Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Fire Extinguisher- Co2 |
| 2 | Fire Extinguisher- Dry Powder |
| 3 | Pre-Cast Concrete reinforcement Bench (Chair type Bench with back rest) consisting of 2 nos. L-shaped base support of thk. 100 mm, back height 1000 mm & front height 450 mm. Base width – 620mm and 5 nos. Reinforced concrete planks in specified colour, of size 1500x100x50, 1nd 1 no plank of size 1500x200x50 mm manufactured by using M30 grade of concrete & reinforced suitably to prevent damage during handling, transportation, erection and long use. All parts joined together with nuts & bolts of suitable size.Bench top and bench planks are treated with paint Erection of the bench to be done by us(Cost includes 10% CP & 5 % OHC) |
| 4 | Supply & fitting of ShyamJyoti™ LED Based Solar Street Lighting System Luminary : 12W LED Luminary Luminary Housing- Weather Proof Housing Structure- Hot Deep Galvanized Module Pole : Hot Deep Galvanized MS Pole (4.5 Mtr.) Battery Box : Corrosion Resistant Painted Power Coated Metal Battery Box Other : Suitable Cable, Etc. Battery : 19.8Ah 14.8V Lithium-Ferro Battery of MNRE Approved Module : 75Wp of HBL / Gautam Solar/IEC Equivalent (Cost includes 10% CP & 5 % OHC) |
| 5 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I. |
| 6 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 7 | Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 8 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume). |
| 9 | Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
| 10 | Providing designation 75B brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an |
| 11 | Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\" x 4.5\\" x 3\\") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification anddirection of E/I. |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand (zone-iii) :4 graded stone aggregate 20 mm nominal size) all complete as per building specifications and direction of E/I |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 15 | 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6graded stone aggregate 20 mm nominal size) |
| 16 | Providing RCC M200 with nominal mix of (1:1.5:3) infoundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of FM 2 to 3 including screening, shuttering mixing cement concrete in mixer and placing in position, vibrating striking , curing (but excluding the cost of reinforcement) ,taxes and roylity all complete as per building specification and direction of E/I |
| 17 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 19 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 1.10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement (All work up to plinth) |
| 20 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 1.10% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement (All works above plinth level upto floor V level) |
| 21 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 23 | Walls (any thickness) including attached pilaster, butteresses, plinth and string courses etc. |
| 24 | Centering and shuttering including strutting , for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 25 | Suspended floors, roofs, landings, balconies and access platform |
| 26 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 27 | Stairs, (excluding landings) except spiral-staircases |
| 28 | Weather shade, Chajjas, corbels etc., including edges |
| 29 | Providing and mixing water proofing material in cement concrete |
| 30 | Providing designation 75B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, costs of screening, materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I. |
| 31 | Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 32 | Providing Toe steel reinforcement of 8mm dia rods as approved |
| 33 | Providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.(a)Providing Toe steel reinforcement of 10 mm dia rods as approved |
| 34 | Providing Toe steel reinforcement of 12 mm dia rods as approved |
| 35 | Providing Toe steel reinforcement of 16mm dia rods as approved |
| 36 | Providing Toe steel reinforcement of 20-25 mm dia rods as approved |
| 37 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 38 | Providing 12mm cement mortar (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 39 | Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 40 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 41 | Providing 1.5mm neat cement punning including curing carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 42 | Extra of plaster work over exterior surface for each consecutive floor above above first floor including cost of scaffolding etc. All complete as perdirection of E/I. |
| 43 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 44 | Supplying, fitting and fixing 30mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core bended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 45 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 46 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 47 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 48 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby redArea of slab upto 0.50 sqm |
| 49 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work |
| 50 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 51 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm-do-do |
| 52 | Providing and laying Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less then 0.08% and conforming to IS: 15622/ISO 13006 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement:4 Coarse sand0, jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with wite cement and matching pigments etc, complete Size of tiles 600 x 600 mm. |
| 53 | Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete asper building specification and direction of E/I.(iv) 600X600 mm size |
| 54 | Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification anddirection of E/I. |
| 55 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I.With commercial grade colour Tiles. |
| 56 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cementcompound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymermixed slurry. |
| 57 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 58 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 59 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 60 | Providing and fixing pressed steel door frames conforming to IS: 4351,-- 'Profile C Fixing with adjustable lugs with split end tail to each jamb |
| 61 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position withM.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.(M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/ window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variationin profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 62 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.Sscrews shall be paid separately)30 mm thick |
| 63 | Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification anddirection of E/I. |
| 64 | Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resine of standard make with Aluminium fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification anddirection of E/I. |
| 65 | Supplying, fitting and fixing 250X20X6mm L-type M.S clamp properly fishtailed, including maiking holes and setting as same in 250X125X75mm. Cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I. |
| 66 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 67 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 68 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded /mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge..Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately.Two track two panels sliding window with Aluminium channel for roller track, wool pile,nylon rollers with SS 304 body. |
| 69 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc |
| 70 | Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 71 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 72 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 73 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 74 | Providing 60 mm thick C.C. paver block of M-35 grade with approved color design and pattern. |
| 75 | Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Springcore (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 76 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia |
| 77 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.In Recharge Well (Лr²h) |
| 78 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-chargeIn Recharge Well |
| 79 | Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I. |
| 80 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 81 | Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering, etc. And disposing of surplus excavated soil as directed within a lead of 50 m Hard/dense soil. All kind of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 82 | Providing and laying Non pressure NP2 class (light duty)RCC Pipes with collars jointed with stiff mixture of cement mortar in the propoertion of 1:2 (1 cement : 2 fine sand) including testing and jointing etc complete.150 mm dia RCC pipe |
| 83 | Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. |
| 84 | Geotextile Filter: (Laying of a geotextile filter between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching.) |
| 85 | Angle Size (ii) 65x65x6/8/10 (Gr.A) |
| 86 | Drilling 6mm dia hole M.S. angle iron for fixing of staples etc. as per building specification anddirection of E/I. |
| 87 | Labour for cutting of M.S. angle iron post to required length, one end splitted as fishtailed in a length of 150mm complete as per building specification and direction of E/I. |
| 88 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel barsfor sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In Charge |
| 89 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2Coarse sand) to match the existing floor :With Chlorpyriphos/Lindane E.C. 20% with 1%concentration. |
| 90 | Provide two coat of snowcem of approved shade & make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding, curing & taxes all complete as per building specification & direction of E/I. |
| 91 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 92 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) |
| 93 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 94 | Earthwork in backfilling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-charge ( Refilling ) |
| 95 | Cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH Rig machine, all complete including supplying all materials, tools, drilling rig, Air Compressor and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicles up to the site (Basic rates)(i) from 0 to 50M |
| 96 | Cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH Rig machine, all complete including supplying all materials, tools, drilling rig, Air Compressor and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicles up to the site (Basic rates)(ii) from50 to 125M |
| 97 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia |
| 98 | Supplying of ISI mark HDPE . pipe of following class and dia. excluding GST and including Royality etc. and hire charges of P&M (with pol) procured from DWSD Jharkhand .160 mm HDPE .for Tube well |
| 99 | Supplying of ISI mark HDPE . pipe of following class and dia. excluding GST and including Royality etc. and hire charges of P&M (with pol) procured from DWSD Jharkhand .90 mm.HDPE for Main Pipe line |
| 100 | supplying labour and tools for laying and jointing HDPE pipes in trenches and making butt welded joint, supplying heating mirror, jack etc. nad proveding night guard, barrier -do-do. 160 mm HDPE .for Tube well |
| 101 | supplying labour and tools for laying and jointing HDPE pipes in trenches and making butt welded joint, supplying heating mirror, jack etc. nad proveding night guard, barrier -do-do. 90 mm.HDPE for Main Pipe line |
| 102 | Supply of Submersible pump pumpset confirming to IS 8034 and motor confirming to IS: 9283. Pump shall be suitable for vairous delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415V+10%,3Ph, 50Hz. A.C. supply with cable gaurd, thrust carbon/fiber bearing to withstand entire hydraulic thrust water proof winding shall be provided. The pump set shall have suitable outlet as per manufacturer design. Anti thrust stream lined nonreturn valve shall be provided with pump. 3 meter submersible copper conductor cable in single /double run shall be providede with each pump. Submersible Pump 150mm dia ( with bronze impeller) up to 8 stages dia 3.0 H.P. |
| 103 | Supplying triple spur gear type chain pulley block suitable for capacity as below 3m lift complete with load chain and hand chain suitable for above lift, tested to 50% overload as per IS 3832 carrying ISI mark 2 Ton capacity |
| 104 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 105 | Circuit/submain wiring in PVC conduit:-Wiring for circuit /submain wiring along with earth wire the fillowing sizes of FR PVC insulated copper conductor single core cable in surface recessed PVC conduit as required.4 x 4.0 sq.mm + 2 x 2.5 sq.mm earth wire |
| 106 | D.O.L. starter with SS Enclosure with 380/415 volt coil 10HP |
| 107 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 108 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 109 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 110 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 111 | Providing tor steel reinforcement of 10 mm dia. As per approved design and drawing excluding carriage of MS rods to work site cutting, bending, and binding with annealed wire with cost of wire removal of rust, placing the rods in position all complete as per building specification & direction of E/I. |
| 112 | MEPFIRE FIGHTING:Providing laying, testing & commisioning of C class heavy duty MS pipe confirming to IS 1239/3589 i/c welding, fittings like elbows,tees, flanges, tapers, nuts,gaskets etc. and fissinf the pipe on the wall/ceiling with suitable clamp/support frame and painting with two coats of synhetic enamel paint of required shade complete as required.100 mm Dia |
| 113 | Supplying, fixing single headed internal hydrant valve with instantaneous Gunmetal/ Stainless Steel coupling of 63 mm dia with cast iron wheel, ISI marked, conforming to IS 5290 (Type- A ) with blank Gunmetal/ Stainless steel cap and chain as required.Single headed Stainless steel. |
| 114 | Supplying fixing,testing and cpmmisioning of butterfly valve of PN 1.6 rating with bronze/ gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required.80 mm Dia. |
| 115 | Providing , installation, testing and commisioning of non return valve of following sizes confirming to IS :5312 complete with rubber gasket, GI bolts, nuts, washers etc as required.100 mm Dia |
| 116 | Supplying and fixing first aid Hose reel with MS construction spray painted in post office red, confirming to IS 884 complete with the following as required.20mm nominal internal dia water hose thermoplastic (Textile reinforce) type 2 as per IS 12585.20mm nominal internal dia gun metal glove valve & nozzle.Drum and bracket for fixing the equipment on wall.Connection from riser with 25mm dia stop gun metal valve & MS Pipe and socket.40m. |
| 117 | ELECTRICALPoint wiring in PVC conduit, with pino type switch:-wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor singal core cable in surface/ recessed PVC conduit with piano type switch, phenolic laminated sheet, suitable size PVC/G.I box ect. asGroup B |
| 118 | Point wiring in PVC conduit, with modular type switch -Point wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. asrequired. Group C |
| 119 | S/F of following sizes of pvc conduit along with accessories in surface/ recess including cutting the wall making good the same in case of recessed conduit as required.20mm |
| 120 | S/F of following sizes of pvc / G.I box on surface/ recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.75 x 75x 50mm deep / (4\\"x4\\") |
| 121 | S/F of following sizes of pvc / G.I box on surface/ recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.126mmx277mmx61mm deep /(6\\"x12\\") |
| 122 | S/F Piano type switch/ socket:-Supplying & fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps, one way switch |
| 123 | S/F Piano type switch/ socket:-Supplying & fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amps, socket outlet |
| 124 | S/F Piano type switch/ socket:-Supplying & fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 amps, 6 pin socket outlet |
| 125 | Twin control point wiring in PVC conduit, with modular type switch - Wiring for twin control light point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way with modular switch, modular plate, suitable size G.I. box etc. as required. |
| 126 | Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable in surface recessed PVC conduit, along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 127 | Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.2x1.5 Sqmm + 1x1.5 sqmm earth wire (for Single Separate 5A from nearest switch board and wallfans) |
| 128 | 2x2.5 Sqmm + 1x2.5 sqmm earth wire (for switch board circuit to LDB). |
| 129 | 4x6 Sqmm +2x6 sqmm earth wire.(to be used for all LDB & UPS DB.) |
| 130 | 2 x 10.0 sq.mm. + 1 x 10.0 sq.mm. earth wire |
| 131 | S/F Modular type switch socket -Supplying and fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required5/6 amps, one way switch |
| 132 | 5/6 amps, 3 pin socket outlet |
| 133 | S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc. as required . (For light plugs to be used in non residential buildings) |
| 134 | S/F power plug point with Modular type accessories - Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface of in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required. (For light plugs to be used in non residential buildings) |
| 135 | S/F batten holder:-Supplying & fixing batten/ angle holderincluding connection etc. as required. |
| 136 | ITC fluorescent fitting directly on surface:- Installation, testing and commissioning of Pre- wired fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube etc.directly on surace or ceiling/ wall, including connection with 1.5 Sq. mm. FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 137 | S/F Modular type electronic fan regulator :- Supplying and fixing stepped type electronic fan regulator on the existing modular plate & switch box including connections but excludingmodular plate etc. as required. |
| 138 | ITC cEILING fan - Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with1.5 sq.mm FR PVC insulated, copper conductor,single core cable etc. as required. |
| 139 | Supplying and fixing following way single pole neutral, sheet, MCB disrtibution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without CB/RCCB/Isolator)8 way, single door |
| 140 | Supplying and fixing 6 amps to 32 amps rating,240 volts, \\"B\\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. asrequired.6/32, single pole, \\"B\\" series |
| 141 | S/F DP MCB Isolator -Supplying and fixing following rating, double pole,240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required40 amp |
| 142 | Supplying and fixing of 9/10 Watt LED Bulb |
| 143 | Supplying and fixing LED Batten (20/22W) |
| 144 | Supply of Recess Mounting LED Square Down light(15/16W) |
| 145 | Supply of ceiling fan 48\\" (1200mm) BLDC Sstar 15:374:2079 |
| 146 | 15/16 amps, one way switch |
| 147 | 6 pin 15/16 amps, socket outlet |
| 148 | Supply fitting fixing of Bulk head fitting with 9/10 watt CFL/LED |
| 149 | 15/16 Watt bulb |
| 150 | (18/20W) LED squre down light |
| 151 | 20/22W LED tube light |
| 152 | CEILING FAN 56\\" (1400MM ) |
| 153 | S/F ceiling rose |
| 154 | COPPER EARTH PLATE ELECTRODE:-Earthing with copper plate 600mmx 600mmx 3mm thick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or cock and salt) complete etc. as required.(2 Nos. for Main Panel,2 Nos. for APFCpanel, 4 Nos. for xmer, 4 Nos. for DG set.) |
| 155 | S/L 8 SWG copper wire in ground (for main panel and APFC panel) :- |
| 156 | P/F 25 x 5mm copper earth strip in pipe :-Providing and fixing 25mmx5mm cpper earth strip in 40mm & 4.5Mtr long G.I.pipe for earthelectrode etc. as required. |
| 157 | P/F G.I. lightning conductor finial -Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, G.I. tube, having single prong at top, with 85mm dia 3mm thick G.I. base plate including holes etc. complete as required. |
| 158 | Reverting sweating and soldering lighting conductor tape :Reverting sweating and soldering of copper/G.I. tape (with another copper/G.i. tape,base of the finial or any other metallic object) as required. |
| 159 | P/F G.I. lightning conductor tape in horizontal run Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontalrun) |
| 160 | P/F G.I. lightning conductor tape in vertical run - Provding and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightningconductor complete as required. (For vertical run) |
| 161 | Cable Laying of 1.1 KV & 11 KV :-MV Cable Laying upto 120 Sq mm in ground:- Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm. but not exceeding 120 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refillingthe trench etc, as required. |
| 162 | Providing and fixing of XLPE, Aluminium Armoured PVC Cable confirming to IS IS7908 (Part 1) 1988 0f grade 1.1KV. Make:- Havells / Finolex /PolycabSupplying PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable withaluminium conductor- 3.5 core, 50 sq.mm |
| 163 | Supplying, installation, testing and commissioning of cubical type MV Panel made out of 14 SWG sheet steel, totally enclosed IP-54 protection, free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than 75mmx75mmx5mm (thick), Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with thefollowing switchgears. (Main LT panel)INCOMER:-630 Amp (50KA),manual,fixed,MCCB (1 Nos. ), 315 Amp,manual,fixed,MCCB (2 Nos. ),CHANGE OVER:-320 Amp,4 POLE (1 Nos. ), 1 Setphase indication lights (R, Y, B), 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No.Ammeter (digital type) with inbuilt ASS . AL. BUSBAR CHAMBER:-800 Amps. TP&N Aluminium bus bars (50 KA), OUT GOINGS:- 4 pole MCCB 63 A,16 kA with fixed thermal magnetic setting.(16 Nos. ), 4 pole MCCB 40 A,16 kA with fixed thermal magnetic setting.(15Nos. ), 4 pole MCCB 160 A,16 kA with fixed thermal magnetic setting.(1Nos. ),6/32 A,DP (5 Nos. ) |
| 164 | PLUMBINGSupplying and fixing male ended 15 mm dia brass bib cock ofapproved quality (wt. not less than 350 grms) with extra socket all complete as per specification and direction of E/I. |
| 165 | Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I.(A) 15MM DIA BRASS STOP COCK |
| 166 | Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I.32 mm and weight not less than 700 gms. |
| 167 | 40 mm and weight not less than 1.0 kg. |
| 168 | Supplying, fitting and fixing viterious white glazed earthen wareI.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as perspecification and direction of E/I.(A) 580mm long width(C) With 10 lit low level P.V.C. cisterns |
| 169 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm PVC waste pipe 750mm long with brass coupling at one end and making plumber joints etc. allcomplete as per specification and direction of E/I. |
| 170 | Making holes in walls for laying H.C.I. pipes and restoring thesame after pipe laying as per specification and direction of E/I.(i)125mm thick wall |
| 171 | (ii)250mm thick wall |
| 172 | Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR +15% for labour and Contractors profit) ALL JAGUAR FITTING.Piller Cock (Long Neck) (for basin) |
| 173 | Wall mixer with provision for oygghead shower with elbowcouplinq and wallflanqe (lSl Marked) |
| 174 | Towel Rail 24\\" |
| 175 | Soap dish |
| 176 | Tumbler Holder |
| 177 | Glass shelf 22' |
| 178 | Telephonic Shower with flexible pipe (ISI Marked) |
| 179 | Providing and fixing N.P/C.P. brass /P.V.C. porcelain shower rose of 1Smm inlet etc. all complete as per speclflcatlon and directionof E/I.150mm dia P.V.C. shower |
| 180 | Providing and supplying in standard lengths High Density Polyethylene Pipe (HDPE Pipe) 25mm to 500mm dia confirming to lS 4984 I 14151 I 12786 I 13488 (Latest Revision with necessary jointing materials like mechanical connector i.e. thread/ insert joint / quick release coupler joint / compression fitting joint or flanged joints excluding coupler / specials and taxes. Note :- The Rates are F.O.R at worksite in Jharkhand including Royatty, inspection Charges and other taxes but lexcluding cST &C.P.(a) 160 mm dia pipe |
| 181 | (b) 225mm dia |
| 182 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and makinggood the walls wherever required :Kitchen sink with drain board510x1040 mm bowl depth 225 mm. |
| 183 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of jointscomplete as per direction of15 mm nominal outer dia |
| 184 | 20 mm nominal outer dia |
| 185 | 25 mm nominal outer dia |
| 186 | 32 mm nominal outer dia |
| 187 | Providing and fixing PTMT grating of approved quality and colour.Circular type - 100 mm nominal dia 100 mm nominal dia |
| 188 | 125 mm nominal dia with 25 mm waste hole |
| 189 | Supplying, fitting and fixing the following items complete with allmaterials as per specification and direction of E/I.Mirrors of 6mm thick glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror600mm x 450mm size |
| 190 | polythene water storage tank of mark with covei and suitablelocking system in double layer confirming to lS: 12701-1996 with Latest revision. |
| 191 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes110 mm Rain water pipe--waste pipe |
| 192 | Coupler 110 mm |
| 193 | Bend - 110mm |
| 194 | Shoe - 110 |
| 195 | cowel100 mm dia (weight without ear and socket 3.25 kg) |
| 196 | 100 mm dia \\"P\\" trap (wt without ear and socket) 8.5 kg |
| 197 | 20 mm nominal dia Pipes |
| 198 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) andmaking good the wall etc. complete. 110 mm |
| 199 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work25 mm nominal dia Pipes |
| 200 | 32 mm nominal dia Pipes |
| 201 | 40 mm nominal dia Pipes |
| 202 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe |
| 203 | 250 mm dia. R.C.C. pipe |
| 204 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materialswith snap fittings of approved quality and colour, weighing not less than 105 gms |
| 205 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey-comb shaft with bricks and S.W. drain pipe 100mm diameter, 1.8 m long complete as per stanDSRd design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 206 | Supply of HCI Pipe 80mm dia single socket6'-0\\" long with ear weight 13kg) |
| 207 | Carriage of materialChips |
| 208 | Cement |
| 209 | Steel |
| 210 | Metal |
| 211 | Bricks |
| 212 | Add GST 18% |
| 213 | Labour Cess 1% Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy