| 1 | Dismantling reinforced cement concrete orreinforced brick work including stacking ofdismantled materials as directed by Engineer-In-Charge within a distance of 60 meters (200 feet). Sor 694 |
| 2 | Dismantling brick work or stone work in lime or cement mortar and including stacking of materials as directed by Engineer-In-Chargewithin a distance of 60 meters (200 feet). Sor 692 |
| 3 | Dismantling existing plaster including disposal of refuse as directed by Engineer-In-Charge within a distance of 60 meters. (SOR 706) |
| 4 | Dismantling doors and windows leaves including stacking of materials as directed by Engineer-In- Charge with a distance of 60 meters (200 feet).(SOR 703) |
| 5 | Excavation in foundation in ordinary soil (Loam, Clay or sand) including lift up to 1.50m and lead up to 30 as per as per s.i.no.251 |
| 6 | Providing and laying cement concrete in 1:4:8 (1cement , 4C/sand 8 s/ballast in 40mm) and curing complete i/c cost of form work in foundation and floor as per PWD s.i.no.275a ch-5 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets,columns, pillars, piers,abutments, posts and struts etc. including cost of centering, shuttering, finishing and excludingreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) DSR 5.2.2 i upto plinth |
| 8 | Brick work with common burnt clay FPS non modular brick of class designation-100 in superstructure above plinth level in 1:4 cement, c/sand Sor 6.4.1 |
| 9 | RCC work in beam , lintels, suspended floors, roofs, having balconies, shelves, chajjas, bands, staircases, above plinth level upto floor five level, i/c the cost of centering, shuttering, finishing and excluding reinforcement -1:1.5:3 cement, coarse sand and stone aggregate 20 mm nominal size i/c all as per dsr no.5.3 sr 8 ch- 05 |
| 10 | Steel reinforcement for RCC work i/c straightening, cutting, bending all complete as DSR no.-5.22.6 CH-10 |
| 11 | Cover block for rcc work.on MR |
| 12 | 12 mm cement plaster on brick work with cement mortar 1:4 (1cement:4 coarse ) (SOR 13.4.1) |
| 13 | 20 mm cement plaster with cement mortar 1:4 (1cement:4 coarse ) (SOR 590 ii |
| 14 | 6mm plaster on ceiling including chipping of CC/RCCsurface before plastering in cement mortar of mix 1:3 (1cement : 3 Fine sand) (Not Less than in 1.25 FM)(SOR 13.16.1 |
| 15 | Finishing walls with Acrylic Smooth exterior paint (Apex) of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)DSR no.13.46.1 |
| 16 | Steel wok in built up tubular (round,square or rectangular hollow tubes etc.) truses etc. including cutting. Hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (Hot finised welded type tubes. as DSR no. 10.16.1 |
| 17 | Supply and fixing of flush doors, commercial quality conforming of I.S. 2202 part-1 (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts, locks, handles, springs, fitting withnecessary screws to be supplied departmentally as si no. 470B 32mm |
| 18 | Painting on Steel/G.S. sheet with synthetic enamel paint .as DSR no. 13.53.1 |
| 19 | Making grooves 10 to 12mm wide × 8mm deep in plaster of the wall or in ceiling vertically or orizontally as required. As pwd si no. 598(1) |
| 20 | Making drip course in sunshade or FACIA as per direction as Engineer-In-Charge As pwd si no. 598(2) |
| 21 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 TypeA, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,s.i no. 12.41.2 |
| 22 | Providing and laying vitrified floor tiles etc., complete. DSR no.11.41.2 |
| 23 | S/F 6mm thick china white glazed tile on wall laid with 1:3 cement c/sand i/c all complete as per PWD s.i. no.628ch-14 |
| 24 | supply and fixing hexagonal /round GP fan box with ms bar as schedule item no. 1149 |
| 25 | P/f of Wiring point with 1.5 sq mm FRLSH PVC insulated multistrand single core copper conductor cable in pvc conduit with 14 swg copper earth continuity wire GP box, piano type switch and ceiling rose holder on and earthing point |
| 26 | Wiring for light/power plug with FRLSH PVC insulated multistrand single core copper conductor cable in pvc conduit with 4sq. earth continuity wire required(a) 2x4 sq.mm as code no. 1.12 |
| 27 | (b) 2x6 sq.mm as code no. 1.14.4 |
| 28 | Supply and fixing of LED tube light batten fitting 1×22 watt as schedule item no. 1413A |
| 29 | S/f of ceiling fan 1200mm of approved quality as code no. 19.1 |
| 30 | Supply and fixing of mcb distibution board as code no.2.4.2 |
| 31 | Supply and fixing of 5 to 32 Amp MCB (10kA) CAT A as code no. 2.10.1 |
| 32 | P/F signboard of black granite plate in Brick masonary in Cement mortar i/c all complete Please Enable Macros to View BoQ information |