor release with inbuilt instantaneous protection & variable trip class 7.2 Ir & 6 Ir having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947- 2MCCB 36kA current rating - 400Amp &- adjustable overload setting 80% 100% of In, adjustable short circuit setting 6-10 In 4 Pole |
| 173 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts.50 Cycle, 10 kA/15 KA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 ;2002 & 60947-2 without enclosures :-SinqIe poleMCCI SP 6Amp to 32Amp 10kA raling |
| 174 | Double poleMCB DP 6Amp lo 32Amp 10kA rating |
| 175 | For Triple poleMCB TP 50Amp lo 63Amp 10kA rating |
| 176 | Four polesMCB FP 6Amp to 32Amp 10kA rating |
| 177 | MCB FP For 40Amp 10kA raling |
| 178 | MCB FP 50Amp to 63 Amp 10kA rating |
| 179 | Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar. earth bar, connection copper wire no less Ihan 16 sq.mm &two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)-12 Way double door IP 43 protection |
| 180 | 16 Way double door IP 43 protection |
| 181 | Supplying of approved make T 'N MCB UB metal double door with 43 protection with provision for FP MCB/ isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar. connection copper wire not less than 16 sq.mm & two earth terminal etc. complete as per IS:13032(exclusive of MCB & isolator):6 Way (8+18) |
| 182 | 8 Way f8+24) |
| 183 | 12 Way (6+36) |
| 184 | Supplying of approved make, powder coated metal double door vertical TPN MCB DB IP 43 protection with provision for MCCB upto160A TP/FP 36kA as incomer and space for SP/TP MCBs as outgoing (without MCCB/MCBs) inclusive of busbar & connections etc8 Way without MCCB |
| 185 | 12 Way without MCCB |
| 186 | Supplying A fixing of approved make industrial type metal plug & socket DBs (without MCB) SPN. sheet enclosed (dust protected) inclusive of 2 pole and earth metal plug and socket and space lo incorporate SPMCB complete as per specification as required.10 Amp |
| 187 | 20 Amp |
| 188 | Supplying & fixing of ISI marked Industrial type metal plug socket D.B.s (wi1hout MCBs) for TPN enclosed Three pole and earth metal plug and socket including space to incorporate TP MCB complete as per specification as required.30/32 AMP |
| 189 | Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) PSI marked complete as per I.S. standard conforming to IEC:61009-1 & IS:12640-2, 240/415V 50 Hz wilt 10 kA short circuit withstand capacity for earth leakage. overload & short circuit protection including connection in existing enclosure in approved manner as per specification.DP 4 Module)2 pole 32Amp, 30mA sensitivity |
| 190 | 2 pole 40Amp, 30mA sensitivity |
| 191 | Supply & fixing of approved make accepted standard sheet sleet enclosure (dust protected) duly powder coated paint neutral bar suitable for MCB/RCBOs/MCCB of capacity as required elc. complete as perspecifics\ion exclusive of. M.C.B / MCCB/RCBOs)DP/TP/FP enclosure |
| 192 | Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labor )MCB/lsolator SP/DP |
| 193 | MCB/MCCB isolator TP/TPN/FP |
| 194 | Labour charges for fixing sheet sleet enclosures. MCB/MCCBDB flush mounting type, as per accepted practice, duly embedded and end pIaI‹ completely flushed in wall, cable connection elc. complete:- |
| 195 | Supply and fixing as per specification call bell/buzzer of approved make with necessary materials complete.Buzzer |
| 196 | Supply and fixing of approved make sleep type modular electronic fan regulator including connection etc. as required on existing board100 Walt(2 module) |
| 197 | Supply, fixing, telling & commissioning wall/floor mounted LT panel. primer coated with powder coaled paint & provided with required gasket for dusúvermin proof with degree of protection IP42 suitable for 415Voll 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet up to 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section. outgoings, cable alleys & CT, PT Ampere'Metre, Voll Metre, seïeclor switches, frequency Metre, phase indicating lamğ. Energy Melre complete including cost of busbar supports detachable cable gland plates. 2 earthing termińals. in\emal wirin9 & fixing of separately supplied MCBs, MCCBs, ACB, panel mounted change over switch/SFUs. etc. as required but excluding cosl of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design |
| 198 | Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. Digital Ampere Metre with CTs with selector switch |
| 199 | Digital Volt Meter with selector switch & HRC fuse' |
| 200 | Ai minimum bus bar strips with PVC sleeves |
| 201 | LED lamp indicator |
| 202 | Supplying, erection and testing of approved make electric Ceiling fan ol double ball bearing complete with standard down rod,' canopy, hanging Shackle, Aluminium blades, withou1 regulator, A.C. 230-250 volls including connections wilh all necessary material complete of approved as required confirming to IS :374/2019 wi\h up\o date amendments.Ceiling fan - 900 mm sweep |
| 203 | Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum'air delivery |
| 204 | Supplying, erection and fessing of approved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230 - 250 volts with connections and including raw bol V anchor hole fastener etc. complete finished and as required.400 mm sweep |
| 205 | Supplying, erecting and testing of approved. make exhaust fan heavy duty Whmoun1ingVame, bades AC 230-250 compete connection and including, frame bolt/anchor hole fasteners etc. complete finished and as required.300mm sweep RPM 900 / 1400 |
| 206 | Supply and fixing Łed tube rod comprising of LED tube with non- integral/integral driver, upto 6500K color lamp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 Irn/Walt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/1516106 (201Z), IE C60598. IEC61347i/c connection wire, testing etc. to complete the job.Tube Light LED 1x 20/22 Watt Integral i/c ballen aluminum body, PC diffuser |
| 207 | Supply and fix recessed mounting LED down lighter. LED of 1 to 3 Watt each assembled on single MCPCB, having color temp up to 6500łt & having 50000 'burning hrs. life with minimum e L zo. system lumen output should be minimum with efficacy>100 ln/Wall. LED driver PF 0.95, THD < 20°/o & surge protection 4KV. The colour rendering index o LED light should be more than 70.Housing made of pressure die cas* aluminium /CRCA powder coated frame with glare free diffuses polycarbonate cover. Submission LM 79-08/lS16106 (2012) IEC60598, IEC 61347i/connection wire. testing etc. to complete the job.18/20Watt, cölor temp 3000-6500k as required |
| 208 | Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and .G:I. watering pipe 20mm dia 2.7 melre long etc. (but without charcoal or coke and sall) complete as required |
| 209 | Providing and fixing 25mm X 5 mm copper strip on surface or in recessed For connection etč. as required |
| 210 | Providing and fixing 4.00mm copper wire on surface or in recessed”' operating as required |
| 211 | With 3 metre G.I. pipes having outer pipe dia cf 50mm having 80-200 micron galvanizing, Inner pipe dia. of 25mrTl having 200-250 Micron galvanizing. connection. terminal dia, uf I 2r i: in nominal soil wilh 50 kg (two bag) back filling bentonite compound iJL. listed and confirm to relevant International/Indian standards around electrode upto ğround level. |
| 212 | Supply & fixing of BUS U-PVC trunking without its allied accessories as rëqd. 195 x 50 mm |
| 213 | Supply of XLPE insulated power cable (conforming 15-7098 Part-I) 1100 Volt grade, 1 corel2 core/3/• core/4 core ISl marked with alu. Standard /solid conductor 3Y core armored35 sq mm |
| 214 | 50 sq mm |
| 215 | Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cab\e with brass washer, rubber Fing complete erected with cable and lead connection etc. as per specificalion complete.Gland size 22mm suitable for cable 2,3,3½ & 4 x upto 6 sq. mm |
| 216 | Gland size 38 mm 3½ x 70 sq. mm, 3x95 sq. mm |
| 217 | Laying of one number armoured / unarmoured power cable 1.1 KV grade of size exceeding 25 sq. mm but not exceeding 120 sq. mm. in the existing RCC Hume /Stone ware/G.I. Pipe/surface in existing trench as required. |
| 218 | Supply and Erecting of Perforated type Fiber Glass Reinforced Polymer (FRP) / Glass Fiber Reinforced Polymer (GRP) cable tray of specific dimensions. The cable tray shall be hung from ceiling/ fixed to wall with necessary angle/ flat iron ceiling suspensors, clamps, nuts, bolts, washers complete with required tees, bends etc. as per specification to complete the job. The tray shall be as follows :-150 mm width with straight coupler plate size: 200x25x4mm & 8 sets of SS 304 Hardware size: M5x20mm |
| 219 | 200 mm width with straight coupler plate size: 200x25x4mm & 8 sets of SS 304 Hardware size: M5x20mm |
| 220 | Supply, fabrication and erection of angle/channel/f!at iron filling (overhead line & sub-station etc such as 'D' bracket. cross arms, top clamp, 'V' cross arms; back/support clamp or other similar work etc including nut bolls of required size. making holes, fabrication, welding cutting, etc. and painting with one coat of red oxide paint 6 \wo coat of aluminium paint as |
| 221 | Labour charges for erection of angle/channel! /flat iron fitting for overhead lińe A sub-station etc such as ’D' bracket, cross arms, top clamp. 'V' cross arms, back/support clamp or other similar work etc. including nu bolts of required size, as required as per specification. |
| 222 | Control cable: - Supply and laying, testing & Commissioning of following sizes of copper conductor control cables on existing Tray including fixing clamps & proper connections to equipment etc. complete as required.4Cx 4 sq.mm |
| 223 | 4Cx 6 sq mm |
| 224 | Supply, installation, testing and commissioning of 'Silent Type' diesel genera ling set comprising with diesel engine waler cooled, Synchronous' alternator, AMF control panel single/three phase, acoustic enclosure battery with charger and related accessories including PCC 1:2:* platform, incoming cable 10 mtr, earthing Cu/GI pIate 2No/2No, exhaust pipe 'B' class with insulation as per CPWD specification and CPCB – Norms Supply, installation. testing and commissioning of diesel generating set Three phase, water cooled with AMF control panel.62.5 KVA, 415V. |
| 225 | Operation and Maintenance cost of 1st Year after expiry of DLP Period. As per scope of work mentioned in DNIeT. |
| 226 | Operation and Maintenance cost of 2nd Year after completion of 1st year of AMC. As per scope of work mentioned in DNIeT. |
| 227 | Operation and Maintenance cost of 3rd Year after completion of 2nd year of AMC. As per scope of work mentioned in DNIeT. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail